Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “synchrotron tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

3d Crystallographic Orientation of Olivine in Bjurböle Chondrules

The crystallographic orientations of chondrule minerals can provide important insights into their formation and deformational history. For example, the orientations of the olivine bars and surrounding rim in barred olivine chondrules provide information and on the conditions of crystallization and the orientations and shapes of olivines within porphritic chondrules can record the reactions with the surrounding nebular gas during chondrule formation. Later deformation on the parent body can cause crystal-plastic deformation of chondrule minerals that is evident through their intracrystalline lattice misorientations. Typically these crystal orientations and lattice misorientations are determined using electron backscatter diffraction (EBSD) on thin sections but this gives only a 2D picture for what is actually a 3D texture. While it is possible to combine EBSD with serial sectioning to build a 3D dataset of texture, this is a destructive, time-intensive process. A recent technological development that enables non-destructive, 3D crystallographic orientation measurement is X-ray diffraction contrast tomography (DCT), which uses the X-ray diffraction of the crystal lattice to determine orientation. Originally only possible using monochromatic X-ray beams at 3rd generation synchrotron light sources, DCT has been recently adapted to polychromatic sources of laboratory X-ray microscopes (referred to as Lab-DCT). Up to this point LabDCT has only been applied to large, well-formed crystals of high symmetry (i.e., metals), but we recently acquired DCT datasets for a pair Bjurböle chondrules to determine the applicability of the technique to natural, mutlimineralic samples composed predominately of olivine (i.e., chondrules).

Hanna, R. D.↗

Endophyte-Promoted Phosphorus Solubilization in Populus

Phosphorus is an important plant nutrient, but in soils the majority of phosphorus, present in the form of a phosphate, forms metal complexes in soil making it relatively unavailable to plants. Therefore, inorganic phosphate solubilization is an important process of plant growth promotion by plant associated bacteria and fungi. Non nodulating plant species have been shown to thrive in low-nutrient environments, in some instances by relying on plant associated microorganisms called endophytes. These microorganisms live within the plant and help supply nutrients for the plant. Despite their potential enormous environmental importance, there are a limited number of studies looking at the direct molecular impact of phosphate solubilizing endophytic bacteria on the host plant. In this work, we studied the impact of two endophyte strains of wild poplar (Populus trichocarpa) that solubilize phosphate. Using a combination of x-ray imaging, spectroscopy methods, and proteomics we report direct evidence of endophyte-promoted phosphorus uptake in poplar. We found that the solubilized phosphate inside the plant may react and become insoluble again suggesting that the phosphate could be re-released within the plant by endophytes. Using synchrotron x-ray fluorescence spectromicroscopy combined with x-ray absorption near-edge structure, we visualized the nutrient phosphorus inside poplar roots inoculated by the selected endophytes and found the phosphorus in both forms of organic and inorganic phosphates inside the root. Tomography-based root imaging revealed a markedly different root biomass and root architecture for poplar samples inoculated with the phosphate solubilizing bacteria strains. Proteomics characterization on poplar roots coupled with protein network analysis revealed novel proteins and metabolic pathways with possible involvement in endophyte enriched phosphorus uptake. These findings suggest an important role of endophytes for phosphorus acquisition and provide a deeper understanding of the critical symbiotic associations between poplar and the endophytic bacteria.

36 MATERIALS SCIENCE↗

Impacts of the Conductive Networks on Solid‐State Battery Operation

The micromorphology of composite cathodes is known to play a vital role in determining all-solid-state battery (ASSB) performance. However, much of our current understanding is derived from empirical observations, lacking a deeper mechanistic foundation. The “rocking chair” concept of battery chemistry requires maintaining charge neutrality, emphasizing the necessity of examining electrode micromorphology from the perspective of conductive networks. This study systematically investigates the microscopic electrochemical impacts of conductive network micromorphology by varying the Li + -to-e − channel ratio in cathodes comprising LiNbO 3 -coated LiNi 0.8 Co 0.1 Mn 0.1 O 2 , Li 6 PS 5 Cl, and carbon fibers. Utilizing multiscale synchrotron-based spectro-microscopy, we unravel that unbalanced Li + and e − conducting channels intensify charge polarization within active cathode particles and accelerate their degradation. A further model system with X-ray nano-tomography resolved e − and Li + channels indicates that spatially uniform and well-paired Li + and e − conducting channels are highly desirable as they could promote more uniform lithiation/delithiation, mitigating microscopic electrochemical polarization. Electrode-scale X-ray holotomography analysis reveals that the impact of conductive networks is particle-size-dependent, with smaller cathode particles being more significantly affected. These findings provide mechanistic insights into the interplay between conductive networks and all-solid-state battery operation, laying the groundwork for rational design and optimization of cathode architectures in future solid-state battery technologies.

36 MATERIALS SCIENCE↗

Grazing-incidence X-ray diffraction tomography for characterizing organic thin films

Characterization of thin films is of paramount importance for evaluating material processing outcomes/efficiency as well as establishing structure–property/performance relationships. This article introduces grazing-incidence diffraction tomography (GID tomography), a technique that combines grazing-incidence X-ray scattering and computed tomography to quantitatively determine the dimension and orientation of crystalline domains in thin films without restrictions on the beam coherence, substrate type or film thickness. This computational method extends the capability of synchrotron beamlines by utilizing standard X-ray scattering experiment setups.

36 MATERIALS SCIENCE↗

Rapid grain refinement and compositional homogenization in a cast binary Cu50Ni alloy achieved by friction stir processing

Friction stir processing (FSP) has been increasingly adopted for joining and processing materials in automotive, aerospace and industrial construction. During FSP a dynamic competition between high-speed shear deformation and deformation-induced heating brings about a complex competition between multiple dynamic microstructural evolution mechanisms making it difficult to predict the microstructural evolution pathway. Hence, improved understanding of microstructural evolution mechanisms during FSP can be beneficial for continued growth in the adoption of FSP for demanding applications of future. Towards this goal, this study uses a model binary Cu – 50 at.% Ni alloy to clarify the effect of single and double pass FSP on the microstructural evolution of a coarse grained and compositionally heterogeneous cast microstructure. High energy synchrotron X-ray diffraction, electron backscatter diffraction, and nanoindentation are used to clarify the microstructural evolution due to FSP. The process of compositional homogenization of as-cast segregations is studied by energy dispersive spectroscopy and atom probe tomography. Our results show that a single fast FSP pass at 30 mm.s -1 produces a 100 µm deep layer of submicrometric and hall-petch hardened CuNi grains. The initial cast compositional heterogeneities in a micrometric scale is rapidly transformed to nano-sized domains, mainly confined at grain boundaries. Double pass FSP increases the penetration depth of the processed layer and leads to a 2.9 times grain growth relative to single pass FSP. Grain fragmentation, discontinuous dynamic recrystallization, grain growth, and twinning mechanisms are discussed. In conclusion, these results highlight the value of FSP for ultrafast grain refinement and compositional homogenization of cast alloys.

36 MATERIALS SCIENCE↗

Optical Interference for the Guidance of Cryogenic Focused Ion Beam Milling Beyond the Axial Diffraction Limit

Using a tri-coincident cryogenic FIB-SEM-LM system, we identify an interferometric optical response that can be used for targeting lamella production to fluorescently labelled structures with accuracy beyond the diffraction limit. We demonstrate the approach using synthetic samples of fluorescent beads embedded in micron-scale droplets of water. Here, we then apply the approach to capture virions inside host cells. Successful targeting is confirmed by cryogenic electron tomography revealing clusters of virions in intracellular vesicles.

Sica, Anthony V. [SLAC National Accelerator Labora↗

Unraveling Impurity-Dependent Morphological and Chemical Evolution of Ni–20Cr Alloy in Eutectic LiCl–KCl Molten Salt

Understanding the interfacial evolution of alloys in molten salt with different amounts of water (H 2 O) and oxygen (O 2 ) impurities is significant for applications in many fields, including concentrated solar power, molten salt reactors, and applications in pyrochemical reprocessing and electrorefining. Additionally, the impurity-driven corrosion mechanisms that lead to various morphological and chemical evolution characteristics at the interfaces of structural alloys and molten salts are not fully understood. In the present work, the three-dimensional (3D) morphological evolution of Ni-20Cr microwires in LiCl-KCl was studied at 500 °C under different moisture and oxygen conditions using in situ synchrotron transmission X-ray microscopy (TXM) and scanning transmission electron microscopy (STEM) techniques. No significant morphological changes were observed in Ni-20Cr microwires under vacuum conditions. However, the wires exhibited distinct morphological evolutions when exposed to molten salt containing H 2 O alone, as well as when both H 2 O and O 2 were present. Furthermore, Cr 2 O 3 precipitates were observed in the molten salt during corrosion with only H 2 O present, while Cr 6+ species were identified in the salt when O 2 was added. Further, these findings are crucial for understanding the corrosion mechanisms of molten salt with different amounts of H 2 O and O 2 contamination, providing insights for developing corrosion mitigation methods and improving the stability of containment alloys in molten salt applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

3D and Multimodal X‐Ray Microscopy Reveals the Impact of Voids in CIGS Solar Cells

Small voids in the absorber layer of thin-film solar cells are generally suspected to impair photovoltaic performance. They have been studied on Cu(In,Ga)Se 2 cells with conventional laboratory techniques, albeit limited to surface characterization and often affected by sample-preparation artifacts. Here, synchrotron imaging is performed on a fully operational as-deposited solar cell containing a few tens of voids. By measuring operando current and X-ray excited optical luminescence, the local electrical and optical performance in the proximity of the voids are estimated, and via ptychographic tomography, the depth in the absorber of the voids is quantified. Besides, the complex network of material-deficit structures between the absorber and the top electrode is highlighted. Despite certain local impairments, the massive presence of voids in the absorber suggests they only have a limited detrimental impact on performance.

14 SOLAR ENERGY↗

Bridging Nano- and Microscale X-Ray Tomography for Battery Research by Leveraging Artificial Intelligence

X-ray computed tomography (CT) is a non-destructive imaging technique in which contrast originates from the materials' absorption coefficient. The recent development of laboratory nanoscale CT (nano-CT) systems has pushed the spatial resolution for battery material imaging to voxel sizes of 50 nm, a limit previously achievable only with synchrotron facilities. Given the non-destructive nature of CT, in situ and operando studies have emerged as powerful methods to quantify morphological parameters, such as tortuosity factor, porosity, surface area and volume expansion, during battery operation or cycling. Combined with artificial intelligence and machine learning analysis techniques, nano-CT has enabled the development of predictive models to analyse the impact of the electrode microstructure on cell performances or the influence of material heterogeneities on electrochemical responses. In this Review, we discuss the role of X-ray CT and nano-CT experimentation in the battery field, discuss the incorporation of artificial intelligence and machine learning analyses and provide a perspective on how the combination of multiscale CT imaging techniques can expand the development of predictive multiscale battery behavioural models.

diagnostics↗

PyPhase – a Python package for X-ray phase imaging

X-ray propagation-based imaging techniques are well established at synchrotron radiation and laboratory sources. However, most reconstruction algorithms for such image modalities, also known as phase-retrieval algorithms, have been developed specifically for one instrument by and for experts, making the development and diffusion of such techniques difficult. Here, PyPhase, a free and open-source package for propagation-based near-field phase reconstructions, which is distributed under the CeCILL license, is presented. PyPhase implements some of the most popular phase-retrieval algorithms in a highly modular framework supporting its deployment on large-scale computing facilities. This makes the integration, the development of new phase-retrieval algorithms, and the deployment on different computing infrastructures straightforward. Its capabilities and simplicity are presented by application to data acquired at the synchrotron source MAX IV (Lund, Sweden).

36 MATERIALS SCIENCE↗

A wide-field micro-computed tomography detector: micron resolution at half-centimetre scale

Ideal three-dimensional imaging of complex samples made up of micron-scale structures extending over mm to cm, such as biological tissues, requires both wide field of view and high resolution. For existing optics and detectors used for micro-CT (computed tomography) imaging, sub-micron pixel resolution can only be achieved for fields of view of <2 mm. This article presents a unique detector system with a 6 mm field-of-view image circle and 0.5 µm pixel size that can be used in micro-CT units utilizing both synchrotron and commercial X-ray sources. A resolution-test pattern with linear microstructures and whole adult Daphnia magna were imaged at beamline 8.3.2 of the Berkeley Advanced Light Source. Volumes of 10000 × 10000 × 7096 isotropic 0.5 µm voxels were reconstructed over a 5.0 mm × 3.5 mm field of view. Measurements in the projection domain confirmed a 0.90 µm measured spatial resolution that is largely Nyquist-limited. This unprecedented combination of field of view and resolution dramatically reduces the need for sectional scans and computational stitching for large samples, ultimately offering the means to elucidate changes in tissue and cellular morphology in the context of larger, whole, intact model organisms and specimens. This system is also anticipated to benefit micro-CT imaging in materials science, microelectronics, agricultural science and biomedical engineering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Understanding coarsening of a post-corrosion microstructure in a molten salt by combining phase-field modeling and in situ tomography

Alloys corroding in molten salt have been observed to form bicontinuous, nanoporous microstructures via dealloying, which subsequently undergo coarsening due to facile transport in high-temperature conditions. In this work, we describe a methodology to elucidate the underlying transport mechanisms during coarsening of a bicontinuous microstructure via quantitative comparisons between phase-field simulations and four-dimensional in situ experiments, in this case X-ray nanotomography of the coarsening of a dealloyed 80 wt% Ni-20 wt% Cr microwire in molten KCl-MgCl 2 at 800°C. We conduct phase-field simulations initialized from experimental data to model coarsening via three different transport mechanisms: surface diffusion, solid bulk diffusion, and liquid bulk diffusion. These simulations reproduce key features of the experiment, such as the densification of the outer layer of the dealloyed wire and the reduction in radius over time. We quantitatively compare different microstructural characteristics between the simulations and experiment and extract temporal scaling factors that optimally match the time scales of the simulations to that of the experiment. This allows us to evaluate morphological similarity between the simulations and experiment and relate the experimental coarsening kinetics to fundamental material properties. We find that surface diffusion is most likely to be the dominant coarsening mechanism, and its kinetics imply a surface diffusivity of D S = 8.9 x 10 -20 m 3 /s, which is within the range of reported values for Ni-vacuum interfaces at 800°C. However, the difference between the experiment and the surface diffusion simulation increases substantially at late times, suggesting that other mechanisms, such as the dissolution of residual Cr, may be at play.

36 MATERIALS SCIENCE↗

Laminography as a tool for imaging large-size samples with high resolution

Despite the increased brilliance of the new generation synchrotron sources, there is still a challenge with high-resolution scanning of very thick and absorbing samples, such as a whole mouse brain stained with heavy elements, and, extending further, brains of primates. Samples are typically cut into smaller parts, to ensure a sufficient X-ray transmission, and scanned separately. Compared with the standard tomography setup where the sample would be cut into many pillars, the laminographic geometry operates with slab-shaped sections significantly reducing the number of sample parts to be prepared, the cutting damage and data stitching problems. In this work, a laminography pipeline for imaging large samples (>1 cm) at micrometre resolution is presented. The implementation includes a low-cost instrument setup installed at the 2-BM micro-CT beamline of the Advanced Photon Source. Additionally, sample mounting, scanning techniques, data stitching procedures, a fast reconstruction algorithm with low computational complexity, and accelerated reconstruction on multi-GPU systems for processing large-scale datasets are presented. The applicability of the whole laminography pipeline was demonstrated by imaging four sequential slabs throughout an entire mouse brain sample stained with osmium, in total generating approximately 12 TB of raw data for reconstruction.

47 OTHER INSTRUMENTATION↗

Resolving three-dimensional nanoscale heterogeneities in lithium metal batteries with cryoelectron tomography

Current direct observation of sensitive battery materials and interfaces primarily relies on two-dimensional (2D) imaging, leaving out their three-dimensional (3D) relationship. Here, in this study, we used cryoelectron tomography (cryo-ET) to visualize the lithium metal anode in 3D at nanometer resolution and cryoelectron microscopy (cryo-EM) to reveal atomic details in local regions. We imaged both freshly prepared and calendar-aged Li metal anodes to reveal the development of LiH in Li dendrites and the Li-LiH interface, as well as the development of the solid-electrolyte interphase (SEI). Using a convolutional neural network-based technique, the 3D arrangement of Li metal, along with nanoscale LiH and Cu heterogeneities in dendrites, was visualized and annotated. In longer-term calendar aging, we observed more substantial LiH growth accompanied by extended SEI growth. Our results show that the growth of LiH and the extended SEI during battery calendar aging are temporally and spatially separate processes.

LiH↗

Interior soft x-ray tomography with sparse global sampling

To investigate the feasibility of interior imaging reconstruction in soft X-ray tomography for higher-resolution cellular imaging, including whole-cell imaging, we develop an alignment and reconstruction algorithm that combines a small number of sparse whole-cell images with a high-resolution local interior scan. Based on numerical simulations, we demonstrate that combined reconstructions mitigate the depth-of-field limitation in high-resolution scans, enable radiation dose optimization, and yield quantitative X-ray absorption values with sparse sampling. We further validate our numerical approach using experimental data from two different cell types and show that the combined reconstruction reliably provides high spatial resolution within an interior region of interest of a whole cell. The resulting sparse reconstruction framework offers robust, faithful visualization of cellular organelles in soft X-ray tomography. This mesoscale imaging strategy allows one to ‘scout’ and zoom into selected subcellular volumes of interest, enabling increased spatial resolution without sacrificing larger-volume imaging and providing information on the relative positions of all organelles within a cell.

3D imaging↗

Microstructure and water absorption of ancient concrete from Pompeii: An integrated synchrotron microtomography and neutron radiography characterization

There is renewed interest in using advanced techniques to characterize ancient Roman concrete due to its exceptional durability and low-carbon footprint. In the present work, samples were drilled from the “Hospitium” in Pompeii and were analyzed by synchrotron microtomography (μCT) and neutron radiography to study how the microstructure, including the presence of induced cracks, affects their water adsorption. The water distribution and absorptivity were quantified by neutron radiography. The 3D crack propagation, pore size distribution and orientation, tortuosity, and connectivity were analyzed from μCT results using advanced imaging methods. Porosity was also measured by mercury intrusion porosimetry (MIP) as a reference. Ductile fracture patterns were observed once cracks were introduced. Compared to Portland cement mortar/concrete, the Pompeii samples had relatively high porosity, low connectivity, and a similar coefficient of capillary penetration. In addition, permeability was predicted from models based on percolation theory and pore structure data to evaluate the fluid transport properties. Understanding the microstructure of ancient Pompeii concrete is important because it could inspire the development of modern concrete with high durability.

36 MATERIALS SCIENCE↗

FY26 Progress Report on the Operation of the Activated Materials Laboratory at the Advanced Photon Source as a Nuclear Science User Facilities Partner Facility

The Activated Materials Laboratory (AML), located in the Long Beamline Building of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL), provides a centralized radiological capability for preparing, handling, and supporting synchrotron experiments on activated materials. As a Nuclear Science User Facilities (NSUF) partner facility, the AML enables the receipt of radioactive shipments, open-form sample handling, encapsulation, transport of specimens to and from APS beamlines, and experimentation with dedicated equipment. The partnership includes the APS 1-ID and 20-ID beamlines, which provide high-energy x-ray scattering, tomography, and diffraction microscopy techniques for ex-situ, in-situ, and grainresolved three-dimensional (3D) characterization. All samples supported through the AML and partner beamlines must meet radiological limits of less than 100 mrem/h at 30 cm. This FY26 progress report summarizes the first full year of AML operations as an NSUF partner facility and highlights progress in both user support and capability development. By the end of FY26, the AML had received a total of 10 NSUF-awarded projects, including 2 Consolidated Innovative Nuclear Research (CINR), 7 Rapid Turnaround Experiment (RTE), and 1 Super RTE projects. Beamtime was fully delivered for 3 RTE projects and partially delivered for 1 CINR project, demonstrating successful workflows for receipt, encapsulation, beamline transfer, and radiological experiment execution. These efforts demonstrated safe radiological experiments at APS beamlines for samples with dose rates above the historical 5 mrem/h threshold and now up to 100 mrem/h at 30 cm, marking an important milestone for neutron-irradiated materials research. During FY26, the AML also expanded its experimental capabilities. A Psylotech xTS load frame with in-grip rotation was deployed for room-temperature mechanical testing with threedimensional x-ray characterization during interrupted loading. A Linkam TS1500V vacuum heater was commissioned for thermally driven studies, and temperature calibration experiments were performed to establish specimen-relevant thermal profiles. In parallel, a customized split-tube furnace for high-temperature mechanical testing entered commissioning, and initial work began on robotic sample handling to reduce worker dose and improve operational efficiency. Data workflow and beamline operations continued to mature. Together, these developments demonstrate that the AML is becoming a unique national resource for safe, efficient, and scientifically advanced characterization of activated materials at the APS.

Zhang, Xuan↗