High-Resolution Imaging of Supraglacial Hydrological Features on the Greenland Ice Sheet with NASA’s Airborne Topographic Mapper (ATM) Instrument Suite

Seasonal meltwater pools on the surface of the Greenland Ice Sheet (GrIS) during late spring and summer in lakes on the surface and transforms the ice sheet's surface into a wet environment in the ablation zone below the equilibrium line. These supraglacial lakes in topographic lows on the ice surface are connected by a dendritic pattern of meandering streams and channels that together form a hydrological system consisting of supra-, en-, and subglacial components. Here, we use lidar data from NASA's Airborne Topographic Mapper (ATM) instrument suite and high-resolution optical imagery collected as part of Operation IceBridge (OIB) in spring 2019 over the GrIS to develop methods for the study of supraglacial hydrological features. While airborne surveys have a limited temporal and spatial coverage compared to imaging spaceborne sensors, their high footprint density and high-resolution imagery reveal a level of detail that is currently not obtainable from spaceborne measurements. The accuracy and resolution of airborne measurements complement spaceborne measurements, can support calibration and validation of spaceborne methods, and provide information necessary for high-resolution process studies of the supraglacial hydrological system on the GrIS that currently cannot be achieved from spaceborne observations alone.

ATM↗

Composites with improved fiber-resin interfacial adhesion

The adhesion of fiber reinforcement such as high modulus graphite to a matrix resin such as polycarbonate is greatly enhanced by applying a very thin layer, suitably from 50 Angstroms to below 1000 Angstroms, to the surface of the fiber such as by immersing the fiber in a dilute solution of the matrix resin in a volatile solvent followed by draining to remove excess solution and air drying to remove the solvent. The thin layer wets the fiber surface. The very dilute solution of matrix resin is able to impregnate multifilament fibers and the solution evenly flows onto the surface of the fibers. A thin uniform layer is formed on the surface of the fiber after removal of the solvent. The matrix resin coated fiber is completely wetted by the matrix resin during formation of the composite. Increased adhesion of the resin to the fibers is observed at fracture. At least 65 percent of the surface of the graphite fiber is covered with polycarbonate resin at fracture whereas uncoated fibers have very little matrix resin adhering to their surfaces at fracture and epoxy sized graphite fibers exhibit only slightly higher coverage with matrix resin at fracture. Flexural modulus of the composite containing matrix resin coated fibers is increased by 50 percent and flexural strength by 37 percent as compared to composites made with unsized fibers.

Cizmecioglu, Muzaffer↗

Method for forming hermetic seals

The firmly adherent film of bondable metal, such as silver, is applied to the surface of glass or other substrate by decomposing a layer of solution of a thermally decomposable metallo-organic deposition (MOD) compound such as silver neodecanoate in xylene. The MOD compound thermally decomposes into metal and gaseous by-products. Sealing is accomplished by depositing a layer of bonding metal, such as solder or a brazing alloy, on the metal film and then forming an assembly with another high melting point metal surface such as a layer of Kovar. When the assembly is heated above the temperature of the solder, the solder flows, wets the adjacent surfaces and forms a hermetic seal between the metal film and metal surface when the assembly cools.

Gallagher, Brian D.↗

Contact Angles and Surface Tension of Germanium-Silicon Melts

Precise knowledge of material parameters is more and more important for improving crystal growth processes. Two important parameters are the contact (wetting) angle and the surface tension, determining meniscus shapes and surface-tension driven flows in a variety of methods (Czochralski, EFG, floating-zone, detached Bridgman growth). The sessile drop technique allows the measurement of both parameters simultaneously and has been used to measure the contact angles and the surface tension of Ge(1-x)Si(x) (0 less than or equal to x less than or equal to 1.3) alloys on various substrate materials. Fused quartz, Sapphire, glassy carbon, graphite, SiC, carbon-based aerogel, pyrolytic boron nitride (pBN), AIN, Si3N4, and polycrystalline CVD diamond were used as substrate materials. In addition, the effect of different cleaning procedures and surface treatments on the wetting behavior were investigated. Measurements were performed both under dynamic vacuum and gas atmospheres (argon or forming gas), with temperatures up to 1100 C. In some experiments, the sample was processed for longer times, up to a week, to investigate any changes of the contact angle and/or surface tension due to slow reactions with the substrate. For pure Ge, stable contact angles were found for carbon-based substrates and for pBN, for Ge(1-x)Si(x) only for pBN. The highest wetting angles were found for pBN substrates with angles around 170deg. For the surface tension of Ge, the most reliable values resulted in gamma(T) = (591- 0.077 (T-T(sub m)) 10(exp -3)N/m. The temperature dependence of the surface tension showed similar values for Ge(1-x)Si(x), around -0.08 x 10(exp -3)N/m K, and a compositional dependence of 2.2 x 10(exp -3)N/m at%Si.

Croell, A.↗

Evaluation of Factors Affecting Powdered Drug Reconstitution in Microgravity

Owing to the high cost of transporting mass into space, and the small volume available for equipment in the Space Shuttle Orbiter and the International Space Station, refrigeration space is extremely limited. For this reason, there exists strong motivation for transporting certain drugs in powdered form so that they do not require refrigeration. When needed, the powdered drug will be mixed with saline to obtain a liquid form that may be injected intravenously. While this is a relatively simple task in a 1-G environment, there are some difficulties that may be encountered in 0-G. In non-accelerated spaceflight, gravitational and inertial forces are eliminated allowing other smaller forces, such as capillary forces and surface tension, to dominate the behavior of fluids. For instance, water slowly ejected from a straw will tend to form a sphere, while fluid in a container will tend to wet the inside surface forming a highly rounded meniscus. Initial attempts at mixing powdered drugs with saline in microgravity have shown a tendency toward forming foamy emulsions instead of the desired homogeneous solution. The predominance of adhesive forces between the drug particles and the interface tensions at the gas/liquid and solid/liquid interfaces drastically reduce the rate of deaggregation of the drug powder and also reduce the rate of absorption of saline by the powder mass. In addition, the capillary forces cause the saline to wet the inside of the container, thus trapping air bubbles within the liquid. The rate of dissolution of a powder drug is directly proportional to the amount of surface area of the solid that is exposed to liquid solvent. The surface area of drug that is in contact with the liquid is greatly reduced in microgravity and, as a result, the dissolution rate is reduced as well. The KC-135 research described here was aimed at evaluating the extent to which it is possible to perform drug reconstitution in the weightlessness of parabolic flight using standard pharmacological supplies. The experiment included a parametric assessment of possible factors affecting the reconstitution process. The specific questions that we wished to answer were: (1) Is it possible to reconstitute powdered drugs in weightlessness using standard pharmacological equipment? (2) What are the differences between drug reconstitution in a 1-G and a 0-G environment? (3) What techniques of mixing the drug powder and diluent are more successful? (4) What physical and chemical factors play a role in determining the success of mixing and dissolution? (5) Is it necessary to employ crewmember and equipment restraints during the reconstitution process?

Schaffner, Grant↗

Consistency in long-term observations of oceans and ice from space

Satellite remote sensing has provided powerful tools for constructing long-term records of observations of many of Earth's geophysical processes. Geophysicists studying climage change would like to construct time series of data which are as long, accurate, and consistent as possible. While technological advances continue to improve the quality of observations from space, they also present consistency problems. The scanning multichannel microwave radiometer (SMMR), which operated from October 1978 to August 1987, and the special sensor microwave imager (SSMI), which overlapped with the SMMR for nearly two months in 1987, have provided microwave radiances which have been used to monitor long-term changes in sea ice concentration and snow accumulation, among other things. Inspection has shown, however, that brightness temperatures from the two sensors over the same polar firn-covered scene can differ by as much as 14 K. Calibration corrections for polar firn have been derived; in this paper, we present calculations addressing the physics of the small frequency and viewing angle differences between the SMMR and the SSMI on microwave emission from polar scenes containing free water. We focus here only on surface emission. We use a surface scattering model and study the effects of surface roughness, snow wetness, snow density, and young sea ice concentration. We also compare data from Antarctica with our modeled results. We find that for most scenes, surface roughness dominates over the effects of frequency and viewing angle differences, but that for open long-term times series, data must be calibrated and constructed at the geophysical product level rather than at the level of measured radiances.

Zabel, I. H. H.↗

Cryo-Etched Black Silicon for Use as Optical Black

Stray light reflected from the surface of imaging spectrometer components in particular, the spectrometer slit degrade the image quality. A technique has been developed for rapid, uniform, and cost-effective black silicon formation based on inductively coupled plasma (ICP) etching at cryogenic temperatures. Recent measurements show less than 1-percent total reflectance from 350 2,500 nm of doped black silicon formed in this way, making it an excellent option for texturing of component surfaces for reduction of stray light. Oxygen combines with SF6 + Si etch byproducts to form a passivation layer atop the Si when the etch is performed at cryogenic temperatures. Excess flow of oxygen results in micromasking and the formation of black silicon. The process is repeatable and reliable, and provides control over etch depth and sidewall profile. Density of the needles can be controlled to some extent. Regions to be textured can be patterned lithographically. Adhesion is not an issue as the nanotips are part of the underlying substrate. This is in contrast to surface growth/deposition techniques such as carbon nanotubes (CNTs). The black Si surface is compatible with wet processing, including processing with solvents, the textured surface is completely inorganic, and it does not outgas. In radiometry applications, optical absorbers are often constructed using gold black or CNTs. This black silicon technology is an improvement for these types of applications.

Yee, Karl Y.↗

Hydrophobicity of Cryogenic Fluids for Fuel Transfer in Space Applicaitons

Introduction Hydrophobicity is the tendency of a fluid to repel another material or fluid. Hydrophobiciy can be measured through the wetting angle of the fluid on the surface of the other material. The greater the wetting angle, the more hydrophobic the surface is against the fluid. Hydrophobicity properties can be caused by one of two means, either through physical properties or chemical properties [\citenum{NARBUTT2020121}]. Physical hydrophobicity due to the surface of a solid creating surface roughness/patterning, minimizing the contact area between the fluid and the surface. This can be observed throughout nature, such as the surface of lotus leaves or butterfly wings. This physical property can be induced on a variety of surfaces, namely through laser etching, allowing a surface to be finely lineated to imitate these natural surfaces while controlling quantity, depth, and patterns of the etching on the surface [\citenum{10.1063/1.4905616}]. Physical hydrophobicity is therefore dependent on several variables, including the surface that the fluid is on and properties of the fluid itself, such as density and surface tension, both of which are dependent on temperature and/or pressure. Chemical hydrophobicity [\citenum{MadeiraHydrophobocicicici}] is due to the inherent chemical properties of the materials being used. This is most commonly due to the molecular structures changing the polarity of the materials. Depending on a nonpolar material will repel a polar material, proving to be hydrophobic, conversely if the polarity of the materials is the same (polar – polar, nonpolar – nonpolar), they will attract each other. Cryogenics refers to the behavior of materials at very low temperatures (<\ang{-100} C) [\citenum{ZOHURI20181}]. In space applications many things are inherently cryogenic, therefore this is an important field. There has been little research in how hydrophobicity changes at cryogenic temperatures. Cryogenic fluids are commonly used as fuels for spacecraft, therefore, integrating a hydrophobic surface can increase the transfer rate of the fuel. To test this, several experiments were set up to determine the hydrophobic properties of cryogenic fluids, including nitrogen (LN2), argon (LAr), oxygen (LOx), hydrogen (LH2), and methane (CH4), at cryogenic temperatures. Etched Wafer Testing A silicon wafer cut from a crystal of silicon [100] was used to model the potential hydrophobicity of various cryogenic fluids. Silicon [100] references to the crystallographic orientation of the silicon crystals in the wafer. These wafers were then laser etched to create a surface that is more likely to be hydrophobic. To test the hydrophobicity of the wafers at cryogenic temperatures, the temperatures of the wafers must be reduced to the same temperature as the cryogenic fluid being used to prevent rapid boil-off. To achieve this a double-walled vacuum insulated glass chamber was utilized. The chamber is open, with a double-walled glass that can be placed in a vacuum to remove condensation from the outside to allow easier viewing of the experiment. Furthermore, the silicon wafer's temperature must be lowered to the temperature of LN2, as well as maintain the temperature throughout the experiment. To achieve this a piece of 6061 aluminum was used, creating a stand-off for the wafer and it would allow for the insulation of the temperature of the wafers. The container was then filled with LN2 and once the LN2 stabilized the vaporization and the levels of LN2 dropped under the height of the wafer, the wafer was then allowed to air dry. Once the wafer was dry from the LN2, drops of LN2 were placed on the surface of the wafer for observation. During the first trial, the LN2 that was dropped on the surface displayed nonhydrophobic behaviors, spreading out along the surface, with a minimal wetting angle (too small to be measured). This process was repeated for liquid argon. Further testing with other cryogenic liquids will require different testing apparatuses due to being more volatile. Furthermore, several papers [\citenum{voltvolt7}] have suggested that running a voltage can induce a hydrophobic effect throughout a surface, further testing will include a voltage (constant and oscillating) to determine if voltage influences inducing hydrophobicity at cryogenic temperatures. Chemical Testing Coating the interior walls of the fuel tanks and fuel lines can successfully create a hydrophobic surface. The inherent problem is finding a material that can be used to coat the surface, furthermore, at these temperatures, the coating will remain solid, which could pose issues in maintaining the hydrophobic properties. To test this water (polar) is hydrophobic against oils and fats (nonpolar), therefore the same experiment as the etched wafer testing was conducted to determine if the hydrophobic properties will persist as the nonpolar material remains solid and the polar material remains a fluid. The water remained hydrophobic, allowing testing can expand to the cryogenic fluids. However, another hurdle is faced in finding a chemically opposite material to the cryogenic fluids being tested. As many of the cryogenic fluids being tested are diatomic, they are inherently nonpolar, therefore, the material used for the hydrophobic coating must be polar. Polar greases and lubricants are difficult to come by, however, lithium stearate, appears to be a potential candidate for creating a coated hydrophobic surface for cryogenic fluids at cryogenic temperatures.

Cryogenics↗

Microwave emissions from soils with rough surfaces

The effect of surface roughness on the thermal microwave emission of soils has been studied with the Kirchoff approach. A model is presented that includes both the coherent and incoherent reflectivities of the rough surface. It is demonstrated that both the coherent and incoherent terms must be included in order for theoretical computations to provide good agreement with the experimental data, especially for wet soil, where surface roughness causes a dramatic increase in brightness temperature. In addition, the model including both the coherent and incoherent terms allows one to use the physically measured surface height deviations of the rough surface in the model. Previous models have required that an effective height, not equal to the actual surface height measurements, be used in order for theoretical computations to match measurements.

Tsang, L.↗

Magnetic Anisotropy and Stress Dependent Epoxy Wetting in FeNi-based Metal Amorphous Nanocomposite

Recently developed FeNi-based metal amorphous nanocomposites (MANCs) used in high-speed motors (HSMs) exhibit reduced eddy current losses while maintaining good mechanical properties and glass-forming abilities. Magnetic anisotropy in (Fe 70 Ni 30 ) 80 Nb 4 B 14 Si 2 amorphous magnetic ribbon (AMR) in the as-cast state and upon conventional (T CA ) and strain (T SA ) annealing heat treatment is investigated. From ribbon samples in as-cast condition, quenched in stress from planar flow casting (PFC) induced as-cast curvature derived uniaxial magnetic anisotropy. Stress relief by conventional furnace annealing at T CA > 350 °C achieved isotropic properties in the bulk. Annealing about the primary crystallization temperature, T CA ~ 450 °C, resulted in the formation of both FCC and BCC nanocrystallites and evolution to isotropic bulk magnetic properties confirming the random anisotropy model. In samples strain annealed at T SA = 440 °C at various tensions, relatively large controlled induced uniaxial anisotropy is achieved. The largest magnetic anisotropy occurs in annealing under the stress of 250 MPa yielding an anisotropy field of 7.1 x 10 4 A/m. Surface anisotropy observed by MOKE differs from bulk anisotropy due to image contrast from closure domains. Epoxy coatings are important for improved bonding, mechanical properties, and resistivity in tape-wound MANC cores for HSMs. Using a sessile droplet method, the equilibrium contact angle of an epoxy droplet on a tensile stress annealed MANC exhibits stress dependent surface energies. Anisotropic wetting in FeNi-based MANC heat treated at T CA = 440 °C mimics surface magnetic anisotropy observed by MOKE.

soft magnetic materials↗

Infrared temperature measurements over bare soil and vegetation - A HAPEX perspective

Preliminary analyses of aircraft and ground measurements made in France during the HAPEX experiment show that horizontal radiometric surface temperature variations, as viewed by aircraft, can reflect the vertical profile of soil moisture (soil versus root zone) because of horizontal variations in vegetation density. Analyses based on one day's data show that, although horizontal variations in soil moisture were small, the vertical differences between a dry surface and a wet root zone were large. Horizontal temperature differences between bare soil, corn and oats reflect differences in the fractional vegetation cover, as seen by the radiometer. On the other hand, these horizontal variations in radiometric surface temperature seem to reflect real horizontal variations in surface turbulent energy fluxes.

Carlson, Toby N.↗

Aircraft and ground vehicle friction measurements obtained under winter runway conditions

Tests with specially instrumented NASA B-737 and B-727 aircraft together with several different ground friction measuring devices have been conducted for a variety of runway surface types and wetness conditions. This effort is part of the Joint FAA/NASA Aircraft/Ground Vehicle Runway Friction Program aimed at obtaining a better understanding of aircraft ground handling performance under adverse weather conditions, and defining relationships between aircraft and ground vehicle tire friction measurements. Aircraft braking performance on dry, wet, snow-, and ice-covered runway conditions is discussed together with ground vehicle friction data obtained under similar runway conditions. For the wet, compacted snow- and ice-covered runway conditions, the relationship between ground vehicles and aircraft friction data is identified. The influence of major test parameters on friction measurements such as speed, test tire characteristics, and surface contaminant-type are discussed. The test results indicate that use of properly maintained and calibrated ground vehicles for monitoring runway friction conditions should be encouraged particularly under adverse weather conditions.

Yager, Thomas J.↗

Current status of Joint FAA/NASA Runway Friction Program

Tests with specially instrumented NASA B-737 and FAA B-727 aircraft together with several different ground friction measuring devices have been conducted for a variety of runway surface types and wetness conditions. This effort is part of the Joint FAA/NASA Aircraft Ground Vehicle Runway Friction Program aimed at obaining a better understanding of aircraft ground handling performance under adverse weather conditions and defining relationships between aircraft and ground vehicle tire friction measurements. Aircraft braking performance on dry, wet, snow-, and ice-covered runway conditions is discussed together with ground vehicle friction data obtained under similar runway conditions. For the wet, compacted snow- and ice-covered runway conditions, the relationship between ground vehicles and aircraft friction data is identified. The influence of major test parameters on friction measurements such as speed, test tire characteristics, and surface contaminant type are discussed. The test results indicate that use of properly maintained and calibrated ground vehicles for monitoring runway friction conditions should be encouraged particularly under adverse weather conditions. The current status of the runway friction program is summarized and future test plans are identified.

Yager, Thomas J.↗

A summary of recent aircraft/ground vehicle friction measurement tests

Tests were carried out to evaluate a variety of runway surface types and wetness conditions, using specially instrumented NASA B-737 and B-727 aircraft and several ground friction measuring devices. The performance data for aircraft braking on dry, wet, snow-covered, and ice-covered runway conditions are presented and compared to ground-vehicle friction data obtained under similar runway conditions. The relationships between ground vehicles and the aircraft friction data are identified, and the effects on friction of major test parameters, such as the speed, the tire characteristics, and the type of surface-contaminant are discussed. The results demonstrated that properly maintained and calibrated ground vehicles can be used to monitor the runway friction conditions.

Yager, Thomas J.↗

Reaction layer formation at the graphite/copper-chromium alloy interface

Sessile drop tests were used to obtain information about copper chromium alloys that suitably wet graphite. Characterization of graphite/copper-chromium alloy interfaces subjected to elevated temperatures were conducted using scanning electron micrography, energy dispersive spectroscopy, auger electron spectroscopy, and x ray diffraction analyses. These analyses indicate that during sessile drop tests conducted at 1130 C for one hour, copper alloys containing greater than 0.98 percent chromium form continuous reaction layers of approximately 10 micron thickness. The reaction layers adhere to the graphite surface. The copper wets the reaction layer to form a contact angle of 60 degrees or less. X ray diffraction results indicate that the reaction layer is chromium carbide. The kinetics of reaction layer formation were modelled in terms of bulk diffusion mechanisms. Reaction layer thickness is controlled initially by the diffusion of Cr out of Cu alloy and later by the diffusion of C through chromium carbide.

Devincent, Sandra M.↗

Reaction layer formation at the graphite/copper-chromium alloy interface

Sessile drop tests were used to obtain information about copper chromium alloys that suitably wet graphite. Characterization of graphite/copper-chromium alloy interfaces subjected to elevated temperatures were conducted using scanning electron micrography, energy dispersive spectroscopy, Auger electron spectroscopy, and X-ray diffraction analyses. These analyses indicate that during sessile drop tests conducted at 1130 C for one hour, copper alloys containing greater than 0.98 percent chromium form continuous reaction layers of approximately 10 micron thickness. The reaction layers adhere to the graphite surface. The copper wets the reaction layer to form a contact angle of 60 degrees or less. X-ray diffraction results indicate that the reaction layer is chromium carbide. The kinetics of reaction layer formation were modelled in terms of bulk diffusion mechanisms. Reaction layer thickness is controlled initially by the diffusion of Cr out of Cu alloy and later by the diffusion of C through chromium carbide.

Devincent, Sandra M.↗

Development of graphite/copper composites utilizing engineered interfaces

In situ measurements of graphite/copper alloy contact angles were made using the sessile drop method. The interfacial energy values obtained from these measurements were then applied to a model for the fiber matrix interfacial debonding phenomenon found in graphite/copper composites. The formation obtained from the sessile drop tests led to the development of a copper alloy that suitably wets graphite. Characterization of graphite/copper alloy interfaces subjected to elevated temperatures was conducted using Scanning Electron Microscopy, Energy Dispersive Spectroscopy, Auger Electron Spectroscopy, and X Ray Diffraction analyses. These analyses indicated that during sessile drop tests conducted at 1130 C for 1 hour, copper alloys containing greater than 0.98 at pct chromium form continuous reaction layers of approx. 10 microns in thickness. The reaction layers are adherent to the graphite surface. The copper wets the reaction layer to form a contact angle of 60 deg or less. X ray diffraction results indicate that the reaction layer is Cr3C2.

Devincent, Sandra M.↗

Laser Processed Condensing Heat Exchanger Technology Development

The reliance on non-permanent coatings in Condensing Heat Exchanger (CHX) designs is a significant technical issue to be solved before long-duration spaceflight can occur. Therefore, high reliability CHXs have been identified by the Evolvable Mars Campaign (EMC) as critical technologies needed to move beyond low earth orbit. The Laser Processed Condensing Heat Exchanger project aims to solve these problems through the use of femtosecond laser processed surfaces, which have unique wetting properties and potentially exhibit anti-microbial growth properties. These surfaces were investigated to identify if they would be suitable candidates for a replacement CHX surface. Among the areas researched in this project include microbial growth testing, siloxane flow testing in which laser processed surfaces were exposed to siloxanes in an air stream, and manufacturability.

Hansen, Scott↗