Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “systematic errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

SU-E-J-37: Combining Proton Radiography and X-Ray CT Information to Better Estimate Relative Proton Stopping Power in a Clinical Environment

Purpose: In standard proton therapy clinical practice, proton stopping power uncertainties are in the order of 3.5%, which affects the ability of placing the proton Bragg peak at the edge of the tumor. The innovating idea of this project is to approach the uncertainty problem in RSP by using combined information from X-ray CT and proton radiography along a few beam angles. In addition, this project aims to quantify the systematic error introduced by the theoretical models (Janni, ICRU49, Bischel) for proton stopping power in media. Methods: A 3D phantom of 36 cm3 composed of 9 materials randomly placed is created. Measured RSP values are obtained using a Gammex phantom with a proton beam. Theoretical RSP values are calculated with Beth-Block equation in combination with three databases (Janni, ICRU49 and Bischel). Clinical RSP errors are simulated by introducing a systematic (1.5%, 2.5%, 3.5%) and a random error (+/−0.5%) to the theoretical RSP. A ray-tracing algorithm uses each of these RSP tables to calculate energy loss for proton crossing the phantom through various directions. For each direction, gradient descent (GD) method is done on the clinical RSP table to minimize the residual energy difference between the simulation with clinical RSP and with theoretical RSP. The possibility of a systematic material dependent error is investigated by comparing measured RSP to theoretical RSP as calculated from the three models. Results: Using 10,000 iterations on GD algorithm, RSP differences between theoretical values and clinical RSP have converged (<1%) for each error introduced. Results produced with ICRU49 have the smallest average difference (0.021%) to the measured RSP. Janni (1.168%) and Bischel (−0.372%) database shows larger systematic errors. Conclusion: Based on these results, ray-tracing optimisation using information from proton radiography and X-ray CT demonstrates a potential to improve the proton range accuracy in a clinical environment.

07 ISOTOPE AND RADIATION SOURCES↗

RED NOISE VERSUS PLANETARY INTERPRETATIONS IN THE MICROLENSING EVENT OGLE-2013-BLG-446

For all exoplanet candidates, the reliability of a claimed detection needs to be assessed through a careful study of systematic errors in the data to minimize the false positives rate. We present a method to investigate such systematics in microlensing data sets using the microlensing event OGLE-2013-BLG-0446 as a case study. The event was observed from multiple sites around the world and its high magnification (A{sub max} ∼ 3000) allowed us to investigate the effects of terrestrial and annual parallax. Real-time modeling of the event while it was still ongoing suggested the presence of an extremely low-mass companion (∼3M{sub ⨁}) to the lensing star, leading to substantial follow-up coverage of the light curve. We test and compare different models for the light curve and conclude that the data do not favor the planetary interpretation when systematic errors are taken into account.

79 ASTRONOMY AND ASTROPHYSICS↗

Raytracing the long trace profiler

The optical design of the Long Trace Profiler optical system is explored with a commercial raytrace program, Zemax OpticStudio™ (ZOS)1, with the intent of finding and correcting sources of systematic error. ZOS provides both geometric raytracing tools and physical optics Gaussian beam propagation and diffraction image calculation tools, and two design modes, sequential component (SC) and non-sequential component (NSC) that are optimized for different aspects of the design process. The original LTP-II system employs a singlet lens with a 1250 mm focal length. It is optimized to provide minimum distortion over a surface slope angle range of ±5 mrad. Using the ZOS tools, we are able to simulate ghost rays that produce distortion in the beam spot image and can minimize the distortion by deliberate misalignment of the beamsplitter (BS) components. Unfortunately, the reference beam is compromised because of the component tilts. The most recent LTP500 system design simplifies the optical system and makes the reference beam usable again, even with misalignment of the polarizing beamsplitter (PBS). Two lenses are designed for the LTP500 - a cemented doublet that has been fabricated, and a singlet with one aspheric surface. Both have focal distances of 500 mm with an expanded angular measurement range of ±10 mrad. The aspheric singlet provides superior performance. ZOS allows the import of wavefront measurement data produced by commercial interferometer software. We apply the wavefront error measurement from the cemented doublet to the model to show that the 19nm RMS wavefront error needs to be improved by at least a factor of ten in order to reduce the systematic error to a level that will allow the LTP to approach its design limit of a few tens of nanoradians.

Takacs, Peter Z.↗

Measurement of the jet radius and transverse momentum dependence of inclusive jet suppression in lead-lead collisions at s N N = 2.76 TeV with the ATLAS detector

CERN-LHC. Measurements of the ratio, Rcp, between jet production in the central to peripheral regions in Lead Lead collisions at a centre of mass energy/nucleon of 2.76 TeV. Jets are reconstructed with |eta|<2.1, covering the jet PT range 38-210 GeV, using the anti-Kt algorithm with norminal jet radii of R=0.2, 0.3, 0.4 and 0.5. Seven regions of centrality are considered from the most peripheral of 60-80% to the most central 0-10%. Rcp is studied as a function of jet PT, number of participating nucleons NPART and R for each of the centrality regions, as well as the ratio of Rcp/Rcp(R=0.2) as a function of jet PT for each R=0.3, 0.4 and 0.5. Finally values of the covariance matrix for staistical correlations between jet PT bins are given. In the tables the first systematic errors are from JES, JER, efficiency, xin and Rcoll and are 100% correlated in PT. The second systematic errors are those that are partially correlated or uncorrelated in pt, taken to be 100% uncorrelated, from the regularization parameter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A NEW ABUNDANCE SCALE FOR THE GLOBULAR CLUSTER 47 Tuc

We present chemical abundances for O, Na, Mg, Al, Si, Ca, Ti, and Fe in eight red giants and one turnoff star in the metal-rich globular cluster 47 Tuc, based on spectroscopy with the Magellan Inamori Kyocera Echelle high-resolution spectrograph on the Magellan 6.5 m Clay telescope. A robust line by a line differential abundance analysis technique, relative to the K-giant Arcturus, was used to reduce systematic errors from atmospheric and atomic parameters. Our derived mean LTE [Fe/H] of -0.76 {+-} 0.01 {+-} 0.04 dex (random and systematic error, respectively) is more metal poor by about 0.1 dex than recent literature results. The chemical element ratios in this nearby globular cluster most closely resemble those of the Galactic bulge, although there is a non-negligible overlap with the composition of thick-disk stars. We find that the [Al/Fe] and [Na/Fe] ratios coincide with the upper boundary of the trends seen in the bulge and thick disk. There is only a small intrinsic scatter in the majority of the abundance ratios, indicating that 47 Tuc is mostly a rather chemically homogeneous system.

79 ASTRONOMY AND ASTROPHYSICS↗

Unraveling duality violations in hadronic tau decays

There are some indications from recent determinations of the strong coupling constant alpha_s and the gluon condensate that the Operator Product Expansion may not be accurate enough to describe non-perturbative effects in hadronic tau decays. This breakdown of the Operator Product Expansion is usually referred to as being due to"Duality Violations." With the help of a physically motivated model, we investigate these duality violations. Based on this model, we argue how they may introduce a non-negligible systematic error in the current analysis, which employs finite-energy sum rules with pinched weights. In particular, this systematic effect might affect the precision determination of alpha_s from tau decays. With a view to a possible future application to real data, we present an alternative method for determining the OPE coefficients that might help estimating, and possibly even reducing, this systematic error.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

THE HUBBLE SPACE TELESCOPE CLUSTER SUPERNOVA SURVEY. V. IMPROVING THE DARK-ENERGY CONSTRAINTS ABOVE z > 1 AND BUILDING AN EARLY-TYPE-HOSTED SUPERNOVA SAMPLE

We present Advanced Camera for Surveys, NICMOS, and Keck adaptive-optics-assisted photometry of 20 Type Ia supernovae (SNe Ia) from the Hubble Space Telescope (HST) Cluster Supernova Survey. The SNe Ia were discovered over the redshift interval 0.623 < z < 1.415. Of these SNe Ia, 14 pass our strict selection cuts and are used in combination with the world's sample of SNe Ia to derive the best current constraints on dark energy. Of our new SNe Ia, 10 are beyond redshift z = 1, thereby nearly doubling the statistical weight of HST-discovered SNe Ia beyond this redshift. Our detailed analysis corrects for the recently identified correlation between SN Ia luminosity and host galaxy mass and corrects the NICMOS zero point at the count rates appropriate for very distant SNe Ia. Adding these SNe improves the best combined constraint on dark-energy density, {rho}{sub DE}(z), at redshifts 1.0 < z < 1.6 by 18% (including systematic errors). For a flat {Lambda}CDM universe, we find {Omega}{sub {Lambda}} = 0.729 {+-} 0.014 (68% confidence level (CL) including systematic errors). For a flat wCDM model, we measure a constant dark-energy equation-of-state parameter w = -1.013{sup +0.068}{sub -0.073} (68% CL). Curvature is constrained to {approx}0.7% in the owCDM model and to {approx}2% in a model in which dark energy is allowed to vary with parameters w{sub 0} and w{sub a} . Further tightening the constraints on the time evolution of dark energy will require several improvements, including high-quality multi-passband photometry of a sample of several dozen z > 1 SNe Ia. We describe how such a sample could be efficiently obtained by targeting cluster fields with WFC3 on board HST. The updated supernova Union2.1 compilation of 580 SNe is available at http://supernova.lbl.gov/Union.

79 ASTRONOMY AND ASTROPHYSICS↗

Assessment of Model Confidence of a Laser Source Model in xRAGE Using Omega Direct-Drive Implosion Experiments

Los Alamos National Laboratory is interested in developing high-energy-density physics validation capabilities for its multiphysics code xRAGE. xRAGE was recently updated with the laser package Mazinisin to improve predictability. We assess the current implementation and coupling of the laser package via validation of laser-driven, direct-drive spherical capsule experiments from the Omega laser facility. Here, the ASME V&V 20-2009 standard is used to determine the model confidence of xRAGE, and considerations for high-energy-density physics are identified. With current modeling capabilities in xRAGE, the model confidence is overwhelmed by significant systematic errors from the experiment or model. Validation evidence suggests cross-beam energy transfer as a dominant source of the systematic error.

47 OTHER INSTRUMENTATION↗

Correcting for Selection Biases in the Determination of the Hubble Constant from Time-Delay Cosmography

The time delay between multiple images of strongly lensed quasars has been used to infer the Hubble constant. The primary systematic uncertainty for time-delay cosmography is the mass-sheet transform (MST), which preserves the lensing observables while altering the inferred ⁠H 0 . The TDCOSMO collaboration used velocity dispersion measurements of lensed quasars and lensed galaxies to infer that mass sheets are present, which decrease the inferred H 0 by 8 per cent. Here, we test the assumption that the density profiles of galaxy–galaxy and galaxy–quasar lenses are the same. We use a composite star-plus-dark-matter mass profile for the parent deflector population and model the selection function for galaxy–galaxy and galaxy–quasar lenses. We find that a power-law density profile with an MST is a good approximation to a two-component mass profile around the Einstein radius, but we find that galaxy–galaxy lenses have systematically higher mass-sheet components than galaxy–quasar lenses. For individual systems, λ int correlates with the ratio of the half-light radius and Einstein radius of the lens. By propagating these results through the TDCOSMO hierarchical inference code, we find that H 0 is lowered by a further 3 per cent. Using a more recent measurement of velocity dispersions and our fiducial model for selection biases, we infer H 0 = 66 ± 4 (stat) ± 1 (model sys) ± 2 (measurement sys) km s -1 Mpc -1 for the TDCOSMO plus SLACS data set. The first residual systematic error is due to plausible alternative choices in modelling the selection function, and the second is an estimate of the remaining systematic error in the measurement of velocity dispersions for SLACS lenses. Accurate time-delay cosmography requires precise velocity dispersion measurements and accurate calibration of selection biases.

79 ASTRONOMY AND ASTROPHYSICS↗

Reynolds stress tensor measurements using magnetic resonance velocimetry: expansion of the dynamic measurement range and analysis of systematic measurement errors

This study presents magnetic resonance velocimetry (MRV) Reynolds Stress measurements in a periodic hill channel with a hill Reynolds number of Re = 29,500. The velocity encoding scheme is based on the ICOSA6 method with six icosahedral encoding directions and multiple encoding values are measured to increase the dynamic range. The full Reynolds stress tensor is obtained from a voxel-wise three-dimensional Gaussian fit using the magnitude data of all acquisitions. The MRV results are compared to a wall-resolved large eddy simulation and laser Doppler velocimetry measurements conducted in the same channel. It is shown that the MRV Reynolds stress data have excellent precision and agree qualitatively with the reference data. However, there are apparent systematic deviations. One of the most prominent error contributions is the signal attenuation caused by higher orders of motion, which leads to an overestimation of the turbulence level. Another fundamental error is identified in the assumption that the turbulence is Gaussian distributed. With the presented reconstruction technique, the MRV data are fitted to a statistical model, and depending on the examined flow setup, the Gaussian model can lead to considerable errors. Possible ways of how to reduce all identified errors are presented. In summary, this technique enables Reynolds stress tensor measurements in complex internal flows with high dynamic range and excellent precision. However, several issues need to be resolved to make the turbulence quantification more accurate.

42 ENGINEERING↗

Determining the WIMP mass from a single direct detection experiment; a more detailed study

The energy spectrum of nuclear recoils in weakly interacting massive particle (WIMP) direct detection experiments depends on the underlying WIMP mass. We study how the accuracy with which the WIMP mass could be determined by a single direct detection experiment depends on the detector configuration and the WIMP properties. We investigate the effects of varying the underlying WIMP mass and cross-section, the detector target nucleus, exposure, energy threshold and maximum energy, the local circular speed and the background event rate and spectrum. The number of events observed is directly proportional to both the exposure and the cross-section; therefore these quantities have the greatest bearing on the accuracy of the WIMP mass determination. The relative capabilities of different detectors for determining the WIMP mass depend not only on the WIMP and target masses, but also on their energy thresholds. The WIMP and target mass dependence of the characteristic energy scale of the recoil spectrum suggests that heavy targets will be able to measure the mass of a heavy WIMP more accurately. We find, however, that the rapid decrease of the nuclear form factor with increasing momentum transfer which occurs for heavy nuclei means that this is in fact not the case. Uncertainty in the local circular speed and non-negligible background would both lead to systematic errors in the WIMP mass determination. For deviations of {+-} 20 km s{sup -1} in the underlying value of the circular speed the systematic error is of order 10%, increasing with increasing WIMP mass. This error can be reduced by also fitting for the circular speed. With a single detector it will be difficult to disentangle a WIMP signal (and the WIMP mass) from background if the background spectrum has a similar shape to the WIMP spectrum (i.e. exponential background, or flat background and a heavy WIMP)

79 ASTRONOMY AND ASTROPHYSICS↗

A NEW METHOD FOR MEASURING EXTRAGALACTIC DISTANCES

We have pioneered a new method for the measurement of extragalactic distances. This method uses the time lag between variations in the short wavelength and long wavelength light from an active galactic nucleus (AGN), based on a quantitative physical model of dust reverberation that relates the time lag to the absolute luminosity of the AGN. We use the large homogeneous data set from intensive monitoring observations in optical and near-infrared wavelength bands with the dedicated 2 m MAGNUM telescope to obtain the distances to 17 AGNs in the redshift range z = 0.0024 to z = 0.0353. These distance measurements are compared with distances measured using Cepheid variable stars, and are used to infer that H {sub 0} = 73 ± 3 (random) km s{sup –1} Mpc{sup –1}. The systematic error in H {sub 0} is examined, and the uncertainty in the size distribution of dust grains is the largest source of the systematic error, which is much reduced for a sample of AGNs for which their parameter values in the model of dust reverberation are individually measured. This AGN time lag method can be used beyond 30 Mpc, the farthest distance reached by extragalactic Cepheids, and can be extended to high-redshift quasi-stellar objects.

79 ASTRONOMY AND ASTROPHYSICS↗

Description and first application of a new technique to measure the gravitational mass of antihydrogen

Physicists have long wondered whether the gravitational interactions between matter and antimatter might be different from those between matter and itself. Although there are many indirect indications that no such differences exist and that the weak equivalence principle holds, there have been no direct, free-fall style, experimental tests of gravity on antimatter. Here we describe a novel direct test methodology; we search for a propensity for antihydrogen atoms to fall downward when released from the ALPHA antihydrogen trap. In the absence of systematic errors, we can reject ratios of the gravitational to inertial mass of antihydrogen 475 at a statistical significance level of 5%; worst-case systematic errors increase the minimum rejection ratio to 110. A similar search places somewhat tighter bounds on a negative gravitational mass, that is, on antigravity. This methodology, coupled with ongoing experimental improvements, should allow us to bound the ratio within the more interesting near equivalence regime.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Methods to determine the radiated power in SPI-mitigated disruptions in JET

Here we present techniques for evaluating the radiated power in JET disruptions. Disrupting plasmas are shown to have non-axisymmetric radiation profiles, motivating the re-evaluation of the standard techniques for calculating the total radiated power at JET using bolometry. Four single-channel bolometers at different toroidal locations are exploited to quantify the radiation asymmetry. Toroidal radiation peaking factors integrated over the entire disruption of up to 1.5 have been observed when varying the quantity of neon in pellets used in disruptions mitigated by shattered pellet injection. Using synthetic bolometer diagnostics developed with the Cherab spectroscopy modeling framework, we can estimate the systematic error on total power calculations for relevant radiation profiles and improve estimates of the total radiated power. We show that the component of the systematic error on the total power due to the poloidal radiation profile can be reduced from 70% to 10% with suitable assumptions about the structure of the poloidal profile.

47 OTHER INSTRUMENTATION↗

Casting the Coronal Magnetic Field Reconstruction Tools in 3D Using the MHD Bifrost Model

Quantifying the coronal magnetic field remains a central problem in solar physics. Nowadays, the coronal magnetic field is often modeled using nonlinear force-free field (NLFFF) reconstructions, whose accuracy has not yet been comprehensively assessed. Here we perform a detailed casting of the NLFFF reconstruction tools, such as π -disambiguation, photospheric field preprocessing, and volume reconstruction methods, using a 3D snapshot of the publicly available full-fledged radiative MHD model. Specifically, from the MHD model, we know the magnetic field vector in the entire 3D domain, which enables us to perform a “voxel-by-voxel” comparison of the restored and the true magnetic fields in the 3D model volume. Our tests show that the available π -disambiguation methods often fail in the quiet-Sun areas dominated by small-scale magnetic elements, while they work well in the active region (AR) photosphere and (even better) chromosphere. The preprocessing of the photospheric magnetic field, although it does produce a more force-free boundary condition, also results in some effective “elevation” of the magnetic field components. This “elevation” height is different for the longitudinal and transverse components, which results in a systematic error in absolute heights in the reconstructed magnetic data cube. The extrapolations performed starting from the actual AR photospheric magnetogram are free from this systematic error, while other metrics are comparable with those for extrapolations from the preprocessed magnetograms. This finding favors the use of extrapolations from the original photospheric magnetogram without preprocessing. Our tests further suggest that extrapolations from a force-free chromospheric boundary produce measurably better results than those from a photospheric boundary.

79 ASTRONOMY AND ASTROPHYSICS↗

Accuracy of cranial coplanar beam therapy using an oblique, stereoscopic x-ray image guidance system

A system for measuring two-dimensional (2D) dose distributions in orthogonal anatomical planes in the cranium was developed and used to evaluate the accuracy of coplanar conformal therapy using ExacTrac image guidance. Dose distributions were measured in the axial, sagittal, and coronal planes using a CIRS (Computerized Imaging Reference Systems, Inc.) anthropomorphic head phantom with a custom internal film cassette. Sections of radiographic Kodak EDR2 film were cut, processed, and digitized using custom templates. Spatial and dosimetric accuracy and precision of the film system were assessed. BrainScan planned a coplanar-beam treatment to conformally irradiate a 2-cm-diameterx2-cm-long cylindrical planning target volume. Prior to delivery, phantom misalignments were imposed in combinations of {+-}8 mm offsets in each of the principal directions. ExacTrac x-ray correction was applied until the phantom was within an acceptance criteria of 1 mm/1 deg. (first two measurement sets) or 0.4 mm/0.4 deg. (last two measurement sets). Measured dose distributions from film were registered to the treatment plan dose calculations and compared. Alignment errors, displacement between midpoints of planned and measured 70% isodose contours ({delta}c), and positional errors of the 80% isodose line were evaluated using 49 2D film measurements (98 profiles). Comparison of common, but independent measurements of {delta}c showed that systematic errors in the measurement technique were 0.2 mm or less along all three anatomical axes and that random error averaged ({sigma}{+-}{sigma}{sub {sigma}}) 0.29{+-}0.06 mm for the acceptance criteria of 1 mm/1 deg. and 0.15{+-}0.02 mm for the acceptance criteria of 0.4 mm/0.4 deg. . The latter was consistent with independent estimates that showed the precision of the measurement system was 0.3 mm (2{sigma}). Values of {delta}c were as great as 0.9, 0.3, and 1.0 mm along the P-A, R-L, and I-S axes, respectively. Variations in {delta}c along the P-A axis were correlated to misalignments between laser isocenter and radiation isocenter as documented by daily clinical Lutz tests. Based on results of comparisons of measured with calculated positions of the 80% dose lines along the major anatomical axes, a 1.25, 1.0, and 1.0 mm (0.75, 0.5, and 0.25 mm) gross tumor volume (GTV)-planning target volume (PTV) margin to account for delivery error would be appropriate for the P-A, R-L, and I-S axes, respectively, for an acceptance criteria of 1 mm/1 deg. (0.4 mm/0.4 deg. ). It typically took 2 (3) ExacTrac x-ray image sets to achieve and verify acceptance criteria of 1 mm/1 deg. (0.4 mm/0.4 deg. ). Our results demonstrated a measurement technique using a CIRS anthropomorphic head phantom with a modified film cassette, radiographic film (Kodak EDR2) with a custom film cutting template, and film dosimetry software has been developed and successfully applied to our clinic. It is recommended that a third party offer this service. Our goal of achieving accuracy of delivery of 1 mm or better in each of the three major anatomical axes was almost, but not quite achieved, not because of the accuracy of the image guidance system, but likely due to inaccuracy of laser isocenter and other systematic errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

GALAXY BIAS AND ITS EFFECTS ON THE BARYON ACOUSTIC OSCILLATION MEASUREMENTS

The baryon acoustic oscillation (BAO) feature in the clustering of matter in the universe serves as a robust standard ruler and hence can be used to map the expansion history of the universe. We use high force resolution simulations to analyze the effects of galaxy bias on the measurements of the BAO signal. We apply a variety of Halo Occupation Distributions (HODs) and produce biased mass tracers to mimic different galaxy populations. We investigate whether galaxy bias changes the nonlinear shifts on the acoustic scale relative to the underlying dark matter distribution presented by Seo et al. For the less biased HOD models (b < 3), we do not detect any shift in the acoustic scale relative to the no-bias case, typically 0.10% {+-} 0.10%. However, the most biased HOD models (b > 3) show a shift at moderate significance (0.79% {+-} 0.31% for the most extreme case). We test the one-step reconstruction technique introduced by Eisenstein et al. in the case of realistic galaxy bias and shot noise. The reconstruction scheme increases the correlation between the initial and final (z = 1) density fields, achieving an equivalent level of correlation at nearly twice the wavenumber after reconstruction. Reconstruction reduces the shifts and errors on the shifts. We find that after reconstruction the shifts from the galaxy cases and the dark matter case are consistent with each other and with no shift. The 1{sigma} systematic errors on the distance measurements inferred from our BAO measurements with various HODs after reconstruction are about 0.07%-0.15%.

79 ASTRONOMY AND ASTROPHYSICS↗

Polarization options in inclusive DIS off tensor polarized deuteron

In the near future, the Jefferson Lab b 1 experiment will provide the second measurement of tensor polarized asymmetries in inclusive DIS on the deuteron. In this asymmetry, 4 independent tensor polarized structure functions contribute. This necessitates systematic approximations in the extraction of the leading twist structure function b 1 from a single tensor asymmetry measurement. Contamination from higher twist structure functions and kinematic effects is discussed here. Using a deuteron convolution model, we quantify the systematic errors from these approximations for two different choices for the target polarization direction (momentum transfer, electron beam direction). For Jefferson Lab 12 GeV kinematics, the systematic error turns out to be comparable between the two polarization options, while at higher Q 2 values the momentum transfer direction is preferred.

Cosyn, Wim [Florida International University, Miam↗