Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature acceleration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Changes in ratio of soluble sugars and free amino nitrogen in the apical meristem during floral transition of tobacco

Under a modification of the nutrient diversion hypothesis, we propose that an inequality in carbohydrate and nitrogen translocation to the apical meristem may be a controlling factor in floral transition. Experiments were conducted in controlled-environment chambers to determine the associations between microscopic characteristics of the transition from vegetative to floral stages of the apical meristem of flue-cured tobacco and to assimilate concentrations in the plant and apical meristem. Low temperature, nitrogen withdrawal, and restriction of nitrogen uptake were used as treatment variables. In all of these stress treatments, flowering occurred at a lesser number of leaves than in control treatments. Low temperature stress accelerated the time of transition to the floral stage as compared with a high temperature control; however, nitrogen stress did not accelerate the time of transition. All stress treatments affected the levels of nitrogen and carbohydrate in whole plants. Most notable was an increase in the percentage of starch and a decrease in the percentage of total soluble carbohydrate induced by the stress treatments. These data indicate that tobacco plants under stress accumulate excess carbohydrate in the form of starch. An apparent inequality in the relative concentrations of carbohydrate and nitrogen in the apical meristem was observed in all treatments at the time of floral transition and is in support of the nutrient diversion hypothesis.

NASA Discipline Number 61-10↗

Progress with high-field superconducting magnets for high-energy colliders

One of the possible next steps for high-energy physics research relies on a high-energy hadron or muon collider. The energy of a circular collider is limited by the strength of bending dipoles, and its maximum luminosity is determined by the strength of final focus quadrupoles. For this reason, the high-energy physics and accelerator communities have shown much interest in higher-field and higher-gradient superconducting accelerator magnets. The maximum field of NbTi magnets used in all present high-energy machines, including the LHC, is limited to ~10 T at 1.9 K. Fields above 10 T became possible with the use of Nb$_3$Sn superconductors. Nb$_3$Sn accelerator magnets can provide operating fields up to ~15 T and can significantly increase the coil temperature margin. Accelerator magnets with operating fields above 15 T require high-temperature superconductors. Furthermore, this review discusses the status and main results of Nb$_3$Sn accelerator magnet research and development and work toward 20-T magnets.

43 PARTICLE ACCELERATORS↗

Determination of balloon gas mass and revised estimates of drag and virtual mass coefficients

In support of the NASA Balloon Program, small-scale balloons were flown with varying lifting gas and total system mass. Instrument packages were developed to measure and record acceleration and temperature data during these tests. Top fitting and instrument payload accelerations were measured from launch to steady state ascent and through ballast drop transients. The development of the small lightweight self-powered Stowaway Special instrument packages is discussed along with mathematical models developed to determine gas mass, drag and virtual mass coefficients.

Robbins, E.↗

Accelerated-weathering test-system for solar cells

Test system rapidly evaluates effects of sunlight, humidity, and temperature. System accelerates environmental testing since Sunlight is held at equivalent noon exposure (for a selected locality) for 12 hours; alternating light and dark periods are included to check for possible dark reactions in specimens.

Kolyer, J. M.↗

Temperature-Dependent Kinetic Study of Ammonia Oxidation Reaction on Gas Diffusion Electrodes in NH 3 -Saturated 1 M KOH Solutions

Ammonia oxidation reaction (AOR) is sluggish, especially at ambient temperature. To make kinetic study in electrochemical cell more informative and relevant to the catalysts’ performance in direct ammonia fuel cells (DAFCs) operating at about 100°C, it is desirable to study the AOR kinetics at elevated temperatures. However, ammonia evaporation accelerates with increasing temperature causing decrease of ammonia concentration with time. Here, we show a feasible solution to this issue - let argon gas bubble through concentrated ammonia before entering the electrochemical cell so that the solution can be kept ammonia saturated and oxygen free. Repeatable AOR polarization curves were obtained at temperatures up to 60°C. The AOR activities are characterized by the average currents at 0.5 V versus RHE measured at 20 mV s-1 in potential cycles below the potential of peak current. For PtIr/C, the PGM mass activities are 25 A g-1 at 25°C and 225 A g -1 at 60°C. The results for Pt/C and Ir/C and discussion of the causes for their distinct kinetic behavior will be presented at the meeting.

25 ENERGY STORAGE↗

Predicting viscoelastic response and delayed failures in general laminated composites

Although graphite fibers behave in an essentially elastic manner, the polymeric matrix of graphite/epoxy composites is a viscoelastic material which exhibits creep and delayed failures. The creep process is quite slow at room temperature, but may be accelerated by higher temperatures, moisture absorption, and other factors. Techniques are being studied to predict long-term behavior of general laminates based on short-term observations of the unidirectional material at elevated temperatures. A preliminary numerical procedure based on lamination theory is developed for predicting creep and delayed failures in laminated composites. A modification of the Findley nonlinear power law is used to model the constitutive behavior of a lamina. An adaptation of the Tsai-Hill failure criterion is used to predict the time-dependent strength of a lamina. Predicted creep and delayed failure results are compared with typical experimental data.

Dillard, D. A.↗

Thermal Characterization Study of Lithium-Ion Cells

The primary challenge in designing a full scale lithium-ion (Li-ion) battery system is safety under both normal operating as well as abusive conditions. The normal conditions involve expected charge/discharge cycles and it is known that heat evolves in batteries during those cycles. This is a major concern in the design for high power applications and careful thermal management is necessary to alleviate this concern. An emerging thermal measurement technology, such as the electrochemical calorimetric of batteries, will aid in the development of advanced, safe battery system. To support this technology, several "commercial-off-the-shelf" (COTS) Li-ion cells with different chemistries and designs are being evaluated for different cycling regimes at a given operating temperature. The Accelerated Rate Calorimeter (ARC)-Arbin cycler setup is used to measure the temperature, voltage, and current of the cells at different charge/discharge rates. Initial results demonstrated good cell cyclability. During the cycle testing, the cell exhibited an endothermic cooling in the initial part of the charge cycle. The discharge portion of the cycle is exothermic during the entire discharge period. The presence of an endothermic reaction indicates a significant entropy effect during the beginning of charge cycle. Further studies will be performed to understand the thermal characteristics of the Li-ion cells at the different operating conditions. The effects on the thermal response on cell aging and states-of-charge will also be identified.

Britton, Doris L.↗

Correlation of Qualification and Accelerated Testing with Field Degradation

Qualification testing of solar photovoltaic (PV) modules per IEC 61215 standard encompasses a set of well-defined accelerated stress tests (irradiation, environmental, mechanical and electrical) with strict pass/fail criteria based on functionality/performance, electrical and mechanical safety, and visual requirements. The qualification testing does not identify all the possible reliability failures or durability issues witnessed in the actual field. However, it does identify the major/catastrophic design quality issues (infant mortality), which could occur early in a module’s field life. Unfortunately, in the industry, there is no consensus-based standard or protocol available to validate manufacturers’ warranty period claims based on the end-of-life wear-out failure mechanisms. Being able to predict the field degradation rates and lifetime using mode-specific accelerated tests on moderately field-aged modules, for example 10 years, for certain commonly occurring degradation modes would be a powerful contribution to all the stakeholders of the PV industry. There is a need to formulate guidelines to find the correlation of accelerated testing with field degradation for individual degradation modes observed in the field. Potential approaches to fulfill this need were experimented in this project and are presented in this report. Two of the most commonly seen degradation modes – encapsulant browning and solder bond thermomechanical fatigue – are addressed in this report through presenting the accelerated testing methods and physical modelling approaches. Two accelerated test methods (UV and thermal cycling) were designed to induce the wear-out mechanisms in the modules and not infant mortality failures. To focus on the wear-out failure modes, the tests were performed on field-aged modules, instead of fresh modules, with known degradation rates and degradation modes. The degradation rates were measured based on the degradation rates of individual cell parameters (short-circuit current, I sc and series resistance, R s ) instead of the degradation rate of maximum power (P max ) which cannot be used to study any specific/limited degradation mode as the P max degradation could be caused by many different degradation modes. The key characteristic parameter considered for encapsulant discoloration and solder bond degradation is I sc and R s , respectively. The developed physical models/equations relating the testing degradation data and field weather data were utilized to determine the acceleration factor (AF) and to predict the degradation rate for a specific degradation mode of PV modules installed in two different climates, Arizona (hot) and New York (cold). The predicted degradation rates for encapsulant browning and solder bond degradation have also been validated against the actual measured field degradation rates. UV testing cost reduction: To determine acceleration factor, single UV chamber was used for accelerated UV testing at three different temperatures simultaneously, instead of three chambers for three temperatures (or one chamber sequentially which is an extremely time-consuming approach). A passive heating approach was successfully used to achieve and maintain multiple temperatures in the accelerated UV chamber. Foam insulation boards of varying thicknesses were utilized to obtain three different temperatures for UV testing. However, these foam materials tend to disintegrate in the presence of moisture. To alleviate this problem, silicone heating blankets with temperature controls and humidifier can be used if the UV testing is to be performed under hot-humid conditions instead of conventional hot-dry conditions. Thermal cycling testing cost reduction: Single thermal cycling chamber was used for accelerated thermal cycling testing at three different upper temperatures simultaneously, instead of three chambers for three upper temperatures (or one chamber sequentially which is an extremely time-consuming approach). An active heating approach based on silicone heating blankets was successfully used to achieve and maintain multiple upper temperatures in the accelerated thermal cycling chamber. Such blankets provide stable temperature control and thereby more reliable and repeatable for replicate experiments.

14 SOLAR ENERGY↗

The Huygens Atmospheric Structure Instrument (HASI): Expected Results at Titan and Performance Verification in Terrestrial Atmosphere

The Huygens ASI is a multi-sensor package resulting from an international cooperation, it has been designed to measure the physical quantities characterizing Titan's atmosphere during the Huygens probe mission. On 14th January, 2005, HASI will measure acceleration, pressure, temperature and electrical properties all along the Huygens probe descent on Titan in order to study Titan s atmospheric structure, dynamics and electric properties. Monitoring axial and normal accelerations and providing direct pressure and temperature measurements during the descent, HASI will mainly contribute to the Huygens probe entry and trajectory reconstruction. In order to simulate the Huygens probe descent and verify HASI sensors performance in terrestrial environment, stratospheric balloon flight experiment campaigns have been performed, in collaboration with the Italian Space Agency (ASI). The results of flight experiments have allowed to determine the atmospheric vertical profiles and to obtain a set of data for the analysis of probe trajectory and attitude reconstruction.

Ferri, F.↗

Temperature Measurements in the Magnetic Measurement Facility

Several key LCLS undulator parameter values depend strongly on temperature primarily because of the permanent magnet material the undulators are constructed with. The undulators will be tuned to have specific parameter values in the Magnetic Measurement Facility (MMF). Consequently, it is necessary for the temperature of the MMF to remain fairly constant. Requirements on undulator temperature have been established. When in use, the undulator temperature will be in the range 20.0 {+-} 0.2 C. In the MMF, the undulator tuning will be done at 20.0 {+-} 0.1 C. For special studies, the MMF temperature set point can be changed to a value between 18 C and 23 C with stability of {+-}0.1 C. In order to ensure that the MMF temperature requirements are met, the MMF must have a system to measure temperatures. The accuracy of the MMF temperature measurement system must be better than the {+-}0.1 C undulator tuning temperature tolerance, and is taken to be {+-}0.01 C. The temperature measurement system for the MMF is under construction. It is similar to a prototype system we built two years ago in the Sector 10 alignment lab at SLAC. At that time, our goal was to measure the lab temperature to {+-}0.1 C. The system has worked well for two years and has maintained its accuracy. For the MMF system, we propose better sensors and a more extensive calibration program to achieve the factor of 10 increase in accuracy. In this note we describe the measurement system under construction. We motivate our choice of system components and give an overview of the system. Most of the software for the system has been written and will be discussed. We discuss error sources in temperature measurements and show how these errors have been dealt with. The calibration system is described in detail. All the LCLS undulators must be tuned in the Magnetic Measurement Facility at the same temperature to within {+-}0.1 C. In order to ensure this, we are building a system to measure the temperature of the undulators to {+-}0.01 C. This note describes the temperature measurement system under construction.

43 PARTICLE ACCELERATORS↗

An investigation of chatter and tool wear when machining titanium

The low thermal conductivity of titanium, together with the low contact area between chip and tool and the unusually high chip velocities, gives rise to high tool tip temperatures and accelerated tool wear. Machining speeds have to be considerably reduced to avoid these high temperatures with a consequential loss of productivity. Restoring this lost productivity involves increasing other machining variables, such as feed and depth-of-cut, and can lead to another machining problem commonly known as chatter. This work is to acquaint users with these problems, to examine the variables that may be encountered when machining a material like titanium, and to advise the machine tool user on how to maximize the output from the machines and tooling available to him. Recommendations are made on ways of improving tolerances, reducing machine tool instability or chatter, and improving productivity. New tool materials, tool coatings, and coolants are reviewed and their relevance examined when machining titanium.

Sutherland, I. A.↗

Ignition delay times of NH 3 /DME blends at high pressure and low DME fraction: RCM experiments and simulations

Here, autoignition delay times of ammonia/dimethyl ether (NH 3 /DME) mixtures were measured in a rapid compression machine with DME fractions of 0, 2 and 5 and 100% in the fuel. The measurements were performed at equivalence ratios $\varphi$= 0.5, 1.0 and 2.0 and pressures in the range 10–70 bar; depending on the fuel composition, the temperatures after compression varied from 610 K to 1180 K. Admixture of DME is seen to have a dramatic effect on the ignition delay time, effectively shifting the curves of ignition delay vs. temperature to lower temperatures, up to ~250 K compared to pure ammonia. Two-stage ignition is observed at $\varphi$= 1.0 and 2.0 with 2% and 5% DME in the fuel, despite the pressure being higher than that at which pure DME shows two-stage ignition. At $\varphi$= 0.5, a reproducible pre-ignition pressure rise is observed for both DME fractions, which is not observed in the pure fuel components. A novel NH 3 /DME mechanism was developed, including modifications in the NH 3 subset and addition of the NH 2 + CH 3 OCH 3 reaction, with rate coefficients calculated from ab initio theory. Simulations faithfully reproduce the observed pre- ignition pressure rise. While the mechanism also exhibits two-stage ignition for NH 3 /DME mixtures, both qualitative and quantitative improvement is recommended. The overall ignition delay times for ammonia/DME mixtures are predicted well, generally being within 50% of the experimental values, although reduced performance is observed for pure ammonia at $\varphi$= 2.0. Simulating the ignition process, we observe that the DME is oxidized much more rapidly than ammonia. Analysis of the mechanism indicates that this ‘early DME oxidation’ generates reactive species that initiate the oxidation of ammonia, which in turn begins heat release that raises the temperature and accelerates the oxidation process towards ignition. The reaction path analysis shows that the low-temperature chain-branching reactions of DME are important in the early oxidation of the fuel, while the sensitivity analysis indicates that several reactions in the oxidation of DME, including cross reactions between DME and NH 3 species presented here, are critical to ignition, even at fractions of 2% DME in the fuel.

10 SYNTHETIC FUELS↗

Accelerated oxidation of epoxy thermosets with increased O 2 pressure

Polymer oxidation is usually accelerated with temperature, which is therefore applied in nearly every experimental approach dealing with predictive materials aging. Because of this simple approach, we may tend to neglect that the effective concentration of oxygen also acts as a rate multiplier for oxidation. Increasing the oxygen partial pressure in an aging environment accelerates oxidation, and while there is often a near proportional increase initially, the effect of additional oxygen usually transitions to a saturation level at some elevated pressure. This has been theoretically described in the general autoxidation scheme and is well recognized. However, for many materials the exact rate behavior under moderately increased oxygen concentration remains to be established. We therefore review epoxy oxidation and offer a broader overview of its behavior under increased O 2 partial pressure. Experimental data are given for a few thermoset materials demonstrating their rate behavior under O 2 partial pressure up to 4 atm, meaning approximately 20 times more than under standard atmospheric conditions. Confirmative evidence suggests that epoxy materials will reach saturation oxidation rates only at significantly higher O 2 partial pressure. In such a high-pressure regime it is theoretically possible to not only accelerate oxidation, but to transition into a condition where O 2 diffusion can be increased without further accelerating the oxidation rate. Finally, this can reduce diffusion limited oxidation effects under specific accelerated aging conditions as a combination of temperature and O 2 partial pressure.

36 MATERIALS SCIENCE↗

REVIEW OF PLUTONIUM OXIDATION LITERATURE

A brief review of plutonium oxidation literature was conducted. The purpose of the review was to ascertain the effect of oxidation conditions on oxide morphology to support the design and operation of the PDCF direct metal oxidation (DMO) furnace. The interest in the review was due to a new furnace design that resulted in oxide characteristics that are different than those of the original furnace. Very little of the published literature is directly relevant to the DMO furnace operation, which makes assimilation of the literature data with operating conditions and data a convoluted task. The oxidation behavior can be distilled into three regimes, a low temperature regime (RT to 350 C) with a relatively slow oxidation rate that is influenced by moisture, a moderate temperature regime (350-450 C) that is temperature dependent and relies on more or less conventional oxidation growth of a partially protective oxide scale, and high temperature oxidation (> 500 C) where the metal autocatalytically combusts and oxidizes. The particle sizes obtained from these three regimes vary with the finest being from the lowest temperature. It is surmised that the slow growth rate permits significant stress levels to be achieved that help break up the oxides. The intermediate temperatures result in a fairly compact scale that is partially protective and that grows to critical thickness prior to fracturing. The growth rate in this regime may be parabolic or paralinear, depending on the oxidation time and consequently the oxide thickness. The high temperature oxidation is invariant in quiescent or nearly quiescent conditions due to gas blanketing while it accelerates with temperature under flowing conditions. The oxide morphology will generally consist of fine particles (<15 {micro}m), moderately sized particles (15 < x < 250 {micro}m) and large particles (> 250 {micro}m). The particle size ratio is expected to be < 5%, 25%, and 70% for fine, medium and large particles, respectively, for metal temperatures in the 500-600 C range.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Accumulated destructive effect of nanosecond repetitive voltage pulses on the insulated coatings of Fe-based nanocrystalline ribbon

Fe-based nanocrystalline ribbon is widely employed in pulsed power devices and accelerators. A temperature accumulation model is put forward to explain the accumulated destructive effect of discharge plasma bombardment on the TiO{sub 2} coatings of nanocrystalline ribbon under 50 Hz/100 ns voltage pulses. Experimental results revealed that the plasma channel expansion caused by air breakdown in the coating crack heated the coating repetitively, and the coating temperature was increased and accumulated around the crack. The fact that repetitive voltage pulses were more destructive than a single pulse with the same amplitude was caused by the intensified coating ablation under the temperature accumulation effect.

36 MATERIALS SCIENCE↗

Transverse Field Perturbation For PIP-II SRF Cavities

Proton Improvement Plan II (PIP-II) consists in a plan for upgrading the Fermilab proton accelerator complex to a beam power capability of at least 1 MW delivered to the neutrino production target. A room temperature section accelerates H⁻ ions to 2.1 MeV and creates the desired bunch structure for injection into the superconducting (SC) linac. Five cavity types, operating at three different frequencies 162.5, 325 and 650 MHz, provide acceleration to 800 MeV. This paper presents the studies on transverse field perturbation on particle dynamic for all the superconducting cavities in the linac. The effects studied include quadrupole defocusing for coaxial resonators, and dipole kick due to couplers for elliptical cavities. A multipole expansion has been performed for each of the cavity designs including effects up to octupole.

43 PARTICLE ACCELERATORS↗

Results of metallographical diagnostic examination of Navy half-watt thermoelectric converters degraded by accelerated tests

To verify the 15-year reliability of the Navy half-watt radioisotope thermoelectric generator (RTG), bismuth-telluride thermoelectric converters were submitted to testing at high temperatures which accelerated the degradation and caused failure of the converters. Metallographic diagnostic examination of failed units verified failure mechanisms. Results of diagnostic examinations are presented.

Rosell, F. E., Jr.↗

Titanium-Water Thermosyphon Gamma Radiation Effects and Results

Titanium-water thermosyphons are being considered for use in heat rejection systems for fission power systems. Their proximity to the nuclear reactor will result in some exposure to gamma irradiation. Non-condensable gas formation from radiation may breakdown water over time and render a portion of the thermosyphon condenser inoperable. A series of developmental thermosyphons were operated at nominal operating temperature with accelerated gamma irradiation exposures on the same order of magnitude that is expected in eight years of heat rejection system operation. Temperature data were obtained during exposure at three locations on each thermosyphon; evaporator, condenser, and condenser end cap. Some non-condensable gas was evident, however thermosyphon performance was not affected because the non-condensable gas was compressed into the fill tube region at the top of the thermosyphon, away from the heat rejecting fin. The trend appeared to be an increasing amount of non-condensable gas formation with increasing gamma irradiation dose. Hydrogen is thought to be the most likely candidate for the non-condensable gas and hydrogen is known to diffuse through grain boundaries. Post-exposure evaluation of selected thermosyphons at temperature and in a vacuum chamber revealed that the non-condensable gas likely diffused out of the thermosyphons over a relatively short period of time. Further research shows a number of experimental and theoretical examples of radiolysis occurring through gamma radiation alone in pure water.

Sanzi, James L.↗