Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Iodine Electrochemistry Dictates Voltage‐Induced Halide Segregation Thresholds in Mixed‐Halide Perovskite Devices

Abstract Owing to straightforward stoichiometry–bandgap tunability, mixed‐halide perovskites are ideal for many optoelectronic devices. However, unwanted halide segregation under operational conditions, including light illumination and voltage bias, restricts practical use. Additionally, the origin of voltage‐induced halide segregation is still unclear. Herein, a systematic voltage threshold study in mixed bromide/iodide perovskite devices is performed and leads to observation of three distinct voltage thresholds corresponding to the doping of the hole transport material (0.7 ± 0.1 V), halide segregation (0.95 ± 0.05 V), and degradation (1.15 ± 0.05 V) for an optically stable mixed‐halide perovskite composition with a low bromide content (10%). These empirical threshold voltages are minimally affected by composition until very Br‐rich compositions, which reveals the dominant role of iodide/triiodide/iodine electrochemistry in voltage‐induced Br/I phase separation and transport layer doping reactions in halide perovskite devices.

36 MATERIALS SCIENCE↗

Whole-Voltage-Range Oxygen Redox in P2-Layered Cathode Materials for Sodium-Ion Batteries

Oxygen-redox of layer-structured metal-oxide cathodes has drawn great attention as an effective approach to break through the bottleneck of their capacity limit. However, reversible oxygen-redox can only be obtained in the high-voltage region (usually over 3.5 V) in current metal-oxide cathodes. Here, we realize reversible oxygen-redox in a wide voltage range of 1.5-4.5 V in a P2-layered Na 0.7 Mg 0.2 [Fe 0.2 Mn 0.6 $\square$0.2]O 2 cathode material, where intrinsic vacancies are located in transition-metal (TM) sites and Mg-ions are located in Na sites. Mg-ions in the Na layer serve as "pillars" to stabilize the layered structure during electrochemical cycling, especially in the high-voltage region. Intrinsic vacancies in the TM layer create the local configurations of "$\square$-O-$\square$", "Na-O-$\square$" and "Mg-O-$\square$" to trigger oxygen-redox in the whole voltage range of charge-discharge. Additionally, time-resolved techniques demonstrate that the P2 phase is well maintained in a wide potential window range of 1.5-4.5 V even at 10 C. It is revealed that charge compensation from Mn- and O-ions contributes to the whole voltage range of 1.5-4.5 V, while the redox of Fe-ions only contributes to the high-voltage region of 3.0-4.5 V. The orphaned electrons in the nonbonding 2p orbitals of O that point toward TM-vacancy sites are responsible for reversible oxygen-redox, and Mg-ions in Na sites suppress oxygen release effectively.

25 ENERGY STORAGE↗

Interface Coating Design for Dynamic Voltage Stability of Solid‐State Batteries

Abstract Intrinsic or interface thermodynamic voltage windows of solid electrolytes are often narrower than the operational voltage range needed by a full battery, thus various interface decomposition reactions can happen in a practical solid‐state battery. Experimentally, it is found that a proper battery design utilizing the reactions can lead to a dynamic evolution from interface instability to stability, giving the so‐called dynamic voltage stability for advanced battery performance. Here, first the state‐of‐the‐art understanding is articulated about how the dynamic voltage stability should be interpreted in physical picture and treated in computation, emphasizing the potential importance of nonequilibrium reaction pathways. The constrained ensemble computational approach is further applied across most types of solid‐state electrolytes to systematically evaluate and compare their dynamic stability voltage windows in response to the mechanical constriction effect. High‐throughput calculations are used to search for coating materials for different interfaces between sulfide, halide, and oxide electrolytes and typical cathode materials with enhanced dynamic voltage stability. A comparison with experiment is given to highlight the value of these computational predictions.

Wang, Yichao↗

Stabilizing a strongly nonlinear structure through shaker dynamics in fixed frequency voltage control tests

Bifurcations are commonly encountered during force controlled swept and stepped sine testing of nonlinear structures, which generally leads to the so-called jump-down or jump-up phenomena between stable solutions. There are various experimental closed-loop control algorithms, such as control-based continuation and phase-locked loop, to stabilize dynamical systems through these bifurcations, but they generally rely on specialized control algorithms that are not readily available with many commercial data acquisition software packages. A recent method was developed to experimentally apply sequential continuation using the shaker voltage that can be readily deployed using commercially available software. By utilizing the stabilizing effects of electrodynamic shakers and the force dropout phenomena in fixed frequency voltage control sine tests, this approach has been demonstrated to stabilize the unstable branch of a nonlinear system with three branches, allowing for three multivalued solutions to be identified within a specific frequency bandwidth near resonance. Recent testing on a strongly nonlinear system with vibro-impact nonlinearity has revealed jumping behavior when performing sequential continuation along the voltage parameter, like the jump phenomena seen during more traditional force controlled swept and stepped sine testing. Here, this paper investigates the stabilizing effects of an electrodynamic shaker on strongly nonlinear structures in fixed frequency voltage control tests using both numerical and experimental methods. The harmonic balance method is applied to the coupled shaker-structure system with an electromechanical model to simulate the fixed voltage control tests and predict the stabilization for different parameters of the model. The simulated results are leveraged to inform the design of a set of experiments to demonstrate the stabilization characteristics on a fixture-pylon assembly with a vibro-impact nonlinearity. Through numerical simulation and experimental testing on two different strongly nonlinear systems, the various parameters that influence the stability of the coupled shaker-structure are revealed to better understand the performance of fixed frequency voltage control tests.

42 ENGINEERING↗

Long-Term Cyclability of NCM-811 at High Voltages in Lithium-Ion Batteries: an In-Depth Diagnostic Study

High-nickel layered oxides, such as LiNi 0.8 Co 0.1 Mn 0.1 O 2 (NCM-811), offer higher energy density than their low-nickel counterparts at a given voltage and are gaining major traction in automotive lithium-ion batteries for electric vehicles. Besides high-Ni content, higher charging voltages above 4.3 V vs Li + /Li boost the energy and represent another focus in battery development. Here, we investigate the long-term cyclability of NCM-811 in graphite pouch cells over 1000 deep cycles between 2.5–4.2, 2.5–4.4, and 2.5–4.5 V through a suite of sensitive characterization techniques. The NCM-811 full cells show severely deteriorated cyclability with higher charging voltages, from 78% at 4.2 V to 52 and 32% at 4.4 and 4.5 V, respectively. At 4.2 V, minor parasitic electrolyte oxidation as well as cathode Li/Ni mixing and cracking are revealed after cycling, while transition-metal dissolution and surface reconstruction into rock-salt NiO are virtually undetectable. At 4.4 and 4.5 V, transition-metal dissolution and crossover to the anode become much more pronounced and a primary contributor to the capacity fade, while significant surface NiO formation causes substantial voltage polarization, which is less noticeable at 4.2 V. Meanwhile, more severe electrolyte oxidation, Li/Ni mixing, and particle pulverization exacerbate the voltage and capacity fade. Finally, these results outline distinct challenges for stable high-Ni layered oxide cathodes in high-voltage Li-ion batteries.

25 ENERGY STORAGE↗

Suppression of voltage-decay in Li 2 MnO 3 cathode via reconstruction of layered-spinel coexisting phases

Voltage decay, i.e., the voltage decrease during electrochemical cycling, has been a decade-long challenge for lithium-ion batteries. This issue not only leads to a substantial loss of energy density, but also raises challenges for the battery management system, hindering the commercial application of high capacity lithium-rich oxide. Here, we show that through a combination of electrochemical conditioning and thermal treatment, Li 2 MnO 3 , the parent compound of lithium-rich oxide, which typically displays severe voltage and capacity decay, could be converted into a new phase that essentially suppresses the voltage decay with improved capacity retention and rate performance. Furthermore, by combining atomic-sensitive nuclear magnetic resonance, differential electrochemical mass spectrometry and synchrotron-based resonant inelastic X-ray scattering, we disclose that treatment triggers the formation of three-coexisting phases, i.e., the lithium-rich layered, spinel and defect spinel phases, which enables improved reversibility of the oxygen redox activity and enhanced manganese redox reactions in the initial cycle. Our findings suggest the key role of the local structure in the voltage decay problem and provide insights for material optimizations towards lithium- and manganese-rich cathodes without the voltage decay.

25 ENERGY STORAGE↗

Structural basis for severe pain caused by mutations in the voltage sensors of sodium channel NaV1.7

Voltage-gated sodium channels in peripheral nerves conduct nociceptive signals from nerve endings to the spinal cord. Mutations in voltage-gated sodium channel NaV1.7 are responsible for a number of severe inherited pain syndromes, including inherited erythromelalgia (IEM). Here, we describe the negative shifts in the voltage dependence of activation in the bacterial sodium channel NaVAb as a result of the incorporation of four different IEM mutations in the voltage sensor, which recapitulate the gain-of-function effects observed with these mutations in human NaV1.7. Crystal structures of NaVAb with these IEM mutations revealed that a mutation in the S1 segment of the voltage sensor facilitated the outward movement of S4 gating charges by widening the pathway for gating charge translocation. In contrast, mutations in the S4 segments modified hydrophobic interactions with surrounding amino acid side chains or membrane phospholipids that would enhance the outward movement of the gating charges. These results provide key structural insights into the mechanisms by which these IEM mutations in the voltage sensors can facilitate outward movements of the gating charges in the S4 segment and cause hyperexcitability and severe pain in IEM. Our work gives new insights into IEM pathogenesis at the near-atomic level and provides a molecular model for mutation-specific therapy of this debilitating disease.

60 APPLIED LIFE SCIENCES↗

Enhancing nitrogen fixation efficiency in glow-like discharge by reducing cathode-fall voltage

In plasma nitrogen fixation devices, discharge electrodes are crucial yet susceptible to oxidation and corrosion due to plasma’s high temperatures and oxygen content, which could alter discharge modes. This research evaluates the impact of different electrode materials, including iron, chromium, nickel, copper, and 304 stainless steel, on nitrogen fixation efficiency in glow-like discharges driven by high-voltage DC power. Notably, iron and 304 stainless steel cathodes undergo a mode transition at increased currents, evident from plasma color shifts and significant voltage reductions. Fourier transform infrared spectroscopy analyses reveal that such mode changes minimally affect nitrogen oxide production rates, leading to a notable decrease in energy consumption for nitrogen fixation by up to 40%. OES and SEM-EDS measurements suggest that iron oxide, with its higher secondary electron emission, replaces metal as the cathode material, facilitating mode transitions and maintaining discharge current at lower voltages. Further, this voltage change is largely attributed to the cathode voltage drop, highlighting the minimal role of the cathode fall region in NO x synthesis. These findings underscore the potential for improving plasma nitrogen fixation energy efficiency by choosing suitable cathode materials to lower the cathode-fall voltage.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of Auxiliary Power Supply for Medium Voltage Applications

Typical voltage levels from medium-voltage (MV) applications introduce additional challenges to designing the auxiliary power supply (APS) necessary to provide power to the secondary circuits of the main converter. This paper aims to present the design of a 100 W APS for 0.6–2 kV input DC voltage and 24 V output. The selected architecture addresses the medium voltage to low voltage challenge by adopting two stage approach – a simple robust DC transformer (DCX) stage and a low voltage regulation stage. The design of the main building blocks of the APS are described followed by simulation results.

Magri Kimpara, Marcio↗

A Medium Voltage Three-Stage Power Converter Topology for Distribution Grid Scale Energy Storage Systems

This work proposes a three-stage converter topology with a medium frequency isolation transformer for direct integration of energy storage systems into medium voltage distribution grids. The distributed architecture of the topology, using standard AC/DC converters, has been developed with the aim of plug-and-play capability and voltage and power scalability. The medium frequency transformer facilitates improved power density, while its 20:1 voltage translation capability enables the use of limited voltage level (500 Vdc) of the commercially available batteries. This paper presents the topology structure and details how it can be scaled to reach the full range of the distribution grid voltages and the required power levels. A transformer design for 500 Hz rated frequency is discussed. The control scheme of the converter equipped with voltage support, frequency support, and black start capabilities is also presented. Control hardware-in-the-loop results using OPAL-RT, with converter switching models connected to a weak IEEE-4 node test feeder modified for the aforementioned grid services, are provided to show the topology feasibility.

Chinthavali, Madhu Sudhan↗

Optimal Voltage Control in Low-Observable Unbalanced Distribution Systems

The increased integration of distributed energy resources (DERs) in distribution systems brings both advantages and technical challenges. High levels of DERs can often cause over/under voltage problems. Classical voltage control algorithms are based on full knowledge of voltage states across all nodes in the system. However, this may not be a practical assumption since many locations in distribution systems are unobservable. Therefore, this paper proposes a new model predictive control (MPC) based control algorithm that accounts for system unobservability to efficiently eliminate voltage violations with as low as 50% fraction of observable nodes. Additionally, an analytical voltage sensitivity framework is employed to quickly determine the change in voltage states due to PV injections. The effectiveness of the proposed method is validated via simulations on the unbalanced IEEE 37 node test system.

Abujubbeh, Mohammad↗

Inverse Segmented Motor Drive Using Dual ANPC Inverters for Common-Mode Voltage and Neutral-Point Current Cancellation

This article proposes an inverse segmented motor drive (SgMD) utilizing dual active neutral point clamped (ANPC) inverters. In the proposed configuration, the neutral point current and common-mode (CM) voltage is topologically canceled, achieving zero total neutral point current and CM voltage under ideal conditions. Also, the zero total neutral point current minimizes the neutral point voltage imbalance in ANPC inverters. The mechanisms behind neutral point current and CM voltage cancellation in the proposed inverse SgMD are first introduced. The modifications to the motor windings for implementing the inverse SgMD are explained, showing that a standard motor can be readily adapted for the proposed configuration. A space vector modulation (SVM) scheme tailored for the proposed topology is presented, along with a carrier-based implementation. Simulation results validate that the proposed topology can achieve zero total CM voltage and neutral point current. It is also shown that the proposed inverse SgMD can reduce neutral point voltage fluctuation by about 90% and RMS current stress in the dc-link capacitors by about 43% compared to the conventional SgMD.

Lee, Sangwhee [ORNL] (ORCID:0000000335490057)↗

Distributed Secondary Control of Grid-Forming Inverters and AC Microgrids: Impacts of Voltage Feedback Choices

In this paper, the operational choices in distributed secondary control are examined, and their impacts on grid-forming (GFM) inverters and grid operation are investigated. In particular, the effects of feedback voltage choices, either average voltage feedback (AVF) or terminal voltage feedback (TVF), are studied with respect to reactive power sharing, voltage regulation, and grid-forming operation during black start. The secondary control used is a subgradient-based distributed cooperative control, and it provides the voltage, angle, and frequency references to the GFM inverters and their primary tracking controls. The overall control architecture employs multi-rate sampling such that the secondary control is slower than the primary control. The operational choices and their control performance are illustrated using a four-GFM-inverter microgrid in MATLAB/SIMULINK. Furthermore, the results show the effectiveness of the secondary controller, and several conclusions are drawn on the voltage feedback signals as the design choices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High Voltage Surge Protection by a Varistor-Filled Air Gap

The electric discharge across a varistor granule filled air gap under a fast-rising voltage pulse was investigated for surge protection applications. The effects of temperature and pressure on the arc and the electrical conduction were analyzed by the characteristic changes in voltage waveforms triggered by a fast-rising high voltage pulse. In addition to the gap size, experimental results show that competing mechanisms among arc conduction, conduction through the varistor granule network, thermionic emission from Joule heating at granule-to-granule contact points, and the magnitude of the switching voltage dictate the maximum surge protection voltage for the filled air gap. Experimental evidence indicated that accumulated degradation was created at small contact points between varistor granules by repetitive assaults from longer duration, high voltage pulses. The uniqueness of using varistor over other dielectric granules in an air gap for surge protection is identified and discussed.

36 MATERIALS SCIENCE↗

Report on High Energy Arcing Fault Experiments: Experimental Results from Low-Voltage Switchgear Enclosures

This report documents an experimental program designed to investigate High Energy Arcing Fault (HEAF) phenomena for low-voltage metal enclosed switchgear containing aluminum conductors. This report covers full-scale laboratory experiments using representative nuclear power plant (NPP) three-phase electrical equipment. Electrical, thermal, and pressure data were recorded for each experiment and documented in this report. This report covers experiments performed on two low-voltage switchgear units with each unit consisting of two vertical sections. The data collected supports characterization of the low-voltage HEAF hazard and these results will be used to support potential improvements in fire probabilistic risk assessment (PRA) methods. The experiments were performed at KEMA Labs located in Chalfont, Pennsylvania. The experimental design, setup, and execution were completed by staff from the NRC, the National Institute of Standards and Technology (NIST), Sandia National Laboratories (SNL) and KEMA. In addition, representatives from the Electric Power Research Institute (EPRI) observed some of the experimental setup and execution. The HEAF experiments were performed between August 26 and Augsut 29, 2019 on nearidentical Westinghouse Type DS low-voltage metal-enclosed indoor switchgear. The threephase arcing fault was initiated on the aluminum main bus or in select cases on the copper bus stabs near the breaker. These experiments used either nominal 480 volts AC or 600 volts AC. Durations of the experiments ranged from approximately 0.4 s to 8.3 s with fault currents ranging from approximately 9.2 kA to 19.3 kA. Real-time electrical operating conditions, including voltage, current and frequency, were measured during the experiments. Heat fluxes and incident energies were measured with plate thermometers, radiometers, and slug calorimeters at various locations around the electrical enclosures. Environmental measurements of breakdown, conductivity and electromagnetics were also taken. The experiments were documented with normal and high-speed videography, infrared imaging and photography. The results, while limited, indicated the difficulty in maintaining and sustaining low-voltage arcs on aluminum components of sufficient duration and at a single point as observed operating experience.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analyzing Impact of Distributed PV Generation on Integrated Transmission & Distribution System Voltage Stability—A Graph Trace Analysis Based Approach

The use of a Graph Trace Analysis (GTA)-based power flow for analyzing the voltage stability of integrated Transmission and Distribution (T&D) networks is discussed in the context of distributed Photovoltaic (PV) generation. The voltage stability of lines and the load carrying capability of buses is analyzed at various PV penetration levels. It is shown that as the PV generation levels increase, an increase in the steady state voltage stability of the system is observed. Moreover, within certain regions of stability margin changes, changes in voltage stability margins of transmission lines are shown to be linearly related to changes in the loading of the lines. Two case studies are presented, where one case study involves a model with eight voltage levels and 784,000 nodes. In one case study, a voltage-stability heat map is used to demonstrate the identification of weak lines and buses.

14 SOLAR ENERGY↗

High voltage design guide for airborne equipment

The report supplies the theoretical background and design techniques needed by an engineer who is designing electrical insulation for high-voltage high-power components, equipment, and systems on aircraft. A literature survey and abundant bibliography identify references that provide further data on the subjects of partial discharges, corona, field theory and plotting, voids and processes for applying insulation. Both gaseous and solid insulations are treated. Cryogenic and liquid design notes are included. Tests and test equipment for high voltage insulation and equipment are defined. Requirements of test plans and procedures for high-voltage high-power equipment are identified and illustrated by examples. Suggestions for high-voltage specifications are provided. Very few of the Military and Government specifications deal with system voltages above 10kv, thus most aircraft high-voltage specifications will have to be derived from the power industry specifications and standards produced by ASTM, IEEE, and NEMA.

W G Dunbar↗

Factors affecting the open-circuit voltage and electrode kinetics of some iron/titanium redox flow cells

Performance of the iron-titanium redox flow cell was studied as a function of acid concentration. Anion permeable membranes separated the compartments. Electrodes were graphite cloth. Current densities ranged up to 25 mA/square centimeter. Open-circuit and load voltages decreased as the acidity was increased on the iron side as predicted. On the titanium side, open-circuit voltages decreased as the acidity was increased in agreement with theory, but load voltages increased due to decreased polarization with increasing acidity. High acidity on the titanium side coupled with low acidity on the iron side gives the best load voltage, but such cells show voltage losses as they are repeatedly cycled. Analyses show that the bulk of the voltage losses are due to diffusion of acid through the membrane.

Reid, M. A.↗