Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spatial transferability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Characterization of electron microscopes with binary pseudo-random multilayer test samples

Verification of the reliability of metrology data from high quality X-ray optics requires that adequate methods for test and calibration of the instruments be developed. For such verification for optical surface profilometers in the spatial frequency domain, a modulation transfer function (MTF) calibration method based on binarypseudo-random (BPR) gratings and arrays has been suggested and and proven to be an effective calibration method for a number of interferometric microscopes, a phase shifting Fizeau interferometer, and a scatterometer. Here we describe the details of development of binarypseudo-random multilayer (BPRML) test samples suitable for characterization of scanning (SEM) and transmission (TEM) electron microscopes. We discuss the results of TEM measurements with the BPRML test samples fabricated from a WiSi{sub 2}/Si multilayer coating with pseudo-randomly distributed layers. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML testsamples can be used to characterize X-ray microscopes. Corresponding work with X-ray microscopes is in progress.

36 MATERIALS SCIENCE↗

Characterization of electron microscopes with binary pseudo-random multilayer test samples

Verification of the reliability of metrology data from high quality x-ray optics requires that adequate methods for test and calibration of the instruments be developed. For such verification for optical surface profilometers in the spatial frequency domain, a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays has been suggested [Proc. SPIE 7077-7 (2007), Opt. Eng. 47(7), 073602-1-5 (2008)} and proven to be an effective calibration method for a number of interferometric microscopes, a phase shifting Fizeau interferometer, and a scatterometer [Nucl. Instr. and Meth. A 616, 172-82 (2010)]. Here we describe the details of development of binary pseudo-random multilayer (BPRML) test samples suitable for characterization of scanning (SEM) and transmission (TEM) electron microscopes. We discuss the results of TEM measurements with the BPRML test samples fabricated from a WiSi2/Si multilayer coating with pseudo randomly distributed layers. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML test samples can be used to characterize x-ray microscopes. Corresponding work with x-ray microscopes is in progress.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE MISSING CAVITIES IN THE SEEDS POLARIZED SCATTERED LIGHT IMAGES OF TRANSITIONAL PROTOPLANETARY DISKS: A GENERIC DISK MODEL

Transitional circumstellar disks around young stellar objects have a distinctive infrared deficit around 10 {mu}m in their spectral energy distributions, recently measured by the Spitzer Infrared Spectrograph (IRS), suggesting dust depletion in the inner regions. These disks have been confirmed to have giant central cavities by imaging of the submillimeter continuum emission using the Submillimeter Array (SMA). However, the polarized near-infrared scattered light images for most objects in a systematic IRS/SMA cross sample, obtained by HiCIAO on the Subaru telescope, show no evidence for the cavity, in clear contrast with SMA and Spitzer observations. Radiative transfer modeling indicates that many of these scattered light images are consistent with a smooth spatial distribution for {mu}m-sized grains, with little discontinuity in the surface density of the {mu}m-sized grains at the cavity edge. Here we present a generic disk model that can simultaneously account for the general features in IRS, SMA, and Subaru observations. Particularly, the scattered light images for this model are computed, which agree with the general trend seen in Subaru data. Decoupling between the spatial distributions of the {mu}m-sized dust and mm-sized dust inside the cavity is suggested by the model, which, if confirmed, necessitates a mechanism, such as dust filtration, for differentiating the small and big dust in the cavity clearing process. Our model also suggests an inwardly increasing gas-to-dust ratio in the inner disk, and different spatial distributions for the small dust inside and outside the cavity, echoing the predictions in grain coagulation and growth models.

79 ASTRONOMY AND ASTROPHYSICS↗

Anisotropic Energy Transfer and Conversion in Magnetized Compressible Turbulence

We present a spatial filtering (or coarse-graining) analysis on 3D magnetized magnetohydrodynamic (MHD) turbulence simulations. The filtered compressible MHD formulae show transfer of kinetic and magnetic energies from large to small scales, as well as energy conversion between kinetic, magnetic, and thermal energies. The anisotropic filtering enables separate analyses of the energy flows perpendicular and parallel to the global mean magnetic field. Anisotropy in energy cascade is demonstrated by the larger perpendicular energy cascade rate and also the larger perpendicular wavenumbers associated with the peak energy transfer rate. We also find that the “inertial range” along the parallel (perpendicular) direction in the anisotropic energy cascade formulation is no longer strictly dissipation-free, because it includes the dissipation in the perpendicular (parallel) direction. A change in the driving force (kinetic only versus kinetic and magnetic) affects the energy conversion between kinetic and magnetic energies. While the compressibility of the driving force changes the partition of different channels of energy transfer and conversion, and also increases the total energy transfer rate, the global energy flow remains unaffected by compressibility qualitatively. Our analysis can be applied to multispacecraft observations of turbulence in the solar wind or a planetary magnetosphere.

79 ASTRONOMY AND ASTROPHYSICS↗

Three-dimensional anisotropic adaptive filtering of projection data for noise reduction in cone beam CT

Purpose: The combination of quickly rotating C-arm gantry with digital flat panel has enabled the acquisition of three-dimensional data (3D) in the interventional suite. However, image quality is still somewhat limited since the hardware has not been optimized for CT imaging. Adaptive anisotropic filtering has the ability to improve image quality by reducing the noise level and therewith the radiation dose without introducing noticeable blurring. By applying the filtering prior to 3D reconstruction, noise-induced streak artifacts are reduced as compared to processing in the image domain. Methods: 3D anisotropic adaptive filtering was used to process an ensemble of 2D x-ray views acquired along a circular trajectory around an object. After arranging the input data into a 3D space (2D projections + angle), the orientation of structures was estimated using a set of differently oriented filters. The resulting tensor representation of local orientation was utilized to control the anisotropic filtering. Low-pass filtering is applied only along structures to maintain high spatial frequency components perpendicular to these. The evaluation of the proposed algorithm includes numerical simulations, phantom experiments, and in-vivo data which were acquired using an AXIOM Artis dTA C-arm system (Siemens AG, Healthcare Sector, Forchheim, Germany). Spatial resolution and noise levels were compared with and without adaptive filtering. A human observer study was carried out to evaluate low-contrast detectability. Results: The adaptive anisotropic filtering algorithm was found to significantly improve low-contrast detectability by reducing the noise level by half (reduction of the standard deviation in certain areas from 74 to 30 HU). Virtually no degradation of high contrast spatial resolution was observed in the modulation transfer function (MTF) analysis. Although the algorithm is computationally intensive, hardware acceleration using Nvidia's CUDA Interface provided an 8.9-fold speed-up of the processing (from 1336 to 150 s). Conclusions: Adaptive anisotropic filtering has the potential to substantially improve image quality and/or reduce the radiation dose required for obtaining 3D image data using cone beam CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single-Molecule Interfacial Electron Transfer

This project is focused on the use of single-molecule high spatial and temporal resolved techniques to study molecular dynamics in condensed phase and at interfaces, especially, the complex reaction dynamics associated with electron and energy transfer rate processes. The complexity and inhomogeneity of the interfacial ET dynamics often present a major challenge for a molecular level comprehension of the intrinsically complex systems, which calls for both higher spatial and temporal resolutions at ultimate single-molecule and single-particle sensitivities. Combined single-molecule spectroscopy and electrochemical atomic force microscopy approaches are unique for heterogeneous and complex interfacial electron transfer systems because the static and dynamic inhomogeneities can be identified and characterized by studying one molecule at a specific nanoscale surface site at a time. The goal of our project is to integrate and apply these spectroscopic imaging and topographic scanning techniques to measure the energy flow and electron flow between molecules and substrate surfaces as a function of surface site geometry and molecular structure. We have been primarily focusing on studying interfacial electron transfer under ambient condition and electrolyte solution involving both single crystal and colloidal TiO 2 and related substrates. The resulting molecular level understanding of the fundamental interfacial electron transfer processes will be important for developing efficient light harvesting systems and broadly applicable to problems in fundamental chemistry and physics. We have made significant advancement on deciphering the underlying mechanism of the complex and inhomogeneous interfacial electron transfer dynamics in dyesensitized TiO 2 nanoparticle systems that strongly involves with and regulated by molecule-surface interactions. We have studied interfacial electron transfer on TiO 2 nanoparticle surfaces by using ultrafast single-molecule spectroscopy and electrochemical AFM metal tip scanning microscopy, focusing on understanding the interfacial electron transfer dynamics at specific nanoscale electron transfer sites with high-spatially and temporally resolved topographic-and-spectroscopic characterization at individual molecule basis, characterizing single-molecule rate processes, reaction driving force, and molecule-substrate electronic coupling. One of the most significant characteristics of our new approach is that we are able to interrogate the complex interfacial electron transfer dynamics by actively pin-point energetic manipulation of the surface interaction and electronic couplings, beyond the conventional excitation and observation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling of crystallization fouling on a horizontal-tube falling-film evaporator for thermal desalination

Scale formation within horizontal-tube falling-film evaporators is an important issue for thermal desalination, because of the deterioration of heat transfer performance and added maintenance costs. Predicting the fouling process is crucial for desalination plant design, operation, and maintenance. In this paper, a model is developed to predict the crystallization fouling process during seawater falling-film flow over a horizontal tube bundle. The scaling is estimated based on deposition theory, with couple heat transfer including the in-tube steam condensation, conduction through the tube wall and the scale layer, and falling-film evaporation. The spatial and temporal variations of temperature, heat transfer coefficient, and scale thickness are predicted, and the effects of variations in process parameters of steam, feed seawater, and tube properties on the scale thickness, evaporation rate, and heat transfer coefficient for falling-film evaporation are analyzed. Comparisons to existing experimental data show the scaling layer thickness falls in the general range of reported measurements, with a slight overestimation due to neglecting the delay of scaling onset under real conditions. The scale layer thickness increases dramatically as the in-tube steam pressure is increased or the seawater flow rate is decreased. In general, the scaling layer becomes thicker on the lower tubes in the tube bundle, due to the heat and mass transfer of the falling film. The effect of tube material on scaling appears mainly dependent on thermal conductivity; thus, using polymer rather than a stainless steel tube decreases scaling and evaporation rate 96% and 88%, respectively. Finally, this work has potential to guide thermal desalination plant design, material selection, and operating parameter optimization.

42 ENGINEERING↗

Thermal Emission in the Southwest Clump of VY CMa

We present high spatial resolution LBTI/NOMIC 9–12 μm images of VY CMa and its massive outflow feature, the Southwest (SW) Clump. Combined with high-resolution imaging from the Hubble Space Telescope (0.4–1 μm) and LBT/LMIRCam (1–5μm), we isolate the spectral energy distribution (SED) of the clump from the star itself. Using radiative-transfer code DUSTY, we model both the scattered light from VY CMa and the thermal emission from the dust in the clump to estimate the optical depth, mass, and temperature of the SW Clump. The SW Clump is optically thick at 8.9 μm with a brightness temperature of ∼200 K. With a dust chemistry of equal parts silicates and metallic iron, as well as assumptions on grain size distribution, we estimate a dust mass of 5.4 × 10{sup −5} M{sub ⊙}. For a gas-to-dust ratio of 100, this implies a total mass of 5.4 × 10{sup −3} M{sub ⊙}. Compared to the typical mass-loss rate of VY CMa, the SW Clump represents an extreme, localized mass-loss event from ≲300 yr ago.

79 ASTRONOMY AND ASTROPHYSICS↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with significantly curved x-ray optics

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. The current capabilities and possibility for improvements in X-ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. In the case of Fizeau interferometry, metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for measuring slightly curved X-ray optics. However, for even moderately curved aspherical X-ray mirrors the flat-reference calibration is not sufficiently accurate and stitching Fizeau interferometer-based surface metrology is used to mitigate the problem. But still, the retrace and aberration errors, as well as the limited spatial resolution, described with the instrument transfer function (ITF), can be transferred into the optical surface topography of X-ray mirrors obtained in stitching metrology. For ITF calibration, we have developed an original technique, based on test standards structured as two-dimensional (2D) highly-randomized (HR) binary pseudo-random arrays (BPRAs). The technique employs the unique properties of the HR BPRA patterns in the spatial frequency domain., i.e. the inherent 2D power spectral density of the HR BPRA pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. Here, we explore technological, metrological, and analytical aspects essential for calibration of the retrace and aberration errors of Fizeau interferometers using different types of tilted test samples, including a super-polished reference mirror for the re-trace calibration and the uniformly redundant array (URA) BPRA standards for the geometrical distortion (aberration) calibration. While the first method was previously demonstrated by researchers at DIAMOND Light Source, a method based on the URA BPRA is described and demonstrated here for the first time. We outline the design and fabrication process used in fabrication of URA BPRA test standards, and present the results of application of the URA BPRA standards demonstrating the high efficacy of our approach to geometrical distortion calibration of Fizeau interferometers. We also discuss the possible sources of unexpected peculiarities of the systematic errors, including an astigmatic character of the retrace error, observed with Fizeau interferometers at the Advanced Light Source X-Ray Optics Laboratory.

Munechika, Keiko↗

RADIATIVE TRANSFER MODELING OF Ly{alpha} EMITTERS. I. STATISTICS OF SPECTRA AND LUMINOSITY

We combine a cosmological reionization simulation with box size of 100 h {sup -1} Mpc on a side and a Monte Carlo Ly{alpha} radiative transfer code to model Ly{alpha} Emitters (LAEs) at z {approx} 5.7. The model introduces Ly{alpha} radiative transfer as the single factor for transforming the intrinsic Ly{alpha} emission properties into the observed ones. Spatial diffusion of Ly{alpha} photons from radiative transfer results in extended Ly{alpha} emission and only the central part with high surface brightness can be observed. Because of radiative transfer, the appearance of LAEs depends on density and velocity structures in circumgalactic and intergalactic media as well as the viewing angle, which leads to a broad distribution of apparent (observed) Ly{alpha} luminosity for a given intrinsic Ly{alpha} luminosity. Radiative transfer also causes frequency diffusion of Ly{alpha} photons. The resultant Ly{alpha} line is asymmetric with a red tail. The peak of the Ly{alpha} line shifts toward longer wavelength and the shift is anti-correlated with the apparent-to-intrinsic Ly{alpha} luminosity ratio. The simple radiative transfer model provides a new framework for studying LAEs. It is able to explain an array of observed properties of z {approx} 5.7 LAEs in Ouchi et al., producing Ly{alpha} spectra, morphology, and apparent Ly{alpha} luminosity function (LF) similar to those seen in observation. The broad distribution of apparent Ly{alpha} luminosity at fixed UV luminosity provides a natural explanation for the observed UV LF, especially the turnover toward the low luminosity end. The model also reproduces the observed distribution of Ly{alpha} equivalent width (EW) and explains the deficit of UV bright, high EW sources. Because of the broad distribution of the apparent-to-intrinsic Ly{alpha} luminosity ratio, the model predicts effective duty cycles and Ly{alpha} escape fractions for LAEs.

79 ASTRONOMY AND ASTROPHYSICS↗

Signal and noise transfer properties of CMOS based active pixel flat panel imager coupled to structured CsI:Tl

Complementary metal-oxide-semiconductors (CMOS) active pixel sensors can be optically coupled to CsI:Tl phosphors forming a indirect active pixel flat panel imager (APFPI) for high performance medical imaging. The aim of this work is to determine the x-ray imaging capabilities of CMOS-based APFPI and study the signal and noise transfer properties of CsI:Tl phosphors. Three different CsI:Tl phosphors from two different vendors have been used to produce three system configurations. The performance of each system configuration has been studied in terms of the modulation transfer function (MTF), noise power spectra, and detective quantum efficiency (DQE) in the mammographic energy range. A simple method to determine quantum limited systems in this energy range is also presented. In addition, with aid of monochromatic synchrotron radiation, the effect of iodine characteristic x-rays of the CsI:Tl on the MTF has been determined. A Monte Carlo simulation of the signal transfer properties of the imager is also presented in order to study the stages that degrade the spatial resolution of our current system. The effect of using substrate patterning during the growth of CsI:Tl columnar structure was also studied, along with the effect of CsI:Tl fixed pattern noise due to local variations in the scintillation light. CsI:Tl fixed pattern noise appears to limit the performance of our current system configurations. All the system configurations are quantum limited at 0.23 {mu}C/kg with two of them having DQE (0) equal to 0.57. Active pixel flat panel imagers are shown to be digital x-ray imagers with almost constant DQE throughout a significant part of their dynamic range and in particular at very low exposures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessing the validity of modulation transfer function evaluation techniques with application to small area and scanned digital detectors

A novel prototype step and shoot x-ray system, the intelligent imaging system (I-Imas), has been developed in the UCL Radiation Physics laboratories. The system uses collimators to split the beam into two: the first, 'scout' beam, strongly attenuated, identifies regions of interest in the image. This information is then fed back to the system so that the intensity of the second beam is modulated to optimize the dose distribution--i.e., ''interesting'' regions of the sample receive a higher dose, whereas other regions receive a lower one. Such systems may be capable of improved diagnostic capability at the same overall patient dose levels as typical when using large area digital plates. This acquisition mode means that large overall images are obtained by aligning many smaller images. This paper investigates the effects that this acquisition modality has on the overall spatial resolution of the system. We review different modulation transfer function (MTF) evaluation techniques and those shown to be optimal are used in the investigation of two considerations key to such a system: (i) whether there is a minimum size sensor whose MTF can accurately be determined using these techniques and (ii) whether the MTF of the large overall image differs significantly from those of the many constituent images. As the use of step and shoot systems is becoming more and more widespread, both are important considerations. We found that, for a fixed pixel pitch, the MTF is determined marginally less accurately the smaller the sensor area, with the perceived resolution varying by up to 0.1 lp/mm. It was also found that use of such a step and shoot technique does cause a very small overall degradation in resolution. The resolution of overall images was calculated to be 0.1 lp/mm lower than that of the individual images acquired.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a commercial hybrid iterative and model-based reconstruction algorithm in radiation oncology

Purpose: Iterative reconstruction (IR) reduces noise, thereby allowing dose reduction in computed tomography (CT) while maintaining comparable image quality to filtered back-projection (FBP). This study sought to characterize image quality metrics, delineation, dosimetric assessment, and other aspects necessary to integrate IR into treatment planning. Methods: CT images (Brilliance Big Bore v3.6, Philips Healthcare) were acquired of several phantoms using 120 kVp and 25–800 mAs. IR was applied at levels corresponding to noise reduction of 0.89–0.55 with respect to FBP. Noise power spectrum (NPS) analysis was used to characterize noise magnitude and texture. CT to electron density (CT-ED) curves were generated over all IR levels. Uniformity as well as spatial and low contrast resolution were quantified using a CATPHAN phantom. Task specific modulation transfer functions (MTF{sub task}) were developed to characterize spatial frequency across objects of varied contrast. A prospective dose reduction study was conducted for 14 patients undergoing interfraction CT scans for high-dose rate brachytherapy. Three physicians performed image quality assessment using a six-point grading scale between the normal-dose FBP (reference), low-dose FBP, and low-dose IR scans for the following metrics: image noise, detectability of the vaginal cuff/bladder interface, spatial resolution, texture, segmentation confidence, and overall image quality. Contouring differences between FBP and IR were quantified for the bladder and rectum via overlap indices (OI) and Dice similarity coefficients (DSC). Line profile and region of interest analyses quantified noise and boundary changes. For two subjects, the impact of IR on external beam dose calculation was assessed via gamma analysis and changes in digitally reconstructed radiographs (DRRs) were quantified. Results: NPS showed large reduction in noise magnitude (50%), and a slight spatial frequency shift (∼0.1 mm{sup −1}) with application of IR at L6. No appreciable changes were observed for CT-ED curves between FBP and IR levels [maximum difference ∼13 HU for bone (∼1% difference)]. For uniformity, differences were ∼1 HU between FBP and IR. Spatial resolution was well conserved; the largest MTF{sub task} decrease between FBP and IR levels was 0.08 A.U. No notable changes in low-contrast detectability were observed and CNR increased substantially with IR. For the patient study, qualitative image grading showed low-dose IR was equivalent to or slightly worse than normal dose FBP, and is superior to low-dose FBP (p < 0.001 for noise), although these did not translate to differences in CT number, contouring ability, or dose calculation. The largest CT number discrepancy from FBP occurred at a bone/tissue interface using the most aggressive IR level [−1.2 ± 4.9 HU (range: −17.6–12.5 HU)]. No clinically significant contour differences were found between IR and FBP, with OIs and DSCs ranging from 0.85 to 0.95. Negligible changes in dose calculation were observed. DRRs preserved anatomical detail with <2% difference in intensity from FBP combined with aggressive IRL6. Conclusions: These results support integrating IR into treatment planning. While slight degradation in edges and shift in texture were observed in phantom, patient results show qualitative image grading, contouring ability, and dosimetric parameters were not adversely affected.

60 APPLIED LIFE SCIENCES↗

Three Radial Gaps in the Disk of TW Hydrae Imaged with SPHERE

We present scattered light images of the TW Hya disk performed with the Spectro-Polarimetric High-contrast Exoplanet REsearch instrument in Polarimetric Differential Imaging mode at 0.63, 0.79, 1.24, and 1.62 μm. We also present H2/H3-band angular differential imaging (ADI) observations. Three distinct radial depressions in the polarized intensity distribution are seen, around ≈85, ≈21, and ≲6 au.{sup 21} The overall intensity distribution has a high degree of azimuthal symmetry; the disk is somewhat brighter than average toward the south and darker toward the north–west. The ADI observations yielded no signifiant detection of point sources in the disk. Our observations have a linear spatial resolution of 1–2 au, similar to that of recent ALMA dust continuum observations. The sub-micron-sized dust grains that dominate the light scattering in the disk surface are strongly coupled to the gas. We created a radiative transfer disk model with self-consistent temperature and vertical structure iteration and including grain size-dependent dust settling. This method may provide independent constraints on the gas distribution at higher spatial resolution than is feasible with ALMA gas line observations. We find that the gas surface density in the “gaps” is reduced by ≈50% to ≈80% relative to an unperturbed model. Should embedded planets be responsible for carving the gaps then their masses are at most a few 10 M{sub ⊕}. The observed gaps are wider, with shallower flanks, than expected for planet–disk interaction with such low-mass planets. If forming planetary bodies have undergone collapse and are in the “detached phase,” then they may be directly observable with future facilities such as the Mid-Infrared E-ELT Imager and Spectrograph at the E-ELT.

79 ASTRONOMY AND ASTROPHYSICS↗

A new indirect measure of diffusion model error

We define a new indirect measure of the diffusion model error called the diffusion model error source. When this model error source is added to the diffusion equation, the transport solution for the angular-integrated intensity is obtained. This source represents a means by which a transport code can be used to generate information relating to the adequacy of diffusion theory for any given problem without actually solving the diffusion equation. The generation of this source does not relate in any way to acceleration of the iterative convergence of transport solutions. Perhaps the most well-known indirect measure of the diffusion model error is the variable-Eddington tensor. This tensor provides a great deal of information about the angular dependence of the angular intensity solution, but it is not always simple to interpret. In contrast, our diffusion model error source is a scalar that is conceptually easy to understand. In addition to defining the diffusion model error source analytically, we show how to generate this source numerically relative to the S{sub n} radiative transfer equations with linear-discontinuous spatial discretization. This numerical source is computationally tested and shown to reproduce the Sn solution for a Marshak-wave problem. (authors)

97 MATHEMATICS AND COMPUTING↗

ISOTROPIC MID-INFRARED EMISSION FROM THE CENTRAL 100 pc OF ACTIVE GALAXIES

Dust reprocesses the intrinsic radiation of active galactic nuclei (AGNs) to emerge at longer wavelengths. The observed mid-infrared (MIR) luminosity depends fundamentally on the luminosity of the central engine, but in detail it also depends on the geometric distribution of the surrounding dust. To quantify this relationship, we observe nearby normal AGNs in the MIR to achieve spatial resolution better than 100 pc, and we use absorption-corrected X-ray luminosity as a proxy for the intrinsic AGN emission. We find no significant difference between optically classified Seyfert 1 and 2 galaxies. Spectroscopic differences, both at optical and IR wavelengths, indicate that the immediate surroundings of AGNs are not spherically symmetric, as in standard unified AGN models. A quantitative analysis of clumpy torus radiative transfer models shows that a clumpy local environment can account for this dependence on viewing geometry while producing MIR continuum emission that remains nearly isotropic, as we observe, although the material is not optically thin at these wavelengths. We find some luminosity dependence on the X-ray/MIR correlation in the smallest scale measurements, which may indicate enhanced dust emission associated with star formation, even on these sub-100 pc scales.

79 ASTRONOMY AND ASTROPHYSICS↗

Load partitioning in Ai{sub 2}0{sub 3-}Al composites with three- dimensional periodic architecture.

Interpenetrating composites are created by infiltration of liquid aluminum into three-dimensional (3-D) periodic Al{sub 2}O{sub 3} preforms with simple tetragonal symmetry produced by direct-write assembly. Volume-averaged lattice strains in the Al{sub 2}O{sub 3} phase of the composite are measured by synchrotron X-ray diffraction for various uniaxial compression stresses up to -350MPa. Load transfer, found by diffraction to occur from the metal phase to the ceramic phase, is in general agreement with simple rule-of-mixture models and in better agreement with more complex, 3-D finite-element models that account for metal plasticity and details of the geometry of both phases. Spatially resolved diffraction measurements show variations in load transfer at two different positions within the composite.

43 PARTICLE ACCELERATORS↗

A continuum-atomistic simulation of heat transfer in micro- and nano-flows

We develop a hybrid atomistic-continuum scheme for simulating micro- and nano-flows with heat transfer. The approach is based on spatial 'domain decomposition' in which molecular dynamics (MD) is used in regions where atomistic details are important, while classical continuum fluid dynamics is used in the remaining regions. The two descriptions are matched in a coupling region where we ensure continuity of mass, momentum, energy and their fluxes. The scheme for including the energy equation is implemented in 1-D and 2-D, and used to study steady and unsteady heat transfer in channel flows with and without nano roughness. Good agreement between hybrid results and analytical or pure MD results is found, demonstrating the accuracy of this multiscale method and its potential applications in thermal engineering.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗