Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Altitude Effects on Thermal Ice Protection System Performance; a Study of an Alternative Approach

Research has been conducted to better understand the phenomena involved during operation of an aircraft's thermal ice protection system under running wet icing conditions. In such situations, supercooled water striking a thermally ice-protected surface does not fully evaporate but runs aft to a location where it freezes. The effects of altitude, in terms of air pressure and density, on the processes involved were of particular interest. Initial study results showed that the altitude effects on heat energy transfer were accurately modeled using existing methods, but water mass transport was not. Based upon those results, a new method to account for altitude effects on thermal ice protection system operation was proposed. The method employs a two-step process where heat energy and mass transport are sequentially matched, linked by matched surface temperatures. While not providing exact matching of heat and mass transport to reference conditions, the method produces a better simulation than other methods. Moreover, it does not rely on the application of empirical correction factors, but instead relies on the straightforward application of the primary physics involved. This report describes the method, shows results of testing the method, and discusses its limitations.

ice protection system performance↗

Reassessment of PHDS Fulcrum40h High Purity Germanium (HPGe) Detector System Performance

This report presents a comprehensive evaluation of the updated PHDS Fulcrum40h High Purity Germanium (HPGe) detector system, benchmarking its performance, usability, and software capabilities against the current National Nuclear Security Administration (NNSA) Nuclear Emergency Support Team (NEST) HPGe Detector System Requirements Document. Systematic measurements were conducted using a single Fulcrum40h detector to assess key parameters including gamma efficiency and resolution, neutron detection efficiency, gamma pulse-pileup response, and gamma-to-neutron crosstalk. The Fulcrum40h system, acquired in August 2022, has undergone recent updates by PHDS to address deficiencies identified following the initial NEST requirements release. The results provide critical insights into the detector’s operational capabilities and compliance with NNSA NEST standards.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solar energy system performance evaluation: Seasonal report for Contemporary Newman, Newman, Georgia

A hot solar heating and hot water system's operational performance from June 1979 through April 1980 is evaluated. Solar energy satisfied 42 percent of the total measure load (hot water plus space heating), which was somewhat higher than the solar fraction of 32 percent. When system losses into the heating space from duct leaks and storage are included, the heating solar fraction increases from 42 to 64 percent. Net electrical energy savings were 5.47 million BTUs.

Source record↗

TSIS-1 Pointing System Performance after 5 Years on ISS

The Total and Spectral Solar Irradiance Sensor-1 (TSIS-1) was installed on the ISS in December 2017, completed its prime 5-year mission in 2023, and is now in extended operations. Within the first year of operations, the paper titled, “Challenges and Solutions for Precision Solar Pointing on the ISS for the TSIS Instrument” was presented at the 2019 IEEE Aerospace Conference. This paper described challenges associated with ISS jitter and structural obscuration along with on-orbit measurements of these phenomenon and how TSIS-1 initially performed in their presence. Since the paper was presented in 2019, TSIS-1 has continued to operate with much success. This paper will provide a 5-year update on the performance of the TSIS-1 pointing system, including additional measurements of ISS base motion jitter, updated ISS obscuration information, data trends that showed slight increases in azimuth motor torque and pointing errors, and a pointing anomaly due to contamination on one of the pointing system sun sensors. These results may help other payload developers better understand the ISS environment and long-term mechanism performance.

Patrick Brown↗

SERT 2 1979 extended flight thruster system performance

Steady state tests of the thruster 2 system on the SERT 2 spacecraft are presented. A direct thrust measurement was obtained for the ion thruster during operations to increase the spacecraft spin rate to maintain spacecraft attitude stability. The continued restart tests of thruster 1 and a report on the general status of all spacecraft systems including the main solar array are presented.

Kerslake, W. R.↗

Testing the Effects of Helium Pressurant on Thermodynamic Vent System Performance with Liquid Hydrogen

In support of the development of a zero gravity pressure control capability for liquid hydrogen, testing was conducted at the Marshall Space Flight Center using the Multipurpose Hydrogen Test Bed (MHTB) to evaluate the effects of helium pressurant on the performance of a spray bar thermodynamic vent system (TVS). Fourteen days of testing was performed in August - September 2005, with an ambient heat leak of about 70-80 watts and tank fill levels of 90%, 50%, and 25%. The TVS successfully controlled the tank pressure within a +/- 3.45 kPa (+/- 0.5 psi) band with various helium concentration levels in the ullage. Relative to pressure control with an "all hydrogen" ullage, the helium presence resulted in 10 to 30 per cent longer pressure reduction durations, depending on the fill level, during the mixing/venting phase of the control cycle. Additionally, the automated control cycle was based on mixing alone for pressure reduction until the pressure versus time slope became positive, at which time the Joule-Thomson vent was opened. Testing was also conducted to evaluate thermodynamic venting without the mixer operating, first with liquid then with vapor at the recirculation line inlet. Although ullage stratification was present, the ullage pressure was successfully controlled without the mixer operating. Thus, if vapor surrounded the pump inlet in a reduced gravity situation, the ullage pressure can still be controlled by venting through the TVS Joule Thomson valve and heat exchanger. It was evident that the spray bar configuration, which extends almost the entire length of the tank, enabled significant thermal energy removal from the ullage even without the mixer operating. Details regarding the test setup and procedures are presented in the paper. 1

Flachbart, R. H.↗

X-31 high angle of attack control system performance

The design goals for the X-31 flight control system were: (1) level 1 handling qualities during post-stall maneuvering (30 to 70 degrees angle-of-attack); (2) thrust vectoring to enhance performance across the flight envelope; and (3) adequate pitch-down authority at high angle-of-attack. Additional performance goals are discussed. A description of the flight control system is presented, highlighting flight control system features in the pitch and roll axes and X-31 thrust vectoring characteristics. The high angle-of-attack envelope clearance approach will be described, including a brief explanation of analysis techniques and tools. Also, problems encountered during envelope expansion will be discussed. This presentation emphasizes control system solutions to problems encountered in envelope expansion. An essentially 'care free' envelope was cleared for the close-in-combat demonstrator phase. High angle-of-attack flying qualities maneuvers are currently being flown and evaluated. These results are compared with pilot opinions expressed during the close-in-combat program and with results obtained from the F-18 HARV for identical maneuvers. The status and preliminary results of these tests are discussed.

Huber, Peter↗

Contamination effects on Space Station Freedom electric power system performance

One design issue for Space Station Freedom (SSF) is the potential performance decrease of the electric power system (EPS) solar arrays and radiators as a result of contamination on sensitive surfaces. The authors discuss SSF potential contamination sources and contamination effects on the solar array and radiator performance due to these sources. With these contamination consideration, the SSF EPS is designed for the induced contamination environment at an optimal cost. The efforts on contamination protection and control are undergoing continual update because of the changes in the SSF configuration and in the contamination requirements, and observations from recent flight and laboratory test data are continuously being incorporated into the design.

Lu, Cheng-Yi↗

Balloon Support Systems Performance for the Cosmic Rays Energetics and Mass Mission

The Ballooncraft Support Systems were developed by NASA Wallops Flight Facility for use on ULDB class balloon missions. The support systems have now flown two missions supporting the Cosmic Rays Energetics and Mass (CREAM) experiment. The first, CREAM I, flown in December 2004, was for a record breaking 41 days, 21 hours, and the second, flown in December 2005, was for 28 days, 9 hours. These support systems provide CREAM with power, telecommunications, command and data handling ioc!uding Plight computers, mechanical structures, thermal management and attitude control to help ensure a successful scientific mission. This paper will address the performance and success of these support systems over the two missions.

Tompson, Linda D.↗

Analysis of the Artemis I Orion Spacecraft Power System Performance

NASA successfully completed an uncrewed test flight of the Orion spacecraft during the 26-day Artemis I mission in November and December 2022. The Artemis I mission profile included several potentially stressing features for Orion electrical power system (EPS) performance, including eclipse duration, multiple propulsive or navigational maneuvers which constrained positioning of the solar array wings (SAWs), and the proximity and phasing of various events together. All of these features vary significantly with Earth-sun-moon geometry, providing a unique challenge for predicting EPS performance before an exact launch date is known. This presentation will provide a brief mission overview, discuss the different computer models with varying levels of fidelity used to analyze Orion EPS performance, as well as the screening process developed to incorporate EPS performance as a consideration for launch epoch selection. Final preflight model predictions of EPS performance will be compared to in-flight telemetry measurements, and several EPS anomalies observed will be briefly discussed.

Orion↗

Masking of photovoltaic system performance problems by inverter clipping and other design and operational practices

We describe how performance problems can be “masked,” or not readily evident by several causes: by photovoltaic (PV) system configuration (such as the size of the PV array capacity relative to the size of the inverter and the resultant clipped operating mode); by instrumentation design, installation, and maintenance (such as a misaligned or dirty pyranometer); by contract clauses (when operational availability is transformed to contractual availability, which excludes many factors); and by identified management and operational practices (such as reporting on a portfolio of plants rather than individually). A simple method based on a duration curve is introduced to overcome shortcomings of Performance Ratio based on nameplate capacity and Performance Index based on hourly simulation when quantifying masking effects, and inverter clipping and pyranometer soiling are presented as two examples of the new method. With a better understanding of the non-transparency of masking issues, stakeholders can better interpret performance data and deliver improved AC and DC plant conditions through PV system operation and maintenance (O&M) for improved performance, reduced O&M costs, and a more consistently delivered, and reduced, levelized cost of energy (LCOE).

14 SOLAR ENERGY↗

Solar cooling system performance, Frenchman's Reef Hotel, Virgin Islands

The operational and thermal performance of a variety of solar systems are described. The Solar Cooling System was installed in a hotel at St. Thomas, U. S. Virgin Islands. The system consists of the evacuated glass tube collectors, two 2500 gallon tanks, pumps, computerized controller, a large solar optimized industrial sized lithium bromide absorption chiller, and associated plumbing. Solar heated water is pumped through the system to the designed public areas such as lobby, lounges, restaurant and hallways. Auxiliary heat is provided by steam and a heat exchanger to supplement the solar heat.

Harber, H.↗

Evaluation of fault-tolerant system performance by approximate techniques

An approximate method for calculating the statistics of the performance of a fault-tolerant system is developed. An approximate method is necessary because the statistical model of the system behavior is large-scale and the time horizon of interest encompasses many cycles of the Redundancy Management logic. In the development, a compact representation of the necessary information called the v-transform is introduced and discussed. Based upon this representation, an approximation that leads to a very efficient computational procedure is suggested and numerically analyzed. A very brief discussion of other related work is also presented.

Walker, B. K.↗

Uniform task level definitions for robotic system performance comparisons

A series of ten task levels of increasing difficulty was compiled for use in comparative performance evaluations of available and future robotics technology. Each level has a breakdown of ten additional levels of difficulty to provide a layering of 100 levels. It is assumed that each level of task performance must be achieved by the system before it can be appropriately considered for the next level.

Price, Charles↗

Statistical assessment of speech system performance

Methods for the normalization of performance tests results of speech recognition systems are presented. Technological accomplishments in speech recognition systems, as well as planned research activities are described.

Moshier, Stephen L.↗