Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Physics-Informed Graph Neural Networks for Collaborative Dynamic Reconfiguration and Voltage Regulation in Unbalanced Distribution Systems

Network reconfiguration has long been employed as a strategic approach to minimize power distribution system losses and effectively regulate voltage levels. Tap-changing voltage regulators are also critical for controlling bus voltages, especially in accommodating the increasing integration of distributed energy resources (DERs) with intermittent outputs. This paper introduces novel methodologies to address the challenges of dynamic reconfiguration and optimal tap setting in unbalanced three-phase distribution systems. We propose an approximated mixed-integer quadratically constrained program (MIQCP) to model dynamic reconfiguration, along with a pioneering formulation for voltage regulator (VR) tap-setting based on Special Ordered Set type 1 (SOS1). To mitigate computational complexity, we propose a physics-informed spatial-temporal graph convolutional network (STGCN) with an integrated link classifier. The proposed approach enables efficient solution generation by fixing specific variables in the MIQCP instance and solving the simplified sub-MIP using an MIP solver. Numerical studies demonstrate the superior prediction accuracy of our STGCN model compared to baseline neural network models, resulting in reduced DER curtailment and voltage deviation with shorter computation time.

dynamic reconfiguration↗

A Comparison of DER Voltage Regulation Technologies Using Real-Time Simulations

Grid operators are now considering using distributed energy resources (DERs) to provide distribution voltage regulation rather than installing costly voltage regulation hardware. DER devices include multiple adjustable reactive power control functions, so grid operators have the difficult decision of selecting the best operating mode and settings for the DER. In this work, we develop a novel state estimation-based particle swarm optimization (PSO) for distribution voltage regulation using DER-reactive power setpoints and establish a methodology to validate and compare it against alternative DER control technologies (volt–VAR (VV), extremum seeking control (ESC)) in increasingly higher fidelity environments. Distribution system real-time simulations with virtualized and power hardware-in-the-loop (PHIL)-interfaced DER equipment were run to evaluate the implementations and select the best voltage regulation technique. Each method improved the distribution system voltage profile; VV did not reach the global optimum but the PSO and ESC methods optimized the reactive power contributions of multiple DER devices to approach the optimal solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental Analysis of Distribution Network Voltage Regulation Using Smart Inverters: Preprint

Smart inverters (SI) have huge potential in providing grid services which has not been fully realized yet. One of these grid services, distribution network voltage regulation by SI, can improve the network voltage by regulating the SI reactive and active power output. Voltage regulation by SI is much faster compared to traditional voltage regulating devices, e.g. tap changing transformer, capacitor banks. However, there is gap in available published literature on the characteristics of SIs when the SI is controlled by local controller or external control signal. This paper presents the experimental study to characterize SI reactive power regulation response to two different control methods: autonomous control method and remote dispatch method. It was found that IS reactive power regulation response could be significantly different in terms of delay, and ramp rate for these two methods. Finally, Power-Hardware-in-The-Loop (PHIL) tests were conducted to evaluate the performance of these two methods. The PHIL tests results show that SI response characteristics for autonomous control method and remote dispatch method need to be considered during planning for distribution network voltage regulation using SI.

autonomous control↗

Quantitative Decoupling of Oxygen-Redox and Manganese-Redox Voltage Hysteresis in a Cation-Disordered Rock Salt Cathode

Pronounced voltage hysteresis in Li-excess cathode materials is commonly thought to be associated with oxygen redox. However, these materials often possess overlapping oxygen and transition-metal redox, whose contributions to hysteresis between charge and discharge are challenging to distinguish. In this work, a two-step aqueous redox titration is developed with the aid of mass spectrometry (MS) to quantify oxidized lattice oxygen and Mn 3+/4+ redox in a representative Li-excess cation-disordered rock salt—Li 1.2 Mn 0.4 Ti 0.4 O 2 (LMTO). Two MS-countable gas molecules evolve from two separate titrant-analyte reactions, thereby allowing Mn and O redox capacities to be decoupled. The decoupled O and Mn redox coulombic efficiencies are close to 100% for the LMTO cathode, indicating high charge-compensation reversibility. As incremental Mn and O redox capacities are quantitatively decoupled, each redox voltage hysteresis is further evaluated. Overall, LMTO voltage hysteresis arises not only from an intrinsic charge-discharge voltage mismatch related to O redox, but also from asymmetric Mn-redox overvoltages. The results reveal that O and Mn redox both contribute substantially to voltage hysteresis. In conclusion, this work further shows the potential of designing new analytical workflows to experimentally quantify key properties, even in a disordered material having complex local coordination environments.

25 ENERGY STORAGE↗

Microbial community diversity changes during voltage reversal repair in a 12-unit microbial fuel cell

Microbial fuel cell stacks (MFC-Stack) are often confronted with voltage reversals, likely due to an interplay between microbial community dynamics and insufficient electric circuit balancing. Herein, we provide new insight into voltage reversals by examining the microbiomes of twelve MFC units of a 12-liter Pilot-MFC-Stack during repair. Different biofilm repair methods (self-healing, electrostimulation, and re-acclimatization upon cross-inoculation) were used to evaluate the microbial community response. In addition, MFC-Stack simulation was performed based on Kirchhoff’s Second Law to predict values for source potentials and post-evaluate internal resistances. Analysis of the 16S rRNA amplicon sequencing data suggests that the biofilm repair methods could slowly heal damaged biofilms. Notably, severely voltage reversed MFC units had low electrogen relative abundances (18%) and positive anode potentials, while strong bioanodes and contained more than 50% electrogens and had negative anode potentials. Between-community analyses (beta diversity ordination and multinomial regression) of the voltage reversed MFC units revealed differences among biofilms in contrast to healthy/strong MFC units. Permutational multivariate analysis of variance (PERMANOVA) confirmed that reversed biofilms were, indeed, significantly (p < 0.05) different from stronger ones. Overall, these analyses demonstrated the utility of combining electrotechnical and microbial community analyses, especially beta diversity ordination and multinomial regression, to understand problematic MFC units and the potential success of a biofilm repair method. Finally, thicker biofilms were usually healthier and stronger, although thickness was no guarantee for proper structure and power function as all factors were interdependent. There was an evolutionary trend that strong anodes became stronger/healthier and others weaker. This spontaneous trend has to be considered to avoid irreversible voltage reversals and to repair electrogenic biofilms in an MFC-Stack.

59 BASIC BIOLOGICAL SCIENCES↗

Voltage-Dependent Barrier Height of Electron Transport through Iron Porphyrin Molecular Junctions

Electron transport through iron porphyrin (FeP) molecules self-assembled on a gold (Au) substrate was investigated using conductive atomic force microscopy (AFM) to measure current–voltage (I–V) characteristics. In the direct tunneling region (|V| ≤ 0.1 V), the Simmons model was used to characterize the electron transport. Furthermore, the energy barrier between the Fermi energy level of Au and the highest occupied molecular orbital (HOMO) level of the FeP molecule was determined to be between 0.3 and 0.6 eV; the range of the electron attenuation coefficient was 0.6–0.8 Å–1. Instead of a constant barrier height, a voltage-dependent barrier height was adapted to simulate the experimental I–V curves over the entire voltage range (|V| ≤ 2 V) using the Simmons model for the intermediate case. The voltage-dependent barrier height is supported by a previously predicted response of molecular-projected self-consistent Hamiltonian orbitals. The dependence showed that the HOMO level relative to the Fermi energy level of the Au electrode decreased as the bias voltage increased. To verify the deposition of the FeP on the Au substrate, Raman spectroscopy and AFM analysis were performed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Operation of Layered LiCoO 2 to Higher Voltages with a Localized Saturated Electrolyte

The commercialization of lithium-ion batteries started with the layered LiCoO 2 (LCO) cathode for portable electronics, but only 50% of its theoretical capacity can be used in practical cells due to detrimental surface and bulk degradations when charged to high voltages. Here we demonstrate here that the stability of electrolyte plays a critical role in the performance of LCO at high voltages by employing a localized saturated electrolyte (LSE). With a cutoff voltage of 4.5 V, LCO achieves an initial 1C discharge capacity of 176 mA h g -1 and a capacity retention of 80% over 230 cycles. Even with a cutoff voltage of 4.6 V, LCO with 2% aluminum doping displays an initial discharge capacity of 189 mA h g -1 at 1C rate with 80% capacity retention over 137 cycles. With extensive analytical characterization, we show that the improved cycling stability stems from a suppression of the O3 to H1-3 phase transition as well as a robust inorganic-rich cathode-electrolyte interphase (CEI) facilitated by the LSE. This work highlights the importance of protecting the surface as well as the bulk with appropriate electrolytes for the high-voltage, higher-energy-density operation of LCO.

25 ENERGY STORAGE↗

Voltage decay and redox asymmetry mitigation by reversible cation migration in lithium-rich layered oxide electrodes

Despite the high energy density of lithium-rich layered-oxide electrodes, their real-world implementation in batteries is hindered by the substantial voltage decay on cycling. This voltage decay is widely accepted to mainly originate from progressive structural rearrangements involving irreversible transition-metal migration. As prevention of this spontaneous cation migration has proven difficult, a paradigm shift toward management of its reversibility is needed. Herein, we demonstrate that the reversibility of the cation migration of lithium-rich nickel manganese oxides can be remarkably improved by altering the oxygen stacking sequences in the layered structure and thereby dramatically reducing the voltage decay. The preeminent intra-cycle reversibility of the cation migration is experimentally visualized, and first-principles calculations reveal that an O2-type structure restricts the movements of transition metals within the Li layer, which effectively streamlines the returning migration path of the transition metals. Furthermore, we propose that the enhanced reversibility mitigates the asymmetry of the anionic redox in conventional lithium-rich electrodes, promoting the high-potential anionic reduction, thereby reducing the subsequent voltage hysteresis. Our findings demonstrate that regulating the reversibility of the cation migration is a practical strategy to reduce voltage decay and hysteresis in lithium-rich layered materials.

25 ENERGY STORAGE↗

Analog-to-digital converter based on voltage-controlled superconducting devices

The increasing demand for cryogenic electronics in superconducting and quantum computing systems calls for ultra-energy-efficient data conversion architectures that remain functional at deep cryogenic temperatures. Here, in this work, we present the first design of a voltage-controlled superconducting flash analog-to-digital converter (ADC) based on a voltage-controlled quantum-enhanced Josephson junction field-effect transistor (JJFET). Exploiting its strong gate tunability and transistor-like behavior, the JJFET offers a scalable alternative to conventional current-controlled superconducting devices while aligning naturally with CMOS-style design methodologies. Building on our previously developed Verilog-A compact model calibrated to experimental data, we design and simulate a three-bit JJFET-based flash ADC targeted for integration within cryogenic control and readout circuitry in quantum computing. The core comparator block is realized through careful bias current selection and augmented with a three-terminal nanocryotron to precisely define reference voltages. Cascaded JJFET comparators ensure robust voltage gain, cascadability, and logic-level restoration across stages. Simulation results demonstrate accurate quantization behavior with ultra-low power dissipation, underscoring the feasibility of voltage-driven superconducting mixed-signal circuits. This work establishes a critical step toward unifying superconducting logic and data conversion, paving the way for scalable cryogenic architectures in quantum–classical co-processors, low-power artificial intelligence accelerators, and next-generation energy-constrained computing platforms.

Analog-to-digital converter↗

Structural basis for severe pain caused by mutations in the S4-S5 linkers of voltage-gated sodium channel Na V 1.7

Gain-of-function mutations in voltage-gated sodium channel Na V 1.7 cause severe inherited pain syndromes, including inherited erythromelalgia (IEM). The structural basis of these disease mutations, however, remains elusive. Here, we focused on three mutations that all substitute threonine residues in the alpha-helical S4-S5 intracellular linker that connects the voltage sensor to the pore: Na V 1.7/I234T, Na V 1.7/I848T, and Na V 1.7/S241T in order of their positions in the amino acid sequence within the S4-S5 linkers. Introduction of these IEM mutations into the ancestral bacterial sodium channel Na V Ab recapitulated the pathogenic gain-of-function of these mutants by inducing a negative shift in the voltage dependence of activation and slowing the kinetics of inactivation. Remarkably, our structural analysis reveals a common mechanism of action among the three mutations, in which the mutant threonine residues create new hydrogen bonds between the S4-S5 linker and the pore-lining S5 or S6 segment in the pore module. Because the S4-S5 linkers couple voltage sensor movements to pore opening, these newly formed hydrogen bonds would stabilize the activated state substantially and thereby promote the 8 to 18 mV negative shift in the voltage dependence of activation that is characteristic of the Na V 1.7 IEM mutants. Our results provide key structural insights into how IEM mutations in the S4-S5 linkers may cause hyperexcitability of Na V 1.7 and lead to severe pain in this debilitating disease.

60 APPLIED LIFE SCIENCES↗

Medium Voltage Converter Inductor Insulation Design Considering Grid Insulation Requirements

Medium voltage SiC devices facilitate direct (without 50/60 Hz transformer) connection of the power electronics converter to the medium voltage grid using simple topology. Compared to the insulation design of medium voltage inductors that have been widely used in the power system, the insulation design of directly connected medium voltage converter filter inductors has more challenges. Although some works has been done discussing that, the grid insulation requirements on converter filter inductors are rarely discussed. This paper introduces the insulation design of a grid-side filter inductor for a 13.8 kV power conditioning system converter. The grid insulation requirements, including the short-duration power frequency overvoltage and the lightning impulse voltage, are considered in the design. To meet the requirements, the layer-to-layer insulation, winding-to-core/ground insulation, the air gap discharge between the winding and the core, as well as the local electrical field have been taken into consideration. Experimental tests are provided to validate the design.

Li, Haiguo↗

Medium Voltage Solid State Transformer for Extreme Fast Charging Applications

A modular and scalable solid state transformer (SST) with direct medium voltage (MV) AC connectivity is proposed to enable DC extreme fast charging (XFC) of electric vehicles. Single-phase-modules (SPMs), each consisting of an active-front-end (AFE) stage and an isolated DC-DC stage, are connected in input-series-output-parallel (ISOP) configuration. The modular hardware is co-designed with decentralized control of the DC-DC stages where voltage and power balancing are achieved by each SPM using only its local sensor feedback; a centralized controller (CC) regulates the low voltage (LV) DC bus through the AFE stages without any sensor feedback form the SPMs. The controller architecture contrasts sharply with the prior art for MV AC to LV DC SSTs where high-speed bidirectional communication among SPMs and a CC are required for module-level voltage and power balancing, which severely limits the scalability and practical realization of higher voltage and higher power units. Detailed small-signal analysis and controller design guidelines are developed. Furthermore, a soft start-up strategy is presented. The proposed converter and control structure are validated through simulation and experimental results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Ultra-Fast Inrush-Current-Free Startup Method for Grid-tie Inverter without Voltage Sensors

This paper proposes an ultra-fast inrush-currentfree startup method for grid-tie inverters without voltage sensors and phase-locked loop (PLL). Traditionally, the grid-tie inverter needs the voltage measured from points of common couplings (PCC) to generate the phase angle via PLL for inverter pulsewidth- modulation (PWM) signals. The startup procedure is slow and inrush current occurs if the initial PWM does not match the unknown grid voltage well. This paper proposes a startup method that only uses measured inverter ac currents to generate the initial PWM by controlling the current to zero. The generated PWM pattern can be used to reproduce the real grid voltage regardless of the grid impedance. The zero-crossing points of the grid voltage are detected and then used for grid synchronization. The proposed startup procedure only needs a few cycles (16.67 ms/cycle) to reliably synchronize the inverter to the grid without any inrush current. Simulation and experimental results are presented to verify the effectiveness of this control strategy.

He, Yuchen↗

Dynamic Model of Active Front-End Converters with 2DOF-PI Controllers for DC Bus Voltage Control

In most of the research, a conventional one degree-of-freedom type proportional-integral controller (1DOF-PI) is used for the regulation of the dc bus voltage in an Active Front-End Converter (AFEC). This paper proposes a two degree-of-freedom type proportional-integral controller (2DOF-PI) for the regulation of dc bus voltage in an AFEC. Such a controller eliminates the left-half plane (LHP) zero in the command-to-output transfer function for dc bus voltage regulation that is inherent to the conventional 1DOF-PI for this application. The dynamic model of an AFEC in the synchronous reference frame (SRF) is presented. An inner current control and outer dc voltage control loop is built for controlling the AFEC. Vector-control scheme is employed to achieve decoupled control of direct-axis and quadrature-axis currents. The outer dc voltage control loop is designed with a 2DOF-PI to complete the control system. Transfer function (TF) of the controller is derived based on the presented model and used to calculate the controller gains. Transient and steady state performance of the designed controllers are investigated in MATLAB/Simulink and results presented.

Thapa, Anup↗

Investigation of Dynamic Temperature-Sensitive Electrical Parameters for Medium-Voltage Low-Current Silicon Carbide and Silicon Devices

This paper presents five dynamic temperature-sensitive electrical parameters (TSEPs) for the medium-voltage silicon carbide (SiC) and silicon (Si) devices. The theoretical temperature dependence of these parameters is analyzed. A test platform that enables to implement the temperature relevant dynamic characterization is developed. The tested TSEPs are summarized in terms of their relationship with junction temperature, drain/collector current, DC voltage, and external gate resistance. The comparison between the 3 kV 12 A Si IGBT and 3.3 kV 5 A SiC MOSFET with the identical TO-263 package is conducted. The results verify that the turn-off drain-source voltage switching rate achieves better thermal sensitivity for medium-voltage low-current SiC MOSFETs compared with Si IGBTs. Both the turn-on and turn-off delay time exhibit better thermal linearity for the two devices. The turn-off delay time further achieves five times better thermal sensitivity than the turn-on delay time for investigated medium-voltage SiC MOSFETs.

Ni, Ze↗

Grid-Tied PV Inverter with Oversized Power Module to Increase its Low-Voltage Ride Through (LVRT) Capabilities and VAR Support

This paper proposes a novel design for grid-tied 3-ph Photovoltaic (PV) inverter to improve its low-voltage ride through (LVRT) response while significantly increasing its voltampere reactive (VAR) support during voltage sags. The literature available on LVRT for PV inverters can be grouped in solutions that dissipate the excess energy and those that temporary stores this energy. This paper proposes a third solution; oversizing inverter hardware components to safely transferring all the energy excess back to while maintaining the semiconductor under the maximum temperature limits. The advantages of the proposed approach are: 1) Improved LVRT capabilities and stable dc-link voltage control at MPP during sags. 2) Increased VAR support during voltage sags. 3) Increased use of renewable energy as all active power is injected back to the grid during voltage sags. Finally, the proposed solution is more cost effective compared with solutions that incorporate energy storage because only a few inverter components are required to be oversized. This paper also presents a detailed power loss analysis, which determined that that oversizing the power semiconductors has minimal impact in the inverter losses while significatively reducing the diode and IGBT conduction losses during both normal operation and grid fault conditions.

Ferrari Maglia, Max↗

Model-Free Dynamic Voltage Control of a Synchronous Generator-Based Microgrid

The main goal of this paper is to present a new dynamic voltage stability mechanism, based on model-free control (MFC), for effective control and coordination of synchronous generator (SG)-based reactive power resources in a microgrid setting. MFC has shown successful operation in various domains, and this paper presents its first use in the voltage stability of a power system. It is utilized as an online controller to achieve the dynamic voltage stability of a microgrid system under different disturbances and fault conditions. A 21-bus microgrid system fed by SG-based distributed energy resources (DERs) is considered as a use case study. The overall dynamic voltage stability of the microgrid system is investigated using time-domain dynamic simulations during emergency, hazard, and disaster events. Simulation results show that there are significant improvements and enhancements on the dynamic load bus voltage profiles of the microgrid system by the effective model-free control and coordination of the reactive power reserves of the SG-based DERs.

Hatipoglu, Kenan↗

Voltage Restoration in Microgrids using Temporal Logic Specifications

This paper proposes an energy storage controller synthesis method for voltage restoration in microgrids with respect to temporal logic specifications (TLSs). TLSs is introduced in this paper as a formalism to control the voltage variation of a critical bus against an operational bounds over time. The power system with synchronous generator (SG) connected to a critical load bus is modeled as a set of differential-algebraic equations and a simplified analytical model is derived to describe the voltage variation of this critical bus. The control objective is to schedule an optimal control input signal from a supportive energy storage system (ESS) connected to the critical bus, such that the voltage variation of the latter satisfies the TLSs, such as a finite-time restoration. The proposed control is verified on a lumped distribution system model. With this control diagram, supportive controllers can be designed to make voltage behaviors comply with grid codes and avoid unnecessary relay actions.

Taousser, Fatima Zohra↗