Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “synchronization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Synchronization for CXL Based Memory

Compute Express Link (CXL) is an important emerging standard for disaggregated memory. While this standard provisions coherency across numerous hosts and devices, implementing hardware support for type three devices is challenging. In this work, we look at the overhead of software synchronization and using software-based coherency. Moreover, we discuss the limits of software-based coherency in fully expressing modern synchronization techniques for a CXL-based disaggregate memory system. We demonstrate our approach using a CXL hardware prototype and running a version of the famous Peterson Lock (enhanced to run with more than two threads). We analyze its performance and share how more advanced synchronization techniques might interact with software-based coherence CXL hardware and program execution models.

High Performance Computing (HPC)↗

Synchronization System for Next Generation Light Sources

An alternative synchronization technique – one that would allow explicit control of the pulse train including its repetition rate and delay is clearly desired. We propose such a scheme. Our method is based on optical interferometry and permits synchronization of the pulse trains generated by two independent mode-locked lasers. As the next generation x-ray sources will be driven by a clock signal derived from a mode-locked optical source, our technique will provide a way to synchronize x-ray probe with the optical pump pulses.

43 PARTICLE ACCELERATORS↗

Timing and Synchronization in the LLRF systems of the Fermilab PIP-II Linac

The PIP-II Accelerator is an 800 MeV superconducting Linac in the injection chain of the Fermilab accelerator complex. The LLRF systems for the 125 cavities which include a few normal conducting cavities in the warm front-end section, use a variety of LLRF hardware components and sub-systems that are part of the timing and synchronization system. This includes a master oscillator and phase averaging reference line, a beam pattern generator to enable beam transfer between non-harmonic RF systems and beam loading compensation systems synchronized to a start of beam trigger. The timing signals are based on a 650 MHz clock with manchester encoded event information and data provided over optical fiber. The timing and synchronization systems and their performance parameters will be described here.

Varghese, Philip↗

Synchronous Machine Governor Upgrade

Conventional generation sources play a critical role in the stability and reliability of the electrical grid, particularly as we transition towards more renewable energy sources. To understand and accurately emulate their behavior for optimizing grid operations and ensuring seamless integration with renewable technologies, it is essential to better emulate the grid- and plant-level impacts of conventional generation sources, such as natural gas (NG) driven heat recovery steam generators (HRSGs) and combustion turbines (CTs). Therefore, a governor model is developed in a programmable logic controller (PLC) to investigate the performance of the conventional generator under various dynamic operating conditions and to identify the impact on grid stability in a controlled environment. The governor model aims to enable the hardware-in-the-loop (HIL) based emulation of these conventional generation sources using the existing 2 MVA synchronous machine/generator that is driven by a flexible 2.5 MW variable speed drive. This setup will allow us to replicate the dynamic characteristics and response behaviors of NG-driven HRSGs and CTs. The controls for the emulated conventional plants follow the industry standard and are adjustable, ensuring they accurately reflect the operational capabilities and limitations of real-world systems. These controls include load-following capabilities, ramp rates, startup and shutdown sequences, and emissions characteristics. By incorporating these adjustable controls, we aim to capture the nuanced impacts of conventional generation, such as their ability to provide ancillary services like frequency regulation, voltage support, and spinning reserve. In this report, we simulate two types of dynamic operations: grid-connected and islanding. For each dynamic operation, representative starting sequences are tested, including turbine purge, ignition, speed ramping up, generator excitation and synchronizing, and breaker close. The HIL based tests provides insights for field deployment, specifically the high-fidelity governor model provides results to predict the potential stability and reliability risk and suggest possible integration measures (e.g., generation and load balancing, tuning of governor control parameters). Ultimately, this enhanced emulation capability will be integrated into our Advanced Research on Integrated Energy Systems (ARIES), enabling us to conduct comprehensive studies on the interactions between conventional and renewable energy sources. By better understanding these interactions, we can develop strategies to optimize the overall performance and reliability of the grid. This will support the deployment of advanced grid management techniques, such as demand response, grid-forming inverters, and energy storage systems. The main contributions are summarized as follows: (1) This report introduces a PLC-based governor model for gas turbines. This model accurately simulates the dynamic behavior of conventional generation sources under various operational scenarios; (2) The model is integrated with an HIL testbed that includes a 2.5 MW variable speed drive and a 2 MVA synchronous machine. This setup enables realistic, real-time emulation of conventional power plants, particularly NG driven HRSGs and CTs; (3) The developed model is adaptable to various gas turbine configurations and allows for precise control over parameters such as MW ramp rates. This flexibility makes it a valuable tool for future research and industry collaboration; and (4) By incorporating the model into the National Renewable Energy Laboratory's Advanced Research on Integrated Energy Systems, the report lays the groundwork for future studies on interactions between conventional and renewable energy sources, enhancing the ability to develop advanced grid management strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synchronous Rotation in the (136199) Eris–Dysnomia System

We combine photometry of Eris from a 6 month campaign on the Palomar 60 inch telescope in 2015, a 1 month Hubble Space Telescope WFC3 campaign in 2018, and Dark Energy Survey data spanning 2013–2018 to determine a light curve of definitive period 15.771 ± 0.008 days (1σ formal uncertainties), with nearly sinusoidal shape and peak-to-peak flux variation of 3%. This is consistent at part-per-thousand precision with the P = 15.785 90 ± 0.00005 day sidereal period of Dysnomia's orbit around Eris, strengthening the recent detection of synchronous rotation of Eris by Szakáts et al. with independent data. Photometry from Gaia are consistent with the same light curve. We detect a slope of 0.05 ± 0.01 mag per degree of Eris's brightness with respect to illumination phase averaged across g, V, and r bands, intermediate between Pluto's and Charon's values. Variations of 0.3 mag are detected in Dysnomia's brightness, plausibly consistent with a double-peaked light curve at the synchronous period. The synchronous rotation of Eris is consistent with simple tidal models initiated with a giant-impact origin of the binary, but is difficult to reconcile with gravitational capture of Dysnomia by Eris. The high albedo contrast between Eris and Dysnomia remains unexplained in the giant-impact scenario.

79 ASTRONOMY AND ASTROPHYSICS↗

The Scheme of Beam Synchronization in MEIC

Synchronizing colliding beams at single or multiple collision points is a critical R&D issue in the design of a medium energy electron-ion collider (MEIC) at Jefferson Lab. The path-length variation due to changes in the ion energy, which varies over 20 to 100 GeV, could be more than several times the bunch spacing. The scheme adopted in the present MEIC baseline is centered on varying the number of bunches (i.e., harmonic number) stored in the collider ring. This could provide a set of discrete energies for proton or ions such that the beam synchronization condition is satisfied. To cover the ion energy between these synchronized values, we further propose to vary simultaneously the electron ring circumference and the frequency of the RF systems in both collider rings. We also present in this paper the requirement of frequency tunability of SRF cavities to support the scheme.

43 PARTICLE ACCELERATORS↗

Generation-based memory synchronization in a multiprocessor system with weakly consistent memory accesses

In a multiprocessor system, a central memory synchronization module coordinates memory synchronization requests responsive to memory access requests in flight, a generation counter, and a reclaim pointer. The central module communicates via point-to-point communication. The module includes a global OR reduce tree for each memory access requesting device, for detecting memory access requests in flight. An interface unit is implemented associated with each processor requesting synchronization. The interface unit includes multiple generation completion detectors. The generation count and reclaim pointer do not pass one another.

97 MATHEMATICS AND COMPUTING↗

Method of synchronizing independent functional unit

A system for synchronizing parallel processing of a plurality of functional processing units (FPU), a first FPU and a first program counter to control timing of a first stream of program instructions issued to the first FPU by advancement of the first program counter; a second FPU and a second program counter to control timing of a second stream of program instructions issued to the second FPU by advancement of the second program counter, the first FPU is in communication with a second FPU to synchronize the issuance of a first stream of program instructions to the second stream of program instructions and the second FPU is in communication with the first FPU to synchronize the issuance of the second stream program instructions to the first stream of program instructions.

97 MATHEMATICS AND COMPUTING↗

Method of synchronizing independent functional unit

A system for synchronizing parallel processing of a plurality of functional processing units (FPU), a first FPU and a first program counter to control timing of a first stream of program instructions issued to the first FPU by advancement of the first program counter; a second FPU and a second program counter to control timing of a second stream of program instructions issued to the second FPU by advancement of the second program counter, the first FPU is in communication with a second FPU to synchronize the issuance of a first stream of program instructions to the second stream of program instructions and the second FPU is in communication with the first FPU to synchronize the issuance of the second stream program instructions to the first stream of program instructions.

97 MATHEMATICS AND COMPUTING↗

Generation-based memory synchronization in a multiprocessor system with weakly consistent memory accesses

In a multiprocessor system, a central memory synchronization module coordinates memory synchronization requests responsive to memory access requests in flight, a generation counter, and a reclaim pointer. The central module communicates via point-to-point communication. The module includes a global OR reduce tree for each memory access requesting device, for detecting memory access requests in flight. An interface unit is implemented associated with each processor requesting synchronization. The interface unit includes multiple generation completion detectors. The generation count and reclaim pointer do not pass one another.

97 MATHEMATICS AND COMPUTING↗

Method of synchronizing independent functional unit

A system for synchronizing parallel processing of a plurality of functional processing units (FPU), a first FPU and a first program counter to control timing of a first stream of program instructions issued to the first FPU by advancement of the first program counter; a second FPU and a second program counter to control timing of a second stream of program instructions issued to the second FPU by advancement of the second program counter, the first FPU is in communication with a second FPU to synchronize the issuance of a first stream of program instructions to the second stream of program instructions and the second FPU is in communication with the first FPU to synchronize the issuance of the second stream program instructions to the first stream of program instructions.

97 MATHEMATICS AND COMPUTING↗

Synchronous generator modeling and frequency control using unscented Kalman filter

Various examples are related to synchronous generator modeling with frequency control, which can be achieved using unscented Kalman filtering. In one example, a method includes obtaining operational parameters associated with a generator of a power system; determining parameters of a synchronous generator model with frequency control based at least in part upon the operational parameters associated with the generator; and providing a command to a frequency control of the generator, the command updating one or more parameters of the frequency control. In another example, a system includes a generator controller for a generator of a power system; and a computing device in communication with the generator controller, where the computing device is configured to determine parameters of the synchronous generator model using operational parameters associated with the generator and provide a command updating one or more parameters of a frequency control of the generator controller.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bulk Power System Dynamics with Varying Levels of Synchronous Generators and Grid-Forming Power Inverters: Preprint

Inverters using phase-locked loops for control depend on voltages generated by synchronous machines to operate. This might be problematic if much of the conventional generation fleet is displaced by inverters. To solve this problem, grid-forming control for inverters has been proposed as being capable of autonomously regulating grid voltages and frequency. Presently, the performance of bulk power systems with massive penetrations of grid-forming inverters has not been thoroughly studied to elucidate benefits. Hence, this paper presents inverter models with two grid-forming strategies: virtual oscillator control and droop control. The two models are specifically developed to be used in positive-sequence simulation packages and have been implemented in PSLF. The implementations are used to study the performance of bulk power grids incorporating inverters with grid-forming capability. Specifically, simulations are conducted on a modified IEEE 39-bus test system and the micro-WECC test system with varying levels of synchronous and inverter-based generation. The dynamic performance of the tested systems with grid-forming inverters during contingency events is better than cases with only synchronous generation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sleeve rotor synchronous reluctance electric machine

According to various embodiments, a synchronous reluctance machine is disclosed. The synchronous reluctance machine includes a stator, a synchronous reluctance rotor disposed within the stator and configured to rotate relative to the stator, and a non-magnetic sleeve disposed circumferentially around the rotor, where sleeve thickness is between about 1 mm and 2 mm and an air-gap radius is between about 80 mm and 100 mm.

Reddy, Patel Bhageerath↗

Multiple Laser Tracker Synchronization for the Vibration Analysis

Measuring the mechanical coupling and rigidity of a large apparatus presents unique challenges for 3D metrology. In this case the motion of well separated points attached to a rotor blade must be rapidly and repeatedly measured and the resulting data synchronized. This presentation describes the methodology and results for the mechanical coupling test of the magnetic field mapping system (FMS) for the Mu2e experiment at Fermi National Accelerator Laboratory (Fermilab). Three laser trackers, 2 API Radians and an API TIII, simultaneously measured the position of three cylindrical corner cube reflectors mounted on the FMS while the system was in motion and after coming to rest. The laser trackers took measurements at 83Hz for the T3 and 100Hz for the Radians, with fine spatial resolution, resulting in over 20,000 points measured per instrument in observation cycle. The laser tracker hardware and utilized software are unable to synchronize the three independent data streams directly during the measurement process. Instead a custom software program was developed to perform this synchronization of the data sequences during post-processing using features of the targets motion common to all three fiducial locations.

43 PARTICLE ACCELERATORS↗

QuadSync: Quadrifocal tensor synchronization via Tucker decomposition

In structure from motion, quadrifocal tensors capture more information than their pairwise counterparts (essential matrices), yet they have often been thought of as impractical and only of theoretical interest. In this work, we challenge such beliefs by providing a new framework to recover n cameras from the corresponding collection of quadrifocal tensors. We form the block quadrifocal tensor and show that it admits a Tucker decomposition whose factor matrices are the stacked camera matrices, and which thus has a multilinear rank of (4,4,4,4) independent of n. We develop the first synchronization algorithm for quadrifocal tensors, using Tucker decomposition, alternating direction method of multipliers, and iteratively reweighted least squares. We further establish relationships between the block quadrifocal, trifocal, and bifocal tensors, and introduce an algorithm that jointly synchronizes these three entities. Numerical experiments demonstrate the effectiveness of our methods on modern datasets, indicating the potential and importance of using higher-order information in synchronization.

Miao, Daniel [University of Minnesota]↗

Adaptive vibration control using synchronous demodulation with machine tool controller motor commutation

A control system and method for actively reducing vibration in a spindle housing caused by unbalance forces on a rotating spindle, by measuring the force-induced spindle-housing motion, determining control signals based on synchronous demodulation, and provide compensation for the measured displacement to cancel or otherwise reduce or attenuate the vibration. In particular, the synchronous demodulation technique is performed to recover a measured spindle housing displacement signal related only to the rotation of a machine tool spindle, and consequently rejects measured displacement not related to spindle motion or synchronous to a cycle of revolution. Furthermore, the controller actuates at least one voice-coil (VC) motor, to cancel the original force-induced motion, and adapts the magnitude of voice coil signal until this measured displacement signal is brought to a null. In order to adjust the signal to a null, it must have the correct phase relative to the spindle angle. The feedback phase signal is used to adjust a common (to both outputs) commutation offset register (offset relative to spindle encoder angle) to force the feedback phase signal output to a null. Once both of these feedback signals are null, the system is compensating properly for the spindle-induced motion.

47 OTHER INSTRUMENTATION↗

Permanent Magnet Synchronous Condenser for Wind Power Plant Grid Connection Support: Preprint

A synchronous condenser (SC) using a permanent magnet synchronous generator (PMSG) is proposed for providing necessary reactive power to a wind power plant to support its connection to a weak grid. A PMSG has the advantage of higher efficiency and reliability. Because of its lack of a field winding, a PMSG is typically controlled by a full-power converter, which can be costly. In the proposed system, the reactive power of the SC is controlled by a serially connected compensator operating in a closed-loop configuration. The compensator also damps the PMSG's tendency to oscillate. The compensator's VA rating is only a fraction of the rating of the SC and the PMSG. In this initial investigation, the proposed scheme is shown to be effective by computer simulations.

17 WIND ENERGY↗