Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage support”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Additively Manufactured Plastic Plasma Spectrometer

We report results in development and testing of a low resource top hat electrostatic analyzer (ESA) for space plasma measurements. This device has been additively manufactured (3D-printed) using fused deposition modeling. The classic top hat design is composed of four plastic pieces, without any surface coatings. The three conducting electrodes are printed from carbon nanotube infused polyether ether ketone (CNT-PEEK). The fourth piece, an insulating electrode support, uses pure PEEK. This ESA is designed to detect electrons in space from 10eV up to 30 keV. We demonstrate that the printed CNT-PEEK is sufficiently electrically conductive to support the fast high voltage slewing often required for high time resolution measurements. The plastic ESA has been successfully vibrated beyond standard pre-flight levels, tested under keV electron beam illumination over a wide range of temperatures, and tested under UV illumination, simulating the solar Ly-α flux. In comparison with an identical machined aluminum ESA, our CNT-PEEK ESA provides nominal energy/angle band passes, closely matching simulation. These band passes imply minimal impact from surface charging at beam energies of 2-3 keV, although more investigation is needed. We also find that the CNT-PEEK ESA provides far superior out-of-band electron rejection and UV photon rejection compared to the machined aluminum ESA. We do not detect any problems with trapped gases or outgassing. This development offers potential for significant mass savings, implementation of otherwise unattainable geometric configurations, and dramatic simplification in manufacturing and assembly processes required for development of space plasma instruments.

Quetzal Larrick↗

Enhancing Synchronous Condenser Operation of Hydrogenerators

Hydropower plants are sometimes dispatched below capacity or even shut down to meet water regulations. These can temporarily be repurposed to operate as synchronous condensers. To enable this capability, this paper proposes a design that allows hydrogenerators to safely operate as synchronous condensers, providing fast voltage and reactive power support under both normal and boost conditions. The proposed design integrates capability curves with hydrogenerators’ excitation systems through modifications using proposed MVA-field current curve, current controller, and limiter. The design is implemented locally at the machine for rapid response. Simulation results demonstrate the effectiveness of the proposed design and using hydrogenerators as synchronous condensers in power grids.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

A Framework to Quantify the Economic Benefit from Local VAR Compensation

Abstract It is generally accepted that reactive power (or Var) compensation will bring benefits for utilities and industrial customers by providing local voltage and power factor support. However, there is a lack of a systematic approach to quantitatively identify the economic benefit. In addition, with the deregulation and restructuring, it is important to indicate the amount of benefit that each market participant may potentially receive given the right price signals. If such information can be easily obtained and presented, it will be more convenient for decision-markers to determine the cost benefit sharing of installing a Var compensator. This vision of this paper is to lay out a possible method for quantitatively evaluating the benefits from local reactive power compensation. The approach is to quantify the benefits into several categories such as reduced losses, shifting reactive power flow to real power flow, and increased transfer. The calculation of these benefits are illustrated with a simple two-bus power system model and then presented with a more complicated model using Optimal Power Flow to calculate the benefits. Simulation on the more complex system is conducted with seven buses in two areas. The simulation results show that the possible economic benefits can be significant, if compared with capacity payments to central generators or payment of power factor penalties applied by utilities. The potential economic value of local Var compensation may give various parties in electricity supply, delivery and end-use consumption a better understanding of the Var benefits to assist their cost-benefit analysis for Var compensation installation. Sensitivity analysis is also provided to illustrate that the benefits may not be monotonically increasing. Also, this paper suggests that the future reactive power market should consider local Var providers or other way to encourage load Var capability, since local Var benefit is significant.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Framework to Quantify the Economic Impact from Local VAR Compensation

It is generally accepted that reactive power (or Var) compensation will bring benefits for utilities and industrial customers by providing local voltage and power factor support. However, there is a lack of a systematic approach to quantitatively identify the economic benefit. In addition, with deregulation and restructuring, it is important to indicate the amount of benefit that each market participant may potentially receive given the right price signals. If such information can be easily obtained and presented, it will be more convenient for decision-markers to determine the cost benefit sharing of installing a Var compensator. The vision of this paper is to lay out a possible method for quantitatively evaluating the benefits from local reactive power compensation. The approach is to quantify the benefits into several categories such as reduced losses, shifting reactive power flow to real power flow, and increased transfer. The calculation of these benefits are illustrated with a simple two-bus power system model and then presented with a more complicated model using Optimal Power Flow to calculate the benefits. Simulation on the more complex system is conducted with seven buses in two areas. The simulation results show that the possible economic benefits can be significant, if compared with capacity payments to central generators or payment of power factor penalties applied by utilities. The potential economic value of local Var compensation may give various parties in electricity supply, delivery and end-use consumption a better understanding of the Var benefits to assist their cost-benefit analysis for Var compensation installation. Sensitivity analysis is also provided to illustrate that the benefits may not be monotonically increasing. Also, this paper suggests that the future reactive power market should consider local Var providers or other way to encourage load Var capability, since local Var benefit is significant.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Supervised classification of electric power transmission line nominal voltage from high-resolution aerial imagery

For many researchers, government agencies, and emergency responders, access to the geospatial data of US electric power infrastructure is invaluable for analysis, planning, and disaster recovery. Historically, however, access to high quality geospatial energy data has been limited to few agencies because of commercial licenses restrictions, and those resources which are widely accessible have been of poor quality, particularly with respect to reliability. Recent efforts to develop a highly reliable and publicly accessible alternative to the existing datasets were met with numerous challenges – not the least of which was filling the gaps in power transmission line voltage ratings. To address the line voltage rating problem, we developed and tested a basic methodology that fuses knowledge and techniques from power systems, geography, and machine learning domains. Specifically, we identified predictors of nominal voltage that could be extracted from aerial imagery and developed a tree-based classifier to classify nominal line voltage ratings. Overall, we found that line support height, support span, and conductor spacing are the best predictors of voltage ratings, and that the classifier built with these predictors had a reliable predictive accuracy (that is, within one voltage class for four out of the five classes sampled). In conclusion, we applied our approach to a study area in Minnesota.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High temperature characteristics of nitric oxide annealed p-channel 4H-SiC metal oxide semiconductor field effect transistors

In this work, p-channel 4H-SiC MOSFETs were fabricated and analyzed at high temperature. It is demonstrated that nitridation of the gate oxide enables enhancement mode operation in these devices. Nitrogen incorporation at the 4H-SiC/SiO2 interface by nitric oxide annealing reduces the interface trap density energetically located in the lower half of the 4H-SiC bandgap, resulting in viable high temperature p-channel devices. In the 27–300 °C temperature range, the threshold voltage decreases with increasing temperature, consistent with the reduction of occupied interface traps at higher temperatures. The hole channel mobility is weakly temperature dependent under strong inversion conditions. Hall measurements support that above the threshold voltage, the mobility is limited by surface roughness scattering. In weaker inversion, the channel conductivity is limited by interface hole trapping and Coulomb scattering. In addition, high temperature bias stress measurements confirm a temperature activated hole trapping under negative gate bias, which requires further investigations.

Das, Suman (ORCID:0000000317146287)↗

Shield to Pin Coupling of Lightning-Like Transients on Payload Umbilical Cables on a Launch Pad

In this paper we describe in-situ testing of a long payload umbilical, on a launch site, injected with “lightning- like” transients and describe resulting pin-to-pin voltages. Injections and voltage measurements near the ground support equipment room, as well as at a location near the payload junction box, are made. The umbilical cables tested include an outer over-braid and the inner conductor coupling is examined for open circuit, short-circuit and various loads representative of spacecraft input impedances. This testing is important because the Kennedy Space Center (KSC) where the lightning occurrence is the highest in the United States, is the primary launch site for Launch Services Program spacecraft customers. Lightning planning is essential but developing a lightning plan is often overlooked or not adequately analyzed leaving the spacecraft vulnerable to time delays or even damage when lightning occurs. At other popular launch sites like Vandenberg Air Force Base (VAFB) where lightning occurs less often, although at the same or greater intensity when it does occur, lightning planning is often completely ignored by the spacecraft. The two major questions to be addressed in the lightning plan are what retesting should be done to establish a “goodness” level and what is the trigger criteria for this testing? The spacecraft will typically use a standard spacecraft check-out procedure to address the necessary retesting, but determining the trigger criteria is often an issue. For instance, a spacecraft needs to understand what their immunity is to a certain lightning magnitude and location. Determining the amount of current that can be coupled onto a spacecraft umbilical can be calculated by using worst case assumptions or measured with current probes and current measurement devices. Spacecraft can also determine what pin-to-pin voltages they are sensitive to, however pin-to-pin voltage measurements are not typically taken during the strike due to the invasive nature of this measurement. In this paper, we present detailed data on the shield to pin voltage transfer functions to provide insight to the spacecraft developers for lightning retest criteria planning. The results from this unique testing opportunity provide essential details on specific coupling mechanisms affecting spacecraft hardware that interfaces with the ground support equipment. This missing link between cable shield currents and payload susceptibility voltages has been methodically tested and representative data presented.

Trout, Dawn↗

Voltage-Dependent Barrier Height of Electron Transport through Iron Porphyrin Molecular Junctions

Electron transport through iron porphyrin (FeP) molecules self-assembled on a gold (Au) substrate was investigated using conductive atomic force microscopy (AFM) to measure current–voltage (I–V) characteristics. In the direct tunneling region (|V| ≤ 0.1 V), the Simmons model was used to characterize the electron transport. Furthermore, the energy barrier between the Fermi energy level of Au and the highest occupied molecular orbital (HOMO) level of the FeP molecule was determined to be between 0.3 and 0.6 eV; the range of the electron attenuation coefficient was 0.6–0.8 Å–1. Instead of a constant barrier height, a voltage-dependent barrier height was adapted to simulate the experimental I–V curves over the entire voltage range (|V| ≤ 2 V) using the Simmons model for the intermediate case. The voltage-dependent barrier height is supported by a previously predicted response of molecular-projected self-consistent Hamiltonian orbitals. The dependence showed that the HOMO level relative to the Fermi energy level of the Au electrode decreased as the bias voltage increased. To verify the deposition of the FeP on the Au substrate, Raman spectroscopy and AFM analysis were performed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Power Hardware-in-the-Loop Testing of Distribution Solid State Transformers

Savannah River National Laboratory and Resilient Power Systems have developed a utility grade solid state transformer and are planning on deploying it for testing in January 2018. The solid state transformer is the next generation solution to implementation of distributed energy resources such as solar and batteries. They can directly connect the solar and battery systems to DC ports and rout power between these DC ports and load ports. The solid state transformer can revolutionize current grid modernization initiatives by supplying grid support and building support services at the edge of the grid. These services consist of volt-VAR optimization, power factor correction, voltage regulation, frequency regulation, fault current support, demand side management, DC bus for AC/DC capable houses, and power routing between multiple ports for transactive control. For this fiscal year a test plan for testing the SST capabilities was develop. Along with the FPGA controls for the SST output ports. These controls will allow for any waveform to be produced by each port of the SST. Finally, a hybrid distribution SST was tested at the eGRID resulting in medium voltage testing experience for SRNL engineering team. DOE is currently engaged, through the Building Technology Office and Infrastructure Security and Energy Restoration in future work building from this project.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Speed Isolation Board for Flight Hardware Testing

There is a need to provide a portable and cost-effective galvanic isolation between ground support equipment and flight hardware such that any unforeseen voltage differential between ground and power supplies is eliminated. An interface board was designed for use between the ground support equipment and the flight hardware that electrically isolates all input and output signals and faithfully reproduces them on each side of the interface. It utilizes highly integrated multi-channel isolating devices to minimize size and reduce assembly time. This single-board solution provides appropriate connector hardware and breakout of required flight signals to individual connectors as needed for various ground support equipment. The board utilizes multi-channel integrated circuits that contain transformer coupling, thereby allowing input and output signals to be isolated from one another while still providing high-fidelity reproduction of the signal up to 90 MHz. The board also takes in a single-voltage power supply input from the ground support equipment and in turn provides a transformer-derived isolated voltage supply to power the portion of the circuitry that is electrically connected to the flight hardware. Prior designs used expensive opto-isolated couplers that were required for each signal to isolate and were time-consuming to assemble. In addition, these earlier designs were bulky and required a 2U rack-mount enclosure. The new design is smaller than a piece of 8.5 ~11-in. (.22 ~28-mm) paper and can be easily hand-carried where needed. The flight hardware in question is based on a lineage of existing software-defined radios (SDRs) that utilize a common interface connector with many similar input-output signals present. There are currently four to five variations of this SDR, and more upcoming versions are planned based on the more recent design.

Yamamoto, Clifford K.↗

Power system effects and mitigation recommendations for DER cyberattacks

Extensive deployment of interoperable distributed energy resources (DER) is increasing the power system cyber security attack surface. National and jurisdictional interconnection standards require DER to include a range of autonomous and commanded grid‐support functions, which can drastically influence power quality, voltage, and bulk system frequency. Here, the authors investigate the impact to the cyber‐physical power system in scenarios where communications and operations of DER are controlled by an adversary. The findings show that each grid‐support function exposes the power system to distinct types and magnitudes of risk. The physical impact from cyber actions was analysed in cases of DER providing distribution system voltage regulation and transmission system support. Finally, recommendations are presented for minimising the risk using engineered parameter limits and segmenting the control network to minimise common‐mode vulnerabilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Voltage stability smart meter for analyzing voltage data and controlling an electrical power source and/or an electric appliance

Systems and methods for voltage stability monitoring and active/reactive power support are disclosed herein. In some embodiments, a smart electric meter of an end user in a grid power system can measure the voltage supplied to the end user via the grid power system, and can analyze the voltage data to detect critical voltage characteristics. The critical voltage characteristics may indicate that a voltage collapse event is likely. The smart electric meter can further estimate a voltage stability margin based on the voltage data. If necessary, the smart electric meter can control an electrical power source and/or an electric appliance positioned at or near the end user to increase the voltage stability margin.

Min, Liang↗

Characterization of self-magnetic pinch (SMP) radiographic diode performance on RITS-6 at Sandia National Laboratories. I. Diode dynamics, DC heating to extend radiation pulse

Radiographic diodes focus on an intense electron beam to a small spot size to minimize the source area of energetic photons for radiographic interrogation. The self-magnetic pinch (SMP) diode has been developed as such a source and operated as a load for the six-cavity radiographic integrated test stand (RITS-6) inductive voltage adder driver. While experiments support the generally accepted conclusion that a 1:1 aspect diode (cathode diameter equals anode–cathode gap) delivers optimum SMP performance, such experiments also show that reducing the cathode diameter, while reducing spot size, also results in reduced radiation dose, by as much as 50%, and degraded shot reproducibility. Analysis of the effective electron impingement angle on the anode converter with time made possible by a newly developed dose-rate array diagnostic indicates that fast-developing oscillations of the angle are correlated with early termination of the radiation pulse on many of the smaller-diameter SMP shots. This behavior as a function of relative cathode size persists through experiments with output voltages and currents up to 11.5 MV and 225 kA, respectively, and with spot sizes below approximately few millimeters. Since simulations to date have not predicted such oscillatory behavior, considerable discussion of the angle behavior of SMP shots is made to lend credence to the inference. We report there is clear anecdotal evidence that DC heating of the SMP diode region leads to stabilization of this oscillatory behavior. This is the first of two papers on the performance of the SMP diode on the RITS-6 accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Voltage cycling as a dynamic operation mode for high temperature electrolysis solid oxide cells

Solid Oxide Electrolysis Cells (SOECs) have emerged as a promising technology for the efficient production of H2 via high-temperature electrolysis. However, power input from dynamic energy sources remains a significant challenge for their long-term stability. It is important to analyze the tolerance of cells under dynamic operation conditions. This study focuses on evaluating the impact of voltage cycling on the performance and durability of electrode-supported SOECs. We explore the operational limits and degradation mechanisms of SOECs subjected to various voltage conditions and find that the cells have high tolerance for dynamic voltage. Voltage cycling between 1.3 V and 1.5 V for 9000 cycles does not damage the cell. Conversely, cycling to higher voltages (≥1.7 V) results in accelerated degradation. Advanced characterization is used to screen for various degradation modes post operation. Within the oxygen electrode, XRD and STEM EDS find compositional and phase evolution in all voltage cycled samples including increased decomposition of the air electrode resulting in cation migration. Microstructural analysis of the fuel electrode from nano-CT data shows minimal change throughout the sample set and no evidence of Ni migration, indicating the fuel electrode is stable and not impacted by cycling to higher voltages within the timeframe studied.

Zhu, Zhikuan↗

High-Voltage Clock Driver for Photon-Counting CCD Characterization

A document discusses the CCD97 from e2v technologies as it is being evaluated at Goddard Space Flight Center's Detector Characterization Laboratory (DCL) for possible use in ultra-low background noise space astronomy applications, such as Terrestrial Planet Finder Coronagraph (TPF-C). The CCD97 includes a photoncounting mode where the equivalent output noise is less than one electron. Use of this mode requires a clock signal at a voltage level greater than the level achievable by the existing CCD (charge-coupled-device) electronics. A high-voltage waveform generator has been developed in code 660/601 to support the CCD97 evaluation. The unit generates required clock waveforms at voltage levels from -20 to +50 V. It deals with standard and arbitrary waveforms and supports pixel rates from 50 to 500 kHz. The system is designed to interface with existing Leach CCD electronics.

Baker, Robert↗

Determination of defect density of state distribution of amorphous silicon solar cells by temperature derivative capacitance-frequency measurement

In this contribution, we demonstrate the application temperature dependent capacitance-frequency measurements (C-f) to n-i-p hydrogenated amorphous silicon (a-Si:H) solar cells that are forward-biased. By using a forward bias, the C-f measurement can detect the density of defect states in a particular energy range of the interface region. For this contribution, we have carried out this measurement method on n-i-p a-Si:H solar cells of which the intrinsic layer has been exposed to a H{sub 2}-plasma before p-type layer deposition. After this treatment, the open-circuit voltage and fill factor increased significantly, as well as the blue response of the solar cells as is concluded from external quantum efficiency. For single junction, n-i-p a-Si:H solar cells initial efficiency increased from 6.34% to 8.41%. This performance enhancement is believed to be mainly due to a reduction of the defect density in the i-p interface region after the H{sub 2}-plasma treatment. These results are confirmed by the C-f measurements. After H{sub 2}-plasma treatment, the defect density in the intrinsic layer near the i-p interface region is lower and peaks at an energy level deeper in the band gap. These C-f measurements therefore enable us to monitor changes in the defect density in the interface region as a result of a hydrogen plasma. The lower defect density at the i-p interface as detected by the C-f measurements is supported by dark current-voltage measurements, which indicate a lower carrier recombination rate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sensor enabled data-driven predictive analytics for modeling and control with high penetration of DERs in distribution systems

The electric power grid is undergoing a tremendous transformation due to the increasing penetration of renewable energy resources beginning with wind and more recently with the distributed energy resources (DERs) such as solar and battery storage. DERs have dramatically changed the role of the distribution systems in the overall power grid, and they are expected to contribute a significant portion of power generation in the future. If current trends for DERs continue, system operation and control will need to change dramatically for improved grid reliability and resiliency. As renewable resources increase in penetration, new and challenging operational, planning, and design problems are expected to emerge. Some of the key challenges that arise in the planning and operation of the future grid are: 1) Quantifying the impact of high DER penetration in distribution systems on bulk grid behavior over multiple time scales. 2) Identifying whether a particular DER configuration/settings have a large impact on the overall grid behavior. These challenges can be addressed in an offline manner using detailed T&D grid models and they can also be addressed in an online manner using sensor measurements. In particular, the advancement and planned growth in sensor technology in power grid over various voltage levels provide us with a unique opportunity to tackle these challenges from a data analytic perspective without needing detailed T&D grid models. A few questions that naturally arise when addressing the challenges from DERs using sensor data are: 1) How can we use limited sensor measurements to monitor & control voltage stability and small signal stability of the bulk system? 2) How can we ensure that the developed data analytic methods are robust to data availability and quality issues? 3) How can we compute the developed analytics in a scalable manner using streaming measurements? In this project, we addressed the aforementioned challenges arising from DERs and answered the questions raised above on how to effectively use the sensor measurements to enhance the reliability and performance of the electric grid. Thus, the overarching goal of this project is to develop effective reduced/representative system models from data that make the computational complexity sufficiently manageable so as to be useful to simulate, analyze, and even control complex non-linear power systems dynamics with large penetrations of DERs. In order to achieve the objective, the project team established a four-fold technical approach 1) Formulated a combined transmission-distribution co-simulation framework for data generation and validation, 2) Derived reduced/representative models of power systems based on data-driven methods for efficient computation and appropriate representation of system behavior, 3) Developed data driven characterization of power system behavior based on transfer operator theory, machine learning and optimization for model estimation, 4) Incorporated a scalable data management and processing architecture using distributed Kafka streaming applications that coordinate input data streams to the developed data analytics. The key accomplishments of the project are: 1) Development of a scalable multi-timescale T&D co-simulation framework (both for steady state and for dynamic co-simulation) using commercial solvers (PSSE and GridLAB-D). The steady-state T&D co-simulation interface is shared with our industry partner (PJM). 2) A structured reduced order dynamic model of distribution systems that can represent partial motor stalling along with a systematic procedure to derive the model parameters. 3) A PMU based online method to monitor, localize and mitigate fault-induced delayed voltage recovery using DER reactive support and load control in distribution systems. 4) Development of linear operator based robust methodologies for dynamic state estimation, uncertainty quantification, system identification and trajectory prediction for power system dynamics. 5) An adaptive damping control for utilizing wind energy resources to provide oscillation damping and system stability. 6) Implementation of Kafka-based framework for efficient processing of streaming data using Linux-based local virtual environment.

DER integration↗

The effect of metal-contacts on carbon nanotube for high frequency interconnects and devices

High frequency characterisation of platinum and tungsten contacts on individual multi-walled carbon nanotubes (MWNT) is performed from 10 MHz to 50 GHz. By measuring the scattering parameters of aligned individual MWNTs, we show that metal contacts enhance an inductive response due to the improved MWNT-electrode coupling reducing the capacitive effect. This behaviour is pronounced in the frequency below 10 GHz and strong for tungsten contacts. We explain the inductive response as a result of the interaction of stimulus current with the localized (or defects) states present at the contact region resulting in the current lagging behind the voltage. The results are further supported by direct current measurements that show tungsten to significantly increase carbon nanotube-electrode coupling. The immediate consequence is the reduction of the contact resistance, implying a reduction of electron tunnelling barrier from the electrode to the carbon nanotube.

36 MATERIALS SCIENCE↗