Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tracer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Trace Gases, Meteorological Parameters, and GPS data for TRACER-MAP

This dataset includes trace gas, meteorological, and GPS measurements made on Mobile Air Quality Laboratory 2 (MAQL2) for the TRACER-MAP sampling campaign. Trace gas measurements include nitric oxide (NO), nitrogen dioxide (NO2), reactive nitrogen compounds (NOy), ozone (O3), sulfur dioxide (SO2), and carbon monoxide (CO). All trace gases are in units of ppbv, excluding CO which is in ppmv. The dataset also includes the photolysis rate of NO2 (jNO2), latitude and longitude, wind speed (WS), wind direction (WD), ambient relative humidity (RH), ambient pressure (press), and ambient temperature (temp). Units for trace gases are in parts per billion (ppbv), latitude and longitude are in decimal degrees (dd), jNO2 is in per second (per sec), pressure is in millibar (mbar), relative humidity is in percent, the temperature is in degrees C, wind direction is in degrees, and wind speed is in meters per second. All data is 5 minutes averaged.

54 ENVIRONMENTAL SCIENCES↗

TRACER CLAMPS1 Doppler Lidar Vertical Stare Data

These files contain 24 hour periods of data collected from the CLAMPS1 Halo Streamline Doppler lidar. While not conducting other scans, the lidar directs the beam to zenith, allowing for the measurement of vertical velocity. These data were collected during the TRACER project.

54 ENVIRONMENTAL SCIENCES↗

TRACER CLAMPS2 Doppler Lidar VAD Data

These files contain 24 hour periods of data collected from the CLAMPS2 Halo Streamline XR+ Doppler lidar. The Doppler lidar conducts regular conical scans at a set elevation angle. These data are then passed through a typical VAD algorithm to retrieve horizontal wind speed and direction profiles. These data were collected during the TRACER project.

54 ENVIRONMENTAL SCIENCES↗

TRACER CLAMPS2 Doppler Lidar Vertical Stare Data

These files contain 24 hour periods of data collected from the CLAMPS2 Halo Streamline XR+ Doppler lidar. While not conducting other scans, the lidar directs the beam to zenith, allowing for the measurement of vertical velocity. These data were collected during the TRACER project.

54 ENVIRONMENTAL SCIENCES↗

CPC data from TAMU TRACER campaign in the Houston, TX region from July to September 2022

During TRACER, the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V) was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. Onboard the ROAM-V, aerosol samples are drawn through a shared isokinetic inlet at a flow rate ranging from 3.5 to 7.0 LPM. A portion of this flow is directed through a cyclone impactor (Brechtel, Inc. Model SCC 0.732) and 0.3 LPM is directed to the CPC. To correct the data for particle losses, we used a two-step method. First, the measured SMPS size distributions were used to calculate total particle loss through the inlet for every SMPS scan at a single deployment location. Second, the CPC data was corrected for particle losses using the average of the total losses per scan. This calculation was done separately for each deployment location due to changes in the measured size distributions between locations. Particle loss from diffusion (based on Kesten, 1991 and Gormley, 1949), inertial impaction in 90-degree bends (based on Aerosol Measurement, 2011 and Crane, 1977), and cyclone impactor efficiency (based on Dirgo, 1985) were included in the loss calculation. When the SMPS was not sampling at a location (in the case of an instrument malfunction or operator error), the reported CPC data was corrected with an average of the total losses for the entire campaign at the specified deployment location (e.g., if we needed to correct Galveston data, then the average of all calculated losses at Galveston was taken). These flatline corrections were used for all data on 22/07/13, 22/07/20, 22/07/22, and the data from Galveston on 22/08/09. An additional flatline correction of 14% was applied to all CPC data based on laboratory calibration prior to and after the campaign. In laboratory calibrations, we identified that for the same sample of air the field CPC (GRIMM Model 5.403 CPC) undercounted the total concentration of particles by 14% compared to the ground truth laboratory CPC (TSI Model 3750). This data was collected for ARM Field Campaign AFC07055 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu. Kesten et. al. Calibration of a TSI Model 3025 Ultrafine Condensation Particle Counter. Aerosol Science and Technology, 15:2, 107-111, 1991. Gormley et. al. Diffusion from a Stream Flowing through a Cylindrical Tube. Proceedings of the Royal Irish Academy, Vol 52, 163-169, 1948. Aerosol Measurement: Principles, Techniques, and Applications, Third Edition. John Wiley & Sons, Inc, 2011. Crane et. al. Inertial Deposition of Particles in a Bent Pipe. Journal of Aerosol Science, Vol 8, 161-170, 1977. Dirgo et. al. Cyclone Collection Efficiency: Comparison of Experimental Results with Theoretical Predictions. Aerosol Science and Technology, 4:4, 401-415, 1985.

54 ENVIRONMENTAL SCIENCES↗

CCN data from TAMU TRACER campaign in the Houston TX region from July to September 2022

During TRACER, the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V) was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. Onboard the ROAM-V, aerosol samples are drawn through a shared isokinetic inlet at a flow rate ranging from 3.5 to 7.0 LPM. A portion of this flow is directed through a cyclone impactor (Brechtel, Inc. Model SCC 0.732) and 0.5 LPM is directed to the CCN. To calculate particle losses, we used a two-step method. First, the measured SMPS size distributions were used to calculate particle loss through the inlet during sampling. Second, the corrected SMPS data was used to calculate the average of the total losses per scan down the CCN line. Then, the correction was applied to the CCN data. This calculation was done separately for each deployment location due to changes in the measured size distributions between locations. Particle loss from diffusion (based on Kesten, 1991 and Gormley, 1949), inertial impaction in 90-degree bends (based on Aerosol Measurement, 2011 and Crane, 1977), and cyclone impactor efficiency (based on Dirgo, 1985) were included in the loss calculation. When the SMPS was not sampling at a location (in the case of an instrument malfunction or operator error), the reported CPC data was corrected with an average of the total losses for the entire campaign at the specified deployment location (e.g., if we needed to correct Galveston data, then the average of all calculated losses at Galveston was taken). These flatline corrections were used for all data on 22/07/13, 22/07/20, 22/07/22, and the data from Galveston on 22/08/09. The supersaturation uncertainty is estimated conservatively at +/- 0.03%, where variation in the inlet temperature, pressure, and calibration technique prevents a more accurate measurement. Confidence in the reported supersaturation measurements is based on a pre-campaign calibration (following the methods from our previous work and Deng, 2014 based on Rose, 2008) in addition to inter-comparisons with the DOE for two days (22/08/18 and 22/09/01) where TAMU was co-located with AMF1. The inter-comparisons show good agreement between our instrument and the DOEs instrument on both days at all supersaturations. After the last inter-comparison on 22/09/01, there was no indication of a malfunction by our instrument through the rest of the campaign. Unfortunately, the instrument was dropped during demobilization. A post-campaign calibration was conducted, which showed a substantial departure from the pre-campaign calibration. The drop may have damaged the instrument’s ability to produce the desired supersaturations. Therefore, we do consider the data after 22/09/01 to be correct, but it should be used with caution. The CCN counter sampled for 3 minutes at each supersaturation setpoint (0.2, 0.4, 0.6, 0.8, 1.0, and 1.2%). At the end of a cycle, the instrument was set to 0.01% supersaturation for 5 minutes. The data is comprised of the last 60 seconds of each supersaturation set point (0.2, 0.4, 0.6, 0.8, 1.0, and 1.2%) to ensure the instrument stabilized and was able to reach thermal equilibrium. We removed the data during the periods where there were operational difficulties, setup, or maintenance. This data was collected for ARM Field Campaign AFC07055 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu. Rose et. al. Calibration and Measurement Uncertainties of a Continuous-Flow Cloud Condensation Nuclei Counter (DMT-CCNC): CCN Activation of Ammonium Sulfate and Sodium Chloride Aerosol Particles in Theory and Experiment. Atmos. Chem. Phys., 8, 1153-1179, 2008. Deng et. al. Using Raman Microspectroscopy to Determine Chemical Composition and Mixing State of Airborne Marine Aerosols over the Pacific Ocean. Aerosol Science and Technology, Vol 48, Issue 2, 2014. Kesten et. al. Calibration of a TSI Model 3025 Ultrafine Condensation Particle Counter. Aerosol Science and Technology, 15:2, 107-111, 1991. Gormley et. al. Diffusion from a Stream Flowing through a Cylindrical Tube. Proceedings of the Royal Irish Academy, Vol 52, 163-169, 1948. Aerosol Measurement: Principles, Techniques, and Applications, Third Edition. John Wiley & Sons, Inc, 2011. Crane et. al. Inertial Deposition of Particles in a Bent Pipe. Journal of Aerosol Science, Vol 8, 161-170, 1977. Dirgo et. al. Cyclone Collection Efficiency: Comparison of Experimental Results with Theoretical Predictions. Aerosol Science and Technology, 4:4, 401-415, 1985.

54 ENVIRONMENTAL SCIENCES↗

SMPS data from TAMU TRACER campaign in the Houston TX region from July to September 2022

During TRACER, the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V) was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. Onboard the ROAM-V, aerosol samples are drawn through a shared isokinetic inlet at a flow rate ranging from 3.5 to 7.0 LPM. A portion of this flow, 1.0 LPM, is directed through TSI's 0.071 cm impactor attached to the classifier of the SMPS setup. The SMPS’s DMA and CPC are connected through a 20.3 cm length of 0.48 cm diameter tubing. Measured SMPS size distributions were used to calculate size-dependent particle losses for each SMPS scan. Particle losses from diffusion (based on Kesten, 1991 and Gormley, 1949) and inertial impaction in 90-degree bends (based on Aerosol Measurement, 2011 and Crane, 1977) were included in the loss calculation. This data was collected for ARM Field Campaign AFC07055 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu. Kesten et. al. Calibration of a TSI Model 3025 Ultrafine Condensation Particle Counter. Aerosol Science and Technology, 15:2, 107-111, 1991. Gormley et. al. Diffusion from a Stream Flowing through a Cylindrical Tube. Proceedings of the Royal Irish Academy, Vol 52, 163-169, 1948. Aerosol Measurement: Principles, Techniques, and Applications, Third Edition. John Wiley & Sons, Inc, 2011. Crane et. al. Inertial Deposition of Particles in a Bent Pipe. Journal of Aerosol Science, Vol 8, 161-170, 1977.

54 ENVIRONMENTAL SCIENCES↗

Mini-Micropulse Lidar data from TAMU TRACER campaign in the Houston TX region from July to September 2022

During TRACER, the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V) was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (mini-MPL)), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. The mini-MPL deployed with ROAM-V is a 532 nm elastic and polarization lidar. The mini-MPL outputs normalized relative backscatter (NRB) derived from raw signal after after-pulse, overlap, and dead-time correction calibration. The depolarization ratio is calculated from the co-polarized and cross-polarized NRB (Flynna et al., 2007). The NRB and depolarization ratio data are resampled from the original data at 1-minute intervals. The vertical resolution of the mini-MPL data is 15 meters. The mini-MPL data can be used to determine the boundary layer, cloud top, and cloud bottom height and can be used to retrieve aerosol type and concentration profile. This data was collected for ARM Field Campaign AFC07055 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu . Flynna, C. J., Mendozaa, A., Zhengb, Y., & Mathurb, S. (2007). Novel polarization-sensitive micropulse lidar measurement technique. Optics express, 15(6), 2785-2790.

54 ENVIRONMENTAL SCIENCES↗

TRACER SPARC Doppler Lidar Vertical Stare Data

These files contain 24 hour periods of data collected from the SPARC Halo Streamline XR+ Doppler lidar. While not conducting other scans, the lidar directs the beam to zenith, allowing for the measurement of vertical velocity. These data were collected during the TRACER project.

54 ENVIRONMENTAL SCIENCES↗

TRACER CLAMPS2 MWR TROPoe Retrievals

These files contain 24 hour periods of retrieved thermodynamic profiles derived from observations collected by the CLAMPS2 Atmospheric Emitted Radiance Interferometer (AERI) and microwave radiometer (MWR). The TROPoe algorithm is a python equivalent to the AERIoe algorithm (see Turner and Loehnert, 2014; Turner and Blumberg 2019). These data were collected during the TRACER-CUBIC project. MWR only and combined AERI and MWR retrievals are available. During this deployment the AERI had high noise so AERI only retrievals are unavailable and the combined AERI and MWR retrievals should be used with extreme caution.

54 ENVIRONMENTAL SCIENCES↗

TRACER CLAMPS1 AERI TROPoe Retrievals

These files contain 24 hour periods of retrieved thermodynamic profiles derived from observations collected by the CLAMPS1 Atmospheric Emitted Radiance Interferometer (AERI). The TROPoe algorithm is a python equivalent to the AERIoe algorithm (see Turner and Loehnert 2014; Turner and Blumberg 2019). These data were collected during the TRACER-CUBIC project. Due to issues with the CLAMPS1 microwave radiometer, only retrievals that used AERI data are available.

54 ENVIRONMENTAL SCIENCES↗

TRACER CLAMPS2 AERI_MWR TROPoe Retrievals

These files contain 24 hour periods of retrieved thermodynamic profiles derived from observations collected by the CLAMPS2 Atmospheric Emitted Radiance Interferometer (AERI) and microwave radiometer (MWR). The TROPoe algorithm is a python equivalent to the AERIoe algorithm (see Turner and Loehnert, 2014; Turner and Blumberg 2019). These data were collected during the TRACER-CUBIC project. MWR only and combined AERI and MWR retrievals are available. During this deployment the AERI had high noise so AERI only retrievals are unavailable and the combined AERI and MWR retrievals should be used with extreme caution.

54 ENVIRONMENTAL SCIENCES↗

TRACER SPARC AERI Data

These files contain 24 hour periods of retrieved thermodynamic profiles derived from observations collected by the University of Wisconsin–Madison Space Science and Engineering Center Portable Atmospheric Research Center (SPARC) Atmospheric Emitted Radiance Interferometer (AERI). The TROPoe algorithm is a python equivalent to the AERIoe algorithm (see Turner and Loehnert, 2014; Turner and Blumberg 2019). These data were collected during the TRACER project.

54 ENVIRONMENTAL SCIENCES↗

TRACER SPARC Doppler Lidar VAD Data

These files contain 24 hour periods of data collected from the SPARC Halo Streamline XR Doppler lidar. The Doppler lidar conducts regular conical scans at a set elevation angle. These data are then passed through a typical VAD algorithm to retrieve horizontal wind speed and direction profiles. These data were collected during the TRACER project.

54 ENVIRONMENTAL SCIENCES↗

TRACER-MAP_2022_absorption_coefficient

Absorption coefficient for PM2.5 measured by the Tri-color Absorption Photometer averaged every 2 minutes for July-August 2022. The location of the measurement is indicated by latitude and longitude coordinates; TRACER-MAP included time at the AMF site in La Porte and additional sites around Houston. Three wavelengths are reported: 365, 520 and 640 nm. The AAE is also reported using the three wavelengths. The data is reported as 2 minute averages.

54 ENVIRONMENTAL SCIENCES↗

TRACER UAS CU RAAVEN Flight Data

This dataset includes observations collected using the University of Colorado RAAVEN small Uncrewed Aircraft System (sUAS) during the TRACER Intensive Operations Period. These observations include flights conducted at two primary locations, including an area near the Brazoria National Wildlife Refuge and the University of Houston Coastal Center. Flights were conducted for approximately two weeks per month between June and the end of September, and include two primary flight modes. The first mode is a spiraling profile between the surface and 600 m above ground level, and the second mode includes flight conducted in a series of stepped altitudes between 600 and 20 m above ground level.

54 ENVIRONMENTAL SCIENCES↗

TRACER-Tethersonde VOC data

One objective of TRACER-Tethersonde campaign was to deploy a volatile organic compound (VOC) sampler on the Tethered Balloon System (TBS) to create vertical profiles and characterize VOC composition. Volatile organic compounds (VOCs) are highly reactive precursor species that undergo atmospheric processing to form secondary products, including aerosol. VOC emissions are influenced by many factors that include but are not limited to temperature, time of day, local anthropogenic activities, and local vegetation, which result in large spatiotemporal variability. The vertical distribution of volatile species is crucial for understanding gas-phase processing for particle production but challenging to accomplish using currently available sampling devices. The standalone sampler built during the campaign enabled the execution of robust experimental designs, including sample collection using resin tubes at multiple altitudes on subsequent flights. Following field sampling, resin tubes were transported back to Baylor University for chemical analysis using a Markes International thermal desorption unit coupled with a gas chromatograph-tandem mass spectrometer (Thermo Scientific). The target analyte list includes biogenic and anthropogenic VOCs.

54 ENVIRONMENTAL SCIENCES↗

Particle size distributions from TRACER-MAP

Particle size distributions measured using a custom scanning mobility analyzer (SMPS) and a TSI, Inc. aerodynamic particle sizer (APS). The size distributions measured with the two instruments were merged during data inversion to produce a single distribution spanning a diameter range from approximately 19 nanometers to 15 micrometers. Size-dependent cloud condensation nuclei (CCN) activity measured with a CCN counter operated in parallel to the condensation particle counter in the SMPS are reported separately. The measurements were made from the Baylor University/University of Houston Mobile Air Quality Laboratory (MAQL) between July 5 and August 30, 2022 during the TRACER-MAP project. The trailer moved between five sites in the Houston regions as follows: Aldine: 7/5-7/8, 7/21-7/26, 8/15-8/24 University of Houston: 7/8-7/16, 8/8-8/15 San Jacinto monument: 7/16-7/21 Jones State Forest: 7/26-8/1; 8/24-8/30 AMF site in La Porte: 8/1-8/8

54 ENVIRONMENTAL SCIENCES↗