Mechanics and Cooling of the CMS Phase-II Tracker Barrel

The CMS upgrade for the High-Luminosity LHC (HL-LHC) era will allow for an incredibly high rate of data collection, to be used in the next generation of precision measurements and searches for beyond the standard model physics. A key element of this upgrade is the full replacement of the silicon strip tracker to enable level-1 triggering on track level primitives, produced by pixel-strip (PS) and strip-strip (2S) modules, tiled together to form the new detector. Mechanically supporting and cooling these modules is not trivial, as material budget in the tracker volume is highly constrained, and as the modules accrue radiation damage they risk becoming entirely non-functional if the silicon sensors are not sufficiently cooled. To address this, each region of the tracker has a bespoke solution for housing and cooling their modules, mostly depending on carbon-fiber and carbon-foam structures, with dual phase CO2 cooling. For the most central part of the tracker, the Flat Barrel with PS modules (Flat TBPS) covers the pseudorapidity range out to $|\eta|=0.4$, and the mechanical structures are manufactured, assembled, and tested entirely by Fermilab and UC Davis. This presentation will describe the intense design and testing requirements for these components, and how they will ensure strong performance of the tracker through the HL-LHC era.

Cosby, Christopher [Fermilab]↗

PIP-II SRF Couplers Fabrication Status and Addressing Ceramic Yield Challenges

The PIP-II project requires reliable SRF couplers to deliver high RF power to the cavities. This talk presents the current status of coupler fabrication, including progress on procurement, assembly, and testing. In particular, it focuses on the challenges encountered with ceramic window production, where limited yield has become a concern. Observed issues and inspection results will be discussed, together with the actions taken to improve quality and consistency. The path forward, including ongoing work with vendors and process adjustments, will also be outlined.

Aiazzi, Tommaso [Fermilab] (ORCID:0009000297503407↗

Best Practices in PEC Water Splitting: How to Reliably Measure Solar-to-Hydrogen Efficiency of Photoelectrodes

Photoelectrochemical (PEC) water splitting, which utilizes sunlight and water to produce hydrogen fuel, is potentially one of the most sustainable routes to clean energy. One challenge to success is that, to date, similar materials and devices measured in different labs or by different operators lead to quantitatively different results, due to the lack of accepted standard operating procedures and established protocols for PEC efficiency testing. With the aim of disseminating good practices within the PEC community, we provide a vetted protocol that describes how to prepare integrated components and accurately measure their solar-to-hydrogen (STH) efficiency (η STH ). This protocol provides details on electrode fabrication, η STH test device assembly, light source calibration, hydrogen evolution measurement, and initial material qualification by photocurrent measurements under monochromatic and broadband illumination. Common pitfalls in translating experimental results from any lab to an accurate STH efficiency under an AM1.5G reference spectrum are discussed. A III–V tandem photocathode is used to exemplify the process, though with small modifications, the protocol can be applied to photoanodes as well. Dissemination of PEC best practices will help those approaching the field and provide guidance for comparing the results obtained at different lab sites by different groups.

08 HYDROGEN↗

Reduced Graphene Oxide Aerogels with Functionalization-Mediated Disordered Stacking for Sodium-Ion Batteries

Surface modified reduced graphene oxide (rGO) aerogels were synthesized using the hydrothermal method. Ethylene diamine (EDA) and α-cyclodextrin (CD) were used to functionalize the surface of the graphene oxide layers. The oxygen reduction and surface modification occurred in-situ during the hydrothermal self-assembly process. The chemical functionality and structure of the resulting ethylene diamine modified (rGO-EDA) and cyclodextrin modified (rGO-CD) aerogels as well as of the pristine unmodified rGO aerogel were studied using XPS, SEM, XRD, and SANS techniques. The overall surface composition showed a significant decrease in the oxygen content for all synthesized aerogels. The surface modified aerogels were characterized by a disordered stacking of the assembled rGO layers. The surface functionalities resulted in a broad distribution of the interlayer spacing and introduced structural heterogeneities. Such disordered structures can enable a better adsorption mechanism of the sodium ions. Coin cells based on the synthesized aerogels and sodium metal were assembled and tested at several charge and discharge rates. The correlation between the surface functionality of the rGO, the induced structural heterogeneities due to the disordered stacking, and the electrochemical performance of sodium-ion batteries were investigated. Operando XRD measurements were carried out during the battery cycling to investigate the adsorption or intercalation nature of the sodiation mechanism.

25 ENERGY STORAGE↗

Implementation of an Experimental Setup Based on the Three-Omega Method for Thermal Conductivity Measurements of Molten Salts

Molten salt reactors (MSRs) are one of the most promising next-generation nuclear reactor designs which use molten salts as the fuel and coolant. To design, model, predict, license, and operate MSRs, the behavior of the fuel and coolant must be understood as a function of temperature and irradiation, i.e., burnup. Of particular importance and complexity is the reliable and reproducible measurement of thermal conductivity of molten salts at high temperatures (> 500 °C). Thermal conductivity provides information on the rate at which heat passes through a specified material and is dependent on chemical composition. Currently, in the national laboratory complex, several methods for measuring thermal conductivity on molten salt systems are under development, however, to date, consistent data have not been produced. Typically, thermal conductivity measurements of high-temperature melts have been conducted by using the Transient Hot Wire (THW) method where thermal conductivity is determined by the change in temperature over time at a certain distance from a heating wire. Another time-dependent technique is the laser flash method, commonly used for solid samples. Laser flash requires prior measurements of density and heat capacity to calculate the thermal conductivity of the sample, introducing additional measurement errors. Steady state and time-dependent measurements such as THW and laser flash have errors from convection and ambient temperature fluctuations (heat radiation). In order to produce high fidelity thermal conductivity data, a measurement technique needs to be developed that will reduce the effect of convection at high temperatures by measuring in a very fast time window. In addition, to measure on actinide and irradiated salts the sample size should be small. Therefore, this project aims to develop a frequency-domain technique based on the three-omega (3?) method, previously proven to work on solids, nanofluids and low temperature solar salts (25 to 250 °C). If the 3?-device can be designed with materials that can withstand high temperatures (>500 °C) and can be configured to reduce errors due to convection, then it would prove to be a valuable technique for ensuring thermal conductivity on molten salt systems needed for MSR development. For this proposal, the 3? instrument will be designed, assembled, and tested on non-radioactive salts before being used on actinide bearing salts. In addition, a thermal model will be developed to determine the thermal conductivity of the sample from the measured thermal oscillation of the sensor. Because 3? is a direct method that requires a small volume of sample and works in a very fast time window, it will aid in suppressing the interference due to convection which is ideal when working with high temperature liquid samples.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Inspection Tools for Hanford Tanks and Waste Transport Systems - 20444

Recent integrity issues in the double-shell tanks (DST) at Hanford have motivated the need for developing innovative tools that can provide information regarding the health of the tanks. These issues include the primary linear failure of AY-102 and recent concerns of thinning in the DST secondary liners. Other concerns include erosion or corrosion on transfer lines and processing pipes. In recent years, Florida International University (FIU) has supported DOE-EM by developing tools that can assist in understanding the health of tanks and waste transport system at Hanford. More specifically, FIU has developed a miniature rover that can be deployed through small risers and gain access to refractory slots in the Hanford DSTs. It traverses through the slots on the primary liner upside down via magnets to avoid debris in the slots. Recent modifications include a spring loaded magnetic arm that allows the unit to traverse over large weld seams but does not reduce the overall functionality of the system. The system has also incorporated a control capsule that will sit within the annulus of the tank and improves on issues related to signal and voltage loss over long tether lines. Lastly, the unit is also being augmented with a second module that will include a means to prep the tank surface and obtain a thickness measurement using a dual element ultrasonic sensor. FIU has also developed a 6-inch peristaltic pipe crawler that operates similar to the previous pipe crawlers developed at FIU. This crawler is a marsupial type crawler that will navigate through the 6-inch drain lines, and deploy a small rover at the entrance of the drain slots. This rover will also traverse upside down on the secondary liner and provide information regarding the health of the liner. An initial prototype for the crawler unit has been developed, assembled and tested. The system is pneumatic and consists of three modules - two grippers and one extender. The validation tests are conducted in a mockup of the drain lines and demonstrate the system's ability to navigate through long pipe lengths and elbows. In this paper, a general overview of each of the aforementioned systems is presented along with results from testing and demonstrations that shows the applicability of each system. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Demonstrate and De-Risk an Internally Lined Tank Design for Molten-Salt Thermal Energy Storage Benefitting CSP and Nuclear-Energy Sectors

The LIMOSA project extends the Gen3 CSP "Liquid Pathway" project to evaluate 720 degrees C thermal energy storage based on molten chloride salts. While SETO selected the Particle Pathway for Gen3 demonstration, LIMOSA was created to resolve a major risk factor with molten chloride salts - the design of the salt storage tank. The project team designed and assembled a test system leveraging experience from Oak Ridge National Lab and the Liquid Pathway Phases 1 and 2. The key innovation in the project is development of a graphite-foil barrier to protect insulation from salt intrusion and wetting.

chloride salt↗

THERMAL MODELING OF HANFORD LEAD CANISTER’S HEATER BENCH TESTS

A computational fluid dynamics (CFD) model was built to simulate planned testing of heater assemblies for the Hanford Lead Canister (HLC) project. The HLC is a canister storage system that will contain heaters to simulate the decay heat of nuclear material and provide the canister storage system with environmental conditions equivalent to the operating conditions on a dry storage pad. The HLC will be equipped with long-term data collection and monitoring systems to provide an early warning of corrosion, pitting, cracking, or other signs of canister degradation that might threaten the integrity of the containment boundary over the potentially long term of dry storage. An important part of the HLC development is to confirm the function and ability of the electric heater assemblies that were specially designed to provide heating similar to the decay heat of nuclear material contained within the canister storage system. Heater bench testing is planned for early 2022 in a test configuration that does not include the canister. The goal of the bench testing is to verify that the heaters can replicate the decay heat of a canister with nuclear material and to validate the thermal models, which are critical to understanding the HLC’s thermal environment, including the local air flow within the canister storage system. Testing of the heater assemblies inside the canister system are planned in the future to validate canister level thermal models, and rigorous pre-deployment testing of the complete HLC cask and canister system is intended to be completed before the HLC is deployed in the 2025-2026 timeframe. This study presents the pre-test temperature predictions of the bench testing. A description of the heater assemblies and planned bench testing is presented. The model was developed with the commercial CFD code STAR-CCM+. An uncertainty analysis was run with the CFD model to determine the uncertainty in the temperature predictions and provide a range over which the predicted temperatures are expected to vary. The uncertainty analysis was performed by coupling STAR-CCM+ with the software Dakota, which provides advanced parametric analyses, including quantification of margins and uncertainty with computational models. This work is expected to provide insight into SNF canister behavior.

Suffield, Sarah R.↗

C1Po2D-04: Cryogenic Testing of the First HL-LHC Q1/Q3 Cryo-Assembly at

In early 2023, Fermilab is conducting horizontal cryogenic testing of the first Q1/Q3 Cryo-Assembly for the high-luminosity LHC upgrade (HL-LHC). The Cryo-Assembly was installed on the upgraded Fermilab horizontal test stand previously used for testing the LHC inner triplet quadrupoles. The cryogenic process requirements of this test include controlled cool-down and warm-up with a 100 K maximum temperature differential between the two ends of the cold mass, operation of a 1.3 bar, 1.9 K bath of subcooled superfluid helium during power testing and magnetic measurements, and operation at pressure up to 18 bar with full helium recovery after a quench.

Rabehl, R.↗

Upsampling Monte Carlo Reactor Simulation Tallies in Depleted Sodium-Cooled Fast Reactor Assemblies Using a Convolutional Neural Network

The computational demand of neutron Monte Carlo transport simulations can increase rapidly with the spatial and energy resolution of tallied physical quantities. Convolutional neural networks have been used to increase the resolution of Monte Carlo simulations of light water reactor assemblies while preserving accuracy with negligible additional computational cost. Here, we show that a convolutional neural network can also be used to upsample tally results from Monte Carlo simulations of sodium-cooled fast reactor assemblies, thereby extending the applicability beyond thermal systems. The convolutional neural network model is trained using neutron flux tallies from 300 procedurally generated nuclear reactor assemblies simulated using OpenMC. Validation and test datasets included 16 simulations of procedurally generated assemblies, and a realistic simulation of a European sodium-cooled fast reactor assembly was included in the test dataset. We show the residuals between the high-resolution flux tallies predicted by the neural network and high-resolution Monte Carlo tallies on relative and absolute bases. The network can upsample tallies from simulations of fast reactor assemblies with diverse and heterogeneous materials and geometries by a factor of two in each spatial and energy dimension. The network’s predictions are within the statistical uncertainty of the Monte Carlo tallies in almost all cases. This includes test assemblies for which burnup values and geometric parameters were well outside the ranges of those in assemblies used to train the network.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Production and testing of the powerboard for ATLAS ITk Strip barrel modules

The upgrade of the ATLAS ITk strips detector for HL-LHC will employ a custom PCB (powerboard) for on-module DC-DC conversion, HV switching, and monitoring. Production of about 14100 of such PCBs with high reliability is a big challenge. In this paper we will present the production procedure and quality control (QC) testing system for the powerboards to be installed on ITk Strip barrel modules. During production, about 150 powerboards will be produced every week. Each powerboard will need to pass QC tests before they are assembled to module. The QC tests include thermal cycling between -35 °C and 40 °C, soak test (continuous running of DC-DC converter at high load at 20 °C), and basic functionality and characterization electrical tests of the low voltage (LV), high voltage (HV), and monitoring functions of the powerboard. A custom QC test system is described, which is based on a reusable PCB (active board) with all testing circuits, a one-time powerboard carrier card, and a Z-turn SoC board which hosts and runs the testing program. The production procedure and QC test system has been tested with 400 powerboards during pre-production, and the system has been proven ready for production with the desired testing program, speed, safety, and cost. Performance and typical failures of powerboards observed during the QC test of pre-production powerboards is also presented.

47 OTHER INSTRUMENTATION↗

Cryogenic testing of the first HL-LHC Q1/Q3 cryo-assembly at Fermilab

In early 2023, Fermilab is conducting horizontal cryogenic testing of the first Q1/Q3 cryo-assembly for the high-luminosity LHC upgrade (HL-LHC). The cryo-assembly was installed on the upgraded Fermilab horizontal test stand previously used for testing the LHC inner triplet quadrupoles. The cryogenic process requirements of this test include controlled cool-down and warm-up with a 100 K maximum temperature differential between the two ends of the cold mass, operation of a 1.3 bar, 1.9 K bath of subcooled superfluid helium during power testing and magnetic measurements, and operation at pressure up to 18 bar with full helium recovery after a quench. This paper presents the operational experience gained from this first test.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tank Side Cesium Removal IXC-150 Cask Detonation Report

A set of experiments were conducted at Los Alamos National Laboratory’s firing point 88 to determine the blast pressure and effects of a stoichiometric gas mixture of Hydrogen (H 2 ) and Nitrous Oxide (N 2 O) on the IXC-150 Storage Pad Vent Stack assemblies. The Lab was asked to design, build, and test the vent stack assemblies using a reaction gas volume of 340 in 3 that mimics the Tank Side Cesium Removal (TSCR) Ion Exchange Column (IXC) assembly. The experimental system with vent stack assembly was designed with input from the Washington River Protection Services (WRPS) to ensure an accurate test setup. The tests were conducted at LANL on the newly built filter/gas assembly at the end of April 2021 timeframe, using WRPS supplied vent stack assemblies and internal HEPA filters. The objective of these tests was to observe that the structural integrity of the vent stack assemblies was maintained and determine the resulting blast overpressures at a distance of 16 and 32 inches from the assembly. All work was performed under the LANL Quality Assurance Program (SD330), using a graded application of ASME NQA-1- 2008/NQA-1a-2009. To ensure that all client quality assurance (QA) expectations were addressed, evaluation of the end data needs was performed and the appropriate controls applied for this work.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Degradation Effects at the Porous Transport Layer/Catalyst Layer Interface in Polymer Electrolyte Membrane Water Electrolyzer

The porous transport layer (PTL)/catalyst layer (CL) interface plays a crucial role in the achievement of high performance and efficiency in polymer electrolyte membrane water electrolyzers (PEMWEs). This study investigated the effects of the PTL/CL interface on the degradation of membrane electrode assemblies (MEAs) during a 4000 h test, comparing the MEAs assembled with uncoated and Ir-coated Ti PTLs. Our results show that compared to an uncoated PTL/CL interface, an optimized interface formed when using a platinum group metal (PGM) coating, i.e., an iridium layer at the PTL/CL interface, and reduced the degradation of the MEA. The agglomeration and formation of voids and cracks could be found for both MEAs after the long-term test, but the incorporation of an Ir coating on the PTL did not affect the morphology change or oxidation of IrO x in the catalyst layer. In addition, our studies suggest that the ionomer loss and restructuring of the anodic MEA can also be reduced by Ir coating of the PTL/CL interface. Optimization of the PTL/CL interface improves the performance and durability of a PEMWE.

30 DIRECT ENERGY CONVERSION↗

Conceptual design of the modular detector and readout system for the CMB-S4 survey experiment

We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background – Stage four (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60% of the sky. The fundamental building block of the detector and readout system is a detector module package operated at 100 mK, which is connected to a readout and amplification chain that carries signals out to room temperature. It uses arrays of feedhorn-coupled orthomode transducers (OMT) that collect optical power from the sky onto dc-voltage-biased transition-edge sensor (TES) bolometers. The resulting current signal in the TESs is then amplified by a two-stage cryogenic Superconducting Quantum Interference Device (SQUID) system with a time-division multiplexer to reduce wire count, and matching room-temperature electronics to condition and transmit signals to the data acquisition system. Sensitivity and systematics requirements are being developed for the detector and readout system over wide range of observing bands (20 to 300 GHz) and optical powers to accomplish CMB-S4’s science goals. While the design incorporates the successes of previous generations of CMB instruments, CMB-S4 requires an order of magnitude more detectors than any prior experiment. This requires fabrication of complex superconducting circuits on over 10 m2 of silicon, as well as significant amounts of precision wiring, assembly and cryogenic testing

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Long-term durability test of highly efficient membrane electrode assemblies for anion exchange membrane seawater electrolyzers

Direct seawater electrolysis faces fundamental electrochemical challenges, such as suppression of chlorine adsorption and/or evolution reactions that poison the current state-of-the-art anode catalysts and accelerate the degradation of the anion exchange membrane (AEM). The technically favored solution path for addressing these issues includes development of novel selective catalysts and implementation of limited operating conditions. Therefore, development of highly active, selective, cost-effective, and stable seawater-splitting catalysts is required for a successful commercialization of the AEM water electrolyzers (AEMWEs). In this work, we report for the first-time an extended operation for over 1000 h of advanced AEMWEs, operating directly with seawater. To fabricate the membrane electrode assemblies (MEAs), catalyst coated electrodes (CCEs) are assembled with Sustainion® X37-50 grade T anion exchange membranes. The anode CCEs are fabricated by spraying an ink prepared from nanostructured NiFe-layered double hydroxide (LDH) catalyst that are synthesized by the solvothermal method and deposited directly onto platinized titanium porous transport layers (PTLs). The cathode CCEs are prepared by spraying an ink prepared from commercial Renay-Nickel catalyst onto a nickel fiber felt. As prepared AEM electrolyzer cells operated with seawater and demonstrated better than previously reported in the literature performance of over 1000 h of operation at a constant current density of 300 mA cm –2 .