Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “3D Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

3D And 4D Cloud Lifecycle Investigations Using Innovative Scanning Radar Analysis Methods. Final report

With the vast upgrades to the ARM program radar measurement capabilities in 2010 and beyond, our ability to probe the 3D structure of clouds and associated precipitation has increased dramatically. This project build on the PI's and co-I's expertisein the analysis of radar observations. The first research thrust aims to document the 3D morphological (as depicted by the radar reflectivity structure) and 3D dynamical (cloud$-$scale eddies) structure of boundary layer clouds. Unraveling the 3D dynamical structure of stratocumulus and shallow cumulus clouds requires decomposition of the environmental wind contribution and particle sedimentation velocity from the observed radial Doppler velocity. The second thrust proposes to unravel the mechanism of cumulus entrainment (location, scales) and its impact on microphysics utilizing radar measurements from the vertically pointing and new scanning radars at the ARM sites. The third research thrust requires the development of a cloud$-$tracking algorithm that monitors the properties of cloud.

3D structure↗

SU-F-T-513: Dosimetric Validation of Spatially Fractionated Radiotherapy Using Gel Dosimetry

Purpose: Spatially fractionated radiation therapy, also known as GRID therapy, is used to treat large solid tumors by irradiating the target to a single dose of 10–20Gy through spatially distributed beamlets. We have investigated the use of a 3D gel for dosimetric characterization of GRID therapy. Methods: GRID therapy is an external beam analog of volumetric brachytherapy, whereby we produce a distribution of hot and cold dose columns inside the tumor volume. Such distribution can be produced with a block or by using a checker-like pattern with MLC. We have studied both types of GRID delivery. A cube shaped acrylic phantom was filled with polymer gel and served as a 3D dosimeter. The phantom was scanned and the CT images were used to produce two plans in Pinnacle, one with the grid block and one with the MLC defined grid. A 6MV beam was used for the plan with a prescription of 1500cGy at dmax. The irradiated phantom was scanned in a 3T MRI scanner. Results: 3D dose maps were derived from the MR scans of the gel dosimeter and were found to be in good agreement with the predicted dose distribution from the RTP system. Gamma analysis showed a passing rate of 93% for 5% dose and 2mm DTA scoring criteria. Both relative and absolute dose profiles are in good agreement, except in the peripheral beamlets where the gel measured slightly higher dose, possibly because of the changing head scatter conditions that the RTP is not fully accounting for. Our results have also been benchmarked against ionization chamber measurements. Conclusion: We have investigated the use of a polymer gel for the 3D dosimetric characterization and evaluation of GRID therapy. Our results demonstrated that the planning system can predict fairly accurately the dose distribution for GRID type therapy.

60 APPLIED LIFE SCIENCES↗

3D camera assisted fully automated calibration of scanning laser Doppler vibrometers

Scanning laser Doppler vibrometers (LDV) are used to measure full-field vibration shapes of products and structures. In most commercially available scanning laser Doppler vibrometer systems the user manually draws a grid of measurement locations on a 2D camera image of the product. The determination of the correct physical measurement locations can be a time consuming and diffcult task. In this paper we present a new methodology for product testing and quality control that integrates 3D imaging techniques with vibration measurements. This procedure allows to test prototypes in a shorter period because physical measurements locations will be located automatically. The proposed methodology uses a 3D time-of-flight camera to measure the location and orientation of the test-object. The 3D image of the time-of-flight camera is then matched with the 3D-CAD model of the object in which measurement locations are pre-defined. A time of flight camera operates strictly in the near infrared spectrum. To improve the signal to noise ratio in the time-of-flight measurement, a time-of-flight camera uses a band filter. As a result of this filter, the laser spot of most laser vibrometers is invisible in the time-of-flight image. Therefore a 2D RGB-camera is used to find the laser-spot of the vibrometer. The laser spot is matched to the 3D image obtained by the time-of-flight camera. Next an automatic calibration procedure is used to aim the laser at the (pre)defined locations. Another benefit from this methodology is that it incorporates automatic mapping between a CAD model and the vibration measurements. This mapping can be used to visualize measurements directly on a 3D CAD model. Secondly the orientation of the CAD model is known with respect to the laser beam. This information can be used to find the direction of the measured vibration relatively to the surface of the object. With this direction, the vibration measurements can be compared more precisely with numerical experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Formation of conductive copper lines by femtosecond laser irradiation of copper nitride film on plastic substrates

In this paper, we report a simple method to form conductive copper lines by scanning a single-beam femtosecond pulse laser on a plastic substrate covered with copper nitride (Cu{sub 3}N) film. The Cu{sub 3}N films were prepared by DC magnetron sputtering in the presence of an Ar + N{sub 2} atmosphere at 100 °C. The influence of the laser power and scanning speed on the formed copper line width, surface features, and morphology was analyzed by means of optical microscopy, X-ray diffraction, non-contact 3D profilometer, and scanning electron microscopy. The experimental results demonstrate that low laser power and low scanning speed favor the formation of uniform and flat Cu lines. After process optimization, copper lines with a width less than 5 μm were obtained, which provides an attractive application prospect in the field of flexible electronic devices.

36 MATERIALS SCIENCE↗

Surface characterization of carbon fiber polymer composites and aluminum alloys after laser interference structuring

Here, the increasing use of Carbon Fiber-reinforced Polymer matrix Composites (CFPC) and aluminum alloys as lightweight materials in the automotive and aerospace industries demands enhanced surface preparation and control of surface morphology prior to joining. In this study, surfaces of both composite and aluminum were prepared for joining using an Nd:YAG laser in a two-beam interference setup, enabling the (a) structuring of the AL 5182 surface, (b) removal of the resin layer on top of carbon fibers, and (c) structuring of the carbon fibers. CFPC specimens of T700S carbon fiber, Prepreg - T8 3 epoxy, 5 ply thick, 0/90o plaques were used. The effect of laser fluence, scanning speed, and number of shots-per-spot was investigated on the removal rate of the resin without an excessive damage of the fibers. Optical micrographs, 3D imaging, and scanning electron microscope (SEM) imaging were used to study the effect of the laser processing on surface morphology.

36 MATERIALS SCIENCE↗

Highly Reversible Plating/Stripping of Porous Zinc Anodes for Multivalent Zinc Batteries

Zinc continues to garner immense interest due to its versatility as an anode material in several configurations utilizing either alkaline or mild-pH electrolytes. Current research on using mild-pH electrolytes has improved the rechargeability aspect of Zn-based batteries since Zn2+ is solely utilized for plating/stripping of Zn. Several studies have incorporated Zn metal foils, yet, dramatic improvements can be achieved by expressing Zn as a porous structure. Herein, we use a quasi-pulsed electrodeposition process to prepare a conformal Zn coating onto 3D porous copper foam. By tuning the electrodeposition parameters, we achieved an optimal Zn coating that undergoes reversible plating/stripping when tested in symmetric Zn cells, which supported a low overpotential of ~60 mV for up to 100 cycles. We further investigated changes in the surface morphology by studying the Zn surface of both foil and 3D structure using scanning electron microscopy and X-ray micro-computed tomography. Both techniques showed that the Zn foil undergoes dramatic alterations at the surface, which results in inhomogeneous deposition of Zn, whereas the 3D form exhibited minimal changes. Lastly, we paired both Zn foil and 3D Zn with vanadium oxide and demonstrated that the porous structure supports high rate capability and high specific capacity.

25 ENERGY STORAGE↗

Suppressing proximity effects during rapid serial two-photon lithography through tuning of reaction–diffusion kinetics

The ability of two-photon lithography (TPL) to print deterministic nanoporous 3D structures is highly valuable for many applications. However, it is challenging to print such structures rapidly due to the proximity effects that cause closely spaced features to enlarge and merge. A key challenge is the limited understanding of the origins and spatiotemporal dynamics of the long-range proximity effects that extend beyond the optical focal spot. Here, we empirically investigate these proximity effects in serial TPL using custom-made acrylate-based photoresists. We demonstrate that the complex spatiotemporal dynamics of the proximity effects can be explained through the kinetics of the reaction–diffusion photopolymerization mechanisms that underlie the curing process. Specifically, we show that the proximity effects arise due to comparable timescales of reaction and diffusion of oxygen. Furthermore, we demonstrate that long-range proximity effects can be suppressed by introducing phenolic inhibitors, which reduce oxygen consumption through non-inhibiting side reactions and promote faster termination of curing reactions. These insights enabled improving the linewidths from >400 to 260 nm during printing of nanoporous 3D woodpiles at scanning speeds of 50 mm s −1 . Thus, the knowledge generated here can be applied to deterministically tune the proximity effects and enable rapid printing of high-resolution nanoporous 3D structures.

36 MATERIALS SCIENCE↗

Development of Weigh-out Process and Evaluations for Underwater Partial Gravity Simulations

For the upcoming Artemis lunar missions, astronauts will need to train in a spacesuit where partial gravity can be simulated such as the NASA Neutral Buoyancy Lab (NBL). At the NBL, dive weights and foam can be added around the spacesuit to attain a satisfactory center of buoyancy (CB) and center of gravity (CG) location to simulate the lunar gravity (1/6thG) effects. If CG and CB are not co-located properly, incorrect righting moments can be introduced, and both simulation quality and EVA task performance can be impaired. Based on the findings from the initial testing using xEMU spacesuits, it was observed that the weigh-out method (i.e., determination of the weights and foam quantities and position) needed further development to improve the simulation quality, especially for the subjects who experienced excessive instability. This paper aims to present the on-going effort to improve the weigh-out process for enabling NBL lunar EVA simulations. For this effort, a human-suit model was created to use suit CAD and 3D human body scans to estimate both CB and CG location for each suited subject. NBL weigh-out testing was performed to characterize the effects of CG and CB positioning, in which the 3D human-suit model was used to determine optimal weigh-out combinations of weights and foam. Postural, balance, and subjective feedback were gathered for each weigh-out configuration. The results indicated that, as the CB was shifted higher and the CB and CG located closer to each other, the subject tended to be more stable and their EVA performance improved. A high CB location was then prioritized across 4 additional subjects in both small and large size spacesuits. When compared to the initial xEMU test series, improved performance was observed across all subjects as the CB moved higher and aligned closer to the system CG.

Pouyan Sabahi↗

Development of Weigh-out Process and Evaluations for Underwater Partial Gravity Simulations

For the upcoming Artemis lunar missions, astronauts will need to train in a spacesuit where partial gravity can be simulated such as the NASA Neutral Buoyancy Lab (NBL). At the NBL, dive weights and foam can be added around the spacesuit to attain a satisfactory center of buoyancy (CB) and center of gravity (CG) location to simulate the lunar gravity (1/6thG) effects. If CG and CB are not co-located properly, incorrect righting moments can be introduced, and both simulation quality and EVA task performance can be impaired. Based on the findings from the initial testing using xEMU spacesuits, it was observed that the weigh-out method (i.e., determination of the weights and foam quantities and position) needed further development to improve the simulation quality, especially for the subjects who experienced excessive instability. This paper aims to present the on-going effort to improve the weigh-out process for enabling NBL lunar EVA simulations. For this effort, a human-suit model was created to use suit CAD and 3D human body scans to estimate both CB and CG location for each suited subject. NBL weigh-out testing was performed to characterize the effects of CG and CB positioning, in which the 3D human-suit model was used to determine optimal weigh-out combinations of weights and foam. Postural, balance, and subjective feedback were gathered for each weigh-out configuration. The results indicated that, as the CB was shifted higher and the CB and CG located closer to each other, the subject tended to be more stable and their EVA performance improved. A high CB location was then prioritized across 4 additional subjects in both small and large size spacesuits. When compared to the initial xEMU test series, improved performance was observed across all subjects as the CB moved higher and aligned closer to the system CG.

Pouyan Sabahi↗

Development of Weigh-Out Process and Evaluations for Underwater Partial Gravity Simulations

For the upcoming Artemis lunar missions, astronauts will need to train in a spacesuit where partial gravity can be simulated such as the NASA Neutral Buoyancy Lab (NBL). At the NBL, dive weights and foam can be added around the spacesuit to attain a satisfactory center of buoyancy (CB) and center of gravity (CG) location to simulate the lunar gravity (1/6thG) effects. If CG and CB are not co-located properly, incorrect righting moments can be introduced, and both simulation quality and EVA task performance can be impaired. Based on the findings from the initial testing using xEMU spacesuits, it was observed that the weigh-out method (i.e., determination of the weights and foam quantities and position) needed further development to improve the simulation quality, especially for the subjects who experienced excessive instability. This paper aims to present the on-going effort to improve the weigh-out process for enabling NBL lunar EVA simulations. For this effort, a human-suit model was created to use suit CAD and 3D human body scans to estimate both CB and CG location for each suited subject. NBL weigh-out testing was performed to characterize the effects of CG and CB positioning, in which the 3D human-suit model was used to determine optimal weigh-out combinations of weights and foam. Postural, balance, and subjective feedback were gathered for each weigh-out configuration. The results indicated that, as the CB was shifted higher and the CB and CG located closer to each other, the subject tended to be more stable and their EVA performance improved. A high CB location was then prioritized across 4 additional subjects in both small and large size spacesuits. When compared to the initial xEMU test series, improved performance was observed across all subjects as the CB moved higher and aligned closer to the system CG.

Pouyan Sabahi↗

Pool boiling critical heat flux studies of accident tolerant fuel cladding materials

Pool boiling experiments have been performed at atmospheric pressure on potential accident tolerant fuel (ATF) cladding materials (Zirlo®, Cr coated Zirlo®, FeCrAl coated Zirlo®, and monolithic SiC) to evaluate the Critical Heat Flux (CHF) points. Corrosion resistant coatings of Cr and FeCrAl alloy were deposited on flat Zirlo® samples using cold spray technology. The as-prepared samples after uniform surface polishing were subjected to autoclave tests at 360 °C water and 18.6 MPa for 360 h to simulate prototypic corrosion of the ATF cladding materials in LWR normal operation. Surface characteristics potentially influencing CHF such as surface morphology, roughness, static contact angle, and surface chemistry were characterized using a suite of characterization methods including scanning electron microscopy, 3D optical profilometry, optical contact angle measurements, and x-ray photoelectron spectroscopy (XPS). Thermo-physical properties of the samples such as density, thermal conductivity, and heat capacity were measured by differential scanning calorimetry and laser flash thermal diffusivity measurement. FeCrAl coatings showed CHF values comparable to bare Zirlo® samples, while slightly lower CHF values were observed for Cr coated samples and bulk SiC flats (produced by chemical vapor deposition, CVD). As-deposited Cr coatings showed 67% higher CHF than the as-polished Cr coatings due to its higher surface roughness level. The autoclave testing for the prepared samples generally increased the CHF except for the surface polished Cr coatings. Similar CHF values of bare Zirlo®, FeCrAl coating, and CVD SiC samples were observed after autoclave test but there were negligible change CHF of Cr coatings. XPS studies indicated that the formation or deposition of a few monolayers of hydrophobic carbonaceous species on surface can affect CHF values. The trends in CHF data are discussed in terms of evolution of the surface characteristics of the ATF materials.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Revitalizing the Space Shuttle's Thermal Protection System with Reverse Engineering and 3D Vision Technology

The Space Shuttle is protected by a Thermal Protection System (TPS) made of tens of thousands of individually shaped heat protection tile. With every flight, tiles are damaged on take-off and return to earth. After each mission, the heat tiles must be fixed or replaced depending on the level of damage. As part of the return to flight mission, the TPS requirements are more stringent, leading to a significant increase in heat tile replacements. The replacement operation requires scanning tile cavities, and in some cases the actual tiles. The 3D scan data is used to reverse engineer each tile into a precise CAD model, which in turn, is exported to a CAM system for the manufacture of the heat protection tile. Scanning is performed while other activities are going on in the shuttle processing facility. Many technicians work simultaneously on the space shuttle structure, which results in structural movements and vibrations. This paper will cover a portable, ultra-fast data acquisition approach used to scan surfaces in this unstable environment.

Wilson, Brad↗

Revitalizing the Space Shuttle's Thermal Protection System with Reverse Engineering and 3D Vision Technology

The Space Shuttle is protected by a Thermal Protection System (TPS) made of tens of thousands of individually shaped heat protection tile. With every flight, tiles are damaged on take-off and return to earth. After each mission, the heat tiles must be fixed or replaced depending on the level of damage. As part of the return to flight mission, the TPS requirements are more stringent, leading to a significant increase in heat tile replacements. The replacement operation requires scanning tile cavities, and in some cases the actual tiles. The 3D scan data is used to reverse engineer each tile into a precise CAD model, which in turn, is exported to a CAM system for the manufacture of the heat protection tile. Scanning is performed while other activities are going on in the shuttle processing facility. Many technicians work simultaneously on the space shuttle structure, which results in structural movements and vibrations. This paper will cover a portable, ultra-fast data acquisition approach used to scan surfaces in this unstable environment.

Wilson, Brad↗

Micropillar compression technique applied to micron-scale mudstone elasto-plastic deformation.

Mudstone mechanical testing is often limited by poor core recovery and sample size, preservation and preparation issues, which can lead to sampling bias, damage, and time-dependent effects. A micropillar compression technique, originally developed by Uchic et al. 2004, here is applied to elasto-plastic deformation of small volumes of mudstone, in the range of cubic microns. This study examines behavior of the Gothic shale, the basal unit of the Ismay zone of the Pennsylvanian Paradox Formation and potential shale gas play in southeastern Utah, USA. Precision manufacture of micropillars 5 microns in diameter and 10 microns in length are prepared using an ion-milling method. Characterization of samples is carried out using: dual focused ion - scanning electron beam imaging of nano-scaled pores and distribution of matrix clay and quartz, as well as pore-filling organics; laser scanning confocal (LSCM) 3D imaging of natural fractures; and gas permeability, among other techniques. Compression testing of micropillars under load control is performed using two different nanoindenter techniques. Deformation of 0.5 cm in diameter by 1 cm in length cores is carried out and visualized by a microscope loading stage and laser scanning confocal microscopy. Axisymmetric multistage compression testing and multi-stress path testing is carried out using 2.54 cm plugs. Discussion of results addresses size of representative elementary volumes applicable to continuum-scale mudstone deformation, anisotropy, and size-scale plasticity effects. Other issues include fabrication-induced damage, alignment, and influence of substrate.

03 NATURAL GAS↗

SU-E-T-424: Feasibility of 3D Printed Radiological Equivalent Customizable Tissue Like Materials

Purpose: To investigate the feasibility of 3D printing CT# specific radiological equivalent tissue like materials. Methods: A desktop 3D printer was utilized to create a series of 3 cm x 3 cm x 2 cm PLA plastic blocks of varying fill densities. The fill pattern was selected to be hexagonal (Figure 1). A series of blocks was filled with paraffin and compared to a series filled with air. The blocks were evaluated with a “GE Lightspeed” 16 slice CT scanner and average CT# of the centers of the materials was determined. The attenuation properties of the subsequent blocks were also evaluated through their isocentric irradiation via “TrueBeam” accelerator under six beam energies. Blocks were placed upon plastic-water slabs of 4 cm in thickness assuring electronic equilibrium and data was collected via Sun Nuclear “Edge” diode detector. Relative changes in dose were compared with those predicted by Varian “Eclipse” TPS. Results: The CT# of 3D printed blocks was found to be a controllable variable. The fill material was able to narrow the range of variability in each sample. The attenuation of the block tracked with the density of the total fill structure. Assigned CT values in the TPS were seen to fall within an expected range predicted by the CT scans of the 3D printed blocks. Conclusion: We have demonstrated that it is possible to 3D print materials of varying tissue equivalencies, and that these materials have radiological properties that are customizable and predictable.

60 APPLIED LIFE SCIENCES↗

The effect of amorphous selenium detector thickness on dual-energy digital breast imaging

Purpose: Contrast enhanced (CE) imaging techniques for both planar digital mammography (DM) and three-dimensional (3D) digital breast tomosynthesis (DBT) applications requires x-ray photon energies higher than the k-edge of iodine (33.2 keV). As a result, x-ray tube potentials much higher (>40 kVp) than those typical for screening mammography must be utilized. Amorphous selenium (a-Se) based direct conversion flat-panel imagers (FPI) have been widely used in DM and DBT imaging systems. The a-Se layer is typically 200 μm thick with quantum detective efficiency (QDE) >87% for x-ray energies below 26 keV. However, QDE decreases substantially above this energy. To improve the object detectability of either CE-DM or CE-DBT, it may be advantageous to increase the thickness (d{sub Se}) of the a-Se layer. Increasing the d{sub Se} will improve the detective quantum efficiency (DQE) at the higher energies used in CE imaging. However, because most DBT systems are designed with partially isocentric geometries, where the gantry moves about a stationary detector, the oblique entry of x-rays will introduce additional blur to the system. The present investigation quantifies the effect of a-Se thickness on imaging performance for both CE-DM and CE-DBT, discussing the effects of improving photon absorption and blurring from oblique entry of x-rays. Methods: In this paper, a cascaded linear system model (CLSM) was used to investigate the effect of d{sub Se} on the imaging performance (i.e., MTF, NPS, and DQE) of FPI in CE-DM and CE-DBT. The results from the model are used to calculate the ideal observer signal-to-noise ratio, d′, which is used as a figure-of-merit to determine the total effect of increasing d{sub Se} for CE-DM and CE-DBT. Results: The results of the CLSM show that increasing d{sub Se} causes a substantial increase in QDE at the high energies used in CE-DM. However, at the oblique projection angles used in DBT, the increased length of penetration through a-Se introduces additional image blur. The reduced MTF and DQE at high spatial frequencies lead to reduced two-dimensional d′. These losses in projection image resolution may subsequently result in a decrease in the 3D d′, but the degree of which is largely dependent on the DBT reconstruction algorithm. For a filtered backprojection (FBP) algorithm with spectral apodization and slice-thickness filters, which dominate the blur for reconstructed images at oblique angles, the effect of oblique entry of x-rays on 3D d′ is minimal. Thus, increasing d{sub Se} results in an improvement in d′ for both CE-DM and CE-DBT with typical FBP reconstruction parameters. Conclusions: Increased d{sub Se} improves CE breast imaging performance by increasing QDE of detectors at higher energies, e.g., 49 kVp. Although there is additional blur in the oblique angled projections of a DBT scan, the overall 3D d′ for DBT is not degraded because the dominant source blur at these angles results from the reconstruction filters of the employed FBP algorithm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Topographic Quintet: Comparing Five Methods for Measuring Ultra-High Resolution Topography

We compare different methods for collecting ultra-high resolution topography data within an analog planetary, human landing site scale area. Our aim is to investigate the cost and benefits of different 3D terrain mapping techniques, their associated data collection methods, and how their different specifications (e.g., range, spatial resolution, scanning-time, mobility, operating constraints, GPS-Denied operation, etc.) might be applied to landing-site characterization and mission operations. We compare 3D terrain data collected during a field campaign in November 2021 from an outcrop at Kilbourne Hole in southern New Mexico using different Light Detection and Ranging (LiDAR) sensors on the ground and stereo-derived 3D data from framing cameras mounted on small uncrewed aerial systems (sUAS).Our foci for this experiment are ground-based, surveying, and autonomous vehicle-type 3D scanning sensors that might be used for planetary surface exploration from landed assets (e.g., lander, rover, astronaut-mounted sensors, decent imaging, hoppers, or drones).[e.g. 1]This test is not meant to benchmark these scanners against one another, nor provide a recommendation for a specific make or model. Rather, our goal is to quantify time, effort, resolution, and operational trade-offs that are important for selecting a topographic instrument/methodology for a given scope of terrain characterization. Our results indicate that each technique is capable of exceptional quality terrain characterization for planetary exploration and scientific inquiry, but we hypothesize the appropriate technique is highly dependent on the scope of operational specifications and science requirements.

P Whelley↗

SU-F-BRD-11: A Virtual Simulator Designed for Collision Prevention in Proton Therapy

Purpose: In proton therapy, collisions between patient and nozzle potentially occur in attaining minimal air gap due to the large nozzle structure. Thus, we developed software predicting the collisions of the nozzle and patient by simulating treatments. Methods: 3D modeling of a gantry inner-floor, nozzle and robotic-couch was done by using the SolidWorks based on the manufacturer’s machine data. To obtain patient body information, a 3D-scanner was utilized to scan a patient right before CT scanning. From the acquired images, a 3D-image of the patient’s body contour was reconstructed. The accuracy of the image was confirmed against the CT image for a humanoid phantom. The machine components and the virtual patient were combined on the treatment-room coordinate system, resulting in a virtual simulator. The simulator simulated the motion of its components such as rotation and translation of gantry, nozzle and couch, in real scale. Collision, if any, was examined both in static mode and dynamic mode. The static mode checks only at fixed positions of the machine’s components while dynamic mode examines while one component is in motion. Collision was notified if any voxel of two components, for example a nozzle and a patient or couch, overlapped when calculating volume locations. The event and collision point are visualized and colliding volumes are reported. Results: All components were successfully assembled and the motions could be accurately controlled. The 3D-shape of a phantom agreed with CT images within a deviation of 2 mm. Collision situations can be simulated within minutes and the results are displayed and reported. Conclusion: The developed software will be useful in improving patient safety and clinical efficiency for proton therapy. This work was supported by the National Research Foundation of Korea funded by Ministry of Science, ICT & Future Planning (2012M3A9B6055201, 2013M2A2A7043507), and Samsung Medical Center grant (GFO1130081)

60 APPLIED LIFE SCIENCES↗