Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transient electrical behavior”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Effect of glass forming additives on low-activity waste feed conversion to glass

A significant effort was invested in the past to develop and refine mathematical models that relate the composition of nuclear waste glasses with their properties, such as viscosity, electrical conductivity, or chemical durability. However, less attention has been paid to the formulation of the melter feed itself, such as the chemical form and the particle size of the glass forming and modifying additives (GFMA), which have a significant effect on the feed-to-glass conversion process during melting. To address this issue, we systematically changed the mineral composition of a simulated low-activity waste melter feed and inspected its melting behavior. When substituting minerals with corresponding oxides and hydroxides, we found that different alumina sources (kyanite, gibbsite, boehmite, or corundum) had the strongest effect on the feed melting process, whereas the sources of Ca, Mg, and Zr had little effect. Further, the x-ray diffraction analysis showed that the alumina sources differ in their dissolution kinetics: early dissolving alumina sources, such as gibbsite (Al(OH) 3 ) and boehmite (AlO(OH)), increase the transient glass-forming melt viscosity at early stages, when gases still evolve, causing extended foaming, whereas alumina sources that dissolve at high temperatures, such as kyanite (Al 2 SiO 5 ) and corundum (Al 2 O 3 ), keep the transient glass-forming melt viscosity low and lead to a faster foam collapse. Using viscosity-composition relationship to estimate the viscosity of transient glass-forming melts in the primary foaming range, we found that the primary foam began to collapse at 360 to 800 Pa s, and fully collapsed between 65 and 260 Pa s. This result agrees with our previous studies, according to which the glass-forming melt viscosity at the cold cap foam bottom ranged from 24 to 85 Pa s.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development and application of two-step uncertainty propagation and sensitivity analysis methodology for fast reactor safety analysis

Uncertainty quantification (UQ) in nuclear reactors for transients is directly linked with safety assessment through the cross-sections uncertainties, provided as a covariance matrix, which are propagated through the reactor system to output of interest pertaining to reactor safety, such as peak temperatures in fuel/clad/coolant. Using a two-step approach, uncertainties are first quantified and propagated from basic input variables (such as reaction cross-sections) to intermediate quantities (such as reactivity feedback coefficients) through lattice level calculations. Uncertainties of intermediate quantities (from the first step) are then propagated through the system transient calculations, in the second step, to obtain uncertainties on reactor safety output parameters of interest. The scope of this work consists of Uncertainty Quantification & Propagation of nuclear data uncertainties that are highly correlated through unprotected transient overpower and unprotected loss of flow to assess their impact on core safety parameters. This two-step approach in the presence of covariance renders the sensitivity analysis very challenging. In fact, usually the sensitivity analysis is restricted to each step, which limits its application since the sensitivities between the system output quantities and the basic input variables are difficult to obtain. Here, in this work, we address this issue by proposing a simple, general methodology to combine the sensitivity indices obtained in each step by assuming the model behavior being linear. For the first step Generalized Perturbation theory based indices are used while in the second step the recently studied Johnson indices. The uncertainty quantification and sensitivity methodologies discussed here are demonstrated on a generic LFR design which is based on the 500 MWth demonstration Lead-cooled fast reactor (DLFR) using oxide fuel, developed by Westinghouse Electric Company (WEC).

42 - ENGINEERING↗

Development and Refinement of Bison Models for Higher Burnup Application

Electric Power Research Institute (EPRI) is an international research organization funded by organizations in the energy and government sectors. The company conducts research to tackle the energy challenges of its member organizations. In support of the U.S. nuclear industry, EPRI and Idaho National Laboratory were awarded a U.S. Department of Energy Technology Commercialization Fund to develop a loss of coolant accident (LOCA) analysis tool. This tool was developed to support burnup extension activities by supplementing the existing capabilities of operators of existing large light-water reactor plants. The tool couples INL developed codes Bison and RELAP5-3D for advanced simulation of LOCA behavior. The project consists of seven major tasks, one of which is the development and refinement of Bison models for higher burnup applications. This task is broken down into six targeted areas of development and refinement including: formation of high burnup structure, fuel fracture and pulverization, transient fission gas release, axial gas communication within a fuel rod, cladding ballooning and burst, and axial fuel relocation. This report summarizes the models for both the fuel and cladding in Bison for high burnup application, identifies the areas of development and refinement necessary to enhance the Bison capabilities to be used in the coupled simulation tool with RELAP5-3D. Integration and regression testing to demonstrate proper implementation of the new features in Bison is highlighted.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Negative signals of photoinduced current transient and thermally stimulated current spectroscopy in GaAs due to negative-U properties of oxygen

Bulk GaAs grown under high oxygen potential shows an intermediate resistivity ({rho}{approx}3x10{sup 3} {omega} cm at room temperature) with an electron activation energy E=0.42 eV. The relevant defect has been identified in literature as off-centered substitutional oxygen with three different charge states. Photoelectrical measurements on such GaAs material exhibit distinctly anomalous signals. Photoinduced current transient spectroscopy (PICTS) shows a signal with a negative sign, whereas thermally stimulated currents (TSCs) are clearly lower than the dark current. By means of a set of coupled differential equations, the carrier exchange between the defect levels and the conduction band is described. Solving these rate equations, the PICTS and TSC curves are modeled. In this way, it could be demonstrated that the anomalous PICTS and TSC signals are caused by the negative-U behavior of the off-center oxygen. This is in agreement with results of infrared spectroscopy.

36 MATERIALS SCIENCE↗

Dynamic Formation of a Transient Jet from Arched Magnetized Laboratory Plasma

Abstract A laboratory plasma experiment was built to explore the eruptive behavior of arched magnetized plasmas with dimensionless parameters relevant to the Sun’s photosphere ( β ≈ 10 −3 , Lundquist number ≈10 4 , plasma radius/ion gyroradius ≈20, ion–neutral collision frequency ≫ion cyclotron frequency). Dynamic formation of a transient plasma jet was observed in the presence of the strapping magnetic field. The eruption leading to the jet is unintuitive because the arched plasma is both kink- and torus-stable. The jet structure erupts within a few Alfvén transit times from the formation of the arched plasma. Extensive measurements of plasma temperature, density, magnetic field, and flows are presented. In its early stages, the jet plasma flows away from the arch with supersonic speeds (Mach 1.5). This high-speed flow persists up to the resistive diffusion time in the arched plasma and is driven by large gradients in the magnetic and thermal pressures near the birthplace of jets. There are two distinct electric current channels within the jet, one consisting of outgoing electrons and another composed of electrons returning to the anode footpoint. Significant current density around the jet is a consequence of the diamagnetic current produced by a large thermal pressure gradient in the jet. Ion–neutral charge-exchange collisions provide an efficient mechanism to produce the cross-field current and control the dynamics of the complex current channels of the jet.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characteristics of plasma properties in an ablative pulsed plasma thruster

Pulsed plasma thrusters are electric space propulsion devices which create a highly transient plasma bulk in a short-time arc discharge that is expelled to create thrust. The transitional character and the dependency on the discharge properties are yet to be elucidated. In this study, optical emission spectroscopy and Mach-Zehnder interferometry are applied to investigate the plasma properties in variation of time, space, and discharge energy. Electron temperature, electron density, and Knudsen numbers are derived for the plasma bulk and discussed. Temperatures were found to be in the order of 1.7 to 3.1 eV, whereas electron densities showed maximum values of more than 10{sup 17} cm{sup -3}. Both values showed strong dependency on the discharge voltage and were typically higher closer to the electrodes. Capacitance and time showed less influence. Knudsen numbers were derived to be in the order of 10{sup -3}-10{sup -2}, thus, indicating a continuum flow behavior in the main plasma bulk.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Testing of Liquid Metal Components for Nuclear Surface Power Systems

The Early Flight Fission Test Facility (EFF-TF) was established by the Marshall Space Flight Center (MSFC) to provide a capability for performing hardware-directed activities to support multiple in-space nuclear reactor concepts by using a non-nuclear test methodology. This includes fabrication and testing at both the module/component level and near prototypic reactor configurations. The EFF-TF is currently supporting an effort to develop an affordable fission surface power (AFSP) system that could be deployed on the Lunar surface. The AFSP system is presently based on a pumped liquid metal-cooled (Sodium-Potassium eutectic, NaK-78) reactor design. This design was derived from the only fission system that the United States has deployed for space operation, the Systems for Nuclear Auxiliary Power (SNAP) 10A reactor, which was launched in 1965. Two prototypical components recently tested at MSFC were a pair of Stirling power conversion units that would be used in a reactor system to convert heat to electricity, and an annular linear induction pump (ALIP) that uses travelling electromagnetic fields to pump the liquid metal coolant through the reactor loop. First ever tests were conducted at MSFC to determine baseline performance of a pair of 1 kW Stirling convertors using NaK as the hot side working fluid. A special test rig was designed and constructed and testing was conducted inside a vacuum chamber at MSFC. This test rig delivered pumped NaK for the hot end temperature to the Stirlings and water as the working fluid on the cold end temperature. These test were conducted through a hot end temperature range between 400 to 550C in increments of 50 C and a cold end temperature range from 30 to 70 C in 20 C increments. Piston amplitudes were varied from 6 to 1 1mm in .5 mm increments. A maximum of 2240 Watts electric was produced at the design point of 550 hot end, 40 C cold end with a piston amplitude of 10.5mm. This power level was reached at a gross thermal efficiency of 28%. A baseline performance map was established for the pair of 1kW Stirling convertors. The performance data will then be used for design modification to the Stirling convertors. The ALIP tested at MSFC has no moving parts and no direct electrical connections to the liquid metal containing components. Pressure is developed by the interaction of the magnetic field produced by the stator and the current which flows as a result of the voltage induced in the liquid metal contained in the pump duct. Flow is controlled by variation of the voltage supplied to the pump windings. Under steady-state conditions, pump performance is measured for flow rates from 0.5-4.3 kg/s. The pressure rise developed by the pump to support these flow rates is roughly 5-65 kPa. The RMS input voltage (phase-to-phase voltage) ranges from 5-120 V, while the frequency can be varied arbitrarily up to 60 Hz. Performance is quantified at different loop temperature levels from 50 C up to 650 C, which is the peak operating temperature of the proposed AFSP reactor. The transient response of the pump is also evaluated to determine its behavior during startup and shut-down procedures.

Polzin, Kurt A.↗

Multi-Physics Simulations of Heat Pipe Micro Reactor

System Analysis Module (SAM) is under development at Argonne National Laboratory as a modern system-level modeling and simulation tool for advanced non-light water reactor safety analyses. It utilizes the object-oriented application framework MOOSE to leverage the modern software environment and advanced numerical methods. The capabilities of SAM are being extended to enable the transient modeling, analysis, and design of various advanced nuclear reactor systems. This report presents the development of new capabilities for modeling the heat pipe type reactor systems. The need for power at remote locations away from a reliable electrical grid is an important niche for nuclear energy. Heat pipe-cooled fast-spectrum nuclear reactors are well suited for these applications. The key feature of the heat pipe reactors is the use of heat pipes for heat removal from the reactor core. The heat pipe makes use of the phase change of the working fluid and transports a large amount of heat from the evaporator to the condensation end with very small temperature drops. In contrast to the traditional nuclear reactor system that makes use of pumped loop for extracting the thermal power, the heat pipe reactors make use of hundreds of heat pipes for removing the thermal power (including the decay heat) passively. This could potentially significantly improve the reliability and safety of the reactor systems. The essential part in the analysis of a heat pipe type reactor is the modeling of heat transport inside the heat pipe. The capability of SAM was extended to enable the modeling of the conventional heat pipe. The full suite of non-LWR codes for confirmatory analysis at NRC is known as the Comprehensive Reactor Analysis Bundle (CRAB). It makes use of existing NRC codes, and integrates them with several codes developed through the DOE-NE’s Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. In this report, the heat pipe micro reactor is simulated using three submodules under CRAB. The MAMMOTH module is used to simulate the reactor kinetics behavior of the micro reactor; the SAM module is used to simulate the heat conduction in the reactor core and heat removal through the heat pipe heat exchangers and Reactor Cavity Cooling System (RCCS); and the MOOSE Tensor Mechanics module is used to simulate the thermal expansion of the reactor cores. The different sub-models are coupled together using MOOSE’s MultiApp system and executed using the BlueCrab application. The new capability has been demonstrated by a steady-state operation analysis, a failure of a single central heat pipe transient analysis, and a loss of heat sink transient analysis. The fully coupled model is shown to work well.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A High-Fidelity Model of the Peach Bottom 2 Turbine-Trip Benchmark Using VERA

This work presents a high-fidelity simulation of the Peach Bottom turbine trip (PBTT) benchmark using the Virtual Environment for Reactor Applications (VERA), a multiphysics reactor modeling tool developed by the U.S. Department of Energy’s Consortium for Advanced Simulation of Light Water Reactors energy innovation hub. The PBTT benchmark, based on a 1977 transient event at the end of cycle 2 in a General Electric Type-4 boiling water reactor (BWR), is a critical test case for validating core physics models with thermal feedback during rapid reactivity events. VERA was employed to perform end-to-end, pin-resolved simulations from conditions at the beginning of cycle 1 through the turbine-trip transient, incorporating detailed neutron transport, fuel depletion, and subchannel thermal hydraulics. The simulation reproduced key benchmark observables with high accuracy: the peak power excursion occurred at 0.75 s, matching the scram time and closely aligning with the benchmark average of 0.742 s; the simulated maximum power spike was approximately 7600 MW, which is within 3% of the benchmark average of 7400 MW; and void-collapse dynamics were consistent with benchmark expectations. Reactivity predictions during cycles 1 and 2 remained within 1500 pcm and 400 pcm of criticality, respectively. These results confirm VERA’s ability to model complex coupled neutronic and thermal hydraulic behavior in a BWR turbine-trip transient, which will support its use in future studies of modeling dryout, fuel performance, and uncertainty quantification for transients of this type.

BWR↗

Analysis of transient electron energy in a micro dielectric barrier discharge for a high performance plasma display panel

We present here analysis of electron energy of a micro dielectric barrier discharge (micro-DBD) for alternating-current plasma display panel (ac-PDP) with Ne/Xe gas mixture by using the optical emission spectroscopy (OES). The OES method is quite useful to evaluate a variety of electron energy in a high pressure DBD ignited in a PDP small cell. Experiment shows that the ratio of Ne emission intensity (I{sub Ne}) relative to Xe emission intensity (I{sub Xe}) drastically decreases with time. This temporal profile is well consistent with dynamic behavior of electron temperature in a micro-DBD, calculated in one-dimensional fluid model. I{sub Ne}/I{sub Xe} also decreases with an increase in Xe gas pressure and a decrease in applied voltage especially in the initial stage of discharge, and these reflect the basic features of electron temperature in a micro-DBD. The influences of plasma parameters such as electron temperature on luminous efficacy are also theoretically analyzed using one-dimensional fluid model. The low electron temperature, which is attained at high Xe gas pressure, realizes the efficient Xe excitation for vacuum ultraviolet radiation. The high Xe-pressure condition also induces the rapid growth of discharge and consequent high plasma density, resulting in high electron heating efficiency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Synthetic Electricity Market Data Generation and HERON Use Case Setup of Advanced Nuclear Reactors Coupled with Thermal Energy Storage Systems

This study evaluates and optimizes advanced nuclear reactors coupled with thermal energy storage (TES) systems in an Integrated Energy System (IES) architecture to enable advanced nuclear power plants (A NPP) to participate in multi-commodity markets, thus enhancing their economic competitiveness. Nuclear-TES coupling scenarios studied herein are designed attenuate the nuclear heat dynamics and defer energy delivery to a later time, enabling the nuclear reactor to continue operating at or near steady-state design conditions as usual while also enabling flexible generation. Three A-NPPs, namely, an advanced light-water reactor (A LWR), a high temperature gas-cooled reactor (HTGR) and a liquid-metal fast reactor (LMFR) were selected as the initial use cases for demonstrating the technoeconomic of thermally balanced energy storage coupling design for thermal power extraction. Each of the reactor technologies were evaluated in two different electricity markets. Stochastic optimization approach was adopted which included the evaluation of price signals from the Pennsylvania-New Jersey-Maryland (PJM) market, and Electric Reliability Council of Texas (ERCOT), using an autoregressive moving average (ARMA) model. Risk Analysis Virtual Environment (RAVEN) tool and its dispatch optimization plugin, the Holistic Energy Resource Optimization Network (HERON), were used to perform dispatch and capacity optimization, using the price data provided by the ARMA models. The results from the Nuclear-TES use cases will be used to design and characterize dynamic integrated system behavior and feedback.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Instrumentation Plan for the OSU High Temperature Test Facility, Revision 4

This instrumentation plan describes the instrumentation requirements and design for the Oregon State University (OSU) High Temperature Test Facility (HTTF). This report outlines HTTF instrumentation design specifications, data acquisition and control system (DACS) design specifications as well as a brief description of the instrumentation to be used in the HTTF. The HTTF is an integral test facility, which has been designed to model the behavior of interest for a Very High Temperature Gas Reactor (VHTR) during the Depressurized Conduction Cooldown (DCC) event. It also has the potential to conduct limited explorations into the progression of the Pressurized Conduction Cooldown (PCC) event and phenomena during normal operations. The facility is scaled 1:4 by height and 1:64 by volume. The maximum core power for the facility is approximately 2.2MW. The core region is of a modular design to allow for both the prismatic block core and the pebble bed core designs to be tested. However, only the prismatic block design is discussed in this report. A correctly scaled integral facility modeling the VHTR that can be used to examine the thermal hydraulic system behavior of the design basis and beyond design basis transients is of significant value. The experimental results obtained in such a program could be used to validate analytical tools and methods being proposed for use with the VHTR. Therefore, it is of importance that the HTTF be instrumented in such a way that the required data is collected to meet its overall goals of phenomena examination and code validation. In addition to the instrumentation used to collect data to achieve the overall goals of the HTTF test program, there is instrumentation in the HTTF, which is primarily used to ensure the safe operation of the test facility. This type of instrumentation shall be termed “Control Instrumentation” and is discussed in this report. This report discusses the DACS, which is a personal computer controlled system that is used to control both the collection and storage of the test matrix and control system data as well as electrical and mechanical operation of the test facility.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Acceleration Modes and Transitions in Pulsed Plasma Accelerators

Pulsed plasma accelerators typically operate by storing energy in a capacitor bank and then discharging this energy through a gas, ionizing and accelerating it through the Lorentz body force. Two plasma accelerator types employing this general scheme have typically been studied: the gas-fed pulsed plasma thruster and the quasi-steady magnetoplasmadynamic (MPD) accelerator. The gas-fed pulsed plasma accelerator is generally represented as a completely transient device discharging in approximately 1-10 microseconds. When the capacitor bank is discharged through the gas, a current sheet forms at the breech of the thruster and propagates forward under a j (current density) by B (magnetic field) body force, entraining propellant it encounters. This process is sometimes referred to as detonation-mode acceleration because the current sheet representation approximates that of a strong shock propagating through the gas. Acceleration of the initial current sheet ceases when either the current sheet reaches the end of the device and is ejected or when the current in the circuit reverses, striking a new current sheet at the breech and depriving the initial sheet of additional acceleration. In the quasi-steady MPD accelerator, the pulse is lengthened to approximately 1 millisecond or longer and maintained at an approximately constant level during discharge. The time over which the transient phenomena experienced during startup typically occur is short relative to the overall discharge time, which is now long enough for the plasma to assume a relatively steady-state configuration. The ionized gas flows through a stationary current channel in a manner that is sometimes referred to as the deflagration-mode of operation. The plasma experiences electromagnetic acceleration as it flows through the current channel towards the exit of the device. A device that had a short pulse length but appeared to operate in a plasma acceleration regime different from the gas-fed pulsed plasma accelerators was developed by Cheng, et al. The Coaxial High ENerGy (CHENG) thruster operated on the 10-microseconds timescales of pulsed plasma thrusters, but claimed high thrust density, high efficiency and low electrode erosion rates, which are more consistent with the deflagration mode of acceleration. Separate work on gas-fed pulsed plasma thrusters (PPTs) by Ziemer, et al. identified two separate regimes of performance. The regime at higher mass bits (termed Mode I in that work) possessed relatively constant thrust efficiency (ratio of jet kinetic energy to input electrical energy) as a function of mass bit. In the second regime at very low mass bits (termed Mode II), the efficiency increased with decreasing mass bit. Work by Poehlmann et al. and by Sitaraman and Raja sought to understand the performance of the CHENG thruster and the Mode I / Mode II performance in PPTs by modeling the acceleration using the Hugoniot Relation, with the detonation and deflagration modes representing two distinct sets of solutions to the relevant conservation laws. These works studied the proposal that, depending upon the values of the various controllable parameters, the accelerator would operate in either the detonation or deflagration mode. In the present work, we propose a variation on the explanation for the differences in performance between the various pulsed plasma accelerators. Instead of treating the accelerator as if it were only operating in one mode or the other during a pulse, we model the initial stage of the discharge in all cases as an accelerating current sheet (detonation mode). If the current sheet reaches the exit of the accelerator before the discharge is completed, the acceleration mode transitions to the deflagration mode type found in the quasi-steady MPD thrusters. This modeling method is used to demonstrate that standard gas-fed pulsed plasma accelerators, the CHENG thruster, and the quasi-steady MPD accelerator are variations of the same device, with the overall acceleration of the plasma depending upon the behavior of the plasma discharge during initial transient phase and the relative lengths of the detonation and deflagration modes of operation.

Polzin, Kurt A.↗

Avoiding Pitfalls in the Determination of Reliable Electrochemical Kinetics Parameters for the Cu 2+ → Cu 1+ Reduction Reaction in Deep Eutectic Solvents

Deep eutectic solvents (DES), on account of their low-cost, non-flammability and electrochemical stability, are attracting attention for their potential use in applications such as electrodeposition and energy storage. In these applications, knowledge of the transport and electrochemical kinetics properties of DES is critically important. To date, attempts to measure the kinetics parameters of the Cu 2+ + e ⇌ Cu 1+ reaction in ethaline DES have yielded a cathodic charge transfer coefficient (α) in the range of 0.2–0.3 suggesting an unexpected asymmetric polarization behavior. In the present work, we pursued a comprehensive study of the kinetics and transport properties of the aforementioned reaction. Using steady-state and transient polarization measurements on RDE and microelectrodes combined with diffusion-reaction modeling, we demonstrate that the Cu 2+ /Cu 1+ transition exhibits a charge transfer coefficient in the range of 0.49–0.54 and an exchange current density in the range 1.72–1.88 mA/cm 2 . Recommendations are provided for avoiding pitfalls in kinetics analysis of highly resistive DES electrolytes. These recommendations include the application of accurate $IR_Ω$ correction and the use of electrode configurations where the secondary current distribution is relatively uniform.

25 ENERGY STORAGE↗

Enhanced Large-Signal Stability Method for Grid-Forming Inverters During Current Limiting: Preprint

Grid-forming (GFM) inverters are a promising technology for the widespread integration of renewable energy sources in future power systems. As a key element of GFM inverter control, the primary controller governs the internal reference voltage and angle. During contingencies in the grid---such as faults, voltage drops, or frequency and phase jumps---an inverter can be forced into a current-limiting mode of operation modulating inverter dynamics, and, as a result, it is prone to losing synchronism with the grid. In this paper, we propose a novel GFM primary control method with an additional synchronization term that naturally activates during contingencies to improve the dynamic response. The method allows the inverter to remain synchronized with the grid, which improves the inverter's dynamic behavior both during and after current-limiting grid conditions and enhances grid support, including voltage support using full current capacity. The method is demonstrated for voltage, frequency, and phase jumps both in a single-machine-to-infinite-bus and a network-wide electromagnetic transient simulation of the IEEE 14-bus system with 5 GFM inverters. The simulations provide insights into the proposed synchronization method and confirm the high potential of the method, which robustly secures synchronism under severe contingencies.

current limiting↗

Using Energy Storage-Based Grid Forming Inverters for Operational Reserve in Hybrid Diesel Microgrids

In remote arctic communities, where access to a bulk electrical grid interconnection is not available, the implementation of islanded microgrids has been the most viable way to produce and distribute electricity services to their inhabitants. Historically, these islanded grids have relied primarily on diesel generators or hydropower resources to supply the baseload. However, this practice can result in increased expense due to the high costs associated with fuel transportation and the significant amounts of on-site storage necessary when fuel transportation is unavailable during winter months. In order to mitigate this problem, arctic microgrids have started to transition to a hybrid-source operational mode by incorporating renewable energy sources that are inherently variable in nature, such as wind or solar. Due to their highly stochastic behavior, these hybrid-source islanded microgrids can pose potential issues related to power quality due to introduction of rapid net load fluctuations and inability of diesel generators to respond rapidly. In addition, non-firm stochastic sources can require significant idling diesel generator resources to serve as spinning reserves, which is inefficient and wasteful. This work studies the problems that may arise in the transient dynamics of a real-world hybrid diesel microgrid when subjected to a loss of wind generation. Moreover, this work proposes a transition from a diesel spinning reserve to a battery energy-storage system (BESS) operating reserve scheme. The study of the proposed transition is important in establishing the fundamental implication of transient dynamics and the potential benefits of integrating a BESS as a spinning reserve in terms of stability, frequency nadir, and transient voltage deviation. The methods to investigate and validate the transient dynamics relied on both electromagnetic simulation models of GFMIs and a commercially available GFMI in an experimental power hardware-in-the-loop setup. The simulation results showed that the proposed operating reserve scheme improves the power quality of the system in terms of voltage deviation and frequency nadir when the microgrid is subjected to a loss of wind generation scenario. Depending on the simulation cases, adding a GFMI reduced the frequency nadir between 65.3% and 86.7%. Moreover, the reductions in the voltage deviations improved between 3.6% and 23.0%. From these results it can be concluded that the integration of a GFMI can reduce the frequency nadir in a hybrid diesel microgrid, and in turn, reduce diesel consumption, which improves system reliability while reducing fuel expenses. Furthermore, the novelty of this work relies on the fact that the offline simulation results were validated using a power hardware-in-the-loop platform that incorporated a 100 kVA commercially available GFMI as the device under test.

Hernandez-Alvidrez, Javier↗

Understanding Dynamic Model Validation of a Wind Turbine Generator and a Wind Power Plant

Regional reliability organizations require power plants to validate the dynamic models that represent them to ensure that power systems studies are performed to the best representation of the components installed. In the process of validating a wind power plant (WPP), one must be cognizant of the parameter settings of the wind turbine generators (WTGs) and the operational settings of the WPP. Validating the dynamic model of a WPP is required to be performed periodically. This is because the control parameters of the WTGs and the other supporting components within a WPP may be modified to comply with new grid codes or upgrades to the WTG controller with new capabilities developed by the turbine manufacturers or requested by the plant owners or operators. The diversity within a WPP affects the way we represent it in a model. Diversity within a WPP may be found in the way the WTGs are controlled, the wind resource, the layout of the WPP (electrical diversity), and the type of WTGs used. Each group of WTGs constitutes a significant portion of the output power of the WPP, and their unique and salient behaviors should be represented individually. The objective of this paper is to illustrate the process of dynamic model validations of WTGs and WPPs, the available data recorded that must be screened before it is used for the dynamic validations, and the assumptions made in the dynamic models of the WTG and WPP that must be understood. Without understanding the correct process, the validations may lead to the wrong representations of the WTG and WPP modeled.

17 WIND ENERGY↗

Effect of proton irradiation temperature on persistent photoconductivity in zinc oxide metal-semiconductor-metal ultraviolet photodetectors

The electrical and structural characteristics of 50-nm-thick zinc oxide (ZnO) metal-semiconductor-metal ultraviolet (UV) photodetectors subjected to proton irradiation at different temperatures are reported and compared. The devices were irradiated with 200 keV protons to a fluence of 1016 cm−2. Examination of the x-ray diffraction (XRD) rocking curves indicates a preferred (100) orientation prior to irradiation, with decrease in crystal quality afterward. Additionally, peak shifts in XRD and Raman spectra of the control sample relative to well-known theoretical positions are indicative of tensile strain in the as-deposited ZnO films. Shifts toward theoretical unstrained positions are observed in the irradiated films, which indicates partial relaxation. Raman spectra also indicate increase in oxygen vacancies (VO) and zinc interstitial defects (Zni) compared to the control sample. Additionally, transient photocurrent measurements performed on each sample at different temperatures showed up to 2× increase in photocurrent decay time constants for irradiated samples vs the control. This persistent photoconductive behavior is linked to the activation of electron and hole traps near the surface, and to the desorption and reabsorption of O2 molecules on the ZnO surface under the influence of UV light. Using an Arrhenius model, trap activation energies were extracted and, by comparing with known energies from the literature, the dominant defects contributing to persistent photoconductivity for each irradiation condition were identified. The persistence of differences in photocurrent transients between different samples months after irradiation indicates that the defects introduced by the suppression of thermally activated dynamic annealing processes have a long-term deleterious effect on device performance.

Heuser, Thomas A. (ORCID:0000000225642400)↗