Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “0000”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

STEADY COUNTERFLOW HE II HEAT TRANSFER THROUGH POROUS MEDIA

We present steady state counterflow measurements performed on porous samples saturated in He II. The experiment is composed of a vacuum insulated open channel whose top extremity is closed to a Minco registered heater. The temperature and pressure differences across the plug are measured by two germanium TTR-G Microsensors registered thermometers and a Validyne DP10-20 differential pressure sensor. Applied heat fluxes range up to 0.5 kW/m{sup 2} of sample cross section. Measurements were performed at temperatures ranging from 1.7 to 2.1 K on highly anisotropic samples provided by Composite Technology Development Inc.: circular pellets (3.08 mm thick and 28.58 mm in diameter) of 20 compressed layers of pre-impregnated woven magnet insulation. In the laminar regime, the permeability is estimated from the pressure drop measurements for comparison with room temperature data. In the turbulent regime, the model based on tortuosity developed previously fails to describe the heat transfer behavior of He II in this type of porous medium.

42 ENGINEERING↗

DEVELOPMENT OF A 4 K STIRLING-TYPE PULSE TUBE CRYOCOOLER FOR A MOBILE TERAHERTZ DETECTION SYSTEM

We discuss in this paper the design and development of a 4 K Stirling-type pulse tube cryocooler for a mobile terahertz detection system. This system integrates new heterodyne detector technology at terahertz frequencies with advancements of Stirling-type pulse tube technology that brings the advent of cooled detector sensitivities in a mobile, compact, and long duration operation system without degradation of sensitivity. To achieve this goal we reduced overall system size, input power, and temperature fluctuations and mechanical vibrations in order to maintain the detector sensitivity. The Stirling-type pulse tube cryocooler developed for this system is a hybrid design employing a He-4 pulse-tube cryocooler operating at 60 Hz and 2.5 MPa average pressure that precools a He-3 pulse tube cryocooler operating at 30 Hz and 1.0 MPa average pressure to achieve 4 K cooling for the terahertz receiver. The He-4 cryocooler employs stainless steel mesh regenerators for the first stage and ErPr spheres for the second stage, while the He-3 cryocooler employs stainless mesh for the first stage and ErPr spheres for the second stage with a layered rare-earth third stage regenerator. Design details and cooler performance goals are discussed.

42 ENGINEERING↗

JEFFERSON LAB 12 GEV CEBAF UPGRADE

The existing continuous electron beam accelerator facility (CEBAF) at Thomas Jefferson National Accelerator Facility (TJNAF) is a 5-pass, recirculating cw electron Linac operating at approx6 GeV and is devoted to basic research in nuclear physics. The 12 GeV CEBAF Upgrade is a $310 M project, sponsored by the Department of Energy (DOE) Office of Nuclear Physics, that will expand its research capabilities substantially by doubling the maximum energy and adding major new experimental apparatus. The project received construction approval in September 2008 and has started the major procurement process. The cryogenic aspects of the 12 GeV CEBAF Upgrade includes: doubling the accelerating voltages of the Linacs by adding ten new high-performance, superconducting radiofrequency (SRF) cryomodules (CMs) to the existing 42 1/4 cryomodules; doubling of the 2 K cryogenics plant; and the addition of eight superconducting magnets.

43 PARTICLE ACCELERATORS↗

COOL-IT: A HEAT EXCHANGER SYSTEM TO PROVIDE GASEOUS HELIUM AT INTERMEDIATE TEMPERATURES FOR SRF LINAC

ALICE, a prototype accelerator developed at the Daresbury laboratory UK, has successfully demonstrated the energy-recovery technique by circulating the electron beam to more than 20 MeV. At the heart of ALICE is a superconducting linac operating at 2 K. At high average-current operation the performance of Superconducting RF (SRF) cavities suffer from instabilities due to the generation of higher-order modes (HOM) as well as microphonics. HOMs are extracted out of the cavities using HOM absorbers operating at 80 K. This, however, increases the demand for cooling power at intermediate temperatures, i.e. at 80 K and 5 K, by more than an order of magnitude.In order to provide this extra cooling capacity with gaseous helium a new cryogenic system, 'COOL-IT,'(System for cooling to intermediate temperatures) is being developed. It will provide two streams of helium gases at 80 K and 5 K. COOL-IT uses a set of heat exchangers cooled by liquid helium and liquid nitrogen to generate two cold streams. It will be integrated into the existing cryo-system for ALICE for automatic operation. This paper describes the COOL-IT system in detail.

42 ENGINEERING↗

THE ADIABATIC DEMAGNETIZATION REFRIGERATOR FOR THE MICRO-X SOUNDING ROCKET TELESCOPE

The Micro-X Imaging X-ray Spectrometer is a sounding rocket payload slated for launch in 2011. An array of Transition Edge Sensors, which is operated at a bath temperature of 50 mK, will be used to obtain a high resolution spectrum of the Puppis-A supernova remnant. An Adiabatic Demagnetization Refrigerator (ADR) with a 75 gram Ferric Ammonium Alum (FAA) salt pill in the bore of a 4 T superconducting magnet provides a stable heat sink for the detector array only a few seconds after burnout of the rocket motors. This requires a cold stage design with very short thermal time constants. A suspension made from Kevlar strings holds the 255 gram cold stage in place. It is capable of withstanding loads in excess of 200 g. Stable operation of the TES array in proximity to the ADR magnet is ensured by a three-stage magnetic shielding system which consists of a superconducting can, a high-permeability shield and a bucking coil. The development and testing of the Micro-X payload is well underway.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE CRYOPLANT FOR THE ITER NEUTRAL BEAM TEST FACILITY TO BE BUILT AT RFX IN PADOVA, ITALY

The Neutral Beam Test Facility (NBTF), planned to be constructed in Padua (Italy), will constitute the prototype of the two Neutral Beam Injectors (NBI), which will be installed in the ITER plant (Cadarache-France). The NBTF is composed of a 1 MV accelerator that can produce a 40 A deuteron pulsed neutral beam particles. The necessary vacuum needed in the accelerator is achieved by two large cryopumps, designed by FZK-Karlsruhe, with radiation shields cooled between 65 K and 90 K and with cryopanels cooled by 4 bar supercritical helium (ScHe) between 4.5 K and 6.5 K. A new cryoplant facility will be installed with two large helium refrigerators: a Shield Refrigerator (SR), whose cooling capacity is up to 30 kW between 65 K and 90 K, and a helium Main Refrigerator (MR), whose equivalent cooling capacity is up to 800 W at 4.5 K. The cooling of the cryopanels is obtained with two (ScHe) 30 g/s pumps (one redundant), working in a closed cycle around 4 bar producing a pressure head of 100 mbar. Two heat exchangers are immersed in a buffer dewar connected to the MR. The MR and SR different operation modes are described in the paper, as well as the new cryoplant installation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Room temperature infrared photoresponse of self assembled Ge/Si (001) quantum dots grown by molecular beam epitaxy

We report on the observation of intraband near infrared (approx3.1 mum) and mid infrared (approx6.2 mum) photocurrent response at room temperature using Ge/Si self-assembled quantum dots grown by molecular beam epitaxy. Due to the bimodal size distribution and SiGe intermixing, distinguishable photoluminescence transitions are observed at 10 K, below and above the optical band gap of bulk Ge. The observed redshift in photocurrent with increasing temperature has been explained by the excitonic electric field originated due to infrared excitation at low temperatures. A good correlation between the spectral photocurrent response and photoluminescence of the quantum dots has been established.

36 MATERIALS SCIENCE↗

The ESRF Miniature Pulsed Magnetic Field System

We have developed a portable system to provide pulsed magnetic fields on the ESRF X-ray beamlines. The complete system consists of a power supply, liquid Helium and liquid Nitrogen dewars with a siphon each, control electronics and a double cryostat for separate coil and sample cooling. The liquid nitrogen cooled solenoids reach a maximum field of 30 Tesla for a total pulse duration of one milisecond. They are constructed for optimised cooling rate after the pulse to obtain a high duty cycle, the repetition rate is five pulses per minute at maximum field. The sample is cooled in an independent Helium flow cryostat which is inserted into the bore of the magnet. The flow cryostat has a temperature range from 5 to 250 Kelvin with a direct contact between the sample and Helium flow. This overview gives a general presentation of the system and we will show recent results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Progress on the superconducting undulator for ANKA and on the instrumentation for R and D

Superconducting undulators show a larger magnetic field strength for the same gap and period length, as compared to permanent magnet devices, which allows to generate X-ray beams of higher brilliance and with harder spectrum. The worldwide first short period length superconducting undulator is in operation since 2005 at the synchrotron light source ANKA in Karlsruhe [1]. To further drive the development in this field a research and development program is being carried out. In this contribution we report on the last progress of the construction of a 1.5 m long superconducting undulator with a period length of 15 mm, planned to be installed in ANKA beginning 2010 to be the light source of the new beamline NANO for high resolution X-ray scattering. The key specifications of the system are an undulator parameter K higher than 2 (with a magnetic gap of 5 mm) and a phase error smaller than 3.5 degrees. Cryocoolers will keep the coils at 4.2 K for a beam heat load of 4 W. The ongoing R and D includes improvements in understanding of the magnetic field properties and of the beam heat load mechanisms. The tools and instruments under development to fulfill these tasks are also discussed.

43 PARTICLE ACCELERATORS↗

Continuous Flow Cryostat for X-Ray Fluorescence

A continuous Helium flow cryostat was designed and built by Cryovac GMbH to specifications given by ESRF beamline ID26. The beamline has constructed a high energy resolution X-ray emission spectrometer using multiple spherically bent analyser crystals, together with the sample and detector on a vertical Rowland circle. The double shrouded cryostat has a low profile designed to fit into the spectrometer setup, the lowest detector position allows for a Bragg angle of 85 degrees with a 1 meter diameter Rowland circle. The cryostat has a temperature range of 5 to 300 Kelvin on the sample holder which is cooled by static Helium exchange gas. The cryostat has triple windows for beam entrance, transmission and fluorescence; the latter offers an opening angle of 80 degrees horizontally and 50 degrees vertically. The cryostat can be configured to work in two different operation modes: translation or rotation. The translation mode offers a displacement of 50 mm to accommodate multiple samples on the sample holder. The rotation mode is used for polarisation studies on single crystals.We show recent results obtained on Chromium containing molecular complexes; data collection was done at a temperature of 10 Kelvin to avoid radiation damage.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Moessbauer Study and Macroscopic/Global Magnetic Behavior of Powdered Ilmenite (FeTiO{sub 3}) Sample

In this article, the commercial synthetic powdered sample of ilmenite (FeTiO{sub 3}) has been re-examined by Moessbauer spectroscopy in the paramagnetic regime from 77 K to 280 K and in a magnetically ordered state below 57 K. The effective vibrating mass and the Debye temperature was found to be (78{+-}3) amu and (359{+-}27) K, respectively. The two sextet components were used for correct fitting of the Moessbauer spectra recorded at 5 K and 45 K in an external magnetic field of 5 T. Moreover, the macroscopic magnetic measurements were carried out by an MPMS XL-7 magnetometer to determine a temperature dependence of the molar susceptibility and hysteresis loops of this sample. The Moessbauer spectra and magnetization measurements confirm that below the ordering temperature of ilmenite, it behaves as a non-ideal antiferromagnetic material with a significant magnetic hardening at low temperatures. In addition, the magnetic molar susceptibility follows a Curie-Weiss law with C{sub m=5.8x10{sup -5}Km{sup 3}/mol}, and Weiss temperature {theta}{sub p} = 30.6 K.

36 MATERIALS SCIENCE↗

Investigations of Iron Minerals Formed by Dissimilatory Alkaliphilic Bacterium with {sup 57}Fe Moessbauer Spectroscopy

Anaerobic alkaliphilic bacterium of Geoalkalibacter ferrihydriticus type (strain Z-0531), isolated from a bottom sediment sample from the weakly mineralized soda Lake Khadyn, have been analyzed. The strain uses the amorphous Fe(III)-hydroxide (AFH) as an electron acceptor and acetate CH{sub 3}COO{sup -} as an electron donor. Moessbauer investigations of solid phase samples obtained during the process of the bacterium growth were carried out at room temperature, 77.8 K, 4.2 K without and with the presence of an external magnetic field (6 T) applied perpendicular to the {gamma}-bebam.

36 MATERIALS SCIENCE↗

Spectral Collection of Polyethylene Pellets at nearly Cryogenic Temperature to Improve Selectivity of Raman Measurement

Raman spectroscopy has been extensively used for analysis of diverse polymer samples. Normally, Raman spectral collection of samples is routinely performed at room temperature for convenience. However, the feasibility of improving spectral selectivity and the resulting quantitative accuracy, when samples are measured at nearly cryogenic temperature, has not been investigated. For this purpose, we attempted to measure the density of polyethylene (PE) pellets at cryogenic temperatures and the resulting accuracies were compared with that from room temperature measurement. Initially, each of 25 PE sample was allowed to cool down to cryogenic temperature and the corresponding Raman spectra were continuously collected while the temperature of sample increased. When the temperature of sample was at cryogenic temperature, the resulting band widths were narrower compared to those at room temperature, thereby improving the accuracy of density measurement. In overall, the proposed Raman scheme is simple and efficient; therefore, it could be further applied for analysis of other polymers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microwave induced zero-conductance state in a Corbino geometry two-dimensional electron gas with capacitive contacts

Microwave induced photoconductivity of a two-dimensional electron gas in selectively doped GaAs/AlAs heterostructures has been studied using the Corbino geometry with capacitive contacts at a temperature T=1.6 K and magnetic field B up to 0.5 T. Zero-conductance states have been observed in the samples under study subject to microwave radiation, similarly to the samples with Ohmic contacts. It has been shown that Ohmic contacts do not play a significant role for observation of zero-conductance states induced by microwave radiation.

36 MATERIALS SCIENCE↗

ADMX Phase II : Relocation and Millikelvin Cooling

Low mass axions are an attractive candidate for making up dark matter. While there are several models for how the Axion couples with other matter, were they to be the majority of the local galactic dark matter halo, they would have a number density on the order of 10{sup 14} cm{sup -3}. The Axion Dark Matter eXperiment (ADMX) is a microwave cavity experiment searching for axion Dark Matter via the axion's electromagnetic coupling. While the original ADMX did not see evidence of axions, the experiment is planned to go through two phases of upgrades to expand its sensitivity and provide a definitive search for axion dark matter. The first phase established the use of a SQUID amplifier which can reduce the amplifier noise temperature to the 100 mK range. In the second phase we will first move the experiment from LLNL to CENPA at the University of Washington. Once the experiment has been moved successfully we will install a dilution refrigerator to cool the cavity to the 100 mK range thus increasing the sensititivity to the level required to scan the remainder of the allowed model space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method for cooling nanostructures to microkelvin temperatures

We propose a new scheme aimed at cooling nanostructures to microkelvin temperature based on the well established technique of adiabatic nuclear demagnetization: we attach each device measurement lead to an individual nuclear refrigerator, allowing efficient thermal contact to a microkelvin bath. On a prototype consisting of a parallel network of nuclear refrigerators, temperatures of {approx}1 mK simultaneously on ten measurement leads have been reached upon demagnetization, thus completing the first steps toward ultracold nanostructures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On-chip superconductivity via gallium overdoping of silicon

We report on superconducting properties of gallium-enriched silicon layers in commercial (100) oriented silicon wafers. Ion implantation and subsequent rapid thermal annealing have been applied for realizing gallium precipitation beneath a silicon-dioxide cover layer. Depending on the preparation parameters, we observe a sharp drop to zero resistance at 7 K. The critical-field anisotropy proofs the thin-film character of superconductivity. In addition, out-of-plane critical fields of above 9 T and critical current densities exceeding 2 kA/cm{sup 2} promote these structures to be possible playgrounds for future microelectronic technology.

36 MATERIALS SCIENCE↗

A high sensitivity ultralow temperature RF conductance and noise measurement setup

We report on the realization of a high sensitivity RF noise measurement scheme to study small current fluctuations of mesoscopic systems at milli-Kelvin temperatures. The setup relies on the combination of an interferometric amplification scheme and a quarter-wave impedance transformer, allowing the measurement of noise power spectral densities with gigahertz bandwidth up to five orders of magnitude below the amplifier noise floor. We simultaneously measure the high frequency conductance of the sample by derivating a portion of the signal to a microwave homodyne detection. We describe the principle of the setup, as well as its implementation and calibration. Finally, we show that our setup allows to fully characterize a subnanosecond on-demand single electron source. More generally, its sensitivity and bandwidth make it suitable for applications manipulating single charges at GHz frequencies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗