SU-F-T-321: The Effect of an Electromagnetic Array Used for Patient Localization and Tumor Tracking On OSLD in Vivo Dosimetry

Purpose: The purpose of this study was to observe the effect of an electromagnetic array used for patient localization and tumor tracking on optically-stimulated luminescent in-vivo dosimetry. Methods: A linear accelerator equipped with four photon energies was used to irradiate optically stimulated luminescent dosimeters (OSLDs) at the respective dmax depths and in the buildup region, with and without the presence of an electromagnetic array used for tumor tracking and patient localization. The OSLDs were placed on solid water slabs under 5 mm bolus and on each face of an octagonal phantom, and irradiated using both static beam and arc geometry, with and without the electromagnetic array under our setup. The electromagnetic array was placed 6 cm above the phantom to coincide with similar distances used during patient treatment. Ionization chamber measurements in a water phantom were also taken initially for comparison with the simple geometry OSLD measurements and published data. Results: Under simple geometry, a negligible change was observed at dmax for all energies when the electromagnetic array was placed over the setup. When measuring at five millimeter depth, increases of 1.3/3.1/16/18% were observed for energies 4X/6X/10X/15X respectively when the electromagnetic array was in place. Measurements using the octagonal phantom yielded scattered results for the lateral and posterior oblique fields, and showed increases in dose to the OSLDs placed on the anterior and lateral anterior faces of the phantom. Conclusion: Placing the electromagnetic array very close to the patient’s surface acts as a beam spoiler in the buildup region (at 5 mm depth), which in turn causes an increase in the measured dose reading of the OSLD. This increase in dose is more pronounced when the OSLD is placed directly underneath the electromagnetic array than off to one side or the other.

43 PARTICLE ACCELERATORS↗

Daytime Solar Heating of Photovoltaic Arrays in Low Density Plasmas

The purpose of the current work is to determine the out-gassing rate of H2O molecules for a solar array placed under daytime solar heating (full sunlight) conditions typically encountered in a Low Earth Orbital (LEO) environment. Arc rates are established for individual arrays held at 14 C and are used as a baseline for future comparisons. Radiated thermal solar flux incident to the array is simulated by mounting a stainless steel panel equipped with resistive heating elements several centimeters behind the array. A thermal plot of the heater plate temperature and the array temperature as a function of heating time is then obtained. A mass spectrometer is used to record the levels of partial pressure of water vapor in the test chamber after each of the 5 heating/cooling cycles. Each of the heating cycles was set to time duration of 40 minutes to simulate the daytime solar heat flux to the array over a single orbit. Finally the array is cooled back to ambient temperature after 5 complete cycles and the arc rates of the solar arrays is retested. A comparison of the various data is presented with rather some unexpected results.

Galofaro, J.↗

On the Computation of the Beam Position in the Arcs of the Hadron Storage Ring

To compensate for the velocity differences of the hadrons and electrons in the Electron-Ion Collider, the hadron beam will be operated in a large range of the radial displacement (±20 mm in the 64 mm wide vacuum chamber). Machine protection and beam optics measurement require high-accuracy calculations of the beam position from the signal induced on the pickup electrodes. For the HSR, we need at least the fifth-order polynomial fit, which provides 70 microns r.m.s. error in the 40 by 20 mm region of interest as shown in Fig. 1. The calculations are made using a MATLAB script solving the 2D electrostatic problem.

43 PARTICLE ACCELERATORS↗

Conditions for reliable time-resolved dosimetry of electronic portal imaging devices for fixed-gantry IMRT and VMAT

Purpose: The continuous scanning mode of electronic portal imaging devices (EPID) that offers time-resolved information has been newly explored for verifying dynamic radiation deliveries. This study seeks to determine operating conditions (dose rate stability and time resolution) under which that mode can be used accurately for the time-resolved dosimetry of intensity-modulated radiation therapy (IMRT) beams.Methods: The authors have designed the following test beams with variable beam holdoffs and dose rate regulations: a 10 Multiplication-Sign 10 cm open beam to serve as a reference beam; a sliding window (SW) beam utilizing the motion of a pair of multileaf collimator (MLC) leaves outside the 10 Multiplication-Sign 10 cm jaw; a step and shoot (SS) beam to move the pair in step; a volumetric modulated arc therapy (VMAT) beam. The beams were designed in such a way that they all produce the same open beam output of 10 Multiplication-Sign 10 cm. Time-resolved ion chamber measurements at isocenter and time-resolved and integrating EPID measurements were performed for all beams. The time-resolved EPID measurements were evaluated through comparison with the ion chamber and integrating EPID measurements, as the latter are accepted procedures. For two-dimensional, time-resolved evaluation, a VMAT beam with an infield MLC travel was designed. Time-resolved EPID measurements and Monte Carlo calculations of such EPID dose images for this beam were performed and intercompared.Results: For IMRT beams (SW and SS), the authors found disagreement greater than 2%, caused by frame missing of the time-resolved mode. However, frame missing disappeared, yielding agreement better than 2%, when the dose rate of irradiation (and thus the frame acquisition rates) reached a stable and planned rate as the dose of irradiation was raised past certain thresholds (a minimum 12 s of irradiation per shoot used for SS IMRT). For VMAT, the authors found that dose rate does not affect the frame acquisition rate, thereby causing no frame missing. However, serious inplanar nonuniformities were found. This could be overcome by sacrificing temporal resolution (10 frames or 0.95 s/image): the continuous images agreed with ion chamber responses at the center of EPID and the calculation two-dimensionally in a time-resolved manner.Conclusions: The authors have determined conditions under which the continuous mode can be used for time-resolved dosimetry of fixed-gantry IMRT and VMAT and demonstrated it for VMAT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Plasma Interactions with a Negative Biased Electrodynamic Tether

The ProSEDS conductive tether design incorporates two distinct types of tethers from a plasma interaction viewpoint. The 200 m closest to the Delta 11 spacecraft is insulated from the plasma, and the remaining 5000 m is semi-bare. This latter portion is semi-bare because it has a conductive coating applied to the wires to permit electron collection while also regulating the overall tether temperature. Because the tether possesses these two distinct types of tethers, a transition point exists between the two types that form a triple point with the space plasma. Insulated tethers can suffer from a second plasma interaction if the insulation is weakened or breached, such as by pinholes caused by small particle debris strikes. Because electrodynamic tethers are typically long, they have a high probability of such impacts. These impacting particles may not be of sufficient size to severe the tether, but they can easily be of sufficient size to damage the tether insulation. Samples of both the ProSEDS tether transition region and the insulated tether section (with various degrees of pinhole damage) were placed into the MSFC plasma chamber and biased to typical ProSEDS open circuit tether potentials (-500 V to -1600 V). The results of the testing showed that the transition region of the tether (i.e. the triple point) arced and burned the tether in two at -900 V, and the damaged insulated sections arced and burned in two between -1000 V and -1600, depending on the pinhole damage geometry. tether design and make the tether ready for flight. To reduce the pinhole arcing risk, ProSEDS mission operations were changed to eliminate the negative potential on the tether. The results of the testing campaign and the design changes implemented to ensure a successful flight will be described.

Vaughn, Jason A.↗

Modular In-Chamber Electron Beam Welding – Process Planning: Welding, Cladding, Inspection, and Manufacturing

Electron beam welding (EBW) is commonly employed by industry today to join relatively thin section components. Industrial sectors which utilize the technology include; automotive, aircraft, aerospace, defense, medical, oil & gas, etc. The ability to produce single pass, thick section (up to 6 inches, 150mm) welds has also been available for more than 40 years; however, the technology has not been deployed for civil nuclear manufacturing and fabrication such as reactor pressure vessels, steam generators, or pressurizers. Instead, thick section joining is performed much in the same manner it has been for decades using submerged arc or gas tungsten arc welding processes. Recent research performed under U.S. Department of Energy (DOE) project DE-NE0008629 has demonstrated that the overall welding time to produce one major reactor pressure vessel (RPV) girth weld can be reduced from weeks to less than 90 minutes, while maintaining exceptional quality and inspection characteristics. The subject project (DE-NE0008846) investigates a modular in-chamber (MIC) EBW approach which allows various RPV sections to be joined within a “modular” chamber. The MIC-EBW approach utilizes individual modules that can be stacked and de-stacked to various heights to enable production girth welds to be performed at a given elevation. This report describes the various processing methodology necessary to complete major girth weldments for the NuScale Power small modular reactor including welding development, manufacturing, production sequence, inspection, and cladding.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Photoelectron emission from metal surfaces induced by VUV-emission of filament driven hydrogen arc discharge plasma

Photoelectron emission measurements have been performed using a filament-driven multi-cusp arc discharge volume production H{sup −} ion source (LIISA). It has been found that photoelectron currents obtained with Al, Cu, Mo, Ta and stainless steel (SAE 304) are on the same order of magnitude. The photoelectron currents depend linearly on the discharge power. It is shown experimentally that photoelectron emission is significant only in the short wavelength range of hydrogen spectrum due to the energy dependence of the quantum efficiency. It is estimated from the measured data that the maximum photoelectron flux from plasma chamber walls is on the order of 1 A per kW of discharge power.

36 MATERIALS SCIENCE↗

SU-E-T-392: Evaluation of Ion Chamber/film and Log File Based QA to Detect Delivery Errors

Purpose: Ion chamber and film (ICAF) is a method used to verify patient dose prior to treatment. More recently, log file based QA has been shown as an alternative for measurement based QA. In this study, we delivered VMAT plans with and without errors to determine if ICAF and/or log file based QA was able to detect the errors. Methods: Using two VMAT patients, the original treatment plan plus 7 additional plans with delivery errors introduced were generated and delivered. The erroneous plans had gantry, collimator, MLC, gantry and collimator, collimator and MLC, MLC and gantry, and gantry, collimator, and MLC errors. The gantry and collimator errors were off by 4{sup 0} for one of the two arcs. The MLC error introduced was one in which the opening aperture didn’t move throughout the delivery of the field. For each delivery, an ICAF measurement was made as well as a dose comparison based upon log files. Passing criteria to evaluate the plans were ion chamber less and 5% and film 90% of pixels pass the 3mm/3% gamma analysis(GA). For log file analysis 90% of voxels pass the 3mm/3% 3D GA and beam parameters match what was in the plan. Results: Two original plans were delivered and passed both ICAF and log file base QA. Both ICAF and log file QA met the dosimetry criteria on 4 of the 12 erroneous cases analyzed (2 cases were not analyzed). For the log file analysis, all 12 erroneous plans alerted a mismatch in delivery versus what was planned. The 8 plans that didn’t meet criteria all had MLC errors. Conclusion: Our study demonstrates that log file based pre-treatment QA was able to detect small errors that may not be detected using an ICAF and both methods of were able to detect larger delivery errors.

60 APPLIED LIFE SCIENCES↗

A planning and delivery study of a rotational IMRT technique with burst delivery

Purpose: A novel rotational IMRT (rIMRT) technique using burst delivery (continuous gantry rotation with beam off during MLC repositioning) is investigated. The authors evaluate the plan quality and delivery efficiency and accuracy of this dynamic technique with a conventional flat 6 MV photon beam. Methods: Burst-delivery rIMRT was implemented in a planning system and delivered with a 160-MLC linac. Ten rIMRT plans were generated for five anonymized patient cases encompassing head and neck, brain, prostate, and prone breast. All plans were analyzed retrospectively and not used for treatment. Among the varied plan parameters were the number of optimization points, number of arcs, gantry speed, and gantry angle range (alpha) over which the beam is turned on at each optimization point. Combined rotational/step-and-shoot rIMRT plans were also created by superimposing multiple-segment static fields at several optimization points. The rIMRT trial plans were compared with each other and with plans generated using helical tomotherapy and VMAT. Burst-mode rotational IMRT plans were delivered and verified using a diode array, ionization chambers, thermoluminescent dosimeters, and film. Results: Burst-mode rIMRT can achieve plan quality comparable to helical tomotherapy, while the former may lead to slightly better OAR sparing for certain cases and the latter generally achieves slightly lower hot spots. Few instances were found in which increasing the number of optimization points above 36, or superimposing step-and-shoot IMRT segments, led to statistically significant improvements in OAR sparing. Using an additional rIMRT partial arc yielded substantial OAR dose improvements for the brain case. Measured doses from the rIMRT plan delivery were within 4% of the plan calculation in low dose gradient regions. Delivery time range was 228-375 s for single-arc rIMRT 200-cGy prescription with a 300 MU/min dose rate, comparable to tomotherapy and VMAT. Conclusions: Rotational IMRT with burst delivery, whether combined with static fields or not, yields clinically acceptable and deliverable treatment plans.

61 RADIATION PROTECTION AND DOSIMETRY↗

Commissioning and dosimetric characteristics of TrueBeam system: Composite data of three TrueBeam machines

Purpose: A TrueBeam linear accelerator (TB-LINAC) is designed to deliver traditionally flattened and flattening-filter-free (FFF) beams. Although it has been widely adopted in many clinics for patient treatment, limited information is available related to commissioning of this type of machine. In this work, commissioning data of three units were measured, and multiunit comparison was presented to provide valuable insights and reliable evaluations on the characteristics of the new treatment system. Methods: The TB-LINAC is equipped with newly designed waveguide, carousel assembly, monitoring control, and integrated imaging systems. Each machine in this study has 4, 6, 8, 10, 15 MV flattened photon beams, and 6 MV and 10 MV FFF photon beams as well as 6, 9, 12, 16, 20, and 22 MeV electron beams. Dosimetric characteristics of the three new TB-LINAC treatment units are systematically measured for commissioning. High-resolution diode detectors and ion chambers were used to measure dosimetric data for a range of field sizes from 10 Multiplication-Sign 10 to 400 Multiplication-Sign 400 mm{sup 2}. The composite dosimetric data of the three units are presented in this work. The commissioning of intensity modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT), image-guided radiation therapy, and gating systems are also illustrated. Critical considerations of P{sub ion} of FFF photon beams and small field dosimetric measurements were investigated. Results: The authors found all PDDs and profiles matched well among the three machines. Beam data were quantitatively compared and combined through average to yield composite beam data. The discrepancies among the machines were quantified using standard deviation (SD). The mean SD of the PDDs among the three units is 0.12%, and the mean SD of the profiles is 0.40% for 10 MV FFF open fields. The variations of P{sub ion} of the chamber CC13 is 1.2 {+-} 0.1% under 6 MV FFF and 2.0 {+-} 0.5% under 10 MV FFF from dmax to the 18 cm-off-axis point at 35 cm depth under 40 Multiplication-Sign 40 cm{sup 2}. The mean penumbra of crossplane flattened photon beams at collimator angle of 0 Degree-Sign is measured from 5.88 {+-} 0.09 to 5.99 {+-} 0.13 mm from 4 to 15 MV at 10 cm depth of 100 Multiplication-Sign 100 mm{sup 2}. The mean penumbra of crossplane beams at collimator angle of 0 Degree-Sign is measured as 3.70 {+-} 0.21 and 4.83 {+-} 0.04 mm for 6 MV FFF and 10 MV FFF, respectively, at 10 cm depth with a field size of 5 Multiplication-Sign 5 cm{sup 2}. The end-to-end test procedures of both IMRT and VMAT were performed for various energy modes. The mean ion chamber measurements of three units showed less than 2% between measurement and calculation; the mean MultiCube ICA measurements demonstrated over 90% pixels passing gamma analysis (3%, 3 mm, 5% threshold). The imaging dosimetric data of KV planar imaging and CBCT demonstrated improved consistency with vendor specifications and dose reduction for certain imaging protocols. The gated output verification showed a discrepancy of 0.05% or less between gating radiation delivery and nongating radiation delivery. Conclusions: The commissioning data indicated good consistency among the three TB-LINAC units. The commissioning data provided us valuable insights and reliable evaluations on the characteristics of the new treatment system. The systematically measured data might be useful for future reference.

07 ISOTOPE AND RADIATION SOURCES↗

TH-C-12A-04: Dosimetric Evaluation of a Modulated Arc Technique for Total Body Irradiation

Purpose: A simplified Total Body Irradiation (TBI) was developed to work with minimal requirements in a compact linac room without custom motorized TBI couch. Results were compared to our existing fixed-gantry double 4 MV linac TBI system with prone patient and simultaneous AP/PA irradiation. Methods: Modulated arc irradiates patient positioned in prone/supine positions along the craniocaudal axis. A simplified inverse planning method developed to optimize dose rate as a function of gantry angle for various patient sizes without the need of graphical 3D treatment planning system. This method can be easily adapted and used with minimal resources. Fixed maximum field size (40×40 cm2) is used to decrease radiation delivery time. Dose rate as a function of gantry angle is optimized to result in uniform dose inside rectangular phantoms of various sizes and a custom VMAT DICOM plans were generated using a DICOM editor tool. Monte Carlo simulations, film and ionization chamber dosimetry for various setups were used to derive and test an extended SSD beam model based on PDD/OAR profiles for Varian 6EX/ TX. Measurements were obtained using solid water phantoms. Dose rate modulation function was determined for various size patients (100cm − 200cm). Depending on the size of the patient arc range varied from 100° to 120°. Results: A PDD/OAR based beam model for modulated arc TBI therapy was developed. Lateral dose profiles produced were similar to profiles of our existing TBI facility. Calculated delivery time and full arc depended on the size of the patient (∼8min/ 100° − 10min/ 120°, 100 cGy). Dose heterogeneity varied by about ±5% − ±10% depending on the patient size and distance to the surface (buildup region). Conclusion: TBI using simplified modulated arc along craniocaudal axis of different size patients positioned on the floor can be achieved without graphical / inverse 3D planning.

60 APPLIED LIFE SCIENCES↗

Calculated and Measured Dose Distributions in an Anthropomorphic RANDO Phantom - Paper 105

Patient-specific quality assurance (QA) is a major component of the Intensity Modulated Radiation Therapy (IMRT) clinical process. The objective of this often time-intensive measurement process is to verify that the prescribed dose is accurately delivered to the target volume while sparing surrounding healthy tissue. The IMRT dose distributions can be measured using a wide variety of techniques and measurement devices including film (radiographic and radiochromic), ion chamber arrays, diode arrays, and Electronic Portal Imaging Devices (EPIDs). Of all the available modalities, film is one of the most versatile and most frequently utilized measurement systems. In rotation delivery techniques (such as volume modulated arc therapy and helical tomotherapy), composite dose distributions are obtained by irradiating a test phantom containing dosimeter(s). When film is utilized as the dosimeter, it can be placed in coronal, sagittal, or transverse planes inside the phantom. Because the film is irradiated using the rotational delivery sequence used to treat the patient, the dose given to specific anatomical structures (such as the parotids, spinal cord, bladder, rectum etc...) can be evaluated. Thomas et al (Med Phys 32: 3793-3800) recently reported the results of IMRT verifications for ten patients planned and treated with helical tomotherapy. This study reported that nearly 92% of the film pixels within the analyzed region of interest were within a gamma criterion of 2 mm and 2%. Like most tomotherapy users, Thomas et al used a test phantom made of homogeneous water equivalent material. Heterogeneous phantoms that simulate the different tissue densities in the human body do exist, but are infrequently used for patient-specific IMRT QA. The potential advantage of using heterogeneous phantoms is that the measured dose distributions will more adequately reflect the clinical dose distributions in the patients. The use of homogenous phantoms during IMRT quality assurance can potentially mask errors that arise from limitations in the treatment planning system's modeling of density corrections. The purpose of this study was to evaluate the dosimetric accuracy of a helical tomotherapy system using an anthropomorphic RANDO phantom (The Phantom Laboratory, Salem, NY) for patient-specific QA. The results of this study will allow a benchmark to be established for dosimetric accuracy in heterogeneous materials. Performing patient-specific QA is an integral part of the IMRT patient treatment process. Test phantoms are typically homogeneous, and do test the treatment planning systems ability to account for heterogeneity corrections. In this study, an anthropomorphic RANDO phantom was used to evaluate the doses calculated by a helical tomotherapy system. The dosimetric agreement between calculated and measured was worse than published results in homogenous phantoms, especially for target volumes located in the lung. Further investigation will be needed to determine if these errors are due to film response at heterogeneous tissue interfaces or from actual dose calculation errors. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

How an Electron Beam (Eventually) Penetrates Ceramic Cloth

In anticipation of the International Space Welding Experiment (ISWE) the effect of an electron beam was investigated on Nextel AF-62 ceramic cloth designed to withstand temperatures up to 1427 C. It was anticipated that the cloth would take a static charge that would repel the beam and remain undamaged. It was found that after some seconds the impinging beam penetrated penetrated the cloth. Further, the penetration time went up significantly both at longer and at closer standoff distances. A tentative explanation appears to fit the observed facts. The electrons in the beam generate positive ions by collisions with the contaminant gas molecules in the vacuum chamber. The positive ions transfer a small but significant fraction of the beam power to the cloth. Under the impingement of the positive ions the cloth heats up until sufficient outgassing occurs to initiate arcing. Once arcing occurs the full beam power impinges on the cloth and, almost instantaneously, burns a hole.

Nunes, A. C., Jr.↗

Dosimetric aspects of inverse-planned modulated-arc total-body irradiation

Purpose: To develop optimal beam parameters and to verify the dosimetric aspects of the recently developed modulated-arc total-body irradiation (MATBI) technique, which delivers an inverse-planned dose to the entire body using gantry rotation. Methods: The patient is positioned prone and supine underneath the gantry at about 2 m source-to-surface distance (SSD). Then, up to 28 beams irradiate the patient from different gantry angles. Based on full-body computed-tomography (CT) images of the patient, the weight of each beam is optimized, using inverse planning, to create a uniform body dose. This study investigates how to best simulate patients and the ideal beam setup parameters, such as field size, number of beams, and beam geometry, for treatment time and dose homogeneity. In addition, three anthropomorphic water phantoms were constructed and utilized to verify the accuracy of dose delivery, with both diode array and ion chamber measurements. Furthermore, to improve the accuracy of the new technique, a beam model is created specifically for the extended-SSD positioning for MATBI. Results: Low dose CT scans can be utilized for dose calculations without affecting the accuracy. The largest field size of 40 Multiplication-Sign 40 cm{sup 2} was found to deliver the most uniform dose in the least amount of time. Moreover, a higher number of beams improves dose homogeneity. The average dose discrepancy between ion chamber measurements and extended-SSD beam model calculations was 1.2%, with the largest discrepancy being 3.2%. This average dose discrepancy was 1.4% with the standard beam model for delivery at isocenter. Conclusions: The optimum beam setup parameters, regarding dose uniformity and treatment duration, are laid out for modulated-arc TBI. In addition, the presented dose measurements show that these treatments can be delivered accurately. These measurements also indicated that a new beam model did not significantly improve the accuracy of dose calculations. The optimum beam setup parameters along with the measurements performed to ensure accurate dose delivery serve as a useful guide for the clinical implementation of MATBI.

60 APPLIED LIFE SCIENCES↗

A synthetic diamond diode in volumetric modulated arc therapy dosimetry

Purpose: The aim of this work is to investigate the behavior of a single crystal diamond diode (SCDD) for volumetric modulated arc therapy (VMAT) dose verifications. This delivery technique is one of the most severe test of a dosimeter performance due to the modulation of the dose rate achieved by simultaneously changing the velocity of the gantry and the position of the collimator leaves. The performed measurements with VMAT photon beams can therefore contribute to an overall global validation of the device to be used in dose distribution verifications.Methods: The SCDD response to 6 MVRX has been tested and compared with reference ionization chambers and treatment planning system (TPS) calculations in different experiments: (a) measurements of output factors for small field sizes (square fields of side ranging between 8 mm and 104 mm) by SCDD and A1SL ionization chamber; (b) angular dependence evaluation of the entire experimental set-up by SCDD, A1SL, and Farmer ionization chambers; and (c) acquisition of dose profiles for a VMAT treatment of a pulmonary disease in latero-lateral and gantry-target directions by SCDD and A1SL ionization chamber.Results: The output factors measured by SCDD favorably compare with the ones obtained by A1SL, whose response is affected by the lack of charged particle equilibrium and by averaging effect when small fields are involved. From the experiment on angular dependence, a good agreement is observed among the diamond diode, the ion chambers, and the TPS. In VMAT profiles, the absorbed doses measured by SCDD and A1SL compare well with the TPS calculated ones. An overall better agreement is observed in the case of the diamond dosimeter, which is also showing a better accuracy in terms of distance to agreement in the high gradient regions.Conclusions: Synthetic diamond diodes, whose performance were previously studied for conformal and IMRT radiotherapy techniques, were found to be suitable detectors also for dosimetric measurements in volumetric arc therapy treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hollow cathode, quasi-steady MPD arc

A quasi-steady MPD accelerator has been operated with four different hollow cathodes over a power range from 5 kilowatts to 5 megawatts. The absolute level of the argon mass flow, as well as the fractional division of the flow between the cathode and the six standard chamber injectors, is varied over a range of 1 to 12 grams per second. For a fixed total current, it is observed that the voltage increases monotonically with mass flow rate, compared to the usual experience with solid cathodes where the voltage decreases with mass flow rate. For a fixed percentage of flow through the cathode, each hollow cathode configuration displays a minimum impedance at a particular value of the total mass flow. It is asserted that in order to keep the discharge inside the hollow cathode the magnetic pressure and gasdynamic pressure have to match inside the cavity.

Parmentier, N.↗

Synthesis of TiO{sub 2} Nanoparticles from Ilmenite Through the Mechanism of Vapor-Phase Reaction Process by Thermal Plasma Technology

Synthesis of nanoparticles of TiO{sub 2} was carried out by non-transferred arc thermal plasma reactor using ilmenite as the precursor material. The powder ilmenite was vaporized at high temperature in plasma flame and converted to a gaseous state of ions in the metastable phase. On cooling, chamber condensation process takes place on recombination of ions for the formation of nanoparticles. The top-to-bottom approach induces the disintegration of complex ilmenite phases into simpler compounds of iron oxide and titanium dioxide phases. The vapor-phase reaction mechanism was carried out in thermal plasma zone for the synthesis of nanoparticles from ilmenite compound in a plasma reactor. The easy separation of iron particles from TiO{sub 2} was taken place in the plasma chamber with deposition of light TiO{sub 2} particles at the top of the cooling chamber and iron particles at the bottom. The dissociation and combination process of mechanism and synthesis are studied briefly in this article. The product TiO{sub 2} nanoparticle shows the purity with a major phase of rutile content. TiO{sub 2} nanoparticles produced in vapor-phase reaction process shows more photo-induced capacity.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Calibration of radiation detectors in the ultraviolet region between 972 and 2500 A

The development of experimental setups and procedures is considered for calibrating photosensitive devices in the spectral range 1022 to 2500 A for which no direct calibration techniques exist. An indirect technique that uses a sodium salicylate detector calibrated outside this range was developed for use as a secondary standard. The primary standard was a xenon-filled ionization chamber, which is an absolute standard over the wavelength interval 972 to 1022 A. Measurements made by this method were checked at 1470 A with a xenon lamp and at 2537 A with a mercury arc lamp and a 0.5 m blaze monochromator with a grating blazed at 2000 A. The overall accuracy of the measurements was + or - 40 percent or better.

Mcclenahan, J. O.↗