Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectrometers imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Optical Design of a Compact Imaging Spectrometer for Planetary Mineralogy

We present the design of a compact, wide-angle pushbroom imaging spectrometer suitable for exploration of solar system bodies from low orbit. The spectrometer is based on a single detector array with a broadband response that covers the range 400 to 3000 nm and provides a spectral sampling of 10 nm. The telescope has a 24-deg field of view with 600 spatially resolved elements (detector pixels). A specially designed convex diffraction grating permits optimization of the signal-to-noise ratio through the entire spectral band. Tolerances and design parameters permit the achievement of high uniformity of response through field and wavelength. The spectrometer performance is evaluated in terms of predicted spectral and spatial response functions and from the point of view of minimizing their variation through field and wavelength. The design serves as an example for illustrating the design principles specific to this type of system.

space optics↗

Characterization of Firefly, an Imaging Spectrometer Designed for Airborne Measurements of Solar-Induced Fluorescence

FIREFLY (Fluorescence Imaging of REd and Far-red Light Yield) is a compact, fine-resolution imaging spectrometer that was designed and assembled by Headwall Photonics (Fitchburg, MA, USA) in collaboration with NASA scientists for airborne measurements of Solar-Induced Fluorescence (SIF). FIREFLY is integrated into the next generation of NASA Goddard’s Lidar, Hyperspectral and Thermal airborne imager (G-LiHT; www.gliht.nasa.gov), providing a complete system for measuring, interpreting and scaling SIF emissions. Characterization of FIREFLY was performed here to evaluate its performance and suitability for retrieving SIF.

Imaging Spectroscopy↗

Preliminary airborne imaging spectrometer vegetation data

An airborne, pushbroom-style multispectral (1.2-2.4 micron) imaging sensor system known as Airborne Imaging Spectrometer (AIS) has been flown over the Pico Anticline region of the Santa Susana Mountains, California (U.S.A.). Initial interpretation of preliminary data sets suggest that the high spectral resolution data from AIS provide superior vegetation discrimination and mapping capabilities when compared with other imaging systems (MSS, TMS). AIS spectral data may also contain information concerning the state of health of both native and cultivated vegetation. Such capabilities (discrimination, mapping, and assessment of state of health) will be most useful in geobotanical assessment of this and other areas.

Rock, B. N.↗

Discriminating semiarid vegetation using airborne imaging spectrometer data - A preliminary assessment

A preliminary assessment was made of Airborne Imaging Spectrometer (AIS) data for discriminating and characterizing vegetation in a semiarid environment. May and October AIS data sets were acquired over a large alluvial fan in eastern California, on which were found Great Basin desert shrub communities. Maximum likelihood classification of a principal components representation of the May AIS data enabled discrimination of subtle spatial detail in images relating to vegetation and soil characteristics. The spatial patterns in the May AIS classification were, however, too detailed for complete interpretation with existing ground data. A similar analysis of the October AIS data yielded poor results. Comparison of AIS results with a similar analysis of May Landsat Thematic Mapper data showed that the May AIS data contained approximately three to four times as much spectrally coherent information. When only two shortwave infrared TM bands were used, results were similar to those from AIS data acquired in October.

Thomas, Randall W.↗

Parallel Computing for the Computed-Tomography Imaging Spectrometer

This software computes the tomographic reconstruction of spatial-spectral data from raw detector images of the Computed-Tomography Imaging Spectrometer (CTIS), which enables transient-level, multi-spectral imaging by capturing spatial and spectral information in a single snapshot.

Lee, Seungwon↗

An imaging spectrometer for the investigation of Mars

Unmanned misions to Mars will employ imaging spectrometry to yield compositional data about the target body, through visual and IR measurements of the intensity and distribution of characteristic spectral signature features in the radiation that is emitted and reflected by surface materials. Attention is presently given to a modular imaging spectrometer design with applicability to a diverse range of planetary missions. This visual and IR mapping spectrometer has been tentatively selected for NASA's recently approved Mars Observer mission. Detailed optical characteristics and capabilities of the instrument are presented.

Duval, James E.↗

Landsat-Swath Imaging Spectrometer Design

We describe the design of a high-throughput pushbroom imaging spectrometer and telescope system that is capable of Landsat swath and resolution while providing better than 10 nm per pixel spectral resolution. The design is based on a 3200 x 480 element x 18 μm pixel size focal plane array, two of which are utilized to cover the full swath. At an optical speed of F/1.8, the system is the fastest proposed to date to our knowledge. The utilization of only two spectrometer modules fed from the same telescope reduces system complexity while providing a solution within achievable detector technology. Predictions of complete system response are shown. Also, it is shown that detailed ghost analysis is a requirement for this type of spectrometer and forms an essential part of a complete design.

Dyson spectrometer↗

Land cover/use classification of Cairns, Queensland, Australia: A remote sensing study involving the conjunctive use of the airborne imaging spectrometer, the large format camera and the thematic mapper simulator

In an attempt to improve the land cover/use classification accuracy obtainable from remotely sensed multispectral imagery, Airborne Imaging Spectrometer-1 (AIS-1) images were analyzed in conjunction with Thematic Mapper Simulator (NS001) Large Format Camera color infrared photography and black and white aerial photography. Specific portions of the combined data set were registered and used for classification. Following this procedure, the resulting derived data was tested using an overall accuracy assessment method. Precise photogrammetric 2D-3D-2D geometric modeling techniques is not the basis for this study. Instead, the discussion exposes resultant spectral findings from the image-to-image registrations. Problems associated with the AIS-1 TMS integration are considered, and useful applications of the imagery combination are presented. More advanced methodologies for imagery integration are needed if multisystem data sets are to be utilized fully. Nevertheless, research, described herein, provides a formulation for future Earth Observation Station related multisensor studies.

Heric, Matthew↗

The AXAF CCD imaging spectrometer

The current status of the instrument design and the status of the CCDs being fabricated for the AXAF CCD Imaging Spectrometer (ACIS) are summarized. The instrument consists of an image recording array of CCDs and a linear arrangement of CCDs to record the spectra formed by the objective grating spectrometer. Both arrays employ CCDs with pixel dimensions which correspond to about 0.5 arcsec samples of the image. The CCDs provide moderate spectral resolution and good detection efficiency over the energy range 0.5 to 10 keV. Spectral resolution of 200 or more is achievable using the objective grating with the grating array. Radiation damage effects are shown to degrade the energy resolution of CCDs. Specially designed CCD pixel architecture is employed together with shielding and low temperature operation to slow the effects of radiation damage.

Garmire, G. P.↗

Quantitative investigations of geologic surfaces utilizing airborne visible/infrared imaging spectrometer (AVIRIS) and polarimetric radar (AIRSAR) data for Death Valley, California

Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) and polarimetric radar (AIRSAR) data were collected over Death Valley, California, USA, in September 1989. These two data sets were used to quantitatively characterize both the mineralogy and surface structure of the valley floor. Field mapping and characterization of the salt flats across the valley identified 16 separate units. The AVIRIS data were calibrated using the 'empirical line' method, and spectra extracted for the 16 units. A water vapor map was generated from the AVIRIS data and showed spatial variations in its distribution due to evaporation of surface water. Unmixing of the 16 spectral units produced maps of endmember abundance.

Kierein-Young, Kathryn S.↗

Compact Imaging Spectrometer for Planetary Missions

We report on the design performance of a compact imaging spectrometer suitable for planetary missions with U-Class spacecraft. It is a fast (F/1.9) and wide field instrument covering the range 600-3600 nm with 10 nm sampling and a 1000 pixel by 18m wide slit. The spectrometer is designed for use with a digital readout focal plane array that further aids miniaturization.

Lin, Myrtle F.↗

Acousto-optic tunable filter field spectrometer for validation of airborne and spaceborne imaging spectrometers

A new concept for a field portable spectrometer designed to meet the needs of the remote sensing community is presented. This instrument uses acoustooptic tunable filters (AOTFs) as wavelength sorters, allowing the design of a rugged, compact, light-weight tool that provides broad spectral coverage, great versatility, and ease of utilization. The spectrometer provides continuous spectral coverage from 0.4 to 2.5 microns with two channels defined by detector technology, while a visible channel covering the 0.4 to 1.0 micron spectral range uses silicon PV photodiodes. The short-wavelength IR channel covers the 0.9 to 2.5 micron special range with thermoelectrically cooled lead sulfide PC detectors.

Rider, David M.↗

Reflectance spectra from eutrophic Mono Lake California, measured with the Airborne Visible and Infrared Imaging Spectrometer (AVIRIS)

An AVIRIS image was obtained for Mono Lake, California, on May 26, 1989, a day with excellent visibility. Atmospherically-corrected reflectance spectra derived from the image indicate a spectral signature for chlorophyll a, the dominant photosynthetic pigment in the phytoplankton of the lake. Chlorophyll a concentrations in the lake were about 22 mg/cu m, and the upwelling radiance was low with a peak reflectance at about 570 nm of about 5 percent. Coherent noise appeared in the image as regular variations of 0.1 to 0.2 microwatts/sq cm per str oriented diagonally to the flight line. A simple ratio of two spectral bands removed the conspicuous undulations, but modifications of the shielding within the instrument are needed to improve the signal especially over dark targets such as lakes.

Melack, John M.↗

Ultraviolet Imaging Spectrometer

Wide-field imaging systems equipped with objective prisms or gratings have had a long history of utility in groundbased observations of meteors and comets. Deployment of similar instruments from low Earth orbit would allow the first UV observations of meteors. This instrument can be used for comets and Lyman alpha coronae of Earth-orbit-crossing asteroids. A CaF2 prism imaging spectrograph designed for stellar observations was used aboard Skylab to observe Comet Kohoutek (1973f), but its 1300-A cut-off precluded Lyman alpha images and it was not used for observation of meteors. Because the observation of the UV spectrum of a meteor has never been attempted, researchers are denied the opportunity to obtain composition information from spectra at those wavelengths. We propose construction of a flight instrument functioning in the 1100-3200 A spectral range that is suitable for a dedicated satellite ('Quick Star') or as a space-station-attached payload. It can also be an autonomous package in the space shuttle cargo bay.

Wdowiak, T. J.↗

Calibration of the Airborne Visible/Infrared Imaging Spectrometer in the Laboratory

Imaging spectrometry data must be spectrally, radiometrically and geometrically calibrated in order to: 1) derive physical parameters from measured spectral radiance, 2) compare data acquired from different regions and at different times, 3) compare and analyze the imaging spectrometry data with data acquired from other calibrated sensors, and 4) compare and analyze data with results from computer models. The calibration of AVIRIS data is the process by which laboratory characterization data are applied to raw instrument data (digitized number versus spectral channels) to produce quantitative spectra (radiance versus wavelength) for each image pixel in units of spectral radiance. The AVIRIS sensor and calibration process are described by Vane and the application of the calibration data to the raw digital data is described by Green. This calibration process is validated for in-flight performance of the sensor using a rigorous ground-truth campaign. This workshop paper reviews the laboratory characterization data set that is used in the AVIRIS calibration process. The laboratory measurements used to acquire the calibration data are divided into three classes: 1) spectral calibration, 2) radiometric calibration, and 3) spatial calibration.

Green Robert O.↗

Comparison of Landsat Thematic Mapper and Geophysical and Environmental Research Imaging Spectrometer data for the Cuprite mining district, Esmeralda, and Nye counties, Nevada

Landsat TM images and Geophysical and Environmental Research Imaging Spectrometer (GERIS) data were analyzed for the Cuprite mining district and compared to available geologic and alteration maps of the area. The TM data, with 30 m resolution and 6 broadbands, allowed discrimination of general mineral groups. Clay minerals, playa deposits, and unaltered rocks were mapped as discrete spectral units using the TM data, but specific minerals were not determined, and definition of the individual alteration zones was not possible. The GERIS, with 15 m spatial resolution and 63 spectral bands, permitted construction of complete spectra and identification of specific minerals. Detailed spectra extracted from the images provided the ability to identify the minerals alunite, kaolinite, hematite, and buddingtonite by their spectral characteristics. The GERIS data show a roughly concentrically zoned hydrothermal system. The mineralogy mapped with the aircraft system conforms to previous field and multispectral image mapping. However, identification of individual minerals and spatial display of the dominant mineralogy add information that can be used to help determine the morphology and genetic origin of the hydrothermal system.

Kierein-Young, Kathryn S.↗