Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system flexibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Simulations of Positron Capture at Ce+BAF

We present a capture concept for the continuous wave (CW) polarized positron injector for the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab (Ce+BAF). This two-step concept is based on (1) the generation of bremsstrahlung radiation by a longitudinally polarized electron beam 1 mA, 120 MeV, 90% polarization), passing through a tungsten target, and (2) the production of e+e--pairs by these bremsstrahlung photons in the same target. To provide highly-polarized positron beams (>60% polarization) or high-current positron beams (>1 µA) with low polarization for nuclear physics experiments, the positron source requires a flexible capture system with an adjustable energy selection band. The results of beam dynamics simulations and calculations of the power deposited in the positron capture section are presented.

Ushakov, Andriy↗

Integration of Large-Scale Renewable Energy in the Bulk Power System: Lessons from International Experiences

Deployment of increasing amounts of renewable energy (RE) presents certain challenges in reliably integrating larger quantities RE into existing bulk power system infrastructures. RE Bulk power typically refers to large-scale power generation at a centralized facility and in the context of RE can include wind farms, utility-scale solar, geothermal, hydro and biomass facilities. Based on international experiences, several actions and related good practices have emerged to support the deployment of RE in the bulk power system. This paper provides a review of emerging international best practices that support the integration of large-scale RE; examples of country-level efforts in implementing these practices; and key considerations for any country pursuing bulk power sector transformation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Improvement of Closures and Mechanistic Limit Modeling in Sockeye

Several improvements were made to the heat pipe application Sockeye, including implementation of closure relations and a second-order spatial discretization. The closures improvements include a new, flexible closures system, interfacial heat transfer coefficients, wall heat transfer coefficients, vapor pressure drop, and liquid pressure drop. These improvements were tested on three test cases, with results compared to analytic solutions and the legacy heat pipe code HTPIPE.

97 MATHEMATICS AND COMPUTING↗

Simulations of Positron Capture at Ce+BAF

We present a capture concept for the continuous wave (CW) polarized positron injector for the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab (Ce+BAF). This two-step concept is based on (1) the generation of bremsstrahlung radiation by a longitudinally polarized electron beam 1 mA, 120 MeV, 90% polarization), passing through a tungsten target, and (2) the production of e+e--pairs by these bremsstrahlung photons in the same target. To provide highly-polarized positron beams (>60% polarization) or high-current positron beams (>1 µA) with low polarization for nuclear physics experiments, the positron source requires a flexible capture system with an adjustable energy selection band. The results of beam dynamics simulations and calculations of the power deposited in the positron capture section are presented.

Ushakov, Andriy↗

Hydroelectric Power and Hydrogen Production Integration

Hydropower-based hydrogen production could introduce opportunities for new revenue streams for hydropower plants, including from energy storage and regeneration as well as from sale of the hydrogen product to external markets. Hydrogen-based energy storage and regeneration could also help support Idaho Power’s decarbonization goals by decreasing dependence on fossil-based peaking power plants. Additionally, integration of hydrogen production with hydropower generation could help address the issue of low dissolved oxygen river water conditions that commonly accompany hydropower plant operations by utilizing the oxygen byproduct from an electrolytic hydrogen production process as a resource for mitigation of low dissolved oxygen water conditions. Comprehensive techno-economic analysis of the hybrid hydroelectric and hydrogen energy storage system has revealed critical insights into the pathways and considerations for optimizing the economic value and environmental benefits of such systems. Among the three identified pathways of natural gas blending, regeneration, and direct sale of hydrogen, the direct sale of hydrogen emerges as the most profitable, particularly given the current pricing dynamics of hydrogen and electricity. However, as we anticipate a future grid characterized by higher renewable energy penetration, the landscape may evolve, featuring lower average electricity prices, heightened fluctuations, and more significant seasonal variations. Consequently, the attractiveness of electricity regeneration through hydrogen and the benefits of long-duration hydrogen storage are expected to increase substantially in such a dynamic energy scenario. The careful selection of component sizes within the hybrid system proves to be paramount for ensuring cost-effectiveness. Notably, the size of the hydrogen market has emerged as a critical determinant for the optimal size of the electrolyzer. Hydrogen storage should be sized to meet energy shifting requirements. The appropriate size of the fuel cell/microturbine generator hinges on the shape of electricity prices and the available revenue streams derived from participating in grid services. Striking the right balance among these components is essential for maximizing the overall efficiency and profitability of the hydrogen facility. Furthermore, the by-product of electrolysis, namely oxygen, introduces an additional dimension to the system's functionality. The oxygen generated can be effectively utilized for dissolved oxygen (DO) mitigation, particularly with larger electrolyzer sizes capable of satisfying the complete oxygen demand for this purpose. While the economic benefits derived from saved oxygen purchase costs may be relatively modest compared to other revenue streams, the environmental advantages of repurposing oxygen for DO mitigation could help Idaho Power meet their environmental obligations. In addition to the identified factors shaping the viability of hybrid hydrogen production and hydroelectric generation, it is noteworthy that the integration of hydrogen energy storage offers a unique advantage during unusually wet years. In such periods of increased water inflow, the hydrogen storage capacity serves as a valuable supplement to the reservoir. By utilizing hydrogen energy storage as a complementary reservoir, the system gains flexibility in reservoir management when dealing with fluctuations in water availability.

08 HYDROGEN↗

Innovations in Direct Air Capture: Unveiling a Simple and Robust Synthesized Fibrous Amine-functionalized Matrix (FAM) Sorbent for Commercial Scale-up

The escalating challenge of climate change necessitates innovative solutions in the realm of carbon management, particularly in mitigating the impact of fossil fuel emissions. Direct Air Capture (DAC) technology emerged as a critical component within the spectrum of Carbon Capture and Sequestration (CCS) solutions, offering the distinct advantage of directly removing CO2 from the atmosphere irrespective of the source. This attribute grants DAC systems unparalleled flexibility in deployment locations and the potential to make substantial contributions to lowing atmospheric CO2 levels. The success of DAC technologies significantly depends on the development of an efficient, economical sorbent capable of selective and durable CO2 capture from ambient air. Recent advancements in material science have led to the exploration of amine-functionalized sorbents, hollow fiber sorbents and membranes, and other novel materials designed to meet these criteria. This study explores a novel Fibrous Amine-functionalized Matrix (FAM) sorbent. The FAM sorbent distinguished itself through its mechanical robustness, a streamlined synthesis process, and the capability for low-temperature regeneration (is 90 oC really low temperature?). FAM’s exceptional adsorption-desorption kinetics enable swift CO2 capture and release, crucial for the viability of DAC on a commercial scale. The synthesis process involves a simple dip-coating technique, allowing crosslinked amines to coat glass substrates.

Wang, Qiuming↗

Advancements in Direct Air Capture: Unveiling a Simple and Robust Synthesized Fibrous Amine-functionalized Matrix (FAM) Sorbent for Commercial Scale-up

The escalating challenge of climate change necessitates innovative solutions in the realm of carbon management, particularly in mitigating the impact of fossil fuel emissions. Direct Air Capture (DAC) technology emerges as a critical component within the spectrum of Carbon Capture and Sequestration (CCS) solutions, offering the distinct advantage of directly removing CO2 from the atmosphere irrespective of the source. This attribute grants DAC systems unparalleled flexibility in deployment location sand the potential to make substantial contributions to lowing atmospheric CO2 levels. The success of DAC technologies significantly depends on the development of efficient, economical sorbent capable of selective and durable CO2 capture from ambient air. Recent advancements in material science have led to the exploration of amine-functionalized sorbents, hollow fiber sorbents and membranes, and other novel materials designed to meet these criteria. This study introduces a significant advancement in DAC technology with the development of a Fibrous Amine-functionalized Matrix (FAM) sorbent. The FAM sorbent distinguished itself through its mechanical robustness, a streamlined synthesis process, and the capability for low-temperature regeneration. Its exceptional adsorption-desorption kinetics enable swift CO2 capture and release, crucial for the viability of DAC on a commercial scale.

Wang, Qiuming↗

Dual-loop Solvent-based CCS for Net Negative CO 2 Emissions with Lower Cost

This final technical report details the successful design, construction, and operational validation of an innovative dual-loop CO 2 capture technology designed to achieve deep decarbonization (>99%) from Natural Gas Combined Cycle (NGCC) power plants that results in the electricity with carbon intensity of approximate 42 kg CO 2 -eq/MWh, less than the electricity produced by solar PV. The integrated process couples a primary aqueous solvent (in this project, a water lean solvent – WLS) absorption loop for bulk CO 2 removal with a secondary potassium hydroxide (KOH) polishing loop featuring electrochemical regeneration. This architecture leverages the higher exergy efficiency of the primary loop while utilizing the fastest kinetic of the secondary loop to capture dilute residual CO 2 , achieving an overall capture rate of 99.9% and co-producing pure hydrogen after moisture being condensed and dehydrated. Technical feasibility was established through a comprehensive 2,000-hour experimental campaign on a bench-scale fully-integrated unit (using 4” absorber and 4” stripper) with the feeding flue gas flowrate in the range of 8-20 cfm, confirming the attainment of Technology Readiness Level (TRL) 4. The project executed extensive parametric testing followed by 1,000 hours of continuous steady-state testing, demonstrating exceptional process stability with the electrochemical regenerator exhibiting less than a 10% reduction in electrical conductivity over the duration of the campaign. Operational characterization gathering on the bench unit revealed distinct energy profiles for the hybrid system: the primary loop required approximately 280 kJ mol -1 for bulk removal, while the polishing loop required approximately 1,600 kJ mol -1 specifically when reducing dilute CO 2 concentrations from ~740 ppm down to <50 ppm. (Please note those energy values/numbers can only be viewed as relative relationship and should not be extrapolated as absolute values required for CO 2 capture). Furthermore, dynamic testing validated the system’s flexibility for utility applications, demonstrating a rapid process response time of <30 minutes to changes in flue gas flowrate. Emission monitoring confirmed that the dual-loop architecture effectively mitigates solvent losses, utilizing a water wash to remove entrained aerosols to <1 ppm. The Techno-Economic Analysis (TEA) indicates a cost of capture of $\$$59.3/tonne and a Levelized Cost of Electricity (LCOE) of 71.7 $\$$/MWh at the overall capture efficiency of 99.8% of total carbon in the flue gas stream, with sensitivity analysis identifying an economic optimum when the primary loop captures 97% of the total CO 2 . A Life Cycle Assessment (LCA) confirms the technology’s potential for net-negative emissions, determining a Global Warming Potential (GWP) of 52 kg CO 2 -eq/MWh—significantly lower than the baseline—which further decreases to 42 kg CO 2 -eq/MWh when crediting the displacement of conventional hydrogen production.

03 NATURAL GAS↗

Storage Futures Study: Four Phases Framework and Modeling

This webinar, presented by Paul Denholm and Will Frazier, incorporates material from two publications of the NREL Storage Futures Study: "The Four Phases of Storage Deployment: A Framework for the Expanding Role of Storage in the U.S. Power System" (https://www.nrel.gov/docs/fy21osti/77480.pdf) and "Storage Futures Study: Economic Potential of Diurnal Storage in the U.S. Power Sector" (https://www.nrel.gov/docs/fy21osti/77449.pdf).

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Flexible optimized data handling in systems with multiple memories

Methods and systems for optimizing an application for a computing system having multiple distinct memory locations that are interconnected by one or more communication channels include determining one or more data handling properties for a data region in an application. One or more data handling policies for the data region are determined based on the one or more data handling properties. Data setup costs are determined for a scope in the application that uses the data region in different memory locations based on the one or more data handling properties. The application is optimized in accordance with the one or more data handling policies and the data setup costs for the different memory locations.

Chen, Tong↗

Effects of Hydrogen Bonding on Nuclear Data Development of Liquid Anhydrous HF

Anhydrous Hydrogen Fluoride (HF) at high temperatures and pressures is used to process and manufacture nuclear fuel. As HF is often used directly with uranium, correct neutron thermal scattering cross sections are crucial to criticality safety applications. Classical molecular dynamics (CMD) simulation of the flexible HF system was used to create the thermal scattering law (TSL) and cross sections. The initial 2-site model is used in LAMMPS, and it can not capture the H-bond. To correctly represent the H-bond effects, a second, 3-site model was constructed in GROMACS. The 3-site model handled H-bonds by connecting a massless charge to the molecule. Key model parameters were compared to experimental data to verify the approach and models. To get the normalized VACF, the model was compared using hydrogen and fluorine bond length, density, potential energy, and diffusion coefficient. The phonon DOSs for both models were derived from the normalized VACF. DOSs were used to estimate the TSL ( S ( α, β )) and neutron thermal scattering cross sections for hydrogen in HF. The TSLs were evaluated using the FLASSH code with the Schofield diffusion model. It was observed that the representation of the hydrogen bonding changes the TSL's diffusional contributions. This is represented in the low energy scattering cross section, where intermolecular binding effects shift the cross section.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Flexible optimized data handling in systems with multiple memories

Methods and systems for optimizing an application for a computing system having multiple distinct memory locations that are interconnected by one or more communication channels include determining one or more data handling properties for a data region in an application. One or more data handling policies for the data region are determined based on the one or more data handling properties. Data setup costs are determined for a scope in the application that uses the data region in different memory locations based on the one or more data handling properties. The application is optimized in accordance with the one or more data handling policies and the data setup costs for the different memory locations.

Chen, Tong↗

Undulating transducer for energy harnessing and propulsion apparatuses, methods and systems

Embodiments disclosed may serve the function of a pump, a generator, or a propulsion system. Two flexible fins are coupled via their longitudinal inner edges to fin coupling modules. An external fluid flow causes traveling fin undulations. The angle of the fins relative to each other changes as undulations travel along the fins which can be translated through the fin coupling modules into mechanical work, powered by the external fluid flow. The mechanical work of the fin coupling modules may be the cyclical extension and contraction of pistons or bellows incorporated into the fin coupling modules, which may draw ambient fluid during their extension cycles and compress fluid during their contraction cycles to create a pump. The pistons or bellows may also be sealed from ambient fluid but connected through conduits through which contained fluid is exchanged in a continuous circulation of fluid to power a pump or a turbine.

Filardo, Benjamin Pietro↗

Laser-system model for enhanced operational performance and flexibility on OMEGA EP

The development of laser performance models having real-time prediction capability for the OMEGA EP laser system has been essential in meeting requests from its user community for increasingly complex pulse shapes that span a wide range of energies. The laser operations model PSOPS provides rapid and accurate predictions of OMEGA EP laser-system performance in both forward and backward directions, a user-friendly interface and rapid optimization capability between shots. We describe the model’s features and show how PSOPS has allowed real-time optimization of the laser-system configuration in order to satisfy the demands of rapidly evolving experimental campaign needs. We also discuss several enhancements to laser-system performance accuracy and flexibility enabled by PSOPS.

42 ENGINEERING↗

Anomaly Detection and Mitigation in FACTS-based Wide-Area Voltage Control Systems using Machine Learning

With the increasing deployment of Flexible AC Transmission System (FACTS) devices in wide-area voltage control systems (WAVCS) for achieving improved voltage stability of bulk power systems, the possibility for cyber attacks on these systems is also increasing. Successful stealthy cyber attacks that are difficult to detect by traditional informational technology (IT)-based cybersecurity solutions or threshold-based bad data detectors can lead to a voltage collapse in power grid. This paper presents the testbed-based attacks implementation and real-time evaluation of machine learning (ML) algorithm for detecting and mitigating stealthy cyber attacks on FACTS-based WAVCS on a hardware-in-the-loop (HIL) testbed. Initially, we discuss the implementation of a fuzzy logic controller (FLC) that controls a Static VAR Compensator (SVC) device deployed in a two-area four-machine Kundur power system for improving transient voltage stability. Later, the ML-based Anomaly Detection and Mitigation (ADM) system is implemented on the cyber-physical HIL testbed to detect and mitigate various stealthy cyber attacks, which are injected in real-time over the wide-area network (WAN). The experimental results show accurate and effective performance of ADM system in detecting and mitigating anomalies while keeping the grid stable and within the system operating limits, as defined by the North America Electric Reliability Corporation (NERC).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integration of a grey-box refrigerated case model in EnergyPlus via Python plugin

Commercial buildings, in particular grocery stores (due mainly to their large refrigeration load), provide opportunities for energy cost reductions. Grocery stores could offer substantial load flexibility to the power grid through participation in demand response programs because of their usage patterns and relatively high energy intensity. This load flexibility could come from modifying the control of heating, ventilation, and air conditioning (HVAC) systems, refrigeration systems, or both. Although estimation of the HVAC system’s load flexibility potential is relatively targeted in the literature, estimating load flexibility of refrigeration systems is nascent and has been a challenge, in part because of the lack of proper simulation tools that capture the dynamics in the refrigeration cases. The existing refrigerated case model within EnergyPlus, a whole building energy simulation program, assumes a constant case temperature throughout the simulation period and does not explicitly model the cycling of the compressor serving the refrigerated case. In addition, it does not encompass modeling of temperatures of the product inside the refrigerated case. This difference between modeled and actual operation can be a barrier to the development of demand control algorithm and accurate analysis of load flexibility potential. In this paper, we present a grey-box model for modeling refrigerated cases in grocery stores, which include medium temperature and low temperature. Four cases are modeled; two are low-temperature closed cases and two are medium-temperature cases with one closed and one open. Data from an experimental facility are used to train and test the models. Results demonstrate the efficacy of the grey-box models in predicting the temperatures. This model is integrated into EnergyPlus to capture the dynamic effects of case temperature on the environment and enhance the calculation of sensible and latent heat exchange with the environment (case credits). These enhancements can be leveraged more broadly to model advanced refrigeration controls such as defrost, develop and test unique algorithms that could affect refrigeration interactions with HVAC, and refine store design for any commercial building with refrigeration.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Providing Ancillary Services with Photovoltaic Generation in Multi-Timescale Grid Operation: Preprint

With photovoltaic (PV) generation substantially increases, electric power systems need more flexible resources that can provide ancillary services to mitigate the variability and uncertainty of the PV generation. On the one hand, the increase of PV generation necessitates the needs of more flexible resources. On the other hand, PV generation, because of its low operation cost, has been replacing the conventional generation in the system which is the main flexible resources in the current system. Consequently, there is a trend to require the renewable generation including PV to provide flexible ancillary services to further accommodate more PV integration. This paper proposes a multi-timescale grid operation model considering the various control strategies of PV providing different ancillary services. Numerical case studies demonstrate that with PV providing both regulation reserve and primary frequency reserve, the system operating costs and PV curtailment will be reduced significantly. It shows that not only the system reliability but also PV's profitability can be improved with PV providing more ancillary services.

41 EE - Solar Energy Technologies Office (EE-4S)↗