Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AMES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

PAH EMISSION AT THE BRIGHT LOCATIONS OF PDRs: THE grandPAH HYPOTHESIS

The polycyclic aromatic hydrocarbon (PAH) emission observed in the Spitzer Infrared Spectrograph spectra of bright mid-IR locations of NGC 7023, NGC 2023, and NGC 1333 was analyzed. These objects show large variations in PAH band ratios when studied through spectral mapping. Nevertheless, the mid-IR spectra at these bright spots show a remarkably similar PAH emission. We used the NASA Ames PAH IR Spectroscopic Database to fit the observations and analyze the derived PAH populations. Our results show that PAH emission in the 5–15 μm range appears to be rather insensitive to variations of the radiation field. Similar PAH populations of neutral small to medium-sized PAHs (∼50%), with ionized species contributing in slightly less than 50%, provide very good fits. Analyzing the degeneracy of the results shows that subtle (but intrinsic) variations in the emission properties of individual PAHs lead to observable differences in the resulting spectra. On top of this, we found that variations of <30% in the PAH abundances would lead to noticeable spectral differences between the three photodissociation regions (PDRs). Therefore, PAH populations must be remarkably similar at these different lines of sight. To account for this, we suggest the concept of grandPAHs as a unique mixture of the most stable PAHs emitting at these spots. Using NGC 7023 as an example, the grandPAHs refer to the robust PAH population that results from the intense processing of PAHs at the border limit between the PDR and the molecular cloud, where, due to the UV radiation that destroys the PAH population, the abundance of PAHs starts decreasing as we move toward the star.

79 ASTRONOMY AND ASTROPHYSICS↗

POLYCYCLIC AROMATIC HYDROCARBONS WITH ARMCHAIR EDGES AND THE 12.7 μm BAND

In this Letter, we report the results of density functional theory calculations on medium-sized neutral polycyclic aromatic hydrocarbon (PAH) molecules with armchair edges. These PAH molecules possess strong C-H stretching and bending modes around 3 μm and in the fingerprint region (10-15 μm), and also strong ring deformation modes around 12.7 μm. Perusal of the entries in the NASA Ames PAHs Database shows that ring deformation modes of PAHs are common, although generally weak. Therefore, we propose that armchair PAHs with N{sub C} > 65 are responsible for the 12.7 μm aromatic infrared band in H II regions and discuss the astrophysical implications in the context of the PAH life cycle.

79 ASTRONOMY AND ASTROPHYSICS↗

Natural variation and improved genome annotation of the emerging biofuel crop field pennycress ( Thlaspi arvense )

The Brassicaceae family comprises more than 3,700 species with a diversity of phenotypic characteristics, including seed oil content and composition. Recently, the global interest in Thlaspi arvense L. (pennycress) has grown as the seed oil composition makes it a suitable source for biodiesel and aviation fuel production. However, many wild traits of this species need to be domesticated to make pennycress ideal for cultivation. Molecular breeding and engineering efforts require the availability of an accurate genome sequence of the species. Here, we describe pennycress genome annotation improvements, using a combination of long- and short-read transcriptome data obtained from RNA derived from embryos of 22 accessions, in addition to public genome and gene expression information. Our analysis identified 27,213 protein-coding genes, as well as on average 6,188 biallelic SNPs. In addition, we used the identified SNPs to evaluate the population structure of our accessions. The data from this analysis support that the accession Ames 32872, originally from Armenia, is highly divergent from the other accessions, while the accessions originating from Canada and the United States cluster together. When we evaluated the likely signatures of natural selection from alternative SNPs, we found 7 candidate genes under likely recent positive selection. These genes are enriched with functions related to amino acid metabolism and lipid biosynthesis and highlight possible future targets for crop improvement efforts in pennycress.

59 BASIC BIOLOGICAL SCIENCES↗

Collapse of magnetized white dwarfs as site of heavy-element formation and kilonova signal

We present the first end-to-end calculation connecting the accretion-induced collapse (AIC) of a magnetized, rapidly rotating white dwarf to observable kilonova signatures, combining two-dimensional (2D) general-relativistic neutrino-magnetohydrodynamic simulations, followed by radiation hydrodynamics with in-situ nuclear network and 2D Monte Carlo radiative transfer with spatially resolved heating rates. Unlike all previous unmagnetized AIC models – which predicted proton-rich, $^{56}$Ni-dominated ejecta – strong magnetic fields eject ${\approx }\, 0.2\, \mathrm{ M}_\odot$ of neutron-rich material ($\langle Y_e \rangle \sim 0.24$) on dynamical time-scales, before neutrino irradiation can raise the electron fraction, enabling strong r-process nucleosynthesis up to and beyond the third peak. The resulting kilonova is lanthanide-rich ($X_{\rm lan} \approx 8~{{\ \rm per\ cent}}$) and dominated by near-infrared emission. We compute synthetic light curves in the Large Synoptic Survey Telescope and J ames Webb Space Telescope bands and find striking agreement, without parameter tuning, between the observations of AT 2023vfi/GRB 230307A and our broadband light curves for polar viewing angles. These results establish magnetized AIC as a viable channel for heavy r-process element production and a compelling progenitor candidate for long-duration gamma-ray bursts with kilonova signatures.

MHD↗

Mass measurement of 51 Fe for the determination of the 51 Fe($p, γ$) 52 Co reaction rate

Background: The 51 Fe(p, γ) 52 Co reaction lies along the main rp-process path leading up to the 56 Ni waiting point. The uncertainty in the reaction Q value, which determines the equilibrium between the forward protoncapture and reverse photodisintegration 52 Co(γ,p) 51 Fe reaction, contributes to considerable uncertainty in the reaction rate in the temperature range of interest for Type I x-ray bursts and thus to an ≈10% uncertainty in burst ashes lighter than A = 56. Purpose: With a recent Penning trap mass measurement of 52 Co reducing the uncertainty on its mass to 6.6 keV [Nesterenko et al., J. Phys. G 44, 065103 (2017)], the dominant source of uncertainty in the reaction Q value is now the mass of 51 Fe, reported in the 2016 atomic mass evaluation to a precision of 9 keV [Wang et al., Chin.Phys. C 41, 030003 (2017)]. A new, high-precision Penning trap mass measurement of 51 Fe was performed to allow the determination of an improved precision Q value and thus new reaction rates. Method: 51 Fe was produced using projectile fragmentation at the Coupled Cyclotron Facility at the National Superconducting Cyclotron Laboratory, and separated using the A1900 fragment separator. The resulting secondary beam was then thermalized in the beam stopping area before a mass measurement was performed using the LEBIT 9.4T Penning trap mass spectrometer. Results: The new mass excess, ME = -40189.2(1.6) keV, is sixfold more precise than the current AME value, and 1.6σ less negative. This value was used to calculate a new proton separation energy for 52 Co of 1431(7) keV. New excitation levels were then calculated for 52 Co using the NUSHELLX code with the GXPF1A interaction, and a new reaction rate and burst ash composition was calculated. Conclusions:With a new measured Q value, the uncertainty on the 51 Fe(p, γ ) reaction rate is dominated by the poorly measured 52 Co level structure. Finally, reducing this uncertainty would allow a more precise rate calculation and a better determination of the mass abundances in the burst ashes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Resolution-induced anisotropy in large-eddy simulations

Large-eddy simulation (LES) of turbulence in complex geometries and domains is often conducted with high-aspect-ratio resolution cells of varying shapes and orientations. The effects of such anisotropic resolution are often simplified or neglected in subgrid model formulations. In this study, we examine resolution-induced anisotropy and demonstrate that even for isotropic turbulence, anisotropic resolution induces mild resolved Reynolds stress anisotropy and significant anisotropy in second-order resolved velocity gradient statistics. In large-eddy simulations of homogeneous isotropic turbulence with anisotropic resolution, it is shown that commonly used subgrid models, including those that consider resolution anisotropy in their formulation, perform poorly. The one exception is the anisotropic minimum dissipation model proposed by Rozema et al. [Phys. Fluids 27, 085107 (2015)]. A simple model is presented here that is an anisotropic eddy diffusivity extension of the “Kolmogorov expression” eddy viscosity of Carati et al. [A family of dynamic models for large-eddy simulation, in Annual Research Briefs, Center for Turbulence Research (Stanford University and NASA AMES, 1995), pp. 35–40] that depends explicitly on the anisotropy of the resolution. It also performs well and is remarkable because, unlike other LES subgrid models, the eddy diffusivity only depends on statistical characteristics of the turbulence (in this case, the dissipation rate), not on fluctuating quantities. In other subgrid modeling formulations, such as the dynamic procedure, limiting flow dependence to statistical quantities in this way could have advantages.

42 ENGINEERING↗

Comparative analysis of internal energy excitation and dissociation of nitrogen predicted by independently developed ab initio potential energy surfaces

In this article we present a comparative atomic level study analyzing the vibrational excitation and dissociation of molecular nitrogen due to N 2 ⁢( 1 Σ g ⁢ + )+N⁢( 4 S u ) and N 2 ⁢( 1 Σ g ⁢ + )+N 2 ⁢( 1 Σ g ⁢+ ) interactions governed by independently developed potential energy surfaces at the University of Minnesota and NASA Ames Research Center. Further, vibrational excitation was studied for N 2 +N 2 interactions from T=10000 to 25000 K and for N 2 +N from T=5000 to 30000 K. Nonequilibrium dissociation is studied from T=10000 to 30000 K under the quasi-steady-state condition for N 2 +N 2 and N 2 +N interactions. Finally, an inviscid Mach 20 dissociating nitrogen flow over a cylinder with a Knudsen number of 0.015 is carried out to study the impact of molecular interactions predicted by independently developed potential energy surfaces on a canonical hypersonic flow.

74 ATOMIC AND MOLECULAR PHYSICS↗

Sparse Symmetric Format for Tucker Decomposition

Tensor-based methods are receiving renewed attention in recent years due to their prevalence in diverse real-world applications. There is considerable literature on tensor representations and algorithms for tensor decompositions, both for dense and sparse tensors. Many applications in hypergraph analytics, machine learning, psychometry, and signal processing result in tensors that are both sparse and symmetric, making them an important class for further study. Similar to the critical Tensor Times Matrix chain operation (TTM c ) in general sparse tensors, the $\underline{S}$ parse $\underline{S}$ ymmetric $\underline{T}$ ensor $\underline{T}$ imes $\underline{S}$ ame $\underline{M}$ atrix $\underline{c}$ hain (S 3 TTM c ) operation is compute and memory intensive due to high tensor order and the associated factorial explosion in the number of non-zeros. We present the novel Compressed Sparse Symmetric (CSS) format for sparse symmetric tensors, along with an efficient parallel algorithm for the S 3 TTM c operation. We theoretically establish that S 3 TTM c on CSS achieves a better memory versus run-time trade-off compared to state-of-the-art implementations, and visualize the variation of the performance gap over the parameter space. We demonstrate experimental findings that confirm these results and achieve up to 2.72× speedup on synthetic and real datasets. The scaling of the algorithm on different test architectures is also showcased to highlight the effect of machine characteristics on algorithm performance.

42 ENGINEERING↗

Systematic Assessment of Terrestrial Biogeochemistry in Coupled Climate-Carbon Models

With representation of the global carbon cycle becoming increasingly complex in climate models, it is important to develop ways to quantitatively evaluate model performance against in situ and remote sensing observations. Here we present a systematic framework, the Carbon-LAnd Model Intercomparison Project (C-LAMP), for assessing terrestrial biogeochemistry models coupled to climate models using observations that span a wide range of temporal and spatial scales. As an example of the value of such comparisons, we used this framework to evaluate two biogeochemistry models that are integrated within the Community Climate System Model (CCSM) - Carnegie-Ames-Stanford Approach (CASA) and carbon-nitrogen (CN). Both models underestimated the magnitude of net carbon uptake during the growing season in temperate and boreal forest ecosystems, based on comparison with atmospheric CO{sub 2} measurements and eddy covariance measurements of net ecosystem exchange. Comparison with MODerate Resolution Imaging Spectroradiometer (MODIS) measurements show that this low bias in model fluxes was caused, at least in part, by 1-3 month delays in the timing of maximum leaf area. In the tropics, the models overestimated carbon storage in woody biomass based on comparison with datasets from the Amazon. Reducing this model bias will probably weaken the sensitivity of terrestrial carbon fluxes to both atmospheric CO{sub 2} and climate. Global carbon sinks during the 1990s differed by a factor of two (2.4 Pg C yr{sup -1} for CASA vs. 1.2 Pg C yr{sup -1} for CN), with fluxes from both models compatible with the atmospheric budget given uncertainties in other terms. The models captured some of the timing of interannual global terrestrial carbon exchange during 1988-2004 based on comparison with atmospheric inversion results from TRANSCOM (r=0.66 for CASA and r=0.73 for CN). Adding (CASA) or improving (CN) the representation of deforestation fires may further increase agreement with the atmospheric record. Information from C-LAMP has enhanced model performance within CCSM and serves as a benchmark for future development. We propose that an open source, community-wide platform for model-data intercomparison is needed to speed model development and to strengthen ties between modeling and measurement communities. Important next steps include the design and analysis of land use change simulations (in both uncoupled and coupled modes), and the entrainment of additional ecological and earth system observations. Model results from C-LAMP are publicly available on the Earth System Grid.

09 BIOMASS FUELS↗

Novel transparent electrodes allow sustainable production of electronic devices

A novel technique for fabricating inexpensive, transparent electrodes from common metals has been developed by engineers and scientists at Iowa State University and Ames Laboratory. They exhibit very high transparency and are very good electrical conductors. This is a combination of properties that is difficult to achieve with common materials. The most frequently used transparent electrode in today's high-technology devices (such as LCD screens) is indium tin oxide (ITO). While ITO performs well in these applications, the supply of indium is very limited. In addition, it is rapidly decreasing as consumer demand for flat-panel electronics is skyrocketing. According to a 2004 US Geological Survey report, as little as 14 years exploitation of known indium reserves remains. In addition to increasing prices, the dwindling supply of indium suggests its use is not sustainable for future generations of electronics enthusiasts. Solar cells represent another application where transparent electrodes are used. To make solar-energy collection economically feasible, all parts of solar photovoltaics must be made more efficient and cost-effective. Our novel transparent electrodes have the potential to do both. In addition, there is much interest in developing more efficient, cost-effective, and environmentally friendly lighting. Incandescent light bulbs are very inefficient, because most of their energy consumption is wasted as heat. Fluorescent lighting is much more efficient but still uses mercury, an environmental toxin. An attractive alternative is offered by LEDs, which have very high efficiencies and long lifetimes, and do not contain mercury. If made bright enough, LED use for general lighting could provide a viable alternative. We have fabricated electrodes from more commonly available materials, using a technique that is cost effective and environmentally friendly. Most of today's electronic devices are made in specialized facilities equipped with low-particle-count clean-room facilities and multimillion-dollar equipment. On the other hand, the novel process we developed uses a method that makes use of polymer molds and standard deposition techniques in an ambient laboratory environment. The final structure consists of tall ribbons of metal (standing on edge) that are so thin that they do not block light but are very good conductors. The advantage of this design is that it avoids the competition between conductivity and transparency inherent in transparent oxide electrodes. By making the structure taller, conductivity can be increased without impacting transparency. We have measured both electrical conductivity and transparency for these structures. We performed two-wire electrical measurements to quantify the structures resistance using metal contacts deposited on each end. The total sample area was 4 x 4mm{sup 2}. We measured a resistance of structures with 40nm gold sidewalls of 7.3{Omega}, which is lower than that of ITO glass (which has a sheet resistance around 10O/square). We investigated the structures optical properties based on both specular- and total-transmission measurements. Specular transmission is measured by collecting the transmitted light at normal incidence, while total transmission is obtained by collecting transmitted light at normal incidence and diffracted light using an integrating sphere. Figure 3 shows the total transmission of a grating with 40nm gold or silver sidewalls on a glass substrate compared to that of ITO. Additionally, the transparency changes very little within 30{sup o} off normal incidence. This high visible-light transmission of our metal-patterned structures is very promising for their application as transparent electrodes, because most visible light was allowed to propagate through the patterned metallic/polymeric structures. Researchers in our group continue to refine the fabrication methods and are investigating methods to make large-scale structures for use in a variety of applications that require both transparency and high electrical conductivity. We are also applying these fabrication techniques to build other structures that can manipulate light in novel ways.

14 SOLAR ENERGY↗

SU-F-J-57: Effectiveness of Daily CT-Based Three-Dimensional Image Guided and Adaptive Proton Therapy

Purpose: Daily CT-based three-dimensional image-guided and adaptive (CTIGRT-ART) proton therapy system was designed and developed. We also evaluated the effectiveness of the CTIGRT-ART. Methods: Retrospective analysis was performed in three lung cancer patients: Proton treatment planning was performed using CT image datasets acquired by Toshiba Aquilion ONE. Planning target volume and surrounding organs were contoured by a well-trained radiation oncologist. Dose distribution was optimized using 180-deg. and 270-deg. two fields in passive scattering proton therapy. Well commissioned Simplified Monte Carlo algorithm was used as dose calculation engine. Daily consecutive CT image datasets was acquired by an in-room CT (Toshiba Aquilion LB). In our in-house program, two image registrations for bone and tumor were performed to shift the isocenter using treatment CT image dataset. Subsequently, dose recalculation was performed after the shift of the isocenter. When the dose distribution after the tumor registration exhibits change of dosimetric parameter of CTV D90% compared to the initial plan, an additional process of was performed that the range shifter thickness was optimized. Dose distribution with CTV D90% for the bone registration, the tumor registration only and adaptive plan with the tumor registration was compared to the initial plan. Results: In the bone registration, tumor dose coverage was decreased by 16% on average (Maximum: 56%). The tumor registration shows better coverage than the bone registration, however the coverage was also decreased by 9% (Maximum: 22%) The adaptive plan shows similar dose coverage of the tumor (Average: 2%, Maximum: 7%). Conclusion: There is a high possibility that only image registration for bone and tumor may reduce tumor coverage. Thus, our proposed methodology of image guidance and adaptive planning using the range adaptation after tumor registration would be effective for proton therapy. This research is partially supported by Japan Agency for Medical Research and Development (AMED).

60 APPLIED LIFE SCIENCES↗

SU-F-T-230: A Simple Method to Assess Accuracy of Dynamic Wave Arc Irradiation Using An Electronic Portal Imaging Device and Log Files

Purpose: The Dynamic Wave Arc (DWA) technique, where the multi-leaf collimator (MLC) and gantry/ring move simultaneously in a predefined non-coplanar trajectory, has been developed on the Vero4DRT. The aim of this study is to develop a simple method for quality assurance of DWA delivery using an electronic portal imaging device (EPID) measurements and log files analysis. Methods: The Vero4DRT has an EPID on the beam axis, the resolution of which is 0.18 mm/pixel at the isocenter plane. EPID images were acquired automatically. To verify the detection accuracy of the MLC position by EPID images, the MLC position with intentional errors was assessed. Tests were designed considering three factors: (1) accuracy of the MLC position (2) dose output consistency with variable dose rate (160–400 MU/min), gantry speed (2.4–6°/s), ring speed (0.5–2.5°/s), and (3) MLC speed (1.6–4.2 cm/s). All the patterns were delivered to the EPID and compared with those obtained with a stationary radiation beam with a 0° gantry angle. The irradiation log, including the MLC position and gantry/ring angle, were recorded simultaneously. To perform independent checks of the machine accuracy, the MLC position and gantry/ring angle position were assessed using log files. Results: 0.1 mm intentional error can be detected by the EPID, which is smaller than the EPID pixel size. The dose outputs with different conditions of the dose rate and gantry/ring speed and MLC speed showed good agreement, with a root mean square (RMS) error of 0.76%. The RMS error between the detected and recorded data were 0.1 mm for the MLC position, 0.12° for the gantry angle, and 0.07° for the ring angle. Conclusion: The MLC position and dose outputs in variable conditions during DWA irradiation can be easily detected using EPID measurements and log file analysis. The proposed method is useful for routine verification. This research is (partially) supported by the Practical Research for Innovative Cancer Control (15Ack0106151h0001) from Japan Agency for Medical Research and development, AMED. Authors Takashi Mizowaki and Masahiro Hiraoka have consultancy agreement with Mitsubishi Heavy Industries, Ltd., Japan.

60 APPLIED LIFE SCIENCES↗

SU-F-T-267: A Clarkson-Based Independent Dose Verification for the Helical Tomotherapy

Purpose: There have been few reports for independent dose verification for Tomotherapy. We evaluated the accuracy and the effectiveness of an independent dose verification system for the Tomotherapy. Methods: Simple MU Analysis (SMU, Triangle Product, Ishikawa, Japan) was used as the independent verification system and the system implemented a Clarkson-based dose calculation algorithm using CT image dataset. For dose calculation in the SMU, the Tomotherapy machine-specific dosimetric parameters (TMR, Scp, OAR and MLC transmission factor) were registered as the machine beam data. Dose calculation was performed after Tomotherapy sinogram from DICOM-RT plan information was converted to the information for MU and MLC location at more segmented control points. The performance of the SMU was assessed by a point dose measurement in non-IMRT and IMRT plans (simple target and mock prostate plans). Subsequently, 30 patients’ treatment plans for prostate were compared. Results: From the comparison, dose differences between the SMU and the measurement were within 3% for all cases in non-IMRT plans. In the IMRT plan for the simple target, the differences (Average±1SD) were −0.70±1.10% (SMU vs. TPS), −0.40±0.10% (measurement vs. TPS) and −1.20±1.00% (measurement vs. SMU), respectively. For the mock prostate, the differences were −0.40±0.60% (SMU vs. TPS), −0.50±0.90% (measurement vs. TPS) and −0.90±0.60% (measurement vs. SMU), respectively. For patients’ plans, the difference was −0.50±2.10% (SMU vs. TPS). Conclusion: A Clarkson-based independent dose verification for the Tomotherapy can be clinically available as a secondary check with the similar tolerance level of AAPM Task group 114. This research is partially supported by Japan Agency for Medical Research and Development (AMED)

60 APPLIED LIFE SCIENCES↗

SU-F-T-268: A Feasibility Study of Independent Dose Verification for Vero4DRT

Purpose: Vero4DRT (Mitsubishi Heavy Industries Ltd.) has been released for a few years. The treatment planning system (TPS) of Vero4DRT is dedicated, so the measurement is the only method of dose verification. There have been no reports of independent dose verification using Clarksonbased algorithm for Vero4DRT. An independent dose verification software program of the general-purpose linac using a modified Clarkson-based algorithm was modified for Vero4DRT. In this study, we evaluated the accuracy of independent dose verification program and the feasibility of the secondary check for Vero4DRT. Methods: iPlan (Brainlab AG) was used as the TPS. PencilBeam Convolution was used for dose calculation algorithm of IMRT and X-ray Voxel Monte Carlo was used for the others. Simple MU Analysis (SMU, Triangle Products, Japan) was used as the independent dose verification software program in which CT-based dose calculation was performed using a modified Clarkson-based algorithm. In this study, 120 patients’ treatment plans were collected in our institute. The treatments were performed using the conventional irradiation for lung and prostate, SBRT for lung and Step and shoot IMRT for prostate. Comparison in dose between the TPS and the SMU was done and confidence limits (CLs, Mean ± 2SD %) were compared to those from the general-purpose linac. Results: As the results of the CLs, the conventional irradiation (lung, prostate), SBRT (lung) and IMRT (prostate) show 2.2 ± 3.5% (CL of the general-purpose linac: 2.4 ± 5.3%), 1.1 ± 1.7% (−0.3 ± 2.0%), 4.8 ± 3.7% (5.4 ± 5.3%) and −0.5 ± 2.5% (−0.1 ± 3.6%), respectively. The CLs for Vero4DRT show similar results to that for the general-purpose linac. Conclusion: The independent dose verification for the new linac is clinically available as a secondary check and we performed the check with the similar tolerance level of the general-purpose linac. This research is partially supported by Japan Agency for Medical Research and Development (AMED)

60 APPLIED LIFE SCIENCES↗

SU-F-T-288: Impact of Trajectory Log Files for Clarkson-Based Independent Dose Verification of IMRT and VMAT

Purpose: To investigate the effect of the trajectory files from linear accelerator for Clarkson-based independent dose verification in IMRT and VMAT plans. Methods: A CT-based independent dose verification software (Simple MU Analysis: SMU, Triangle Products, Japan) with a Clarksonbased algorithm was modified to calculate dose using the trajectory log files. Eclipse with the three techniques of step and shoot (SS), sliding window (SW) and Rapid Arc (RA) was used as treatment planning system (TPS). In this study, clinically approved IMRT and VMAT plans for prostate and head and neck (HN) at two institutions were retrospectively analyzed to assess the dose deviation between DICOM-RT plan (PL) and trajectory log file (TJ). An additional analysis was performed to evaluate MLC error detection capability of SMU when the trajectory log files was modified by adding systematic errors (0.2, 0.5, 1.0 mm) and random errors (5, 10, 30 mm) to actual MLC position. Results: The dose deviations for prostate and HN in the two sites were 0.0% and 0.0% in SS, 0.1±0.0%, 0.1±0.1% in SW and 0.6±0.5%, 0.7±0.9% in RA, respectively. The MLC error detection capability shows the plans for HN IMRT were the most sensitive and 0.2 mm of systematic error affected 0.7% dose deviation on average. Effect of the MLC random error did not affect dose error. Conclusion: The use of trajectory log files including actual information of MLC location, gantry angle, etc should be more effective for an independent verification. The tolerance level for the secondary check using the trajectory file may be similar to that of the verification using DICOM-RT plan file. From the view of the resolution of MLC positional error detection, the secondary check could detect the MLC position error corresponding to the treatment sites and techniques. This research is partially supported by Japan Agency for Medical Research and Development (AMED)

60 APPLIED LIFE SCIENCES↗

SU-F-T-494: A Multi-Institutional Study of Independent Dose Verification Using Golden Beam Data

Purpose: In general, beam data of individual linac is measured for independent dose verification software program and the verification is performed as a secondary check. In this study, independent dose verification using golden beam data was compared to that using individual linac’s beam data. Methods: Six institutions were participated and three different beam data were prepared. The one was individual measured data (Original Beam Data, OBD) .The others were generated by all measurements from same linac model (Model-GBD) and all linac models (All-GBD). The three different beam data were registered to the independent verification software program for each institute. Subsequently, patient’s plans in eight sites (brain, head and neck, lung, esophagus, breast, abdomen, pelvis and bone) were analyzed using the verification program to compare doses calculated using the three different beam data. Results: 1116 plans were collected from six institutes. Compared to using the OBD, the results shows the variation using the Model-GBD based calculation and the All-GBD was 0.0 ± 0.3% and 0.0 ± 0.6%, respectively. The maximum variations were 1.2% and 2.3%, respectively. The plans with the variation over 1% shows the reference points were located away from the central axis with/without physical wedge. Conclusion: The confidence limit (2SD) using the Model-GBD and the All-GBD was within 0.6% and 1.2%, respectively. Thus, the use of golden beam data may be feasible for independent verification. In addition to it, the verification using golden beam data provide quality assurance of planning from the view of audit. This research is partially supported by Japan Agency for Medical Research and Development(AMED)

60 APPLIED LIFE SCIENCES↗

SU-F-T-609: Impact of Dosimetric Variation for Prescription Dose Using Analytical Anisotropic Algorithm (AAA) in Lung SBRT

Purpose: Actual irradiated prescription dose to patients cannot be verified. Thus, independent dose verification and second treatment planning system are used as the secondary check. AAA dose calculation engine has contributed to lung SBRT. We conducted a multi-institutional study to assess variation of prescription dose for lung SBRT when using AAA in reference to using Acuros XB and Clarkson algorithm. Methods: Six institutes in Japan participated in this study. All SBRT treatments were planed using AAA in Eclipse and Adaptive Convolve (AC) in Pinnacle3. All of the institutes used a same independent dose verification software program (Simple MU Analysis: SMU, Triangle Product, Ishikawa, Japan), which implemented a Clarkson-based dose calculation algorithm using CT image dataset. A retrospective analysis for lung SBRT plans (73 patients) was performed to compute the confidence limit (CL, Average±2SD) in dose between the AAA and the SMU. In one of the institutes, a additional analysis was conducted to evaluate the variations between the AAA and the Acuros XB (AXB). Results: The CL for SMU shows larger systematic and random errors of 8.7±9.9 % for AAA than the errors of 5.7±4.2 % for AC. The variations of AAA correlated with the mean CT values in the voxels of PTV (a correlation coefficient : −0.7) . The comparison of AXB vs. AAA shows smaller systematic and random errors of −0.7±1.7%. The correlation between dose variations for AXB and the mean CT values in PTV was weak (0.4). However, there were several plans with more than 2% deviation of AAPM TG114 (Maximum: −3.3 %). Conclusion: In comparison for AC, prescription dose calculated by AAA may be more variable in lung SBRT patient. Even AXB comparison shows unexpected variation. Care should be taken for the use of AAA in lung SBRT. This research is partially supported by Japan Agency for Medical Research and Development (AMED)

60 APPLIED LIFE SCIENCES↗