Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tomographic imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Characterization of a mock up nuclear waste package using energy resolved MeV neutron analysis

Reliable radiographic methods for characterizing nuclear waste packages non-destructively (without the need to open containers) have the potential to significantly contribute to safe handling and future disposal options, particularly for legacy waste of unknown content. Due to required shielding of waste containers and the need to characterize materials consisting of light elements, X-ray methods are not suitable. Here, energy-resolved MeV neutron radiography is demonstrated as a first-of-its-kind application for non-destructive and remote examination of mock up nuclear waste packages from a safe position using time-of-flight techniques enabled by a novel event-mode imaging detector system. Energy-resolved neutron transmission spectra were measured spatially, permitting the detection of analogue materials to actual nuclear waste such as water, melamine, and ion exchange resin within a 2.54 cm wall thickness steel pipe. The results demonstrate the capability to locate the materials through this wall thickness by radiography and tomographic reconstruction, revealing detailed 3D distributions and structural anomalies. The method effectively detects residual water in ion exchange resin, highlighting its sensitivity to moisture content, a crucial parameter for nuclear waste characterization. Monte Carlo simulations are in agreement with the experimental findings, providing a pathway to simulate waste forms more difficult to tackle experimentally. This work paves the way to apply sub-nanosecond intense MeV neutron sources, such as laser-driven neutron sources under development, to nuclear waste characterization.

36 MATERIALS SCIENCE↗

Quantitative near-field water–air spray measurements at elevated pressures by neutron radiography imaging

Extensive experimental research on high-pressure spray has been conducted for decades to deepen our understanding and optimize its use in transportation, aviation, and propulsion applications; however, the near-field and in-nozzle flow characteristics are not fully understood. Dense near-field spray is among the most challenging diagnostic tasks since light is severely scattered and diffused by the liquid droplets and columns. In this work, the near-field spray and in-nozzle flow characteristics of an aeration nozzle at elevated pressures were characterized by neutron radiography imaging at the Oak Ridge National Laboratory High Flux Isotope Reactor. Neutron imaging benefits via strong penetration depths for some metals (i.e., aluminum, lead, and steel) and is sufficiently sensitive to detection of light elements, especially for hydrogen-based molecules, due to the large incoherent scattering cross section of neutrons. Both two-dimensional snapshots of the near-field spray and a three-dimensional tomographic scan of the nozzle geometry and in-nozzle water were obtained. This work provides new quantitative characterization of practical metal nozzle geometry for accurate boundary conditions, internal flow patterns inside the nozzle, and high-pressure spray flows. In conclusion, the findings may be used to improve performance and operating conditions of transportation vehicles and propulsion systems.

42 ENGINEERING↗

The Anatomy of an Unusual Edge-on Protoplanetary Disk. II. Gas Temperature and a Warm Outer Region

We present high-resolution {sup 12}CO and {sup 13}CO 2–1 ALMA observations, as well as optical and near-infrared spectroscopy, of the highly inclined protoplanetary disk around SSTC2D J163131.2–242627. The spectral type we derive for the source is consistent with a 1.2 M {sub ⊙} star inferred from the ALMA observations. Despite its massive circumstellar disk, we find little to no evidence for ongoing accretion on the star. The CO maps reveal a disk that is unusually compact along the vertical direction, consistent with its appearance in scattered light images. The gas disk extends about twice as far away as both the submillimeter continuum and the optical scattered light. CO is detected from two surface layers separated by a midplane region in which CO emission is suppressed, as expected from freeze-out in the cold midplane. We apply a modified version of the tomographically reconstructed distribution method presented by Dutrey et al. to derive the temperature structure of the disk. We find a temperature in the CO-emitting layers and the midplane of ∼33 K and ∼20 K at R < 200 au, respectively. Outside of R > 200 au, the disk’s midplane temperature increases to ∼30 K, with a nearly vertically isothermal profile. The transition in CO temperature coincides with a dramatic reduction in the submicron and submillimeter emission from the disk. We interpret this as interstellar UV radiation providing an additional source of heating to the outer part of the disk.

47 OTHER INSTRUMENTATION↗

Microstructure reconstruction of battery polymer separators by fusing 2D and 3D image data for transport property analysis

A new approach to generate high-fidelity 3D microstructure reconstructions by leveraging resolution and sample volume characteristics from 2D and 3D microscopy methods is presented here. This approach is employed to model the microstructure of a highly orthotropic polypropylene separator used in lithium-ion batteries, which have challenging multi-scale features of fibrils (<100 nm) and lamellae (>100 nm) to resolve in 3D. Phase contrast nano X-ray computed tomographic data are used to reconstruct the lamellae phase, while 2D scanning electron microscopy data are used to characterize sub-100 nm microstructure features such as the thin fibrils that are beyond the effective resolution of X-ray computed tomography. Fibril geometries are reconstructed stochastically based on the 2D higher resolution data, and integrated with the lamellae geometries in 3D space. Transport property analyses are performed to investigate the bias of microstructure models without considering the fibrils. A sensitivity study is also conducted to facilitate understanding of the relationship between microstructure characteristics and transport properties.

25 ENERGY STORAGE↗

Tomographic detection of photon pairs produced from high-energy X-rays for the monitoring of radiotherapy dosing

Measuring the radiation dose reaching a patient’s body is difficult. Here we report a technique for the tomographic reconstruction of the location of photon pairs originating from the annihilation of positron–electron pairs produced by high-energy X-rays travelling through tissue. We used Monte Carlo simulations on pre-recorded data from tissue-mimicking phantoms and from a patient with a brain tumour to show the feasibility of this imaging modality, which we named ‘pair-production tomography’, for the monitoring of radiotherapy dosing. We simulated three image-reconstruction methods, one applicable to a pencil X-ray beam scanning through a region of interest, and two applicable to the excitation of tissue volumes via broad beams (with temporal resolution sufficient to identify coincident photon pairs via filtered back projection, or with higher temporal resolution sufficient for the estimation of a photon’s time-of-flight). In addition to the monitoring of radiotherapy dosing, we show that image contrast resulting from pair-production tomography is highly proportional to the material’s atomic number. The technique may thus also allow for element mapping and for soft-tissue differentiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Photometric redshifts and intrinsic alignments: Degeneracies and biases in the 3 × 2 pt analysis

We present a systematic study of cosmological parameter bias in weak lensing and large-scale structure analyses for upcoming imaging surveys induced by the interplay of intrinsic alignments (IA) and photometric redshift (photo-z) model misspecification error. We first examine the degeneracies between the parameters of the tidal alignment–tidal torquing (TATT) model for IA and of a photo-z model including a mean shift ( Δ z ¯ ) and variance ( σ z ) for each tomographic bin of lenses and sources, under a variety of underlying true IA behaviors. We identify strong degeneracies between: (1) the redshift scaling of the tidal alignment amplitude and the mean shift and variances of source bins, (2) the redshift scaling of the tidal torquing amplitude and the variance of the lowest- z source bin, and (3) the IA source density weighting and the mean shift and variance of several source bins. We then use this information to guide our exploration of the level of cosmological parameter bias which can be induced given incorrect modeling of IA, photo-z, or both. We find that marginalizing over all the parameters of TATT is generally sufficient to preclude cosmological parameter bias in the scenarios we consider. However, this does not necessarily mean that IA and photo-z parameters are themselves unbiased, nor does it mean that the best-fit model is a good fit to the data. We also find scenarios where the inferred parameters produce χ d . o . f . 2 values indicative of a good fit but cosmological parameter bias is significant, particularly when the IA source density weighting parameter is not marginalized over. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Seismic Tomographic Modeling of the Crust and Upper Mantle beneath Israel and the Middle East: Improved Resolution through Optimized Model Parameterization

Accurate regional seismic travel-time (RSTT) predictions rely on regional phases (e.g., Pg, Lg, Pn, Sn ) to account for 3D effects in the crust and upper mantle that are not captured by 1D models traditionally used for real-time location. The RSTT prediction model accounts for regional-scale crust and upper mantle structure globally by incorporating regional seismic phases into its travel-time calculations. Previous versions of the RSTT model have used a constant grid cell size of 1°. To improve the tomographic accuracy of recovering velocity structure at regional scales, we, in this study, perform data-driven grid refinement on the RSTT model down to a 0.125° grid (~14 km) in pursuit of two main goals: (1) to test the limits of RSTT capability and accuracy of determined velocity structure through variable grid refinement and (2) to image smaller structures in Israel and the Middle East and illuminate upper mantle dynamics operating in this complex tectonic area. We investigate the effects of model parameterization as grid cell size decreases and the trade-offs between recovered velocity structures. Our final dataset includes 4751 events and 499 stations that recorded 79,344 Pn and 7489 Pg . The variable grid refinement method allows recovery of finer-scale velocity structures and reduces travel-time residuals in areas with the highest data coverage. At smaller grid cell sizes, longer paths need to be upweighted to stabilize the inversion. Results illuminate tectonic features undefined in coarser grid-size models; in particular, we observe mantle perturbations related to the subduction zone around the Cyprian arc and crustal anomalies near the Dead Sea fault and throughout the Anatolian plate.

58 GEOSCIENCES↗

Seismic tomography of compressional wave velocity and attenuation structure for Makushin Volcano, Alaska

Located in the central portion of the Alaska-Aleutian subduction zone, Makushin Volcano is among the most active volcanoes in the United States and has been classified as a very high threat by the National Volcano Early Warning System based on its eruptive history and proximity to the City of Unalaska and international air routes. In 2015, five standalone seismic stations and three mini seismic arrays of 15 stations each were deployed on Unalaska Island to supplement the Alaska Volcano Observatory permanent seismic network. This temporary array was operational for one year. Taking advantage of the increased azimuthal coverage and the array's increased earthquake detection capability, we developed body-wave Vp and Vp/Vs seismic images of the velocity structure beneath the volcano. Our results show a complex structure with the upper 4 km of the crust. The shallow high-Vp features possibly delineate remnant magma pathways or conduits. Low-Vp regions are found east of the caldera at approximately 4–8 km depth. This is in agreement with previous seismic tomographic work and InSAR-based geodetic models, which had identified this region as a possible long-term source of magma. A three-dimensional compressional wave attenuation model complemented the velocity models. In general, we observe regions of corresponding low P-wave velocity and high attenuation east of the summit caldera between 5 and 7 km depth, supporting the presence of a melt-rich zone. The absolute Vp values (5.5–6.0 km/s) in this region are consistent with the presence of a magma body with a mafic signature. Here, we suggest that a triggering mechanism that involves mafic injections into a more evolved shallow magma chamber is representative of the current magmatic system below the volcano, similarly to what petrological studies have inferred for past eruptions.

58 GEOSCIENCES↗

Neutron sub-micrometre tomography from scattering data

Neutrons are valuable probes for various material samples across many areas of research. Neutron imaging typically has a spatial resolution of larger than 20 µm, whereas neutron scattering is sensitive to smaller features but does not provide a real-space image of the sample. A computed-tomography technique is demonstrated that uses neutron-scattering data to generate an image of a periodic sample with a spatial resolution of ∼300 nm. The achieved resolution is over an order of magnitude smaller than the resolution of other forms of neutron tomography. This method consists of measuring neutron diffraction using a double-crystal diffractometer as a function of sample rotation and then using a phase-retrieval algorithm followed by tomographic reconstruction to generate a map of the sample's scattering-length density. Topological features found in the reconstructions are confirmed with scanning electron micrographs. This technique should be applicable to any sample that generates clear neutron-diffraction patterns, including nanofabricated samples, biological membranes and magnetic materials, such as skyrmion lattices.

nanoscience↗

LoTToR: An Algorithm for Missing-Wedge Correction of the Low-Tilt Tomographic 3D Reconstruction of a Single-Molecule Structure (LoTToR) v1.0

The low-tilt tomographic reconstruction (LoTToR) method is a post-processing method to correct the missing-wedge artifact, which contains a model-free iteration process under a set of constraints in real and reciprocal spaces. A proof of concept is conducted by using the LoTToR on a phantom, i.e., a simulated 3D reconstruction from a low-tilt series of images, including that within a tilt range of ±15°. The method is validated by using both negative-staining (NS) and cryo-electron tomography (cryo-ET) experimental data. A significantly reduced missing-wedge artifact verifies the capability of LoTToR, suggesting a new tool to support the future study of macromolecular dynamics, fluctuation and chemical activity from the viewpoint of single-molecule 3D structure determination. Moreover, the software can be used for hospital computer tomography (CT) to reduce the radiation damage to patients without reducing the CT image quality.

Ren, Gang↗

Fast X-ray Nanotomography with Sub-10 nm Resolution as a Powerful Imaging Tool for Nanotechnology and Energy Storage Applications

In the last decade, transmission X-ray microscopes (TXMs) have come into operation in most of the synchrotrons worldwide. They have proven to be outstanding tools for non-invasive ex and in situ 3D characterization of materials at the nanoscale across varying range of scientific applications. However, their spatial resolution has not improved in many years, while newly developed functional materials and microdevices with enhanced performances exhibit nanostructures always finer. Here, optomechanical breakthroughs leading to fast 3D tomographic acquisitions (85 min) with sub-10 nm spatial resolution, narrowing the gap between X-ray and electron microscopy, are reported. These new achievements are first validated with 3D characterizations of nanolithography objects corresponding to ultrahigh-aspect-ratio hard X-ray zone plates. Then, this powerful technique is used to investigate the morphology and conformality of nanometer-thick film electrodes synthesized by atomic layer deposition and magnetron sputtering deposition methods on 3D silicon scaffolds for electrochemical energy storage applications.

36 MATERIALS SCIENCE↗

w22_laser_radiography - Laser-Based MeV Radiography

This project seeks to develop novel x-ray sources based on high-power short-pulse lasers with unique advantages, including small spot size, flexible configuration, and tailorable spectra. Kinetic plasma simulations using the VPIC particle in cell code will be performed to support the R&D goals of this project. If successful, this effort will allow LANL to deploy flexible, compact x-ray sources for static tomographic radiography and dynamic multi-axis radiography at our firing sites and facilities such as pRad and U1a. The higher resolution, shorter pulse duration, and tunability of our proposed sources will enable new applications in the weapons program and broader scientific community. This effort advances the LANL FY22 Strategic Investment Plan priority of “[r]adiographic tools for dynamic and static imaging with improved spatial and temporal resolution, sensitivity, and dose.”

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of Constrained Gamma Emission Computed Tomography to Evaluate Fission Product Distributions in High-Temperature Materials from a TRISO Fuel Irradiation

An image reconstruction technique was developed to overcome problems with earlier methods of gamma emission computed tomography of graphite rings surrounding the AGR-3/4 TRISO fission product transport experiment. The profiles obtained from the tomography are compared with sampling done via radially resolved destructive sampling techniques. Generally, there is good agreement between profiles measured via destructive sampling of the rings and the tomographic profiles, though at low signal strengths, the tomographic profiles appear elevated.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Tomographic X-ray particle tracking velocimetry

We investigate the feasibility of in-laboratory tomographic X-ray particle tracking velocimetry (TXPTV) and consider creeping flows with nearly density matched flow tracers. Specifically, in these proof-of-concept experiments we examined a Poiseuille flow, flow through porous media and a multiphase flow with a Taylor bubble. For a full 360° computed tomography (CT) scan we show that the specially selected 60 micron tracer particles could be imaged in less than 3 seconds with a signal-to-noise ratio between the tracers and the fluid of 2.5, sufficient to achieve proper volumetric segmentation at each time step. In the pipe flow, continuous Lagrangian particle trajectories were obtained, after which all the standard techniques used for PTV or PIV (taken at visible wave lengths) could also be employed for TXPTV data. And, with TXPTV we can examine flows inaccessible with visible wave lengths due to opaque media or numerous refractive interfaces. In the case of opaque porous media we were able to observe material accumulation and pore clogging, and for flow with Taylor bubble we can trace the particles and hence obtain velocities in the liquid film between the wall and bubble, with thickness of liquid film itself also simultaneously obtained from the volumetric reconstruction after segmentation. While improvements in scan speed are anticipated due to continuing improvements in CT system components, we show that for the flows examined even the presently available CT systems could yield quantitative flow data with the primary limitation being the quality of available flow tracers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Dark Energy Survey Year 3 high-redshift sample: selection, characterization, and analysis of galaxy clustering

ABSTRACT The fiducial cosmological analyses of imaging surveys like DES typically probe the Universe at redshifts z < 1. We present the selection and characterization of high-redshift galaxy samples using DES Year 3 data, and the analysis of their galaxy clustering measurements. In particular, we use galaxies that are fainter than those used in the previous DES Year 3 analyses and a Bayesian redshift scheme to define three tomographic bins with mean redshifts around z ∼ 0.9, 1.2, and 1.5, which extend the redshift coverage of the fiducial DES Year 3 analysis. These samples contain a total of about 9 million galaxies, and their galaxy density is more than 2 times higher than those in the DES Year 3 fiducial case. We characterize the redshift uncertainties of the samples, including the usage of various spectroscopic and high-quality redshift samples, and we develop a machine-learning method to correct for correlations between galaxy density and survey observing conditions. The analysis of galaxy clustering measurements, with a total signal to noise S/N ∼ 70 after scale cuts, yields robust cosmological constraints on a combination of the fraction of matter in the Universe Ωm and the Hubble parameter h, $\Omega _m h = 0.195^{+0.023}_{-0.018}$, and 2–3 per cent measurements of the amplitude of the galaxy clustering signals, probing galaxy bias and the amplitude of matter fluctuations, bσ8. A companion paper (in preparation) will present the cross-correlations of these high-z samples with cosmic microwave background lensing from Planck and South Pole Telescope, and the cosmological analysis of those measurements in combination with the galaxy clustering presented in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional hot-spot x-ray emission tomography from cryogenic deuterium–tritium direct-drive implosions on OMEGA

A three-dimensional model of the hot-spot x-ray emission has been developed and applied to the study of low-mode drive asymmetries in direct-drive inertial confinement fusion implosions on OMEGA with cryogenic deuterium–tritium targets. Here, the steady-state model assumes an optically thin plasma and the data from four x-ray diagnostics along quasi-orthogonal lines of sight are used to obtain a tomographic reconstruction of the hot spot. A quantitative analysis of the hot-spot shape is achieved by projecting the x-ray emission into the diagnostic planes and comparing this projection to the measurements. The model was validated with radiation-hydrodynamic simulations assuming a mode-2 laser illumination perturbation resulting in an elliptically shaped hot spot, which was accurately reconstructed by the model using synthetic x-ray images. This technique was applied to experimental data from implosions in polar-direct-drive illumination geometry with a deliberate laser-drive asymmetry, and the hot-spot emission was reconstructed using spherical-harmonic modes of up to ℓ = 3. A 10% stronger drive on the equator relative to that on the poles resulted in a prolate-shaped hot spot at stagnation with a large negative A 2,0 coefficient of A 2,0 = –0.47 ± 0.03, directly connecting the modal contribution of the hot-spot shape with the modal contribution in laser-drive asymmetry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

3D isotope density measurements by energy-resolved neutron imaging

Abstract Tools for three-dimensional elemental characterization are available on length scales ranging from individual atoms, using electrons as a probe, to micrometers with X-rays. However, for larger volumes up to millimeters or centimeters, quantitative measurements of elemental or isotope densities were hitherto only possible on the surface. Here, a novel quantitative elemental characterization method based on energy-resolved neutron imaging, utilizing the known neutron absorption cross sections with their ‘finger-print’ absorption resonance signatures, is demonstrated. Enabled by a pixilated time-of-flight neutron transmission detector installed at an intense short-pulsed spallation neutron source, for this demonstration 3.25 million state-of-the-art nuclear physics neutron transmission analyses were conducted to derive isotopic densities for five isotopes in 3D in a volume of 0.25 cm 3 . The tomographic reconstruction of the isotope densities provides elemental maps similar to X-ray microprobe maps for any cross section in the probed volume. The bulk isotopic density of a U-20Pu-10Zr-3Np-2Am nuclear transmutation fuel sample was measured, agrees well with mass-spectrometry and is evidence of the accuracy of the method.

36 MATERIALS SCIENCE↗

KELT-25 b and KELT-26 b: A Hot Jupiter and a Substellar Companion Transiting Young A Stars Observed by TESS

We present the discoveries of KELT-25 b (TIC 65412605, TOI-626.01) and KELT-26 b (TIC 160708862, TOI-1337.01), two transiting companions orbiting relatively bright, early A stars. The transit signals were initially detected by the KELT survey and subsequently confirmed by Transiting Exoplanet Survey Satellite (TESS) photometry. KELT-25 b is on a 4.40 day orbit around the V = 9.66 star CD-24 5016 (T{sub eff}=8280{sub -180}{sup +440} K, M&lowast; = 2.18{sub -0.11}{sup +0.12} M{sub ⊙}), while KELT-26 b is on a 3.34 day orbit around the V = 9.95 star HD 134004 (T{sub eff} = 8640{sub -240}{sup +500} K, M&lowast; = 1.93{sub -0.16}{sup +0.14} M{sub ⊙}), which is likely an Am star. We have confirmed the substellar nature of both companions through detailed characterization of each system using ground-based and TESS photometry, radial velocity measurements, Doppler tomography, and high-resolution imaging. For KELT-25, we determine a companion radius of R{sub P} = 1.64{sub -0.043}{sup +0.039} R{sub J} and a 3σ upper limit on the companion’s mass of ~64 M{sub J}. For KELT-26 b, we infer a planetary mass and radius of M{sub P} = 1.41{sub -0.51}{sup +0.43} M{sub J} and R{sub P} = 1.94{sub -0.058}{sup +0.060} R{sub J}. From Doppler tomographic observations, we find KELT-26 b to reside in a highly misaligned orbit. This conclusion is weakly corroborated by a subtle asymmetry in the transit light curve from the TESS data. KELT-25 b appears to be in a well-aligned, prograde orbit, and the system is likely a member of the cluster Theia 449.

79 ASTRONOMY AND ASTROPHYSICS↗