Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vertical axis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Pharmacotherapeutics of Intranasal Scopolamine: FDA Regulations and Procedures for Clinical Applications

Space Motion Sickness (SMS) is commonly experienced by astronauts and often requires treatment with medications during the early flight days of a space mission. Bioavailability of oral (PO) SMS medications is often low and highly variable; additionally, physiological changes in a microgravity environment exacerbate variability and decrease bioavailability. These factors prompted NASA to develop an intranasal dosage form of scopolamine (INSCOP) suitable for the treatment of SMS. However, to assure safety and efficacy of treatment in space, NASA physicians prescribe commercially available pharmaceutical products only. Development of a pharmaceutical preparation for clinical use must follow distinct clinical phases of testing, phase I through IV to be exact, before it can be approved by the FDA for approval for clinical use. After a physician sponsored Investigative New Drug (IND) application was approved by the FDA, a phase I clinical trial of INSCOP formulation was completed in normal human subjects and results published. The current project includes three phase II clinical protocols for the assessment of pharmacokinetics and pharmacodynamics (PK/PD), efficacy, and safety of INSCOP. Three clinical protocols that were submitted to FDA to accomplish the project objectives: 1) 002-A, a FDA Phase II dose ranging study with four dose levels between 0.1 and 0.4 mg in 12 subjects to assess PK/PD, 2) 002-B, a phase II clinical efficacy study in eighteen healthy subjects to compare efficacy of 0.2 (low dose) and 0.4 mg (high dose) INSCOP for prophylactic treatment of motion-induces (off-axis vertical rotation) symptoms, and (3) 002-C, a phase II clinical study with twelve subjects to determine bioavailability and pharmacodynamics of two doses (0.2 and 0.4 mg) of INSCOP in simulated microgravity, antiorthostatic bedrest. All regulatory procedures were competed that include certification for Good laboratory Procedures by Theradex , clinical documentation, personnel training, selection of clinical research operations contractor, data capturing and management, and annual reporting of results to FDA were successfully completed. Protocol 002-A was completed and sample and data analysis is currently in progress. Protocol 002-B is currently in progress at Dartmouth Hitchcock Medical Center and Protocol 002-C has been submitted to the FDA and will be implemented at the same contractor site as 002-A. An annual report was filed as required by FDA on the results of Protocol 002-A. Once all the three Phase II protocols are completed, a New Drug Administration application will be filed with FDA for Phase III clinical assessment and approval for marketing of the formulation. A commercial vendor will be identified for this phase. This is critical for making this available for treatment of SMS in astronauts and military personnel on duty. Once approved by FDA, INSCOP can be also used by civilian population for motion sickness associated with recreational travel and other ailments that require treatment with anticholinergic drugs.

Das, H.↗

Neurovestibular and Sensorimotor Studies in Space and Earth Benefits

This review summarizes what has been learned from studies of human neurovestibular system in weightless conditions, including balance and locomotion, gaze control, vestibular-autonomic function and spatial orientation, and gives some examples of the potential Earth benefits of this research. Results show that when astronauts and cosmonauts return from space flight, both the peripheral and central neural processes are physiologically and functionally altered. There are clear distinctions between the virtually immediate adaptive compensations to weightlessness and those that require longer periods of time to adapt. However, little is known to date about the adaptation of sensory-motor functions to long-duration space missions in weightlessness and to the transitions between various reduced gravitational levels, such as on the Moon and Mars. Results from neurovestibular research in space have substantially enhanced our understanding of the mechanisms and characteristics of postural, gaze, and spatial orientation deficits, analogous to clinical cases of labyrinthine-defective function. Also, space neurosciences research has participated in the development and application of significant new technologies, such as video recording and processing of three-dimensional eye movements and posture, hardware for the unencumbered measurement of head and body movement, and procedures for investigating otolith function on Earth. In particular, devices such as centrifugation or off-vertical axis rotation could enhance clinical neurological testing because it provides linear acceleration which specifically stimulates the otolith organs in a frequency range close to natural head and body movement.

Clement, Gilles↗

Exploring and Visualizing A-Train Instrument Data

The succession of US and international satellites that follow each other in close succession, known as the A-Train, affords an opportunity to atmospheric researchers that no single platform could provide: Increasing the number of observations at any given geographic location.. . a more complete "virtual science platform". However, vertically and horizontally, co-registering and regridding datasets from independently developed missions, Aqua, Calipso, Cloudsat, Parasol, and Aura, so that they can be inter-compared can be daunting to some, and may be repeated by many. Scientists will individually spend much of their time and resources acquiring A-Train datasets of interest residing at various locations, developing algorithms to match up and graph datasets along the A-Train track, and search through large amounts of data for areas and/or phenomena of interest. The aggregate amount of effort that can be expended on repeating pre-science tasks could climb into the tens of millions of dollars. The goal of the A-Train Data Depot (ATDD) is to enable free movement of remotely located A-Train data so that they are combined to create a consolidated vertical view of the Earth's Atmosphere along the A-Train tracks. The innovative approach of analyzing and visualizing atmospheric profiles along the platforms track (i.e., time) is accomplished by through the ATDDs Giovanni data analysis and visualization tool. Giovanni brings together data from Aqua (MODIS, AIRS, AMSR-E), Cloudsat (cloud profiling radar) and Calipso (CALIOP, IIR), as well as the Aura (OMI, MLS, HIRDLS, TES) to create a consolidated vertical view of the Earth's Atmosphere along the A-Train tracks. This easy to learn and use exploration tool will allow users to create vertical profiles of any desired A-Train dataset, for any given time of choice. This presentation shows the power of Giovanni by describing and illustrating how this tool facilitates and aids A-Train science and research. A web based display system Giovanni provides users with the capability of creating co-located profile images of temperature and humidity data from the MODIS, MLS and AIRS instruments for a user specified time and spatial area. In addition, Cloud and Aerosol profiles may also be displayed for the Cloudsat and Caliop instruments. The ability to modify horizontal and vertical axis range, data range and dynamic color range is also provided. Two dimensional strip plots of MODIS, AIRS, OM1 and POLDER parameters, co-located along the Cloudsat reference track, can also be plotted along with the Cloudsat cloud profiling data. Center swath pixels for the same parameters can also be shown as line plots overlaying the Cloudsat or Calipso profile images. Images and subsetted data produced in each analysis run may be downloaded. Users truly can explore and discover data specific to their needs prior to ever transferring data to their analysis tools.

Kempler, S.↗

Effects of Frequency and Motion Paradigm on Perception of Tilt and Translation During Periodic Linear Acceleration

Previous studies have demonstrated an effect of frequency on the gain of tilt and translation perception. Results from different motion paradigms are often combined to extend the stimulus frequency range. For example, Off-Vertical Axis Rotation (OVAR) and Variable Radius Centrifugation (VRC) are useful to test low frequencies of linear acceleration at amplitudes that would require impractical sled lengths. The purpose of this study was to compare roll-tilt and lateral translation motion perception in 12 healthy subjects across four paradigms: OVAR, VRC, sled translation and rotation about an earth-horizontal axis. Subjects were oscillated in darkness at six frequencies from 0.01875 to 0.6 Hz (peak acceleration equivalent to 10 deg, less for sled motion below 0.15 Hz). Subjects verbally described the amplitude of perceived tilt and translation, and used a joystick to indicate the direction of motion. Consistent with previous reports, tilt perception gain decreased as a function of stimulus frequency in the motion paradigms without concordant canal tilt cues (OVAR, VRC and Sled). Translation perception gain was negligible at low stimulus frequencies and increased at higher frequencies. There were no significant differences between the phase of tilt and translation, nor did the phase significantly vary across stimulus frequency. There were differences in perception gain across the different paradigms. Paradigms that included actual tilt stimuli had the larger tilt gains, and paradigms that included actual translation stimuli had larger translation gains. In addition, the frequency at which there was a crossover of tilt and translation gains appeared to vary across motion paradigm between 0.15 and 0.3 Hz. Since the linear acceleration in the head lateral plane was equivalent across paradigms, differences in gain may be attributable to the presence of linear accelerations in orthogonal directions and/or cognitive aspects based on the expected motion paths.

Beaton, K. H.↗

Translational Vestibulo-Ocular Reflex and Motion Perception During Interaural Linear Acceleration: Comparison of Different Motion Paradigms

The neural mechanisms to resolve ambiguous tilt-translation motion have been hypothesized to be different for motion perception and eye movements. Previous studies have demonstrated differences in ocular and perceptual responses using a variety of motion paradigms, including Off-Vertical Axis Rotation (OVAR), Variable Radius Centrifugation (VRC), translation along a linear track, and tilt about an Earth-horizontal axis. While the linear acceleration across these motion paradigms is presumably equivalent, there are important differences in semicircular canal cues. The purpose of this study was to compare translation motion perception and horizontal slow phase velocity to quantify consistencies, or lack thereof, across four different motion paradigms. Twelve healthy subjects were exposed to sinusoidal interaural linear acceleration between 0.01 and 0.6 Hz at 1.7 m/s/s (equivalent to 10 tilt) using OVAR, VRC, roll tilt, and lateral translation. During each trial, subjects verbally reported the amount of perceived peak-to-peak lateral translation and indicated the direction of motion with a joystick. Binocular eye movements were recorded using video-oculography. In general, the gain of translation perception (ratio of reported linear displacement to equivalent linear stimulus displacement) increased with stimulus frequency, while the phase did not significantly vary. However, translation perception was more pronounced during both VRC and lateral translation involving actual translation, whereas perceptions were less consistent and more variable during OVAR and roll tilt which did not involve actual translation. For each motion paradigm, horizontal eye movements were negligible at low frequencies and showed phase lead relative to the linear stimulus. At higher frequencies, the gain of the eye movements increased and became more inphase with the acceleration stimulus. While these results are consistent with the hypothesis that the neural computational strategies for motion perception and eye movements differ, they also indicate that the specific motion platform employed can have a significant effect on both the amplitude and phase of each.

Beaton, K. H.↗

3D Reconstruction of a Rotating Erupting Prominence

A bright prominence associated with a coronal mass ejection (CME) was seen erupting from the Sun on 9 April 2008. This prominence was tracked by both the Solar Terrestrial Relations Observatory (STEREO) EUVI and COR1 telescopes, and was seen to rotate about the line of sight as it erupted; therefore, the event has been nicknamed the "Cartwheel CME." The threads of the prominence in the core of the CME quite clearly indicate the structure of a weakly to moderately twisted flux rope throughout the field of view, up to heliocentric heights of 4 solar radii. Although the STEREO separation was 48 deg, it was possible to match some sharp features in the later part of the eruption as seen in the 304 Angstrom line in EUVI and in the H alpha-sensitive bandpass of COR1 by both STEREO Ahead and Behind. These features could then be traced out in three dimensional space, and reprojected into a view in which the eruption is directed towards the observer. The reconstructed view shows that the alignment of the prominence to the vertical axis rotates as it rises up to a leading-edge height of approximately equals 2.5 solar radii, and then remains approximately constant. The alignment at 2.5 solar radii differs by about 115 deg. from the original filament orientation inferred from H alpha and EUV data, and the height profile of the rotation, obtained here for the first time, shows that two thirds of the total rotation is reached within approximately equals 0.5 solar radii above the photosphere. These features are well reproduced by numerical simulations of an unstable moderately twisted flux rope embedded in external flux with a relatively strong shear field component.

Thompson, W. T.↗

Simulator for Testing Spacecraft Separation Devices

A report describes the main features of a system for testing pyrotechnic and mechanical devices used to separate spacecraft and modules of spacecraft during flight. The system includes a spacecraft simulator [also denoted a large mobility base (LMB)] equipped with air thrusters, sensors, and data-acquisition equipment. The spacecraft simulator floats on air bearings over an epoxy-covered concrete floor. This free-flotation arrangement enables simulation of motion in outer space in three degrees of freedom: translation along two orthogonal horizontal axes and rotation about a vertical axis. The system also includes a static stand. In one application, the system was used to test a bolt-retraction system (BRS) intended for separation of the lifting-body and deorbit-propulsion stages of the X- 38 spacecraft. The LMB was connected via the BRS to the static stand, then pyrotechnic devices that actuate the BRS were fired. The separation distance and acceleration were measured. The report cites a document, not yet published at the time of reporting the information for this article, that is said to present additional detailed information.

Johnston, Nick↗

Modification of the Passive Vestibulo-Ocular Reflex During and After Short-Duration Spaceflight

The vestibulo-ocular reflex (VOR) is mediated by integration of canal and otolith inputs to generate compensatory eye movements during head movements. We hypothesized that adaptive change in vestibular processing of gravitoinertial cues would be reflected by plane specific modification of the VOR during passive whole-body rotation during and after spaceflight. Using a repeated measures design, the VOR was assessed in four payload crewmembers in yaw, pitch and roll planes during multiple sessions before, during and after an 8 day orbital mission (STS-42). Rotation was about an earth-vertical axis during ground tests, with the head located off-axis by up to 45cm during pitch and roll rotation (peak acceleration less than 0.2g). The motion profiles included sum-of-sinusoids between 0.02 - 1.39 Hz (yaw), single sinusoids between 0.05-1.25 Hz (yaw and pitch) and velocity steps (yaw, pitch and roll). Eye movements were recorded with both video and electro-oculographic techniques. As expected, VOR gain changes were greater in pitch than in yaw. During pitch rotation, there was a progressive shift in the axis of eye movements during the flight, which was also present during the early post-flight period. This increased horizontal component during pitch, most prevalent at 0.2 Hz, was interpreted as an increase in a translational vergence response elicited during eccentric rotation as subjects imagined a wall fixed target. There was also an increased horizontal component during the eccentric roll step runs performed on flight day 7. These results are consistent with a frequency-dependent increase in otolith-mediated translational VOR responses following adaptation to microgravity. We conclude that the adaptive changes in the VOR are likely to be greatest in the frequency range where there is a cross-over of otolith-mediated tilt and translation responses.

Wood, S. J.↗

Improved Position Sensor for Feedback Control of Levitation

An improved optoelectronic apparatus has been developed to provide the position feedback needed for controlling the levitation subsystem of a containerless-processing system. As explained, the advantage of this apparatus over prior optoelectronic apparatuses that have served this purpose stems from the use of an incandescent lamp, instead of a laser, to illuminate the levitated object. In containerless processing, a small object to be processed is levitated (e.g., by use of a microwave, low-frequency electromagnetic, electrostatic, or acoustic field) so that it is not in contact with the wall of the processing chamber or with any other solid object during processing. In the case of electrostatic or low-frequency electromagnetic levitation, real-time measurement of the displacement of the levitated object from its nominal levitation position along the vertical axis (and, in some cases, along one or two horizontal axes) is needed for feedback control of the levitating field.

Hyers, Robert↗

Algorithm Determines Wind Speed and Direction from Venturi-Sensor Data

An algorithm computes the velocity of wind from the readings of an instrument like the one described in another Tech Brief. To recapitulate: The sensor has no moving parts and is a compact, rugged means of measuring wind vectors having magnitudes of as much as 300 mph (134 m/s). The sensor includes a Venturi gap bounded by a curved upper and a curved lower surface that are axisymmetric with respect to a vertical axis and mirror-symmetric with respect to a horizontal midplane. One of the curved surfaces is instrumented with multiple ports for measuring dynamic pressures. The sensor also incorporates auxiliary sensors for measuring temperature, relative humidity, and static atmospheric pressure. The design and operation of the sensor are based on the concepts of (1) using Bernoulli's equation (which expresses the relationship among variations of speed, density, and pressure along a streamline) to calculate the speed of the wind from differences among the pressure readings at the various ports; and (2) calculating the direction of the wind from the angular positions of ports selected according to comparisons among their pressure readings. The present algorithm performs these calculations.

Zysko, Jan A.↗

Device for Automated Cutting and Transfer of Plant Shoots

A device that enables the automated cutting and transfer of plant shoots is undergoing development for use in the propagation of plants in a nursery or laboratory. At present, it is standard practice for a human technician to use a knife and forceps to cut, separate, and grasp a plant shoot. The great advantage offered by the present device is that its design and operation are simpler than would be those of a device based on the manual cutting/separation/grasping procedure. [The present device should not be confused with a prior device developed for partly the same purpose and described in Compliant Gripper for a Robotic Manipulator (NPO-21104), NASA Tech Briefs, Vol. 27, No. 3 (March 2003), page 59.]. The device (see figure) includes a circular tube sharpened at its open (lower) end and mounted on a robotic manipulator at its closed (upper) end. The robotic manipulator simply pushes the sharpened open end of the tube down onto a bed of plants and rotates a few degrees clockwise then counterclockwise about the vertical axis, causing the tube to cut a cylindrical plug of plant material. Exploiting the natural friction between the tube and plug, the tube retains the plug, without need for a gripping mechanism and control. The robotic manipulator then retracts the tube, translates it to a new location over a plant-growth tray, and inserts the tube part way into the growth medium at this location in the tray. A short burst of compressed air is admitted to the upper end of the tube to eject the plug of plant material and drive it into the growth medium. A prototype has been tested and verified to function substantially as intended. It is projected that in the fully developed robotic plant-propagation system, the robot control system would include a machine- vision subsystem that would automatically guide the robotic manipulator in choosing the positions from which to cut plugs of plant material. Planned further development efforts also include more testing and refinement of the design and operation described above.

Cipra, Raymond↗

3D Reconstruction of a Rotating Erupting Prominence

A bright prominence associated with a coronal mass ejection (CME) was seen erupting from the Sun on 9 April 2008. This prominence was tracked by both the Solar Terrestrial Relations Observatory (STEREO) EUVI and COR1 telescopes, and was seen to rotate about the line of sight a it erupted; therefore, the event has been nicknamed the "Cartwheel CME." The threads of the prominence in the core of the CME quite clearly indicate the structure of a weakly to moderately twisted flux rope throughout the field of view, up to heliocentric heights of 4 solar radii. Although the STEREO separation was 48 deg, it was possible to match some sharp features in the later part of the eruption as seen in the 304 A line in EUVI and in the H-alpha-sensitive bandpass of COR I by both STEREO Ahead and Behind. These features could then be traced out in three-dimensional space, and reprojected into a view in which the eruption is directed toward the observer. The reconstructed view shows that the alignment of the prominence to the vertical axis rotates as it rises up to a leading-edge height of approximately equal to 2.5 solar radii, and then remains approximately constant. The alignment at 2.5 solar radii differs by about 115 deg from the original filament orientation inferred from H-alpha and EUV data, and the height profile of the rotation, obtained here for the first time, shows that two thirds of the total rotation are reached within approximately equal to 0.5 solar radii above the photosphere. These features are well reproduced by numerical simulations of an unstable moderately twisted flux rope embedded in external flux with a relatively strong shear field component.

Thompson, W. T.↗

Estimation of Lower-Body Kinetics from Loading Profile and Kinematics Alone, Without Measured Ground Reaction Forces

Biomechanical models of human motion can estimate kinetic outcomes, such as joint moments, joint forces and muscle forces. Typically, one performs an inverse dynamics (ID) analysis to compute joint moments from joint angles and measured external forces. Sometimes it is impractical to measure ground reaction forces and moments (GRF&M). We devised an empirical method for performing ID analysis of resistance exercises without measured GRF&M. The method solves the multibody dynamics equations of motion with four key assumptions about the GRF&M that reduce the number of unknowns. The assumptions are 1) negligible ground reaction moments, 2) fixed lateral/medial location of the center of pressure (COP), 3) equal fore/aft location of the COP between the feet, and 4) constant angle of the GRF vector relative to the vertical axis in the frontal plane. We used evaluation trials from a spaceflight countermeasure resistance training device to test this approach. Four participants performed squat and deadlift exercises at various loads. We compared results from traditional ID analysis to results without measured GRF&M using our method. We found that joint moment trajectories in the sagittal plane were qualitatively similar in shape between the two methods, and the amount of root mean squared error (RMSE), measured by difference in joint moment impulse, was typically under 10 percent. Non-sagittal joint moment trajectories, which are much lower in overall magnitude, were not qualitatively similar in shape between the two methods. Non-sagittal moments displayed much higher RMSE, with typical values well over 50 percent. These findings were further supported by validation metrics (Sprague and Geers' P and M metrics, Pearson's r correlation coefficient). Based on these findings, we concluded that useful kinetic results are obtained from ID analysis of squat and deadlift exercises, even when GRF&M are not measured, as long as the outcomes of interest lie in the sagittal plane.

computational modeling↗

The Seismic Experiment for Interior Structure (SEIS): Experiment Data Distribution

The six sensors of SEIS (The Seismic Experiment for Interior Structure) [- one of three primary instruments on NASA's Mars Lander Insight] cover a broad range of the seismic bandwidth, from 0.01 hertz to 50 hertz, with possible extension to longer periods. Data are transmitted in the form of three continuous VBB (Very Broad-Band) components at 2 samples per second (sps), an estimation of the short period (SP) energy content from the SP at 1 sps, and a continuous compound VBB/SP vertical axis at 10 sps. The continuous streams are augmented by requested event data with sample rates from 20 to 100 sps. SEIS data products are downlinked from the spacecraft in raw CCSDS (Consultative Committee for Space Data Systems) packets and converted to both the Standard for the Exchange of Earthquake Data (SEED) format files and ASCII tables (GeoCSV) for analysis and archiving. Metadata are available in dataless SEED and StionXML. Time series data (waveforms) are available in miniseed and GeoCSV. Data are distributed according to FDSN (Federation of Digital Seismograph Networks - http://www.fdsn.org) formats and interfaces. Wind, pressure and temperature data from the Auxiliary Payload Sensor Suite (APSS) will also be available in SEED format, and can be used for decorrelation and diagnostic purposes on SEIS.

Pardo, Constanza↗

Dragonfly Preparation for Powered Flight: Lander Separation State Control to Ensure Successful Landing

NASA’s Dragonfly mission, led by The Johns Hopkins University Applied Physics Laboratory, is a relocatable octocopter lander to study Saturn’s largest moon Titan. The scientific goals of the mission include studying Titan’s prebiotic chemistry, geology, and atmosphere. Upon Titan arrival, the lander will enter the atmosphere, descend on a parachute to a ground-relative altitude of about 1000 m before being released, and then fly on internal power down to the surface. To guarantee desirable initial conditions for the lander release, the lander must meet certain angular rate conditions. These conditions include reducing the spin rate about the vertical axis to 4.9 deg/sec, using the rotors as actuators; and releasing with a negative pitch rate (rotating nose down) to ensure a successful transition to powered flight. This is achieved using a release trigger. Achieving these desired rates for lander release is part of the mission phase known as ‘preparation for powered flight’ (PPF). This paper proposes controls and logic to achieve the desired conditions for releasing the lander from the parachute.

Flight Mechanics↗

Dragonfly Preparation for Powered Flight: Lander Separation State Control to Ensure Successful Landing

NASA’s Dragonfly mission, led by The Johns Hopkins University Applied Physics Laboratory, is a relocatable octocopter lander to study Saturn’s largest moon Titan. The scientific goals of the mission include studying Titan’s prebiotic chemistry, geology, and atmosphere. Upon Titan arrival, the lander will enter the atmosphere, descend on a parachute to a ground-relative altitude of about 1000 m before being released, and then fly on internal power down to the surface. To guarantee desirable initial conditions for the lander release, the lander must meet certain angular rate conditions. These conditions include reducing the spin rate about the vertical axis to 4.9 deg/sec, using the rotors as actuators; and releasing with a negative pitch rate (rotating nose down) to ensure a successful transition to powered flight. This is achieved using a release trigger. Achieving these desired rates for lander release is part of the mission phase known as ‘preparation for powered flight’ (PPF). This paper proposes controls and logic to achieve the desired conditions for releasing the lander from the parachute.

Flight Mechanics↗

X-Ray Polarization Measurement of the Gold Standard of Radio-Quiet Active Galactic Nuclei: NGC 1068

Context.NGC 1068 is the most observed radio-quiet active galactic nucleus (AGN) in polarimetry, yet its high-energy polarization has never been probed before due to a lack of dedicated polarimeters.Aims.Using the first X-ray polarimeter sensitive enough to measure the polarization of AGNs, we want to probe the orientation and geometric arrangement of (sub)parsec-scale matter around the X-ray source. Methods. We used the Imaging X-ray Polarimetry Explorer (IXPE) satellite to measure, for the first time, the 2–8 keV polarization of NGC 1068.We pointed IXPE at the target for a net exposure time of 1.15 Ms, in addition to using two Chandra snapshots of∼10 ks each in order to account for the potential impact of several ultraluminous X-ray sources (ULXs) within IXPE’s field of view. Results. We measured a 2–8 keV polarization degree of 12.4%±3.6% and an electric vector polarization angle of 101◦±8◦at a 68% confidence level. If we exclude the spectral region containing bright Fe K lines and other soft X-ray lines where depolarization occurs, the polarization fraction rises to 21.3%±6.7% in the 3.5–6.0 keV band, with a similar polarization angle. The observed polarization angle is found to be perpendicular to the parsec-scale radio jet. Using a combined Chandra and IXPE analysis plus multiwavelength constraints, we estimated that the circum nuclear“torus” may sustain a half-opening angle of 50–55◦(from the vertical axis of the system). Conclusions. Thanks to IXPE, we have measured the X-ray polarization of NGC 1068 and found comparable results, both in terms of the polarization angle orientation with respect to the radio jet and the torus half-opening angle, to the X-ray polarimetric measurement achieved for the other archetypal Compton-thick AGN: the Circinus galaxy. Probing the geometric arrangement of parsec-scale matter in extragalactic objects is now feasible thanks to X-ray polarimetry

active galaxies↗

Volumetric Assessment of UPRITE Exercises From Marker-Based Motion Capture

Lack of volumetric data on full-body movement exercises presents a challenge to ensuring the fit of crew members’ full range of motion on the International Space Station (ISS). The Upright Proprioception Retention via In-flight Training and Evaluation (UPRITE) is a sensorimotor countermeasure device designed for maintaining crew members’ proprioception in a microgravity environment (Figure 1). This work compares differences between data collection-based “high-fidelity” volumes and a “cone volume” with simplified assumptions (95th percentile in stature human standing on UPRITE while tilted and revolved around vertical axis). Objective: To provide the spatial parameters of exercises on the UPRITE such that it is placed on the ISS according to its volumetric demands or that usage is adjusted to fit the available space.

L D Quinto↗