Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vitrification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Temperature Effect of Cesium Exchange onto Crystalline Silicotitanate in AP-107 and AP-105 Hanford Tank Wastes and Two Simulants

Washington River Protection Solutions, LLC (WRPS) is charged with the development of the Tank Side Cesium Removal (TSCR) system to process Hanford tank waste supernates in preparation for vitrification. In addition to a filtration step, TSCR will remove cesium (Cs) using ion exchange columns filled with crystalline silicotitanate (CST) ion exchange media. CST is produced by Honeywell UOP, LLC. The documented safety analysis (DSA) developed for the TSCR system limits a single column loading to 141,600 Ci 137 Cs. Given a 137 Cs isotopic mass fraction of 20% and the planned CST bed size of 596 L (157.5 gal) in a TSCR column, this equates to 0.10 mmole Cs per g CST (Cs distribution coefficient, K d , 1400 mL/g). Factors that influence Cs uptake by CST include (but are not limited to) (1) CST production (lot-to-lot variations), (2) contact temperature, (3) contact duration, (4) competitors in the tank waste feed, (5) anionic composition of the tank waste feed, and (6) the 137 Cs isotopic mass fraction (differs slightly among tank wastes and decreases with time).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reduced Temperature Cesium Removal from AP-107 Using Crystalline Silicotitanate

The Tank Side Cesium Removal (TSCR) system is currently being constructed to process Hanford tank waste supernates for vitrification. TSCR incorporates a filtration system and cesium (Cs) removal system using columns filled with crystalline silicotitanate (CST) ion exchanger, produced by Honeywell UOP, LLC (product IONSIV™ R9140-B).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Exchange onto Crystalline Silicotitanate from Blended Hanford Tank Wastes

The Tank Side Cesium Removal (TSCR) system was developed to filter and remove cesium (Cs and 137 Cs) from Hanford tank waste supernate in preparation for vitrification. The Cs removal will be conducted with crystalline silicotitanate (CST) ion exchange media. Under the planned waste-processing strategy, the tank waste supernate will be queued for TSCR processing in tank 241-AP-107 (AP-107). Once AP-107 tank waste volume is sufficiently depleted, the waste supernate from tank 241-AP-105 (AP-105, the holding tank before transfer to AP-107) will be transferred to tank AP-107. Supernate from another tank will be transferred to the holding tank, AP-105, for eventual transfer to tank AP-107. These supernate streams will undergo blending in tanks AP-107 and AP-105; the volume blend ratios will be driven by how much the tank waste supernate volumes are depleted before the next tank waste is added. The consequence of tank waste blending on Cs uptake by CST was of interest and was tested via batch contacts; results are reported herein.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of the Sulfur-Saturated Melt Versions of the LAW Phase 5 Glasses

This report provides results from the chemical analyses of a series of sulfur-saturated melt versions of the LAW Phase 5 glasses, a series of simulated nuclear waste glasses designed and fabricated at Pacific Northwest National Laboratory. Results from the chemical analyses of the wash solution resulting from the preparation of these glasses are also included. These data will be used in the development of enhanced property/composition models for waste glass vitrification at Hanford.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Product Consistency Test Results for the LAW ALG Glasses

This report provides the results of the Product Consistency Test leachates from the Low-Activity Waste Algorithm glasses, a series of simulated nuclear waste glasses designed and fabricated at the Pacific Northwest National Laboratory. The series included quenched and canister centerline cooled versions of the glasses. These data will be used in the development, validation, and implementation of enhanced property/composition models for waste glass vitrification at Hanford.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Composition Measurements of the LAW ALG Glasses

This report provides the results from the chemical analyses of glass compositions for the Low-Activity Waste Algorithm study glasses, a series of simulated nuclear waste glasses designed and fabricated at Pacific Northwest National Laboratory. These data will be used in the development, validation, and implementation of enhanced property/composition models for waste glass vitrification at Hanford. Chemical analyses were performed on a representative sample of each of the quenched glasses to allow for comparisons with targeted compositions. The relative differences between the targeted and measured concentrations of SO 3 for most of the glasses were greater than 10%. The relative differences between the targeted and measured concentration of F- was greater than 10% for one glass. The relative differences between the targeted and measured concentration of SnO 2 was greater than 10% for one glass. These results can be used in further characterization of this series of glasses, including the normalization of Product Consistency Test results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Composition Measurements of the Environmental Management Headquarters (EMHQ) Low-Activity Waste (LAW) Glasses

This report provides the results from the chemical analyses of glass compositions for the Environmental Management Headquarters Low-Activity Waste study glasses, a series of simulated nuclear waste glasses fabricated at Pacific Northwest National Laboratory. These data will be used in the development, validation, and implementation of enhanced property/composition models for waste glass vitrification at Hanford. Chemical analyses were performed on a representative sample of each of the quenched glasses to allow for comparisons with targeted compositions. The relative differences between the targeted and measured concentrations of Na 2 O, Li 2 O, and SO 3 for several of the glasses and B 2 O 3 in one of the glasses were greater than 10%. These results can be used in further characterization of this series of glasses, including the normalization of Product Consistency Test results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Product Consistency Test Results for the Environmental Management Headquarters (EMHQ) Low-Activity Waste (LAW) Glasses

This report provides the results of the Product Consistency Test leachates from the Environmental Management Headquarters Low-Activity Waste glasses, a series of simulated nuclear waste glasses designed and fabricated at the Pacific Northwest National Laboratory. The series included quenched versions of the glasses. These data will be used in the development, validation, and implementation of enhanced property/composition models for waste glass vitrification at Hanford. The measured concentrations of the analytes in the test blank samples were below detection limits. The measured concentrations of B, Li, Na, and Si in the Approved Reference Material-1 samples included with the Product Consistency Tests fell within control chart values indicating proper test performance. The measured glass compositions for the study glasses were close to target values: therefore, little difference was seen when evaluating the normalized values using the targeted or measured glass compositions. The $NC_B$, $NC_{Na}$, and $NC_{Si}$ values were less than the Hanford Tank Waste Treatment and Immobilization Plant low-activity waste constraint of 4 g/L for all glasses.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of the Sulfur-Saturated Melt Versions of the EMHQ LAW Glasses

This report provides the results from the chemical analyses of a series of sulfur-saturated melt versions of the EMHQ Low-Activity Waste study glasses, a series of simulated nuclear waste glasses designed and fabricated at Pacific Northwest National Laboratory. These data will be used in the development, validation, and implementation of enhanced property/composition models for waste glass vitrification at Hanford. Chemical analyses were performed on a representative sample of each of the sulfur-saturated melt versions of the glasses to allow for comparisons with targeted compositions, as well as the measured compositions of the quenched glasses. The relative differences between the targeted and measured concentrations of B 2 O 3 , Na 2 O, and SO 3 for several of the glasses and V 2 O 5 and ZrO 2 in two individual glasses were greater than ±10%. The wash solutions contained mainly sodium and sulfur.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

System Configuration Evaluation for Process Settling of Hanford Waste Solid Particles

Direct Feed High-Level Waste (DFHLW) is a potential flowsheet operations approach to initiating high-level waste (HLW) vitrification prior to completion of the Hanford Waste Treatment and Immobilization Plant (WTP) Pretreatment Facility. A settle/decant process has been proposed to concentrate solids prior to delivery to the WTP HLW Facility during DFHLW operations, wherein the solids in a settled layer would be remixed with the supernatant liquid remaining after decanting operations to provide the feed at required solids concentrations. Settling would be used in lieu of purpose-built filtration or other solids separation equipment. Pacific Northwest National Laboratory (PNNL) is providing baseline technical support to the Washington River Protection Solutions (WRPS) Flowsheet Integration group. To support planning for DFHLW, WRPS previously requested that PNNL evaluate the current data set available to predict the time needed for HLW solids to settle and the solids concentration and strength of that settled layer, to identify gaps in the understanding and predictive capability of HLW solids waste settling times, and to provide scoping estimates of the potential settling times. Eight technical gaps were identified for predicting settling times and characteristics of the formed sediment layers. In addition to the data gaps, an overarching observation was made that there is significant variation in behavior of settling rate and settled layer data. The settling time required to concentrate solids via a settle/decant process was determined from the limited data to have a difference of potentially more than a factor of 5,000 in the estimated settling times, varying from 0.2 to 1,060 days for example depending on process vessel depth and final sediment solids concentration. In contrast, successful processes of liquid-forward output streams resulting from in-tank settling and decanting forward liquid have been reported for operations conducted at the Hanford Site. The purpose of this current report is to further support DFHLW planning by evaluating double-shell tank (DST) and alternate vessel equipment and operational configurations to enable optimization of the settle/decant process to concentrate solids. Hanford waste processing behavior specific to liquid feed availability following a slurry transfer in a DST is summarized, including process stream characteristics and process equipment configurations. The performance of DST process equipment configurations is evaluated for possible improvements using computational fluid dynamics (CFD) and simple analytical models. Potential new vessel design(s) specific to enabling effective settle/decant processes, and cursory summary of other separate and inline solids separations processes, are also provided. The CFD results indicated that improvement in outflow solids concentration was promoted by a reduction in the slurry flow rate, angling the distributor nozzles downward, and lifting the transfer pump. The solid-liquid analysis evaluating particle trajectory confirmed that the potential for particle ingestion (in the transfer pump) was decreased with increased radial separation between the inlet and outlet (transfer pump inlet), decreased inlet flow, and decreased liquid density and viscosity for a neutrally buoyant inlet flow. An assessment was also made of the potential for inflow configuration changes to result in the discrete mounding or piling of solids within the tank. Based on the characterization of the settled waste to date, HLW sediments will be unlikely to sustain a substantial angle of repose to facilitate significant variations in the elevation of the settled solids.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of the Sulfur-Saturated Melt Versions of the LAW ALG Glasses

This report provides the results from the chemical analyses of a series of sulfur-saturated melt version of the Low Activity Waste Algorithm study glasses, a series of simulated nuclear waste glasses designed and fabricated at Pacific Northwest National Laboratory. These data will be used in the development, validation, and implementation of enhanced property/composition models for waste glass vitrification at Hanford.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Composition Measurements and Product Consistency Test Results for the EMHQ-LBE-04-B Glass

This report provides the results from the chemical analyses of the glass composition and the Product Consistency Test leachate analyses for the EMHQ-LBE-04-B glass. These data will be used in the development, validation, and implementation of enhanced property/composition models for waste glass vitrification at Hanford.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY2021 ILAW Glass Ion-Exchange Rate Testing

Approximately 54 to 56 million gallons of radioactive mixed waste is currently stored in underground tanks at The United States Department of Energy’s (DOE’s) Hanford site in the State of Washington. The Hanford Tank Waste Treatment and Immobilization Plant (WTP) will provide DOE’s Office of River Protection (ORP) with a means of treating this waste by vitrification for subsequent disposal. The tank waste will be separated into low- and high-activity waste fractions, which will then be vitrified respectively into Immobilized Low Activity Waste (ILAW) and Immobilized High-Level Waste (IHLW) products. The ILAW product will be disposed of in an engineered facility – the Integrated Disposal Facility (IDF) – on the Hanford site, while the IHLW product will be directed to the national deep geological disposal facility for high-level nuclear waste. The ILAW and IHLW products must meet a variety of requirements with respect to protection of the environment before they can be accepted for disposal. To capitalize on the success of the FY19 and FY20 Atkins/VSL test results on six glasses, Washington River Protection Solutions, LLC (WRPS) has contracted with Atkins/VSL to collect IEX data on four more ILAW glasses using PFT, the results of which are the subject of the present report. The work described herein was performed according to a Test Plan that is responsive to the corresponding WRPS scope of work.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY2021 Long-Term PCT of ILAW Glasses

Approximately 54 to 56 million gallons of radioactive waste is currently stored in underground tanks at The United States Department of Energy’s (DOE’s) Hanford site in the State of Washington. The Hanford Tank Waste Treatment and Immobilization Plant (WTP) will provide DOE’s Office of River Protection (ORP) with a means of treating this waste by vitrification for subsequent disposal. The tank waste will be separated into low- and high-activity waste fractions, which will then be vitrified respectively into Immobilized Low Activity Waste (ILAW) and Immobilized High Level Waste (IHLW) products. The ILAW product will be disposed in a near-surface engineered facility – the Integrated Disposal Facility (IDF) – on the Hanford site, while the IHLW product is designed for deep geological disposal in a national facility for high-level nuclear waste. The ILAW and IHLW products must meet a variety of requirements with respect to protection of the environment before they can be accepted for disposal. The objective of the work described in this report is to perform testing, data collection, and analyses for the ILAW glass product for subsequent use in the performance assessment (PA) of the IDF to assess potential environmental risks associated with long-term storage.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reduced Temperature Cesium Removal from AP-101 Using Crystalline Silicotitanate

The Tank Side Cesium Removal (TSCR) system, currently operational under Washington River Protection Solutions LLC (WRPS), sends initial low-activity Hanford waste tank supernate feed to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIV™ R9140-B), was selected as the ion exchange media at TSCR. Laboratory-scale ion exchange processing using TSCR prototypic unit operations continues to contribute toward WRPS establishing accurate process flowsheets for the individual feed campaigns planned for TSCR. This report describes the small-scale ion exchange testing with 14.0 L of diluted and filtered supernate from tank 241-AP-101 (AP-101DF) at 16 °C (62 °F) to demonstrate processing at temperature conditions that are more prototypic of what the TSCR system could experience during colder seasons of the year. Since CST Cs capacity increases with decreasing contact temperature, testing at the lower operating temperature will help to predict the maximum 137 Cs loading onto the CST in the TSCR system. One of the waste acceptance criteria (WAC) for the WTP Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AP-101DF tank waste to meet this criterion, only 0.144% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 694. Testing with AP-101DF matched TSCR prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 62% Cs breakthrough after processing ~1400 BVs of feed; the 50% Cs breakthrough occurred at 1250 BVs. Testing compared to previous AP-107 testing at 16 °C showed ~80 BV increases in volume processed to reach the WAC limit for both lead and lag columns. A similar slope in breakthrough curves for both tests indicates similar kinetic behavior, with variations in feed matrices (Na and Cs concentrations) likely responsible for the deviations in reaching the WAC limit. The Cs effluent from the lag column reached the WAC limit after processing 875 BVs. Anticipating this breakthrough point, the polish column was preemptively installed at 770 BVs. Cs breakthrough from the lag column began at 300 BVs, reaching 5.32×10 0 µCi/mL, or 5.6 % Cs breakthrough, after processing all 1400 BVs of feed. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Composition Measurements of the LAW HPVR Glasses

This report provides the results from the chemical analyses of the glass compositions of the Low-Activity Waste High PCT and VHT Response study glasses, a series of simulated nuclear waste glasses designed and fabricated at Pacific Northwest National Laboratory. These data will be used in the development, validation, and implementation of enhanced property/composition models for waste glass vitrification at Hanford. Chemical analyses were performed on a representative sample of each of the quenched glasses to allow for comparisons with targeted compositions. The relative differences between the targeted and measured concentrations of Cl - , K 2 O, Na 2 O, and ZrO 2 for several of the glasses were greater than 10%. These results can be used in further characterization of this series of glasses, including the normalization of Product Consistency Test results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Composition Measurements of the HLW HAlG Glasses

This report provides the results from the chemical analyses of the glass compositions of the High-Level Waste High-Aluminum Glass study glasses, a series of simulated nuclear waste glasses designed and fabricated at Pacific Northwest National Laboratory. These data will be used in the development, validation, and implementation of enhanced property/composition models for waste glass vitrification at Hanford. Chemical analyses were performed on a representative sample of each of the quenched glasses to allow for comparisons with targeted compositions. The relative differences between the targeted and measured concentrations of Cr 2 O3, P 2 O 5 , and ZrO 2 for several of the glasses were greater than 10%. The relative difference between the targeted and measured concentrations of CaO was greater than 10% for one glass. The relative difference between the targeted and measured concentrations of Li 2 O was greater than 10% for one glass. These results can be used in further characterization of this series of glasses, including the normalization of Product Consistency Test results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of the Sulfur-Saturated Melt Version of the EMHQ-LBE-04-B Glass

This report provides the results from the chemical analyses of the sulfur-saturated melt version of the EMHQ-LBE-04-B glass. These data will be used in the development, validation, and implementation of enhanced property/composition models for waste glass vitrification at Hanford. Chemical analyses were performed on a representative sample of the sulfur-saturated melt version of the glass to allow for comparisons with the targeted composition as well as the measured composition of the quenched glass. The relative differences between the targeted and measured concentration of Na 2 O and SO 3 in the glass were greater than ±10%. The wash solutions contained mainly sodium and sulfate ions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗