Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ALIGNMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A Graphical Design Approach for Two-Input Single-Output Systems Exploiting Plant/Controller Alignment: Design and Application

Due to the unique structure of two-input single-output (TISO) feedback systems, several closed-loop properties can be characterized using the concepts of plant and controller “directions” and “alignment.” Poor plant/controller alignment indicates significant limitations in terms of closed-loop performance. In general, it is desirable to design a controller that is well aligned with the plant in order to minimize the size of the closed-loop sensitivity functions and closed-loop interactions. Although the concept of alignment can be a useful analysis tool for a given plant/controller pair, it is not obvious how a controller should be designed to achieve good alignment. We present a new controller design approach, based on the PQ method (Schroeck et al., 2001, “On Compensator Design for Linear Time invariant Dual-Input Single-Output Systems,” IEEE/ASME Trans. Mechatronics, 6(1), pp. 50–57), which explicitly incorporates knowledge of alignment into the design process. Here, this is accomplished by providing graphical information about the alignment angle on the Bode plot of the PQ frequency response. We show the utility of this approach through a design example.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Xavier: High-Performance X-Drop Adaptive Banded Pairwise Alignment (Xavier) v1.0

Pairwise sequence alignment is one of the most compute-intense challenges for the analysis of genomics data and it can account for more than 90% of the runtime depending on the application. Despite the effort to reduce the computational cost introducing heuristics such as banded and x-drop alignment, the performance of state-of-the-art software is often unsatisfactory for long sequences. Recent advances in single-molecule sequencing technologies keep increasing the length of the sequences to align at the cost of higher error rates b ranging from 5% to 15% b, emphasizing the need for fast and accurate software. Our long-read alignment software, named Xavier, computes high-performance x-drop adaptive banded pairwise alignment exploiting instruction-level parallelism via Single-Instruction-Multiple-Data (SIMD) operations. Xavier uses a narrow bandwidth that appreciably improves performance reducing the search space for the optimal alignment. In our experiment, the adaptive mechanism enables Xavier to find the optimal alignment between related sequences even when the error rate is as high as 50%. Xavier achieves speed-up up to 5X over competitor software when enabling the x-drop termination and up to 415X when disabling it, with negligible accuracy loss.

Guidi, Giulia↗

LOGAN: High-Performance X-Drop Pairwise Alignment on GPU (LOGAN) v1.0

Pairwise sequence alignment is one of the most computationally intensive kernels in genomic data analysis, accounting for more than 90% of the run time for key bioinformatics applications. This method is particularly expensive for third-generation sequences due to the high computational expense of analyzing these long read lengths (1Kb-1Mb). Given the quadratic overhead of exact pairwise algorithms such as Smith-Waterman, for long alignments, the community primarily relies on approximate algorithms that search only for high-quality alignments and stop early when one is not found. In this work, we present the first GPU optimization of the popular X-drop alignment algorithm, named LOGAN. Results show that our high-performance multi-GPU LOGAN implementation achieves up to 181.6 GCUPS and speed-ups up to 6.6x and 30.7x using 1 and 6 NVIDIA Tesla V100, respectively, over the state-of-the-art software running on two IBM Power9 processors using 168 threads, with equivalent accuracy. We also demonstrate a 2.3x LOGAN speed-up versus ksw2, a state-of-art vectorized algorithm for sequence alignment implemented in minimap2. To highlight the impact of our work on a real-world application, we couple the LOGAN aligner with a many-to-many long-read alignment software called BELLA, and demonstrate that our implementation improves the overall BELLA runtime by up to 10.6x. Finally, we adapt the Roofline model for our optimized kernel and demonstrate that our implementation is near-optimal on the NVIDIA Tesla V100s.

Guidi, Giulia↗

CHSalign: A Web Server That Builds upon Junction-Explorer and RNAJAG for Pairwise Alignment of RNA Secondary Structures with Coaxial Helical Stacking

RNA junctions are important structural elements of RNA molecules. They are formed when three or more helices come together in three-dimensional space. Recent studies have focused on the annotation and prediction of coaxial helical stacking (CHS) motifs within junctions. Here we exploit such predictions to develop an efficient alignment tool to handle RNA secondary structures with CHS motifs. Specifically, we build upon our Junction-Explorer software for predicting coaxial stacking and RNAJAG for modelling junction topologies as tree graphs to incorporate constrained tree matching and dynamic programming algorithms into a new method, called CHSalign, for aligning the secondary structures of RNA molecules containing CHS motifs. Thus, CHSalign is intended to be an efficient alignment tool for RNAs containing similar junctions. Experimental results based on thousands of alignments demonstrate that CHSalign can align two RNA secondary structures containing CHS motifs more accurately than other RNA secondary structure alignment tools. CHSalign yields a high score when aligning two RNA secondary structures with similar CHS motifs or helical arrangement patterns, and a low score otherwise. This new method has been implemented in a web server, and the program is also made freely available, at http://bioinformatics.njit.edu/CHSalign/.

59 BASIC BIOLOGICAL SCIENCES↗

Data-driven Alignment of the Tracker for the Mu2e Experiment

An alignment of the Mu2e Tracker is investigated using the Mu2e Offline Software and Millepede-II. Simulated misalignments of Tracker planes were inserted between Monte-Carlo event generation and before reconstruction using randomly generated $(x,y,z)$-translations and rotations of the rigid-body planes in the detector model. Cosmic ray muons, with no magnetic field present in the Detector Solenoid, will follow a straight-line trajectory. A maximum-likelihood fit is used to reconstruct a track and determine its parameters. Tracks traversing at least four planes, with ten registered straw hits, and a maximum time residual of $20$ ns are selected to be used in an alignment sample. The cuts were chosen to discard tracks with low information content, such as those with high levels of multiple scattering or those with low numbers of measurements contributing to a single track fit. Millepede-II produces the resulting alignment constants according to a simultaneous least-squares fit of the alignment parameters and the track parameters for all input tracks. The improved alignment constants are used to repeat the process and recover an increased number of suitable tracks, further improving the estimate of the alignment constants in subsequent iterations. A performance study of the process was conducted on a misaligned Tracker in the case of translation-only, and translation plus rotational misalignments. In both cases, the correct alignment constants were recovered to within statistical error after three global fit iterations. Additionally, a continuous integration system was developed for the \texttt{Mu2e/Offline} GitHub repository, introducing a convenient automated testing process for all proposed changes (``pull requests"). The tests developed included a full build of the software, followed by tests of the validation routines, geometry overlap checking, and multi-threading mode. Additionally, code quality checks and low-statistics physics comparison checks a re also available.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of Alignment on Polarized Infrared Emission from Polycyclic Aromatic Hydrocarbons

Polarized emission from polycyclic aromatic hydrocarbons (PAHs) potentially provides a new way to test the basic physics of the alignment of ultrasmall grains. In this paper, we present a new model of polarized PAH emission that takes into account the effect of PAH alignment with the magnetic field. We first generate a large sample of the grain angular momentum J by simulating the alignment of PAHs due to resonance paramagnetic relaxation that accounts for various interaction processes. We then calculate the polarization level of the PAH emission features for the different phases of the interstellar medium, including the cold neutral medium (CNM), reflection nebulae (RNe), and photodissociation regions. We find that a moderate degree of PAH alignment can significantly enhance the polarization degree of the PAH emission compared to the previous results obtained with randomly oriented angular momentum. In particular, we find that the smallest negatively charged PAHs in RNe can be excited to slightly suprathermal rotation due to enhanced ion collisional excitation, resulting in an increase of the polarization with the ionization fraction. Our results suggest that an RN is the most favorable environment in which to observe polarized PAH emission and to test the alignment physics of nanoparticles. Finally, we present an explicit relationship between the polarization level of PAH emission and the degree of external alignment for the CNM and RNe. The obtained relationship will be particularly useful for testing the alignment physics of PAHs in future observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Orbit Alignment in Triple Stars

The statistics of the angle Φ between orbital angular momenta in hierarchical triple systems with known inner visual or astrometric orbits are studied. A correlation between apparent revolution directions proves the partial orbit alignment known from earlier works. The alignment is strong in triples with outer projected separation less than ∼50 au, where the average Φ is about 20{sup ∘}. In contrast, outer orbits wider than 1000 au are not aligned with the inner orbits. It is established that the orbit alignment decreases with the increasing mass of the primary component. The average eccentricity of inner orbits in well-aligned triples is smaller than in randomly aligned ones. These findings highlight the role of dissipative interactions with gas in defining the orbital architecture of low-mass triple systems. On the other hand, chaotic dynamics apparently played a role in shaping more massive hierarchies. The analysis of projected configurations and triples with known inner and outer orbits indicates that the distribution of Φ is likely bimodal, where 80% of triples have Φ<70{sup ∘} and the remaining ones are randomly aligned.

79 ASTRONOMY AND ASTROPHYSICS↗

Galaxy Alignments with Surrounding Structure in the Sloan Digital Sky Survey

Using data from the Sloan Digital Sky Survey Legacy Survey, we study the alignment of luminous galaxies with spectroscopic data with the surrounding larger-scale structure as defined by galaxies with only photometric data. We find that galaxies from the red sequence have a statistically significant tendency for their apparent long axes to align parallel to the projected surrounding structure. Red galaxies more luminous than the median of our sample (M r < –21.78) have a mean alignment angle $\langle$Φ$\rangle$ < 45°, indicating preferred parallel alignment, at a significance level >4.5σ on projected scales 0.1 Mpc < r p ≤ 7.5 Mpc. Fainter red galaxies have $\langle$Φ$\rangle$ < 45° at a significance level >4.3σ at scales 1 Mpc < r p < 3 Mpc. At a projected scale r p = 3.0 Mpc, the mean alignment angle decreases steadily with increasing luminosity for red galaxies with M r ≲ –22.5, reaching $\langle$Φ$\rangle$ = 40$^{°}_{.}$49 ± 0$^{°}_{.}$56 for the most luminous 1% (M r ~ –23.57). Galaxies from the blue sequence show no statistically significant tendency for their axes to align with larger-scale structure, regardless of galaxy luminosity. Galaxies in higher-density regions do not show a statistically significant difference in the mean alignment angle from galaxies in lower-density regions; this holds true for the faint blue, luminous blue, faint red, and luminous red subsets.

79 ASTRONOMY AND ASTROPHYSICS↗

Alignment method for solar collector arrays

The present invention is directed to an improved method for establishing camera fixture location for aligning mirrors on a solar collector array (SCA) comprising multiple mirror modules. The method aligns the mirrors on a module by comparing the location of the receiver image in photographs with the predicted theoretical receiver image location. To accurately align an entire SCA, a common reference is used for all of the individual module images within the SCA. The improved method can use relative pixel location information in digital photographs along with alignment fixture inclinometer data to calculate relative locations of the fixture between modules. The absolute locations are determined by minimizing alignment asymmetry for the SCA. The method inherently aligns all of the mirrors in an SCA to the receiver, even with receiver position and module-to-module alignment errors.

14 SOLAR ENERGY↗

Mechanical design of multiple zone plates precision alignment apparatus for hard X-ray focusing in twenty-nanometer scale

An enhanced mechanical design of multiple zone plates precision alignment apparatus for hard x-ray focusing in a twenty-nanometer scale is provided. The precision alignment apparatus includes a zone plate alignment base frame; a plurality of zone plates; and a plurality of zone plate holders, each said zone plate holder for mounting and aligning a respective zone plate for hard x-ray focusing. At least one respective positioning stage drives and positions each respective zone plate holder. Each respective positioning stage is mounted on the zone plate alignment base frame. A respective linkage component connects each respective positioning stage and the respective zone plate holder. The zone plate alignment base frame, each zone plate holder and each linkage component is formed of a selected material for providing thermal expansion stability and positioning stability for the precision alignment apparatus.

36 MATERIALS SCIENCE↗

Alignment method for parabolic trough solar concentrators

A Theoretical Overlay Photographic (TOP) alignment method uses the overlay of a theoretical projected image of a perfectly aligned concentrator on a photographic image of the concentrator to align the mirror facets of a parabolic trough solar concentrator. The alignment method is practical and straightforward, and inherently aligns the mirror facets to the receiver. When integrated with clinometer measurements for which gravity and mechanical drag effects have been accounted for and which are made in a manner and location consistent with the alignment method, all of the mirrors on a common drive can be aligned and optimized for any concentrator orientation.

42 ENGINEERING↗

Scalable electric-field-assisted fabrication of vertically aligned carbon nanotube membranes with flow enhancement

In this work, we report a solution-based approach for fabricating vertically aligned carbon-nanotube (VACNT) membranes, which improves on the unaligned nature of CNT mixed-matrix membranes. This approach addresses important challenges regarding scalability and incorporation of different types and sizes of nanotube as pores in a membrane. In a new, solvent-deposition approach, CNTs are dispersed and then aligned and concentrated via electro-deposition from an organic solvent, using a composite AC + DC electric field to form aligned CNT arrays. This enables VACNT number densities that are two orders-of-magnitude higher than possible from direct suspension of CNTs in the liquid oligomer. The solvent is then replaced by a UV-curable oligomer, which is selectively cured to form macroscopic membranes of highly controlled thickness. After plasma etching to open pores, the VACNT membranes are shown to be permeable, and to have pore sizes consistent with flow through internal channels of the CNTs. In a first for field-aligned, solution-fabricated VACNT membranes, the pores show substantial, 100–300 × , gas-flow enhancement compared to theory, similar to membranes fabricated via less scalable methods (i.e., by CVD growth of already aligned CNT forests). The solution-based, electric-field-assisted approach aligns nanotubes of different sizes and types grown by any means, and is scalable to the efficient fabrication of large-area VACNT membranes for a variety of important applications.

36 MATERIALS SCIENCE↗

2011 Status of the Automatic Alignment System for the National Ignition Facility

Automated alignment for the National Ignition Facility (NIF) is accomplished using a large-scale parallel control system that directs 192 laser beams along the 300-m optical path. The beams are then focused down to a 50-micron spot in the middle of the target chamber. The entire process is completed in less than 50 minutes. The alignment system commands 9,000 stepping motors for highly accurate adjustment of mirrors and other optics. 41 control loops per beamline perform parallel processing services running on a LINUX cluster to analyze high-resolution images of the beams and their references. This paper describes the status the NIF automatic alignment system and the challenges encountered as NIF development has transitioned from building the laser, to becoming a research project supporting a 24 hour, 7 day laser facility. NIF is now a continuously operated system where performance monitoring is increasingly more critical for operation, maintenance, and commissioning tasks. Equipment wear and the effects of high energy neutrons from fusion experiments are issues which alter alignment efficiency and accuracy. New sensors needing automatic alignment assistance are common. System modifications to improve efficiency and accuracy are prevalent. Handling these evolving alignment and maintenance needs while minimizing the impact on NIF experiment schedule is expected to be an on-going challenge for the planned 30 year operational life of NIF.

42 ENGINEERING↗

Alignment of the CLAS12 central hybrid tracker with a Kalman Filter

Several factors can contribute to the difficulty of aligning the sensors of tracking detectors, including a large number of modules, multiple types of detector technologies, and non-linear strip patterns on the sensors. All three of these factors apply to the CLAS12 CVT, which is a hybrid detector consisting of planar silicon sensors with non-parallel strips, and cylindrical micromegas sensors with longitudinal and arc-shaped strips located within a 5 T superconducting solenoid. To align this detector, we used the Kalman Alignment Algorithm, which accounts for correlations between the alignment parameters without requiring the time-consuming inversion of large matrices. This is the first time that this algorithm has been adapted for use with hybrid technologies, non-parallel strips, and curved sensors. We present the results for the first alignment of the CLAS12 CVT using straight tracks from cosmic rays and from a target with the magnetic field turned off. After running this procedure, we achieved alignment at the level of 10 µm, and the widths of the residual spectra were greatly reduced. These results attest to the flexibility of this algorithm and its applicability to future use in the CLAS12 CVT and other hybrid or curved trackers, such as those proposed for the future Electron-Ion Collider.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental study of new laser-based alignment system at the KEK B-factory injector linear accelerator

A new laser-based alignment system for the precise alignment of accelerator components along an ideal straight line at the KEK B-factory injector linear accelerator (linac) is under development. This system is strongly required in the next generation of B-factories for the stable acceleration of high-brightness electron and positron beams with high bunch charges and also for maintaining the stability of injection beams with high quality. A new laser optics for the generation of a so-called Airy beam has been developed for the laser-based alignment system. The laser propagation characteristics both in vacuum and at atmospheric pressure have been systematically investigated in an 82-m-long straight section of the injector linac. The laser-based alignment measurements based on the new laser optics have been carried out with a measurement resolution of {+-}0.1 mm level by using an existing laser detection electronics. The horizontal and vertical displacements from a reference laser line measured using this system are in good agreement with those measured using a standard telescope-based optical alignment technique. In this report, we describe the experimental study in detail along with the basic designs and the recent developments in the new laser-based alignment system.

43 PARTICLE ACCELERATORS↗

THE SPIN ALIGNMENTS IN GALAXY PAIRS AS A TEST OF BOUNCING COUPLED DARK ENERGY

We investigate the effect of coupled dark energy (cDE) on the spin alignments in isolated pairs of galactic halos using the publicly available data from the hydrodynamic cDE simulations (H-CoDECs) that were run for various cDE models such as EXP001, EXP002, EXP003 (with exponential potential and constant coupling), EXP008e3 (with exponential potential and exponential coupling), and SUGRA003 (with supergravity potential and negative constant coupling), as well as for a standard {Lambda}CDM cosmology (with the WMAP7 parameters). Measuring the cosines of the angles between the spin axes in isolated pairs of galactic halos for each model and determining its probability density distribution, we show that for the SUGRA003 model with bouncing cDE the null hypothesis of no spin alignment in pairs of galactic halos is rejected at a 99.999% confidence level. In contrast, the {Lambda}CDM cosmology yields no significant signal of spin alignment, and the other four cDE models also exhibit only weak signals of spin alignments. The strength of the spin alignment signal is found to be almost independent of the total halo mass and separation distance in galaxy pairs. Showing also that no signal is detected from the Sloan Digital Sky Survey DR 7, we conclude that the spin alignments in galaxy pairs are in principle a unique test of bouncing cDE models.

79 ASTRONOMY AND ASTROPHYSICS↗

ANALYSIS OF SPIN-ORBIT ALIGNMENT IN THE WASP-32, WASP-38, AND HAT-P-27/WASP-40 SYSTEMS

We present measurements of the spin-orbit alignment angle, {lambda}, for the hot Jupiter systems WASP-32, WASP-38, and HAT-P-27/WASP-40, based on data obtained using the HARPS spectrograph. We analyze the Rossiter-McLaughlin effect for all three systems and also carry out Doppler tomography for WASP-32 and WASP-38. We find that WASP-32 (T {sub eff} = 6140{sup +90} {sub -100} K) is aligned, with an alignment angle of {lambda} = 10.{sup 0}5{sup +6.4} {sub -6.5} obtained through tomography, and that WASP-38 (T {sub eff} = 6180{sup +40} {sub -60} K) is also aligned, with tomographic analysis yielding {lambda} = 7.{sup 0}5{sup +4.7} {sub -6.1}. The latter result provides an order-of-magnitude improvement in the uncertainty in {lambda} compared to the previous analysis of Simpson et al. We are only able to loosely constrain the angle for HAT-P-27/WASP-40 (T{sub eff} = 5190{sup +160} {sub -170} K) to {lambda} = 24.{sup 0}2{sup +76.0}{sub -44.5}, owing to the poor signal-to-noise ratio of our data. We consider this result a non-detection under a slightly updated version of the alignment test of Brown et al. We place our results in the context of the full sample of spin-orbit alignment measurements, finding that they provide further support for previously established trends.

79 ASTRONOMY AND ASTROPHYSICS↗

Spin-orbit alignment for 110 day period KOI368.01 from gravity darkening

We fit the Kepler photometric light curve of the KOI-368 system using an oblate, gravity-darkened stellar model in order to constrain its spin-orbit alignment. We find that the system is relatively well-aligned with a sky-projected spin-orbit alignment of λ = 10° ± 2°, a stellar obliquity of ψ = 3° ± 7°, and a true spin-orbit alignment of ψ = 11° ± 3°. Although our measurement differs significantly from zero, the low value for ψ is consistent with spin-orbit alignment. We also measure various transit parameters of the KOI-368 system: R {sub KOI-368} = 2.28 ± 0.02 R {sub ☉}, R{sub p} = 1.83 ± 0.02 R {sub jup}, and i = 89.°221 ± 0.°013. This work shows that our gravity-darkened model can constrain long-period, well-aligned planets and M-class stars orbiting fast-rotators, allowing for measurement of a new subcategory of transiting bodies.

79 ASTRONOMY AND ASTROPHYSICS↗