CfAIR2: Near-infrared light curves of 94 TYPE Ia supernovae

CfAIR2 is a large, homogeneously reduced set of near-infrared (NIR) light curves (LCs) for Type Ia supernovae (SNe Ia) obtained with the 1.3 m Peters Automated InfraRed Imaging TELescope. This data set includes 4637 measurements of 94 SNe Ia and 4 additional SNe Iax observed from 2005 to 2011 at the Fred Lawrence Whipple Observatory on Mount Hopkins, Arizona. CfAIR2 includes JHK{sub s} photometric measurements for 88 normal and 6 spectroscopically peculiar SN Ia in the nearby universe, with a median redshift of z ∼ 0.021 for the normal SN Ia. CfAIR2 data span the range from −13 days to +127 days from B-band maximum. More than half of the LCs begin before the time of maximum, and the coverage typically contains ∼13–18 epochs of observation, depending on the filter. We present extensive tests that verify the fidelity of the CfAIR2 data pipeline, including comparison to the excellent data of the Carnegie Supernova Project. CfAIR2 contributes to a firm local anchor for SN cosmology studies in the NIR. Because SN Ia are more nearly standard candles in the NIR and are less vulnerable to the vexing problems of extinction by dust, CfAIR2 will help the SN cosmology community develop more precise and accurate extragalactic distance probes to improve our knowledge of cosmological parameters, including dark energy and its potential time variation.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermal oxidation of nuclear graphite and pyrolytic carbon coatings

The oxidation of pyrolytic carbon (PyC) deposited via fluidized bed chemical vapor deposition was characterized and compared with that of standard nuclear-grade graphite. The materials were heated at 700 to 1000 °C in a thermogravimetric analysis system under 20% v/v O 2 flow, allowing for direct comparison of dynamic oxidative mass change in each material. Further, three different PyC samples fabricated under different conditions exhibited variation in total mass loss and mass loss rate, varying by as much as 709 mg/cm 2 in total mass loss and 14.2 (mg/cm 2 )/min in mass loss rate at a single temperature. These variations highlight the correlation between PyC microstructure/defect density and oxidation susceptibility. Additionally, changes in the microstructure and composition between PyC and graphite were characterized via scanning electron microscopy and correlated to the mass loss results. The results of this work have implications toward the safety of tristructural isotropic (TRISO) and other coated particle fuels, especially under off-normal conditions, given the limited information that exists about the oxidation behavior of PyC.

36 MATERIALS SCIENCE↗

Evaluation of interpolation methods for surface-based motion compensated tomographic reconstruction for cardiac angiographic C-arm data

Purpose: For interventional cardiac procedures, anatomical and functional information about the cardiac chambers is of major interest. With the technology of angiographic C-arm systems it is possible to reconstruct intraprocedural three-dimensional (3D) images from 2D rotational angiographic projection data (C-arm CT). However, 3D reconstruction of a dynamic object is a fundamental problem in C-arm CT reconstruction. The 2D projections are acquired over a scan time of several seconds, thus the projection data show different states of the heart. A standard FDK reconstruction algorithm would use all acquired data for a filtered backprojection and result in a motion-blurred image. In this approach, a motion compensated reconstruction algorithm requiring knowledge of the 3D heart motion is used. The motion is estimated from a previously presented 3D dynamic surface model. This dynamic surface model results in a sparse motion vector field (MVF) defined at control points. In order to perform a motion compensated reconstruction, a dense motion vector field is required. The dense MVF is generated by interpolation of the sparse MVF. Therefore, the influence of different motion interpolation methods on the reconstructed image quality is evaluated. Methods: Four different interpolation methods, thin-plate splines (TPS), Shepard's method, a smoothed weighting function, and a simple averaging, were evaluated. The reconstruction quality was measured on phantom data, a porcine model as well as on in vivo clinical data sets. As a quality index, the 2D overlap of the forward projected motion compensated reconstructed ventricle and the segmented 2D ventricle blood pool was quantitatively measured with the Dice similarity coefficient and the mean deviation between extracted ventricle contours. For the phantom data set, the normalized root mean square error (nRMSE) and the universal quality index (UQI) were also evaluated in 3D image space. Results: The quantitative evaluation of all experiments showed that TPS interpolation provided the best results. The quantitative results in the phantom experiments showed comparable nRMSE of Almost-Equal-To 0.047 {+-} 0.004 for the TPS and Shepard's method. Only slightly inferior results for the smoothed weighting function and the linear approach were achieved. The UQI resulted in a value of Almost-Equal-To 99% for all four interpolation methods. On clinical human data sets, the best results were clearly obtained with the TPS interpolation. The mean contour deviation between the TPS reconstruction and the standard FDK reconstruction improved in the three human cases by 1.52, 1.34, and 1.55 mm. The Dice coefficient showed less sensitivity with respect to variations in the ventricle boundary. Conclusions: In this work, the influence of different motion interpolation methods on left ventricle motion compensated tomographic reconstructions was investigated. The best quantitative reconstruction results of a phantom, a porcine, and human clinical data sets were achieved with the TPS approach. In general, the framework of motion estimation using a surface model and motion interpolation to a dense MVF provides the ability for tomographic reconstruction using a motion compensation technique.

60 APPLIED LIFE SCIENCES↗

Variability of prediction of maximal oxygen concumption on the cycle ergometer using standard equations

Several investigations within the Exercise Countermeasures Project at the NASA Johnson Space Center focused on the assessment of maximum oxygen consumption (VO2(sub max)) within the Astronaut Corps pre- and postspace flight. Investigations during the Apollo era suggested that there was a significant decrease in postflight VO2(sub max) when compared to preflight values, and current studies have documented that this trend continues in the Space Shuttle era. It is generally accepted and was confirmed in our laboratory that VO2(sub max) can be predicted from submaximal measures taken during graded exercise tests on the cycle ergometer with respect to populations. However, previous work had not examined the effect of day-to-day variations in the physiologic responses that might alter these predictions for individuals. Stability of individual submaximal data over serial tests is important so that predicted changes in VO2(sub max) are reflective of actual VO2(sub max) changes. Therefore, the purpose of this investigation was to determine which of the accepted equations to predict VO2(sub max) would be less affected by normal daily physiologic changes.

Greenisen, Michael C.↗

Direction Modulated Brachytherapy for Treatment of Cervical Cancer. II: Comparative Planning Study With Intracavitary and Intracavitary–Interstitial Techniques

Purpose: To perform a comprehensive comparative planning study evaluating the utility of the proposed direction modulated brachytherapy (DMBT) tandem applicator against standard applicators, in the setting of image guided adaptive brachytherapy of cervical cancer. Methods and Materials: A detailed conceptual article was published in 2014. The proposed DMBT tandem applicator has 6 peripheral grooves of 1.3-mm width, along a 5.4-mm-thick nonmagnetic tungsten alloy rod of density 18.0 g/cm{sup 3}, capable of generating directional dose profiles. We performed a comparative planning study with 45 cervical cancer patients enrolled consecutively in the prospective observational EMBRACE study. In all patients, MRI-based planning was performed while utilizing various tandem-ring (27 patients) and tandem-ring-needles (18 patients) applicators, in accordance with the Groupe Européen de Curiethérapie–European Society for Radiotherapy and Oncology recommendations. For unbiased comparisons, all cases were replanned with an in-house–developed inverse optimization code while enforcing a uniform set of constraints that are reflective of the clinical practice. All plans were normalized to the same high-risk clinical target volume D90 values achieved in the original clinical plans. Results: In general, if the standard tandem was replaced with the DMBT tandem while maintaining all other planning conditions the same, there was consistent improvement in the plan quality. For example, among the 18 tandem-ring-needles cases, the average D2cm{sup 3} reductions achieved were −2.48% ± 11.03%, −4.45% ± 5.24%, and −5.66% ± 6.43% for the bladder, rectum, and sigmoid, respectively. An opportunity may also exist in avoiding use of needles altogether for when the total number of needles required is small (approximately 2 to 3 needles or less), if DMBT tandem is used. Conclusions: Integrating the novel DMBT tandem onto both intracavitary and intracavitary–interstitial applicator assembly enabled consistent improvement in the sparing of the OARs, over a standard “single-channel” tandem, though individual variations in benefit were considerable. Although at an early stage of development, the DMBT concept design is demonstrated to be useful and pragmatic for potential clinical translation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Waves in Plasmas

Quadratic corrections to the metaplectic formulation of mode conversions. In this work we showed how to systematically deal with quadratic corrections beyond the usual linearization of the dispersion matrix at a conversion. The linearization leads to parabolic cylinder functions as the local approximation to the full-wave behavior, but these do not include the variation in amplitude associated with ray refraction in the neighborhood of the conversion. Hence, the region over which they give a good fit to the incoming and outgoing WKB solutions is small. By including higher order corrections it is possible to provide a much more robust matching. We also showed that it was possible, in principle, to extend these methods to arbitrary order. A new normal form for mode conversion. This is based upon our earlier NSF-DOE-funded work on ray helicity. We have begun efforts to apply these new ideas in practical ray tracing algorithms. Group theoretical foundation of path integrals and phase space representations of wave problems. Using the symbol theory of N. Zobin, we developed a new understanding of path integrals on phase space. The initial goal was to find practical computational tools for dealing with non-standard mode conversions. Along the way we uncovered a new way to represent wave functions directly on phase space without the intermediary of a Wigner function. We are exploring the use of these ideas for numerical studies of conversion, with the goal of eventually incorporating kinetic effects. Wave packet studies of gyroresonance crossing. In earlier work, Huanchun Ye and Allan Kaufman -- building upon ideas due to Lazar Friedland -- had shown that gyroresonance crossings could be treated as a double conversion. This perspective is one we have used for many of our papers since then. We are now performing a detailed numerical comparison between full-wave and ray tracing approaches in the study of minority-ion gyroresonance crossing. In this study, a fast magnetosonic wave -- supported by a majority-ion species such as deuterium -- crosses the resonance layer associated with a minority species, such as hydrogen. By using wave packets instead of harmonic solutions, it becomes easy to see the evolution in k-space of the minority-ion disturbance, and the time delay for emission of the reflected fast-wave packet. Iterated conversion in a cavity. When mode conversion occurs in a cavity where rays are trapped, multiple conversions will occur and the resulting absorption profile will typically have a complicated spatial dependence due to overlapping interference patterns. The goal of this work is to develop fast and efficient ray-based methods for computing the cavity response to external driving, and to compute the spatial absorption profile. We have introduced a new approach that allows us to visualize in great detail the underlying iterated ray geometry, and should lead to simpler methods for identifying parameter values where global changes occur in the qualitative response (e.g. global bifurcations).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analyzing the Quantum Approximate Optimization Algorithm: Ansätze, Symmetries, and Lie Algebras

The quantum approximate optimization algorithm (QAOA) has been proposed as a method to obtain approximate solutions for combinatorial optimization tasks. In this work, we study the underlying algebraic properties of three QAOA ansätze for the maximum-cut problem on connected graphs, while focusing on the generated Lie algebras as well as their invariant subspaces. Specifically, we analyze the standard QAOA ansatz as well as the orbit and multiangle ansätze. We are able to fully characterize the Lie algebras of the multiangle ansatz across arbitrary connected graphs, finding that they only fall into one of just six families. Aside from the cycle and path graphs, the Lie dimensions for every graph are exponentially large in the system size, meaning that multiangle ansätze are extremely prone to exhibiting barren plateaus. Then, a similar quasi-graph-independent Lie-algebraic characterization beyond the multiangle ansatz is impeded as the circuit exhibits additional “hidden” symmetries besides those naturally arising from a certain parity-superselection operator and all automorphisms of the considered graph. Disregarding the “hidden” symmetries, we can upper bound the dimensions of the orbit and the standard Lie algebras, and the dimensions of the associated invariant subspaces are determined via explicit character formulas. To finish, we conjecture that (for most graphs) the standard Lie algebras have only components that are either exponential or that grow, at most, polynomially with the system size. This would imply that the QAOA is either prone to barren plateaus or classically simulable. More generally, our work provides a symmetry framework and tools to analyze any desired variational quantum algorithm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-T-557: Evaluation of Detector Response in Rectangular Small Field Dosimetry

Purpose: As stereotactic treatment modalities grow towards becoming the standard of care, the need for accurate dose computation in small fields is becoming increasingly essential. The purpose of this study is to evaluate the response of different detectors, intended for small field dosimetry, in jaw defined small rectangular fields by analyzing output factors from a stereotactic clinical accelerator. Methods: Two Dosimeters, the Exradin A26 Microionization Chamber (Standard Imaging) and Edge Diode Detector (Sun Nuclear) were used to measure output factors taken on the Varian Edge Stereotactic Linear accelerator. Measurements were taken at 6MV and 6FFF at 10cm depth, 100cm SSD in a 48×48×40cm3 Welhoffer BluePhantom2 (IBA) with X and Y jaws set from 0.6 to 2.0cm. Output factors were normalized to a 5×5cm2 machine-specific reference field. Measurements were made in the vertical orientation for the A26 and horizontal orientation for both the A26 and Edge. Output factors were measured as: OF{sub FS} = M{sub FS}/M{sub ref} where M{sub FS} and M{sub ref} are the measured signals for the clinical field and the reference field, respectively. Measured output factors were then analyzed to establish relative responses of the detectors in small fields. Results: At 6MV the Edge detector exhibited a variation in output factors dependent on jaw positioning (X-by-Y vs Y-by-X) of 5.7% of the 5×5cm reference output and a variation of 3.33% at 6FFF. The A26 exhibited variation of output factor dependent on jaw positioning of upto 7.7% of the 5×5cm reference field at 6MV and upto 5.33% at 6FFF. Conclusion: Both the Edge detector and A26 responded as expected at small fields however a dependence on the jaw positioning was noted. At 6MV and 6FFF the detector response showed an increased dependence on the positioning of the X jaws as compared to the positioning of the Y jaws.

60 APPLIED LIFE SCIENCES↗

A Spectral-line Analysis of the G8 III Standard ε VIR

Eleven seasons of spectroscopic data comprised of 107 exposures for the stable G8 III standard star, ε Vir are analyzed for projected rotation rate and granulation parameters. A Fourier analysis of the line shapes yield v sin i = 3.06 ± 0.20 km s{sup −1} and a radial-tangential macroturbulence dispersion ζ {sub RT} = 5.16 ± 0.08 km s{sup −1}. The radial velocity over nine seasons is constant to 18 m s{sup −1}. The absolute radial velocity with granulation blueshifts (but not gravitational redshift) removed is −14120 ± 75 m s{sup −1}. Line-depth ratios show the temperature to be constant to 0.7 K over 11 years, although a small secular rise or cyclic variation ∼1 K cannot be ruled out. The third-signature plot shows that the star has granulation velocities 10% larger than the Sun's. Mapping the Fe i λ 6253 line bisector on to the third-signature plot indicates a normal-for-giants flux deficit area of 12.8%, indicating ∼134 K temperature difference between granules and lanes. Deficit velocities of GK giants are seen to shift to higher values with higher luminosity, ∼0.75 km s{sup −1} over Δ M {sub V} ∼ 1.5, indicating larger velocity differences between granules and lanes for giants higher in the HR diagram.

79 ASTRONOMY AND ASTROPHYSICS↗

Heat and Momentum Transfer Studies in High Reynolds Number Wavy Films at Normal and Reduced Gravity Conditions

We examined the effect of the gas flow on the liquid film when the gas flows in the countercurrent direction in a vertical pipe at normal gravity conditions. The most dramatic effect of the simultaneous flow of gas and liquid in pipes is the greatly increased transport rates of heat, mass, and momentum. In practical situations this enhancement can be a benefit or it can result in serious operational problems. For example, gas-liquid flow always results in substantially higher pressure drop and this is usually undesirable. However, much higher heat transfer coefficients can be expected and this can obviously be of benefit for purposes of design. Unfortunately, designers know so little of the behavior of such two phase systems and as a result these advantages are not utilized. Due to the complexity of the second order boundary model as well as the fact that the pressure variation across the film is small compared to the imposed gas phase pressure, the countercurrent gas flow affect was studied for the standard boundary layer model. A different stream function that can compensate the shear stress affect was developed and this stream function also can predict periodic solutions. The discretized model equations were transformed to a traveling wave coordinate system. A stability analysis of these sets of equations showed the presence of a Hopf bifurcation for certain values of the traveling wave velocity and the shear stress. The Hopf celerity was increased due to the countercurrent shear. For low flow rate the increases of celerity are more than for the high flow rate, which was also observed in experiments. Numerical integration of a traveling wave simplification of the model also predicts the existence of chaotic large amplitude, nonperiodic waves as observed in the experiments. The film thickness was increased by the shear.

Balakotaiah, V.↗

Crop Surveillance Demonstration Using a Near-Daily MODIS Derived Vegetation Index Time Series

Effective response to crop disease outbreaks requires rapid identification and diagnosis of an event. A near-daily vegetation index product, such as a Normalized Difference Vegetation Index (NDVI), at moderate spatial resolution may serve as a good method for monitoring quick-acting diseases. NASA s Moderate Resolution Imaging Spectroradiometer (MODIS) instrument flown on the Terra and Aqua satellites has the temporal, spatial, and spectral properties to make it an excellent coarse-resolution data source for rapid, comprehensive surveillance of agricultural areas. A proof-of-concept wide area crop surveillance system using daily MODIS imagery was developed and tested on a set of San Joaquin cotton fields over a growing season. This area was chosen in part because excellent ground truth data were readily available. Preliminary results indicate that, at least in the southwestern part of the United States, near-daily NDVI products can be generated that show the natural variations in the crops as well as specific crop practices. Various filtering methods were evaluated and compared with standard MOD13 NDVI MODIS products. We observed that specific chemical applications that produce defoliation, which would have been missed using the standard 16-day product, were easily detectable with the filtered daily NDVI products.

McKellip, Rodney↗

Hierarchical Bayesian Thermonuclear Rate for the 7 Be(n,p) 7 Li Big Bang Nucleosynthesis Reaction

Big Bang nucleosynthesis provides the earliest probe of standard model physics, at a time when the universe was less than 1000 seconds old. It determines the abundances of the lightest nuclides, which give rise to the subsequent history of the visible matter in the universe. This work derives new 7 Be(n,p) 7 Li thermonuclear reaction rates based on all available experimental information. This reaction sensitively impacts the primordial abundances of 7 Be and 7 Li during big bang nucleosynthesis. We critically evaluate all available data and disregard experimental results that are questionable. For the nuclear model, we adopt an incoherent sum of single-level, two-channel, R -matrix approximation expressions, which are implemented into a hierarchical Bayesian model, to analyze the remaining six data sets we deem most reliable. In the fitting of the data, we consistently model all known sources of uncertainty, including discrepant absolute normalizations of different data sets, and also take the variation of the neutron and proton channel radii into account, hence providing less biased estimates of the 7 Be(n,p) 7 Li thermonuclear rates. From the resulting posteriors, we extract R -matrix parameters ($E_r, γ^2_n, γ^2_p$) and derive excitation energies and partial and total widths. Our fit is sensitive to the contributions of the first three levels above the neutron threshold. Reaction rates were computed by integrating 10,000 samples of the reduced cross section. Our 7 Be(n,p) 7 Li thermonuclear rates have uncertainties between 1.5% and 2.0% at temperatures of ≤1 GK. Finally, we compare our rates to previous results and find that the 7 Be(n,p) 7 Li rates most commonly used in big bang simulations have uncertainties that are too optimistic.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CALiPER Retail Lamps Study RRL3.2 Lumen and Chromaticity Maintenance of LED A lamps Operated in Steady-State Conditions

The lumen depreciation and color shift of 17 different A lamps (15 LED, 1 CFL, 1 halogen) was monitored in the automated long-term test apparatus (ALTA) for more than 7,500 hours. Ten samples of each lamp model were tested, with measurements recorded on a weekly basis. The lamps were operated continuously at an ambient temperature of 45°C (-1°C). Importantly, the steady-state test conditions were not optimized for inducing catastrophic failure for any of the lamp technologies—to which thermal cycling is a strong contributor— and are not typical of normal use patterns—which usually include off periods where the lamp cools down. Further, the test conditions differ from those used in standardized long-term test methods (i.e., IES LM-80, IES LM-84), so the results should not be directly compared. On the other hand, the test conditions are similar to those used by ENERGY STAR (when elevated temperature testing is called for). Likewise, the conditions and assumptions used by manufacturers to generated lifetime claims may vary; the CALiPER long-term data is informative, but cannot necessarily be used to discredit manufacturer claims. The test method used for this investigation should be interpreted as one more focused on the long-term effects of elevated temperature operation, at an ambient temperature that is not uncommon in luminaires. On average, the lumen maintenance of the LED lamps monitored in the ALTA was better than benchmark lamps, but there was considerable variation from lamp model to lamp model. While three lamp models had average lumen maintenance above 99% at the end of the study period, two products had average lumen maintenance below 65%, constituting a parametric failure. These two products, along with a third, also exhibited substantial color shift, another form of parametric failure. While none of the LED lamps exhibited catastrophic failure—and all of the benchmarks did—the early degradation of performance is concerning, especially with a new technology trying to build a reputation with consumers. Beyond the observed parametric failures nearly half of the products failed to meet early-life thresholds for lumen maintenance, which were borrowed from ENERGY STAR specifications. That is, the lumen maintenance was sufficiently low at 6,000 hours that seven of the products are unlikely to have lumen maintenance above 70% at their rated lifetime (which was usually 25,000 hours). Given the methods used for this investigation—most notably continuous operation—the results should not be interpreted as indicative of a lamp’s performance in a typical environment. Likewise, these results are not directly relatable to manufacturer lifetime claims. This report is best used to understand the variation in LED product performance, compare the robustness of LED lamps and benchmark conventional lamps, and understand the characteristics of lumen and chromaticity change. A key takeaway is that the long-term performance of LED lamps can vary greatly from model to model (i.e., the technology is not homogenous), although the lamp-to-lamp consistency within a given model is relatively good. Further, operation of LED lamps in an enclosed luminaire (or otherwise in high ambient temperatures), can induce parametric failure of LEDs much earlier than their rated lifetime; manufacturer warnings about such conditions should be followed if performance degradation is unacceptable.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Raman intensity as a probe of concentration near a crystal growing in solution

The feasibility of using Raman spectral scattering signals for measurements of concentration profiles near a crystal interface during growth or dissolution is discussed. With KH2PO4 (KDP) as a test material, optical multichannel analyzer (OMA) detection of a solute Raman vibrational band provided direct quantification of solute concentration with band intensity. The intersection of incident laser and Raman collection optics provided 3-D selective point measurements of the solution concentration field. Unlike many other techniques, the Raman band intensity is not sensitive to the typical temperature variations. Precision calibration of Raman intensity versus KDP concentration with less than 1 pct standard deviation error levels was demonstrated. A fiber optic, which sampled incident laser intensity and coupled it to the OMA, provided a fully synchronized monitor of fluctuations in laser power to correlate with observed Raman signals. With 1 W of laser power at the sample, good data statistics required eight repeated data collections at approximately 2.5 min collection. The accumulated time represents the concentration measurement time at one spatial location. Photomicroscopy documented a 30 micrometer diameter by 200 micrometer of laser Raman scattering region in the solution near the crystal surface. The laser beam was able to approach up to 25 micrometer from the crystal surface. However, a crystal surface reflected intensity contribution was weakly detectable. Nucleated microcrystals were seen in the crystal-growing solution. These microcrystals convect right up to the crystal surface and indicate no quiet diffusion region under normal gravity conditions. Translation of the solution cell with respect to the optics caused systematic intensity errors.

Wilkinson, R. Allen↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing, determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rates along with the average and maximum qualified stack flow rates for each of the LAB facility stacks. For each stack, the operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10°, except for the LB-C2 Fan A results, which were an average of 13.7°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 4.1% COV, which were all within the range of the target percent coefficient of variation values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Partnership for Edge Physics Simulation

A major goal of our participation in the Edge Physics Simulation project has been to contribute to the understanding of the self-organization of tokamak turbulence fluctuations resulting in the formation of a staircase structure in the ion temperature. A second important goal is to demonstrate how small scale turbulence in plasmas self-organizes with dynamically driven quasi-stationary flow shear. These goals have been accomplished through the analyses of the statistical properties of XGC1 flux driven Gyrokinetic electrostatic ion temperature gradient (ITG) turbulence simulation data in which neutrals are included. The ITG turbulence data, and in particular fluctuation data, were obtained from a massively parallel flux-driven gyrokinetic full-f particle-in-cell simulation of a DIII-D like equilibrium. Below some the findings are summarized. It was observed that the emergence of staircase structure is related to the variations in the normalized temperature gradient length (R/LT) and the poloidal flow shear. Average turbulence intensity is found to be large in the vicinity of minima in R/LTi, where ITG growth is expected to be lower. The distributions of the occurrences of potential fluctuation are found to be Gaussian away from the staircase-step locations, but they are found to be non-Gaussian in the vicinity of staircase-step locations. The results of analytically derived expressions for the distribution of the occurrences of turbulence intensity and intensity flux were compared with the corresponding quantities computed using XGC1 simulation data and good agreement is found. The derived expressions predicts inward and outward propagation of turbulence intensity flux in an intermittent fashion. The outward propagation of turbulence intensity flux occurs at staircase-step locations and is related to the change in poloidal flow velocity shear and to the change in the ion temperature gradient. The standard deviation, skewness and kurtosis for turbulence quantities were computed and found to be large in the vicinity of the staircase-step structures. Large values of skewness and kurtosis can be explained by a temporary opening and closing of the structure which allows turbulence intensity events to propagate. The staircase patterns may reduce the ion heat transport and a manipulation of these patterns may be used to optimize heat transport in tokamaks. An additional objective of the research in support of the Edge Physics Simulation initiative has been to improve the understanding of scrape-off layer thermal transport. In planning experiments and designing future tokamaks, it is important to understand the physical effects that contribute to divertor heat-load fluxes. The research accomplished will contribute to developing new models for the scrape-off layer region. The XGC0 code was used to compute the heat fluxes and the heat-load width in the outer divertor plates of C-Mod and DIII-D tokamaks. It was observed that the width of the XGC0 neoclassical heat-load was approximately inversely proportional to the total plasma current. Anomalous transport in the H-mode pedestal region of five Alcator C-Mod discharges, representing a collisionality scan, was analyzed. The understanding of anomalous transport in the pedestal region is important for the development of a comprehensive model for the H-mode pedestal slope. It was found that the electron thermal anomalous diffusivities at the pedestal top increase with the electron collisionality. This dependence can point to the DRIBM as the modes that drive the anomalous transport in the plasma edge of highly collisional discharges. The effects of plasma shaping on the H-mode pedestal structure was also investigated. The differences in the predicted H-mode pedestal width and height for the DIII-D discharges with different elongation and triangularities were discussed. For the discharges with higher elongation, it was found that the gradients of the plasma profiles in the H-mode pedestal reach semi-steady states. In these simulations, the pedestal slowly continued to evolve to higher pedestal pressures and bootstrap currents until the peeling ballooning stability conditions were satisfied. The discharges with lower elongation do not reach the semi-steady state, and ELM crashes were triggered at earlier times. The plasma elongation was found to have a stronger stabilizing effect than the plasma triangularity. For the discharges with lower elongation and lower triangularity, the ELM frequency was large, and the H-mode pedestal evolves rapidly. It was found that the temperature of neutrals in the scrape-off-layer region can affect the dynamics of the H-mode pedestal buildup. However, the final pedestal profiles were nearly independent of the neutral temperature. The elongation and triangularity affected the pedestal widths of plasma density and electron temperature profiles differently. This study illustrated a new mechanism for controlling the pedestal bootstrap current and the pedestal stability.

97 MATHEMATICS AND COMPUTING↗

Impact of Bone Marrow Radiation Dose on Acute Hematologic Toxicity in Cervical Cancer: Principal Component Analysis on High Dimensional Data

Purpose: To study the effects of increasing pelvic bone marrow (BM) radiation dose on acute hematologic toxicity in patients undergoing chemoradiotherapy, using a novel modeling approach to preserve the local spatial dose information. Methods and Materials: The study included 37 cervical cancer patients treated with concurrent weekly cisplatin and pelvic radiation therapy. The white blood cell count nadir during treatment was used as the indicator for acute hematologic toxicity. Pelvic BM radiation dose distributions were standardized across patients by registering the pelvic BM volumes to a common template, followed by dose remapping using deformable image registration, resulting in a dose array. Principal component (PC) analysis was applied to the dose array, and the significant eigenvectors were identified by linear regression on the PCs. The coefficients for PC regression and significant eigenvectors were represented in three dimensions to identify critical BM subregions where dose accumulation is associated with hematologic toxicity. Results: We identified five PCs associated with acute hematologic toxicity. PC analysis regression modeling explained a high proportion of the variation in acute hematologicity (adjusted R{sup 2}, 0.49). Three-dimensional rendering of a linear combination of the significant eigenvectors revealed patterns consistent with anatomical distributions of hematopoietically active BM. Conclusions: We have developed a novel approach that preserves spatial dose information to model effects of radiation dose on toxicity, which may be useful in optimizing radiation techniques to avoid critical subregions of normal tissues. Further validation of this approach in a large cohort is ongoing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Method for simulating dose reduction in digital mammography using the Anscombe transformation

Purpose: This work proposes an accurate method for simulating dose reduction in digital mammography starting from a clinical image acquired with a standard dose. Methods: The method developed in this work consists of scaling a mammogram acquired at the standard radiation dose and adding signal-dependent noise. The algorithm accounts for specific issues relevant in digital mammography images, such as anisotropic noise, spatial variations in pixel gain, and the effect of dose reduction on the detective quantum efficiency. The scaling process takes into account the linearity of the system and the offset of the detector elements. The inserted noise is obtained by acquiring images of a flat-field phantom at the standard radiation dose and at the simulated dose. Using the Anscombe transformation, a relationship is created between the calculated noise mask and the scaled image, resulting in a clinical mammogram with the same noise and gray level characteristics as an image acquired at the lower-radiation dose. Results: The performance of the proposed algorithm was validated using real images acquired with an anthropomorphic breast phantom at four different doses, with five exposures for each dose and 256 nonoverlapping ROIs extracted from each image and with uniform images. The authors simulated lower-dose images and compared these with the real images. The authors evaluated the similarity between the normalized noise power spectrum (NNPS) and power spectrum (PS) of simulated images and real images acquired with the same dose. The maximum relative error was less than 2.5% for every ROI. The added noise was also evaluated by measuring the local variance in the real and simulated images. The relative average error for the local variance was smaller than 1%. Conclusions: A new method is proposed for simulating dose reduction in clinical mammograms. In this method, the dependency between image noise and image signal is addressed using a novel application of the Anscombe transformation. NNPS, PS, and local noise metrics confirm that this method is capable of precisely simulating various dose reductions.

60 APPLIED LIFE SCIENCES↗