Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “test procedure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Challenges in practical button cell testing for hydrogen production from high temperature electrolysis of water

High temperature electrolysis of water using solid oxide electrochemical cells (SOEC) is a promising technology for hydrogen production with high energy efficiency and may promote decarbonization when coupled with renewable energy sources and excess heat from nuclear reactors. Over the past several decades there have been extensive scientific and engineering studies on cell materials and degradation behaviors that have greatly improved current density, decreased total resistance, and lowered degradation rates. Although the technology is now at a near-commercial level, maintaining consistency in cell testing and minimizing variance in practical testing environments is an often overlooked but crucial topic. To promote high quality data collection, testing procedures and balance of plant component details are extremely important to consider. This work discusses some key factors affecting the reproducibility of practical SOEC testing on the button cell level, namely, current collection layers, cell sealing procedures, the reliability of steam and hydrogen delivery systems, cell testing fixture design, and reduction procedures. To provide a baseline and a level of standardization for the SOEC community, this work also discloses details of the standard operating procedure and techniques adopted for o-SOEC testing at Idaho National Laboratory (INL).

08 HYDROGEN↗

AGC 4 Graphite Specimen Postirradiation Characterization Plan

This characterization plan describes the thermal, physical, and mechanical measurement techniques that will be used to characterize graphite samples being tested in the fourth Advanced Graphite Creep experiment (AGC-4). Instruments, fixtures, and methods are currently in place for both pre and postirradiation material property measurements of bulk density, thermal diffusivity, coefficient of thermal expansion, elastic modulus, and electrical resistivity. Postirradiation testing procedures used to characterize the samples are described and discussed in the plan. Where they exist, American Society for Testing and Materials (ASTM) International testing standards will apply to the tests. Any departure from ASTM International testing standards or the approved laboratory procedures are documented within this characterization plan. Deviations that occur during testing will be documented in data reports.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

BTMS Testing Section

Cell testing is an important part of understanding the performance and life capabilities of stateof- the art energy storage technologies, particularly with respect to the distinct technical and functional requirements posed by the BTMS program. The baseline requirements for BTMS are loosely defined as a 1MWh BTMS system supporting six 350kW DC fast charging stations with no load profile defined. In order to test energy storage components and systems against these requirements, test procedures must be created that begin to address fundamental questions concerning the balance between cell performance and lifetime to minimize BTMS station cost and maximize station life. System usage scenarios are concurrently being developed with testing of baseline cells intended to illustrate their capabilities relative to a broad set of initial system assumptions. The results from these early performance tests and aging procedures will produce both slow and accelerated cycle-life aging information through a mix of empirical observations and modeling.

25 ENERGY STORAGE↗

Load-cell based characterization system for a “Violin-Mode” shadow-sensor in advanced LIGO suspensions

The background to this work was a prototype shadow sensor, which was designed for retro-fitting to an advanced LIGO (Laser Interferometer Gravitational wave Observatory) test-mass/mirror suspension, in which 40 kg test-mass/mirrors are each suspended by four approximately 600 mm long by 0.4 mm diameter fused-silica suspension fibres. The shadow sensor comprised a LED source of Near InfraRed (NIR) radiation and a rectangular silicon photodiode detector, which, together, were to bracket the fibre under test. The aim was to detect transverse Violin-Mode resonances in the suspension fibres. Part of the testing procedure involved tensioning a silica fibre sample and translating it transversely through the illuminating NIR beam, so as to measure the DC responsivity of the detection system to fibre displacement. However, an equally important part of the procedure, reported here, was to keep the fibre under test stationary within the beam, whilst trying to detect low-level AC Violin-Mode resonances excited on the fibre, in order to confirm the primary function of the sensor. Therefore, a tensioning system, incorporating a load-cell readout, was built into the test fibre’s holder. The fibre then was excited by a signal generator, audio power amplifier, and distant loudspeaker, and clear resonances were detected. A theory for the expected fundamental resonant frequency as a function of fibre tension was developed and is reported here, and this theory was found to match closely with the detected resonant frequencies as they varied with tension. Consequently, the resonances seen were identified as being proper Violin-Mode fundamental resonances of the fibre, and the operation of the Violin-Mode detection system was validated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Silicon pinhole strip defects and their impact on ATLAS Inner Tracker HV current measurement

In preparation for the High-Luminsity LHC (HL-LHC) [1], the ATLAS detector will undergo major detector upgrades, including the replacement of the current Inner Detector with the new all-silicon Inner Tracker (ITk) [2]. The ITk consists of a pixel detector close to the beamline surrounded by a large-area strip detector. During detector production, the electrical properties of silicon sensors and readout electronics must be characterized through a series of quality control (QC) and quality assurance tests. These tests ensure any defect is captured at the earliest possible stage. One such defect, callled a pinhole, occurs when the strip implant and the metal readout electrode are shorted through the intermediary dielectric layer. Notably, the introduction of pinholes during module assembly and pinhole effects on completed modules, especially on leakage current measurement circuitry, have never been studied. In this paper, we investigate the effect of such connections on the sensor leakage current measurements of completed modules and introduce new ways to locate pinholed strips. Here, with minor modifications to testing procedures, such defects are shown not to impede module testing or performance.

FOS: Physical sciences↗

Design and Testing of the Address in Real-Time Data Driver Card for the Micromegas Detector of the ATLAS New Small Wheel Upgrade

The Address in Real Time Data Driver Card (ADDC) is designed to transmit the trigger data in the Micro-Mesh Gaseous Structure (Micromegas) detector of the ATLAS New Small Wheel (NSW) upgrade. The Address in Real Time (ART) signals are generated by the front-end ASIC, named VMM chip, to indicate the address of the first above-threshold event. A custom ASIC (ART ASIC) is designed to receive the ART signals from the VMM chip and implement the hit-selection. The processed data from the ART ASIC will be transmitted out of the NSW through the GBTx serializer, the unidirectional Versatile Twin Transmitter (VTTx) and fiber optical links. The ART signal is critical for the ATLAS experiment trigger selection thus the performance and stability of the ADDC is very important. To ensure extensive testing of the ADDC, an FPGA Mezzanine Card (FMC) based testing platform and a special designed firmware/software are developed. We find that this test platform works with the commercial Xilinx VC707 FPGA development kit, independent of the other electronics of the NSW it can test all the functions of the ADDC and its long-term stability. This paper will introduce the design, testing procedure and results of the ADDC and the FMC testing platform.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experience With LCLS-II Cryomodule Testing at Fermilab

The Cryomodule Test Stand (CMTS1) at Fermilab has been engaged with testing 8-cavity 1.3 GHz cryomodules designed and assembled for the LCLS-II project at SLAC National Accelerator Laboratory since 2016. Over these three years twenty cryomodules have been cooled to 2K and power tested in continuous wave mode on a roughly once per month cycle. Test stand layout and testing procedures are presented together with results from the cryomodules tested to date. Lessons learned and future plans will also be shared.

43 PARTICLE ACCELERATORS↗

ISDSN Sensor System Phase One Test Report

This Phase 1 Test Report documents the test activities and results completed for the Idaho National Laboratory (INL) sensor systems that will be deployed in the meso-scale test bed (MSTB) at Florida International University (FIU), as outlined in the ISDSN-MSTB Test Plan. This report captures the sensor system configuration tested; test parameters, testing procedure, any noted changes from the implementation plan, acquired test data sets, and processed results.

58 GEOSCIENCES↗

Design and Testing of a Prototype Beam Absorber for the PXIE MEBT

One of the goals of the PXIE at Fermilab is to demonstrate the capability to form an arbitrary bunch pattern from an initially CW 162.5 MHz H- bunch train coming out of an RFQ. The bunch-by-bunch selection will take place in the 2.1 MeV Medium Energy Beam Transport (MEBT) by directing the undesired bunches onto an absorber that needs to withstand a beam power of up to 21 kW, focused onto a spot with a ~2 mm rms radius. A design was developed to respond to the driving requirements: high surface power density of 17W/mm 2 and resistance to ion-induced surface blistering. A ¼ - size prototype of the absorber was manufactured, and its thermal properties were tested with an electron beam generating a peak power density similar to the one expected during normal operation of the PXIE beam line. The note describes the absorber concept, the prototype, the testing procedure with the electron beam, and the results of testing.

Baffes, Curtis M.↗

PELICAN Design, Test Planning, and Commissioning Results

To support design efforts for the Versatile Test Reactor (VTR) core assemblies, an experimental facility has been designed and constructed at Argonne National Laboratory to match the hydraulic flow conditions within the VTR’s primary heat transport system (PHTS). This facility, the Pressure drop Experimental Loop for Investigations of Core Assemblies in advanced Nuclear reactors, PELICAN, provides the ability to measure pressure drop across a full-scale fuel assembly containing prototypic axial reflectors, fuel, and plena components. The PELICAN facility was designed and built to offer maximum flexibility, allowing testing from short sub-sections all the way to the full-length core fuel assemblies. The report presents the high-level program objectives, a summary of the facility design, instrumentation, and control systems, and the testing procedure. The outcomes from facility characterization efforts and first test matrix results are then presented and then, finally, the conclusion contains a summary of the future work to be performed. This test facility was designed to match the hydraulic conditions of the flowing sodium in the VTR using water as a surrogate fluid. To do so, the water is elevated to a temperature of 110°C where its viscosity matches that of sodium, and with a 50-HP centrifugal pump, is capable of generating full scale flow rates to achieve prototypic Reynolds and Euler number flow conditions. To prevent boiling, the system is maintained at elevated pressure of at least 2.7-3.0 bar (40-44 psig). A set of 15 tests have been used to perform checkout activities in order to commission the device, survey the capabilities of PELICAN, and generate experimental data at isothermal conditions and over a range of flow rates up to 44 kg/s (700 GPM) to produce datasets used in the verification and validation of VTR design and modeling efforts. Initial testing focused on facility characterization, which assessed the operational capabilities of various control systems. The thermal control system was qualified, including the thermal response of the loop to the heat added by self- and auxiliary heaters, the chiller and heat exchanger systems for removing excess heat, and their coupled ability to maintain steady-state isothermal conditions as desired. Additionally, the pressure control system was verified to ensure necessary operating environments that promote pump health and prevent boiling of loop inventory at high temperatures could be met. With these systems in place, the first set of matrix tests have been carried out using orifice plates with inner diameters of 2.25-inches and 2.5-inches. Orifice plate flow behavior is well covered in scientific literature, and the results find good agreement with the measured pressure drop vs flow rate and those of theoretical predictions. This initial testing not only helps to validate the experiment, but it also produces a high quality data set for a geometry that is easily reproducible for simulations. Finally, the report is concluded with a discussion of the work to come and provides a snapshot of the test articles in the experimental pipeline whose designs are being inspired by the current designs from the VTR.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Baseline Graphite Initial Mechanical Test Report

The Next Generation Nuclear Plant (NGNP) Project is tasked with selecting a high temperature gas reactor technology that will be capable of generating electricity and supplying large amounts of process heat. The NGNP is presently being designed as a helium-cooled high temperature gas reactor (HTGR) with a large graphite core. The graphite baseline characterization project is conducting the research and development (R&D) activities deemed necessary to fully qualify nuclear-grade graphite for use in the NGNP reactor. One of the major fundamental objectives of the project is establishing nonirradiated thermomechanical and thermophysical properties by characterizing lot-to-lot and billet-to-billet variations (for probabilistic baseline data needs) through extensive data collection and statistical analysis. The reactor core will be made up of stacks of graphite moderator blocks. In order to gain a more comprehensive understanding of the varying characteristics in a wide range of suitable graphites, any of which can be classified as “nuclear grade,” an experimental program has been initiated to develop an extensive database of the baseline characteristics of numerous candidate graphites. Various factors known to affect the properties of graphite will be investigated, including specimen size, spatial location within a graphite billet, specimen orientation within a billet (either parallel to [P] or transverse to [T] the long axis of the as-produced billet), and billet-to-billet variations within a lot or across different production lots. Because each data point is based on a certain position within a given billet of graphite, particular attention must be paid to the traceability of each specimen and its spatial location and orientation within each billet. The evaluation of these properties is discussed in the Graphite Technology Development Plan (Windes et. al 2007). One of the key components in the evaluation of these graphite types will be mechanical testing of specimens drawn from carefully controlled sections of each billet. This report is confirmation that the test procedures are in place and approved, and that mechanical testing of graphite under the Baseline Graphite Characterization program has commenced.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Environmental Durability Assessment and Development of Subcomponent Test Methods for Advanced Materials in Marine Energy Applications

Marine energy developers are beginning to rely more heavily on advanced composite materials for their load-bearing structures. Understanding how these materials respond and degrade in harsh marine environments is a complex problem. Much research has been performed at smaller laboratory scales to understand the fundamental physical and chemical degradation mechanisms, but little structural testing research has been performed at larger scales to understand how these physical and chemical interactions scale and how they should be accounted for in the design process. The Advanced Materials project is a multilaboratory research collaboration that addresses these issues with the intention of reducing risks and barriers to marine energy developers wanting to adopt advanced composite materials. The National Laboratory of the Rockies has been playing a leading role in developing larger-scale testing infrastructure and test methods to validate complex numerical degradation models and standardize testing procedures to do so. This paper reviews past structural testing activities, how they have grown into current research activities, and how they will continue to evolve to directly address industry needs. This paper covers key research areas - large-scale water absorption and subsequent structural validation testing, qualification of bolted and adhesive connections, and combined submerged fatigue testing at increasing scales. It provides insights into the complex requirements for testing infrastructure and test method development to effectively qualify materials and certify marine energy structures for harsh marine environments. This research program paves the way for better guidance and standardization within the industry when adopting advanced composite materials.

16 TIDAL AND WAVE POWER↗

An automatic input/output test experience of FPGA-based logic controller with I/O stimulator - 282

This paper describes an automatic testing approach instead of a traditional manual test for an FPGA-based Logic Controller (FLC). It mainly describes an automatic testing of FLC using an I/O stimulator with the initiated manual action. The FLC was developed by Doosan Heavy Industry and KAERI in S. Korea. We also developed a test-bed like I/O stimulator for a burning test based on the operational scenario. Signal sources from the I/O stimulator contain an analog input, an analog output, a digital input and a digital output, a programmable power supply, an RS232C serial interface, and a dual port Ethernet interface. LabVIEW Programming was used for the automatic testing. The FLC consists of a general processor module (FPM-01), a complex processor module (FPM-02), analog input modules (FAI-01), analog output modules (FAO-01), digital input modules (FDI-01), digital output modules (FDO-01), a data link module (FDL-01), and a network module (FNW-01). Among these, in this paper, automatic digital I/O testing and automatic analog I/O testing are described. In addition, for the accuracy of the automatic testing, two graphic recorders are used. One is the output results of general processor based testing, and the other is the output results of complex processor based testing. These are different company products. Redundancy recording was found in the test results. The test results were synchronized internally with the existing I/O stimulator and externally with two graphic recorders. Calibrations of all of the equipment were made before the system testing. Before the testing started, a test plan and the test procedure were set up in advance, and we performed test scenario-based automatic functional testing for the FLC as the qualification process. It can be several executed depending on the scenario and conditional parameters of the test. For validation of the accuracy and reliability in our automated test, manual testing was also performed. Manual tests were conducted in two ways. The first one was a manual test using Fluke 754 and Fluke 715. The other one was using embedded manual features of the I/O stimulator. By performing the automatic input and output testing using the I/O stimulator, the time and expense of FLC testing can be reduced significantly compared with a conventional manual test. We rechecked the automatic test results using Fluke754 manually. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wear of Spheroidal Graphite Cast Irons for Tractor Drive Train Components

The study was prompted by a desire to improve the wear resistance of power transmission components in rear axle drives on commercial farm tractors. Reciprocating wear tests were conducted under lubricated and non-lubricated conditions on three spheroidal cast irons which varied in strength and hardness (designated GGG450, GGG600, and GGG700). Hemispherically-tipped steel pins (designed 42CrMoS4/ 41CrS4) were used as the sliders. Except for the test duration, test procedures were similar to those described in ASTM Standard Test Method G133 for linearly-reciprocating sliding. Among the three cast irons tested, the harder and stronger the alloy, the lower was its wear rate. Wear factors were approximately four orders of magnitude lower for experiments lubricated in fresh, fully-formulated lubricating oil. There was a linear relationship between Brinell hardness of the alloys and the negative logarithm of the wear factors that were expressed in (mm3/N-m). Wear of lubricated test pins was not measurable due to the presence of deposits; however under non-lubricated sliding, the ratio of the wear of the flat specimen to that of the pin decreased as the hardness of the flat specimens approached that of the pin specimen.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ENVIRONMENTAL REACTIVITY OF SOLID STATE HYDRIDE MATERIALS: MODELING AND TESTING FOR AIR AND WATER EXPOSURE

To make commercially acceptable condensed phase hydrogen storage systems, it is important to understand quantitatively the risks involved in using these materials. A rigorous set of environmental reactivity tests have been developed based on modified testing procedures codified by the United Nations for the transportation of dangerous goods. Potential hydrogen storage material, 2LiBH4{center_dot}MgH2 and NH3BH3, have been tested using these modified procedures to evaluate the relative risks of these materials coming in contact with the environment in hypothetical accident scenarios. It is apparent that an ignition event will only occur if both a flammable concentration of hydrogen and sufficient thermal energy were available to ignite the hydrogen gas mixture. In order to predict hydride behavior for hypothesized accident scenarios, an idealized finite element model was developed for dispersed hydride from a breached system. Empirical thermodynamic calculations based on precise calorimetric experiments were performed in order to quantify the energy and hydrogen release rates and to quantify the reaction products resulting from water and air exposure. Both thermal and compositional predictions were made with identification of potential ignition event scenarios.

08 HYDROGEN↗

Oxidizer Testing on Alternative Absorbents for Los Alamos National Laboratory - 18656

In the summer of 2016, during glovebox operations in TA-55, cheesecloth, a cellulosic material, was used to clean up a small spill of 9.8 molar nitric acid (oxidizer). Because cellulosic materials and oxidizers are incompatible, this prompted a chemical compatibility evaluation of the waste in TA-55 to determine if this waste was Resource Conservation and Recovery Act (RCRA) ignitable waste (D001) or RCRA reactive waste (D003). After testing and consulting with the Carlsbad Field Office in Carlsbad (CBFO), Los Alamos National Laboratory (LANL) NPI-7 decided to look for alternative absorbents to use in the gloveboxes that would not create an incompatibility issue with an oxidizer. While small spills are infrequent, they do happen and LANL wanted to be proactive and search for a material that would be compatible with an oxidizer. In December 2016, LANL NPI-7 requested LANL-Carlsbad's (LANL-CO) Difficult Waste Team to perform compatibility testing on potential alternative wipes for disposal at the Waste Isolation Pilot Plant (WIPP). The purpose for testing was to meet the Operational Experience Level 3 (OE-3) requirements that states 'any proposed use of organic absorbents or engineered absorbents in combination with potentially oxidizing TRU waste, wet or dry, should be evaluated and approved by the National TRU Program, Carlsbad Field Office' [1]. LANL NPI-7 requested LANL-CO to perform these tests because they were the group that performed all of the oxidizer testing for CBFO for the Basis of Knowledge (BoK) [2]. LANL NPI-7 chose nine fabrics and KMI Zeolite to be tested. The testing in Carlsbad took approximately 2 months to prepare the procedures, test plans and for the procurement of items. The burn rate testing was done in accordance with the requirements discussed in the BoK and approved by the LANL-CO Difficult Waste Team. Each absorbent was tested for 1) capacity limiting tests, 2) verifying the non-oxidizer threshold concentration of the oxidizer and 3) establishing the non-oxidizer concentration based on the experimental results. The effect of rinsing cheesecloth samples that have absorbed an oxidizer was also tested [3]. The burn rate testing provided three potential alternative absorbents (Spilfyter Hazmat Sorbent SM Pads Premium, Kimtech Pure W4 Wipers and Polybenzimidazole (PBI) Staple fiber) that produced a non-oxidizer result as defined by the BoK. Two wipes Spilfyter Hazmat Sorbent SM Pads Premium and Kimtech Pure W4 Wipers were able to absorb the highest concentration of potassium nitrite and still produce a non-oxidizer. TA-55 has used Spilfyter Hazmat Sorbent SM Pads Premium for a number of years in several of the processes and has ordered Kimtech Pure W4 Wipers for use in the facility. PBI fabric passed at 25 wt. % solution. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Life-Cycle Assessment of Energy and Environmental Impacts of LED Lighting Products, Part 3: LED Environmental Testing

This report covers the third part of a larger U.S. Department of Energy (DOE) project to assess the life- cycle environmental and resource impacts associated with the manufacturing, transport, use, and disposal of light-emitting diode (LED) lighting products in relation to incumbent lighting technologies. All three reports are available on the DOE website (www.ssl.energy.gov/tech_reports.html). Part 1: Review of the Life-Cycle Energy Consumption of Incandescent, Compact Fluorescent and LED Lamps; Part 2: LED Manufacturing and Performance; Part 3: LED Environmental Testing. Parts 1 and 2 were published in February and June 2012, respectively. The Part 1 report included a summary of the life-cycle assessment (LCA) process and methodology, provided a literature review of more than 25 existing LCA studies of various lamp types, and performed a meta-analysis comparing LED lamps with incandescent and compact fluorescent lamps (CFLs). Drawing from the Part 1 findings, Part 2 performed a more detailed assessment of the LED manufacturing process and used these findings to provide a comparative LCA taking into consideration a wider range of environmental impacts. Both reports concluded that the life-cycle environmental impact of a given lamp is dominated by the energy used during lamp operation—the upstream generation of electricity drives the total environmental footprint of the product. However, a more detailed understanding of end-of-life disposal considerations for LED products has become increasingly important as their installation base has grown. The Part 3 study (reported herein) was undertaken to augment the LCA findings with chemical analysis of a variety of LED, CFL, and incandescent lamps using standard testing procedures. A total of 22 samples, representing 11 different models, were tested to determine whether any of 17 elements were present at levels exceeding California or Federal regulatory thresholds for hazardous waste. Notably, this type of testing does not provide an indication of product safety during use. Key findings include: • The selected models were generally found to be below thresholds for Federally regulated elements, although volatile mercury in the CFLs is presumed to have escaped detection; • Nearly all of the lamps (regardless of technology) exceeded at least one California threshold— typically for copper, zinc, antimony, or nickel; • The greatest contributors were the metal screw bases, drivers, ballasts, and wires or filaments— internal LED light sources generally did not cause LED lamps to exceed thresholds. This study was exploratory in nature and was not intended to provide a definitive indication of regulatory compliance for any specific lamp model or technology. Further study would be needed to more broadly characterize the various light source technologies; to more accurately and precisely characterize a specific model; or to determine whether product redesign would be appropriate. However, concentrations of regulated elements in LED lamps were found to be comparable to cell phones and other types of electronic devices, which like incandescent lamps and CFLs have also have been shown to exceed the stringent California thresholds for hazardous waste. Although LED lamps offer reduced life-cycle energy and environmental impacts when compared to CFLs and incandescent lamps, recycling will likely gain importance as consumer adoption of this emerging technology continues to increase.

bulb↗

Documentation pckage for the RFID temperature monitoring system (Of Model 9977 packages at NTS).

The technical basis for extending the Model 9977 shipping package periodic maintenance beyond the one-year interval to a maximum of five years is based on the performance of the O-ring seals and the environmental conditions. The DOE Packaging Certification Program (PCP) has tasked Argonne National Laboratory to develop a Radio-Frequency Identification (RFID) temperature monitoring system for use by the facility personnel at DAF/NTS. The RFID temperature monitoring system, depicted in the figure below, consists of the Mk-1 RFId tags, a reader, and a control computer mounted on a mobile platform that can operate as a stand-alone system, or it can be connected to the local IT network. As part of the Conditions of Approval of the CoC, the user must complete the prescribed training to become qualified and be certified for operation of the RFID temperature monitoring system. The training course will be administered by Argonne National Laboratory on behalf of the Headquarters Certifying Official. This is a complete documentation package for the RFID temperature monitoring system of the Model 9977 packagings at NTS. The documentation package will be used for training and certification. The table of contents are: Acceptance Testing Procedure of MK-1 RFID Tags for DOE/EM Nuclear Materials Management Applications; Acceptance Testing Result of MK-1 RFID Tags for DOE/EM Nuclear Materials Management Applications; Performance Test of the Single Bolt Seal Sensor for the Model 9977 Packaging; Calibration of Built-in Thermistors in RFID Tags for Nevada Test Site; Results of Calibration of Built-in Thermistors in RFID Tags; Results of Thermal Calibration of Second Batch of MK-I RFID Tags; Procedure for Installing and Removing MK-1 RFID Tag on Model 9977 Drum; User Guide for RFID Reader and Software for Temperature Monitoring of Model 9977 Drums at NTS; Software Quality Assurance Plan (SQAP) for the ARG-US System; Quality Category for the RFID Temperature Monitoring System; The Documentation Package for the RFID Temperature Monitoring System; Software Test Plan and Results for ARG-US OnSite; Configuration Management Plan (CMP) for the ARG-US System; Requirements Management Plan for the ARG-US System; and Design Management Plan for ARG-US.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗