Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ANALOG PROCESSING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Upgrade to Fixed and Translating Scintillation-Based Loss Detector System in the Fermilab Drift Tube Linac

The closed-off structure of the Fermilab Drift Tube Linac precludes a robust array of instrumentation from directly monitoring the H- beam that is accelerated from 750 keV to 116 MeV. To improve beam tuning and op-erational assessment of Drift Tube Linac performance, scintillator-based loss monitors were previously installed along the exterior of the first two accelerating cavities to assess low energy beam losses. Here we present a recent upgrade to the loss monitor system, including significant improvements in analog signal processing to address baseline-interfering noise; digitization of the signals to enable regular operational use and tuning; and a new remote operation upgrade of the translating loss monitor with precise positioning of the loss monitor along its nine-foot track. Data from the fixed and translating de-tectors collected under varying beam conditions validate the utility of the upgrade.

Chen, Erin V. [Fermilab] (ORCID:0000000215467899)↗

Microwave treatment of a brown coal concentrate from Mugunsk coal for the manufacture of sponge iron

A technique for the production of a finely dispersed dry brown coal concentrate with the use of microwave energy is proposed to prepare a charge mixture for the manufacture of sponge iron. The advantages of this technique over analogous industrial processes are demonstrated. The results of experiments on the briquetting of the charge mixture of brown coal and iron ore concentrates without the use of an additional binding agent are described.

01 COAL, LIGNITE, AND PEAT↗

Design of a high-speed real-time symbiont

The problems involved, approach taken, and solution arrived at are described in a software study to design a high speed, real time symbiont for analog telemetry processing. The symbiont design is based on the need for transferring data from one I/O device to another without significant use of core space or central processor time. The queues, programmed wait states, and teletype commands incorporated in the symbiont design are discussed.

Grunby, E. I.↗

Digital single-sideband modulation.

This paper considers digitized Weaver modulators for single-sideband modulation that can be used in radio communications and telemetering. A system of 12 such modulators to process 12 analog signals digitally is replaced by six multiplex modulators at the cost of additional computation at the input but with an overall reduction in computation time and a higher degree of accuracy. A unique digital filter is developed that can interpolate and output samples at multiples of the input sampling rate and exhibits a passband that occurs above the Nyquist frequency with no apparent distortion effects. A discussion of the Fortran simulation of a combined modulator-demodulator structure is included to verify the effectiveness of this scheme.

Singh, S.↗

A high-accuracy digital star tracker for advanced planetary missions.

The digital star tracker represents a novel departure from previous analog designs in terms of circuit implementation and operational capabilities. As an element of an all-digital spacecraft control system, it combines proven low-level analog signal processing with digital error control and command functions. Additional capabilities that are obtainable with the digital circuitry include programmable intensity threshold gates, commanded electronic pointing control, and an acquisition/control algorithm which minimizes the effects of straylight disturbances. The capabilities inherent in the implementation have been successfully demonstrated in a laboratory model of the instrument.

Salomon, P. M.↗

A high-accuracy digital star tracker for advanced planetary missions

The digital star tracker represents a novel departure from previous analog designs in terms of circuit implementation and operational capabilities. As an element of an all-digital spacecraft control system, it combines proven low-level analog signal processing with digital error control and command functions. Additional capabilities that are obtainable with the digital circuitry include programmable intensity threshold gates, commanded electronic pointing control, and an acquisition/control algorithm which minimizes the effects of straylight disturbances. The capabilities inherent in the implementation have been successfully demonstrated in a laboratory model of the instrument.

Salomon, P. M.↗

Hybrid measurement chains for the SAS-C spacecraft

Spacecraft electronic systems usually demand tight packaging. It was this consideration which initially forced us to consider hybrid circuits for the analog signal processing circuits in the Small Astronomy Satellite-C (SAS-C) scientific payload. We gradually discovered that increased reliability, low power consumption, and reduced program costs all followed. This paper will attempt to share our laboratory's first experience with hybrid circuits and indicate those areas which we found to be important.

Goeke, R. F.↗

Development and investigation of single-scan TV radiography for the acquisition of dynamic physiologic data

A light amplifier for large flat screen fluoroscopy was investigated which will decrease both its size and weight. The work on organ contouring was extended to yield volumes. This is a simple extension since the fluoroscopic image contains density (gray scale) information which can be translated as tissue thickness, integrated, yielding accurate volume data in an on-line situation. A number of devices were developed for analog image processing of video signals, operating on-line in real time, and with simple selection mechanisms. The results show that this approach is feasible and produces are improvement in image quality which should make diagnostic error significantly lower. These are all low cost devices, small and light in weight, thereby making them usable in a space environment, on the Ames centrifuge, and in a typical clinical situation.

Baily, N. A.↗

Real-time radiographic inspection facility

A real time radiographic inspection facility has been developed for nondestructive evaluation applications. It consists of an X-ray source, an X-ray sensitive television imaging system, an electronic analog image processing system, and a digital image processing system. The digital image processing system is composed of a computer with the necessary software to drive the overall facility. Descriptions are given of the design strategy, the facility's components, and its current capabilities.

Roberts, E., Jr.↗

Satellite onboard feature classification using CCD's

In this paper discrete time analog signal processing applications of CCD's are discussed. The types of computations which can be performed in the CCD technology are discussed and compared with respect to their accuracy and required support hardware. The classification problem encountered in the reduction of multispectral data into features of terrestrial interest are decomposed into a CCD technology based hardware solution. The resulting system is readily implemented with existing and anticipated CCD devices. This system will be projected to spacecraft application.

Benz, H. F.↗

Non-thermal hydrogen in the Venus exosphere - The ionospheric source and the hydrogen budget

A nonthermal, or 'hot', Venus corona of H atoms has been observed by Mariners 5 and 10 and Venera 9. Of the sources investigated, reaction of H2 with ionospheric O(+) is still the strongest. It can explain the smaller densities but falls somewhat short of the largest (from Mariner 5). The subsequent recombination of OH(+), supplemented by solar-wind processes, may give an escape flux of 10 million atoms per sq cm/s. The low density of thermal H atoms on the day side has previously been attributed to either a large eddy diffusion coefficient or an escape flux tenfold greater than this. An alternative mechanism, suggested by Hartle and Mayr (1977) is supported: the hydrogen is swept to the night side by strong thermospheric winds. This process is analogous to the 'Johnson pump' for the terrestrial winter helium bulge. Large nightside bulges of H and H2 are predicted; the night/day density ratio is estimated to be as large as 100 for each.

Kumar, S.↗

Microprocessor-based cardiotachometer

Instrument operates reliably even with stress-test electrocardiogram (ECG) signals subject to noise, baseline wandering, and amplitude change. It records heart rate from preamplified, single-lead ECG input signal and produces digital and analog heart-rate outputs which are fed elsewhere. Analog hardware processes ECG input signal, producing 10-ms pulse for each heartbeat. Microprocessor analyzes resulting pulse train, identifying irregular heartbeats and maintaining stable output during lead switching. Easily modified computer program provides analysis.

Crosier, W. G.↗

Discrimination of form in images corrupted by speckle

The problem investigated is that of a human observer having to distinguish between certain specified geometrical forms corrupted by speckle - an idealization of the problem of a scientist studying a synthetic aperture radar map. Specifically, the cases of two simple alternative forms and of two and four orientations of a simple form have been considered. A theoretical model is developed for the observer's decision process by analogy with optimal receiver theory, and the probability of a correct decision is related to form parameters like size, contrast, and looks. These calculations are verified by psychophysical experiments using computer-simulated pictures.

Korwar, V. N.↗

Upgrading and performance of the SAO laser ranging system in Matera

The performance of the SAO lasers was improved considerably in terms of accuracy, range noise, data yield, and reliability. With the narrower laser pulse (2.5-3.0 nsec) and a new analog pulse processing system, the systematic range errors were reduced to 3-5 cm and range noise has been reduced to 5-15 cm on low satellites and 10-18 cm on Lageos. Pulse repetition rate was increased to 30 ppm and considerable improvement has been made in signal-to-noise ratio by using a 3 Angstrom interference filter and by reducing the range gate window down to 200-400 nsec. The first upgraded system was installed in Arequipa, Peru in the spring of 1982. The second upgraded system is now in operation in Matera, Italy. The third system is expected to be installed in Israel during 1984.

Maddox, J.↗

Satellite tracking and Earth dynamics research programs

Following an upgrading program, ranging performance capabilities of a satellite-tracking pulsed laser system were assessed in terms of range accuracy, range noise, data yield, and reliability. With a shorter laser pulse duration (2.5 to 3.0 NSEC) and a new analog pulse processing system, the systematic range errors were reduced to 3 to 5 cm and range noise was reduced to 5 to 16 cm and range noise was reduced to 5 to 15 cm on Starlette and BE-C, and 10 to 18 cm on LAGEOS. Maximum pulse repetition rate was increased to 30 pulses per minute and significant improvement was made in signal to noise ratio by installing a 3 A interference filter and by reducing the range gate window to 200 to 400 nsec. The solution to a problem involving leakage of a fraction of the laser oscillator pulse through the pulse chopper was outlined.

Pearlman, M. R.↗

Burst size distributions in the digitized data of the ion chambers t Mt. Norikura and sea level stations

A practical and simple method for burst rejection is applied to the digitized data of cosmic ray ion chambers at Mt. Norikura, Tokyo and Kochi. As a result of burst rejection, the burst size frequency distributions in the digitized data at mountain altitude and sea level ion chambers is obtained. Results show that there are no significant differences between the digital and analog data processing in burst rejection.

Kusunose, M.↗