Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Replacing fish oil and astaxanthin by microalgal sources produced different metabolic responses in juvenile rainbow trout fed 2 types of practical diets

Dietary fish oil supplementation provides n-3 long-chained polyunsaturated fatty acids for supporting fish growth and metabolism and enriching fillet with eicosapentaenoic acid (EPA; 20:5n-3) and docosahexaenoic acid (DHA; c22:6n-3). Two experiments were performed as a 3 × 2 factorial arrangement of dietary treatments for 16 wk to determine effects and mechanisms of replacing 0%, 50%, and 100% fish oil with DHA-rich microalgae in combination with synthetic vs. microalgal source of astaxanthin in plant protein meal (PM)- or fishmeal (FM)- based diets for juvenile rainbow trout (Oncorhynchus mykiss). Fish (22 ± 0.26 g) were stocked at 17/tank and 3 tanks/diet. The 100% fish oil replacement impaired (P < 0.0001) growth performance, dietary protein and energy utilization, body indices, and tissue accumulation of DHA and EPA in both diet series. Here, the impairments were associated (P < 0.05) with upregulation of hepatic gene expression related to growth (ghr1and igf1) and biosynthesis of DHA and EPA (fads6 and evol5) that was more dramatic in the FM than PM diet-fed fish, and more pronounced on tissue EPA than DHA concentrations. The source of astaxanthin exerted interaction effects with the fish oil replacement on several measures including muscle total cholesterol concentrations. In conclusion, replacing fish oil by the DHA-rich microalgae produced more negative metabolic responses than the substitution of synthetic astaxanthin by the microalgal source in juvenile rainbow trout fed 2 types of practical diets.

59 BASIC BIOLOGICAL SCIENCES↗

Source size measurement options for low-emittance light sources

Radiation-based techniques for measuring electron source sizes are widely used as emittance diagnostics at existing synchrotron sources. Three of these techniques, namely, pinhole imaging, double-slit interferometry, and a K-edge filter-based beam position and size monitor system (ps-BPM), are evaluated for measuring source sizes at low-emittance storage rings. Each technique is reviewed with a detailed system description, design optimization, and practical considerations targeted for small source sizes. Pinhole imaging has the simplest setup and gives the beam profile in both transverse dimensions but with limited resolution. Double-slit interferometry has the highest resolution but with a limited detectable size range. The ps-BPM system shows reasonable resolution for monitoring small source sizes and divergence and can give real-time information of the source position and angle. New facilities may consider an integrated system that combines some or all of these techniques.

43 PARTICLE ACCELERATORS↗

Temporal resolution and motion artifacts in single-source and dual-source cardiac CT

Purpose: The temporal resolution of a given image in cardiac computed tomography (CT) has so far mostly been determined from the amount of CT data employed for the reconstruction of that image. The purpose of this paper is to examine the applicability of such measures to the newly introduced modality of dual-source CT as well as to methods aiming to provide improved temporal resolution by means of an advanced image reconstruction algorithm. Methods: To provide a solid base for the examinations described in this paper, an extensive review of temporal resolution in conventional single-source CT is given first. Two different measures for assessing temporal resolution with respect to the amount of data involved are introduced, namely, either taking the full width at half maximum of the respective data weighting function (FWHM-TR) or the total width of the weighting function (total TR) as a base of the assessment. Image reconstruction using both a direct fan-beam filtered backprojection with Parker weighting as well as using a parallel-beam rebinning step are considered. The theory of assessing temporal resolution by means of the data involved is then extended to dual-source CT. Finally, three different advanced iterative reconstruction methods that all use the same input data are compared with respect to the resulting motion artifact level. For brevity and simplicity, the examinations are limited to two-dimensional data acquisition and reconstruction. However, all results and conclusions presented in this paper are also directly applicable to both circular and helical cone-beam CT. Results: While the concept of total TR can directly be applied to dual-source CT, the definition of the FWHM of a weighting function needs to be slightly extended to be applicable to this modality. The three different advanced iterative reconstruction methods examined in this paper result in significantly different images with respect to their motion artifact level, despite exactly the same amount of data being used in the reconstruction process. Conclusions: The concept of assessing temporal resolution by means of the data employed for reconstruction can nicely be extended from single-source to dual-source CT. However, for advanced (possibly nonlinear iterative) reconstruction algorithms the examined approach fails to deliver accurate results. New methods and measures to assess the temporal resolution of CT images need to be developed to be able to accurately compare the performance of such algorithms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acoustic Source Localization via Time Difference of Arrival Estimation for Distributed Sensor Networks Using Tera‐Scale Optical Core Devices

For real‐time acoustic source localization applications, one of the primary challenges is the considerable growth in computational complexity associated with the emergence of ever larger, active or passive, distributed sensor networks. These sensors rely heavily on battery‐operated system components to achieve highly functional automation in signal and information processing. In order to keep communication requirements minimal, it is desirable to perform as much processing on the receiver platforms as possible. However, the complexity of the calculations needed to achieve accurate source localization increases dramatically with the size of sensor arrays, resulting in substantial growth of computational requirements that cannot be readily met with standard hardware. One option to meet this challenge builds upon the emergence of digital optical‐core devices. The objective of this work was to explore the implementation of key building block algorithms used in underwater source localization on the optical‐core digital processing platform recently introduced by Lenslet Inc. This demonstration of considerably faster signal processing capability should be of substantial significance to the design and innovation of future generations of distributed sensor networks.

Imam, Neena↗

Mapping Correlation of a Simulated Dark Matter Source and a Point Source in the Gamma-Ray Sky - Oral Presentation [Slides]

In my research, I analyzed how two gamma-ray source models interact with one another when optimizing to fit data. This is important because it becomes hard to distinguish between the two point sources when they are close together or looking at low energy photons. The reason for the first is obvious, the reason why they become harder to distinguish at lower photon energies is the resolving power of the Fermi Gamma-Ray Space Telescope gets worse at lower energies. When the two point sources are highly correlated (hard to distinguish between), we need to change our method of statistical analysis. What I did was show that highly correlated sources have larger uncertainties associated with them, caused by an optimizer not knowing which point source’s parameters to optimize. I also mapped out where their is high correlation for 2 different theoretical mass dark matter point sources so that people analyzing them in the future knew where they had to use more sophisticated statistical analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Inverting infrasound data for the seismoacoustic source time functions and surface spall at the Source Physics Experiments Phase II: Dry Alluvium Geology

This report presents the infrasound data recorded as part of the Source Physics Experiment - Phase 2, Dry Alluvium Geology. This experiment, also known colloquially as DAG, consisted of four underground chemical explosions at the Nevada National Security Site. We focus our analysis on only the fourth explosion (DAG-4) as we determined that this was the only event that produced clear source-generated infrasound energy as recorded by the DAG sensors. We analyze the data using two inversion methods. The first method is designed to estimate the point-source seismoacoustic source time functions, and the second inversion method is designed to estimate the first-order characteristics (e.g. horizontal dimensions and maximum amplitude) of the actual spall surface. For both analysis methods, we are able to fit the data reasonably well, with various assumptions of the source model. The estimated seismoacoustic source appears to be a combination of a buried, isotropic explosion with a maximum amplitude of ~2 x 10 9 Nm and a vertically oriented force, applied to the Earth's surface with a maximum amplitude of 4 x 10 7 N. We use the vertically oriented force to simulate surface spall. The estimated spall surface has an approximate radius of ~40 m with a maximum acceleration magnitude in the range of 0.8 to 1.5 m/s/s. These estimates are approximately similar to the measured surface acceleration at the site.

58 GEOSCIENCES↗

All-sky Search for Time-integrated Neutrino Emission from Astrophysical Sources with 7 yr of IceCube Data

Since the recent detection of an astrophysical flux of high-energy neutrinos, the question of its origin has not yet fully been answered. Much of what is known about this flux comes from a small event sample of high neutrino purity, good energy resolution, but large angular uncertainties. In searches for point-like sources, on the other hand, the best performance is given by using large statistics and good angular reconstructions. Track-like muon events produced in neutrino interactions satisfy these requirements. We present here the results of searches for point-like sources with neutrinos using data acquired by the IceCube detector over 7 yr from 2008 to 2015. The discovery potential of the analysis in the northern sky is now significantly below E{sub ν}{sup 2}dϕ/dE{sub ν} = 10{sup −12} TeV cm{sup −2} s{sup −1}, on average 38% lower than the sensitivity of the previously published analysis of 4 yr exposure. No significant clustering of neutrinos above background expectation was observed, and implications for prominent neutrino source candidates are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

A source-attractor approach to network detection of radiation sources

Radiation source detection using a network of detectors is an active field of research for homeland security and defense applications. We propose Source-attractor Radiation Detection (SRD) method to aggregate measurements from a network of detectors for radiation source detection. SRD method models a potential radiation source as a magnet -like attractor that pulls in pre-computed virtual points from the detector locations. A detection decision is made if a sufficient level of attraction, quantified by the increase in the clustering of the shifted virtual points, is observed. Compared with traditional methods, SRD has the following advantages: i) it does not require an accurate estimate of the source location from limited and noise-corrupted sensor readings, unlike the localizationbased methods, and ii) its virtual point shifting and clustering calculation involve simple arithmetic operations based on the number of detectors, avoiding the high computational complexity of grid-based likelihood estimation methods. We evaluate its detection performance using canonical datasets from Domestic Nuclear Detection Office s (DNDO) Intelligence Radiation Sensors Systems (IRSS) tests. SRD achieves both lower false alarm rate and false negative rate compared to three existing algorithms for network source detection.

Wu, Qishi↗

Seismic source functions from free-field ground motions recorded on SPE: Implications for source models of small, shallow explosions

In this, reduced displacement potentials (RDPs) for chemical explosions of the Source Physics Experiments (SPE) in granite at the Nevada Nuclear Security Site are estimated from free-field ground motion recordings. Far-field P wave source functions are proportional to the time derivative of RDPs. Frequency domain comparisons between measured source functions and model predictions show that high-frequency amplitudes roll off as ω -2 , but models fail to predict the observed seismic moment, corner frequency, and spectral overshoot. All three features are fit satisfactorily for the SPE-2 test after cavity radius R c is reduced by 12%, elastic radius is reduced by 58%, and peak-to-static pressure ratio on the elastic radius is increased by 100%, all with respect to the Mueller-Murphy model modified with the Denny-Johnson R c scaling law. A large discrepancy is found between the cavity volume inferred from RDPs and the volume estimated from laser scans of the emplacement hole. The measurements imply a scaled R c of ~5 m/kt 1/3 , more than a factor of 2 smaller than nuclear explosions. Less than 25% of the seismic moment can be attributed to cavity formation. A breakdown of the incompressibility assumption due to shear dilatancy of the source medium around the cavity is the likely explanation. New formulas are developed for volume changes due to medium bulking (or compaction). A 0.04% decrease of average density inside the elastic radius accounts for the missing volumetric moment. Assuming incompressibility, established R c scaling laws predicted the moment reasonable well, but it was only fortuitous because dilation of the source medium compensated for the small cavity volume.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Control system for the Spallation Neutron Source H{sup -} source test facility Allison scanner

Spallation Neutron Source is currently in progress of a multiyear plan to ramp ion beam power to the initial design power of 1.4 MW. Key to reaching this goal is understanding and improving the operation of the H{sup -} ion source. An Allison scanner was installed on the ion source in the test facility to support this improvement. This paper will discuss the hardware and the software control system of the installed Allison scanner. The hardware for the system consists of several parts. The heart of the system is the scanner head, complete with associated bias plates, slits, and signal detector. There are two analog controlled high voltage power supplies to bias the plates in the head, and a motor with associated controller to position the head in the beam. A multifunction data acquisition card reads the signals from the signal detector, as well as supplies the analog voltage control for the power supplies. To synchronize data acquisition with the source, the same timing signal that is used to trigger the source itself is used to trigger data acquisition. Finally, there is an industrial personal computer to control the rest of the hardware. Control software was developed using National Instruments LABVIEW, and consists of two parts: a data acquisition program to control the hardware and a stand alone application for offline user data analysis.

43 PARTICLE ACCELERATORS↗

Ramping up the Spallation Neutron Source beam power with the H{sup -} source using 0 mg Cs/day

This paper describes the ramp up of the beam power for the Spallation Neutron Source by ramping up the pulse length, the repetition rate, and the beam current emerging from the H{sup -} source. Starting out with low repetition rates ({<=}10 Hz) and short pulse lengths ({<=}0.2 ms), the H{sup -} source and low-energy beam transport delivered from Lawrence Berkeley National Laboratory exceeded the requirements with almost perfect availability. This paper discusses the modifications that were required to exceed 0.2 ms pulse length and 0.2% duty factor with acceptable availability and performance. Currently, the source is supporting neutron production at 1 MW with 38 mA linac beam current at 60 Hz and 0.9 ms pulse length. The pulse length will be increased to {approx}1.1 ms to meet the requirements for neutron production with a power between 1 and 1.4 MW. A medium-energy beam transport (MEBT) beam current of 46 mA with a 5.4% duty factor has been demonstrated for 32 h. A 56 mA MEBT beam current with a 4.1% duty factor has been demonstrated for 20 min at the conclusion of a 12-day production run. This is close to the 59 mA needed for 3 MW neutron productions. Also notable is the Cs{sub 2}CrO{sub 4} cesium system, which dispenses {approx}10 mg of Cs during the startup of the ion source, sufficient for producing the required 38 mA for 4 weeks without significant degradation.

43 PARTICLE ACCELERATORS↗

Plasma emission spectroscopy for operating and developing the Spallation Neutron Source (SNS) H{sup −} ion sources

A RF-driven, Cs-enhanced H{sup −} ion source feeds the SNS accelerator with a high current (typically >50 mA), ∼1.0 ms pulsed beam at 60 Hz. To achieve the persistent high current beam for several weeks long service cycles, each newly installed ion source undergoes a rigorous conditioning and cesiation processes. Plasma conditioning outgases the system and sputter-cleans the ion conversion surfaces. A cesiation process immediately following the plasma conditioning releases Cs to provide coverage on the ion conversion surfaces. The effectiveness of the ion source conditioning and cesiation is monitored with plasma emission spectroscopy using a high-sensitivity optical spectrometer. Plasma emission spectroscopy is also used to provide a means for diagnosing and confirming a failure of the insulating coating of the ion source RF antenna which is immersed in the plasma. Emissions of composition elements of the antenna coating material, Na emission being the most significant, drastically elevate to signal a failure when it happens. Plasma spectra of the developmental ion source with an AlN (aluminum nitrite) chamber and an external RF antenna are also briefly discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A NAIVE BAYES SOURCE CLASSIFIER FOR X-RAY SOURCES

The Chandra Carina Complex Project (CCCP) provides a sensitive X-ray survey of a nearby starburst region over >1 deg{sup 2} in extent. Thousands of faint X-ray sources are found, many concentrated into rich young stellar clusters. However, significant contamination from unrelated Galactic and extragalactic sources is present in the X-ray catalog. We describe the use of a naive Bayes classifier to assign membership probabilities to individual sources, based on source location, X-ray properties, and visual/infrared properties. For the particular membership decision rule adopted, 75% of CCCP sources are classified as members, 11% are classified as contaminants, and 14% remain unclassified. The resulting sample of stars likely to be Carina members is used in several other studies, which appear in this special issue devoted to the CCCP.

79 ASTRONOMY AND ASTROPHYSICS↗

Dark matter subhalos and unidentified sources in the Fermi 3FGL source catalog

If dark matter consists of weakly interacting massive particles (WIMPs), dark matter subhalos in the Milky Way could be detectable as gamma-ray point sources due to WIMP annihilation. In this work, we perform an updated study of the detectability of dark matter subhalos as gamma-ray sources with the Fermi Large Area Telescope (Fermi LAT). We use the results of the Via Lactea II simulation, scaled to the Planck 2015 cosmological parameters, to predict the local dark matter subhalo distribution. Under optimistic assumptions for the WIMP parameters—a 40 GeV particle annihilating to b b-bar with a thermal cross-section, as required to explain the Galactic center GeV excess—we predict that at most ∼ 10 subhalos might be present in the third Fermi LAT source catalog (3FGL). This is a smaller number than has been predicted by prior studies, and we discuss the origin of this difference. We also compare our predictions for the detectability of subhalos with the number of subhalo candidate sources in 3FGL, and derive upper limits on the WIMP annihilation cross-section as a function of the particle mass. If a dark matter interpretation could be excluded for all 3FGL sources, our constraints would be competitive with those found by indirect searches using other targets, such as known Milky Way satellite galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Automatic translation of MPI source into a latency-tolerant, data-driven form

Hiding communication behind useful computation is an important performance programming technique but remains an inscrutable programming exercise even for the expert. We present Bamboo, a code transformation framework that can realize communication overlap in applications written in MPI without the need to intrusively modify the source code. Bamboo reformulates MPI source into the form of a task dependency graph that expresses a partial ordering among tasks, enabling the program to execute in a data-driven fashion under the control of an external runtime system. Experimental results demonstrate that Bamboo significantly reduces communication delays while requiring only modest amounts of programmer annotation for a variety of applications and platforms, including those employing co-processors and accelerators. Moreover, Bamboo's performance meets or exceeds that of labor-intensive hand coding. The translator is more than a means of hiding communication costs automatically; it demonstrates the utility of semantic level optimization against a wellknown library.

Communication-computation↗

A low emittance and high efficiency visible light photocathode for high brightness accelerator-based X-ray light sources

Free-electron lasers and energy recovery linacs represent a new generation of ultra-high brightness electron accelerator based x-ray sources. Photocathodes are a critical performance-limiting component of these systems. Here, we describe the development of photocathodes based on potassium-cesium-antimonide that satisfy many of the key requirements of future light sources, such as robustness, high quantum efficiency when excited with visible light, and low transverse emittance.

43 PARTICLE ACCELERATORS↗

Inferring the source of evaporated waters using stable H and O isotopes

Stable isotope ratios of H and O are widely used to identify the source of water, e.g., in aquifers, river runoff, soils, plant xylem, and plant-based beverages. In situations where the sampled water is partially evaporated, its isotope values will have evolved along an evaporation line (EL) in δ 2 H/δ 18 O space, and back-correction along the EL to its intersection with a meteoric water line (MWL) has been used to estimate the source water’s isotope ratios. Here, we review the theory underlying isotopic estimation of source water for evaporated samples (iSW E ). We note potential for bias from a commonly used regression-based approach for EL slope estimation and suggest that a model-based approach may be preferable if assumptions of the regression approach are not valid. We then introduce a mathematical framework that eliminates the need to explicitly estimate the EL–MWL intersection, simplifying iSW E analysis and facilitating more rigorous uncertainty estimation. We apply this approach to data from the US EPA's 2007 National Lakes Assessment. We find that data for most lakes are consistent with a water source similar to annual runoff, estimated from monthly precipitation and evaporation within the lake basin. Strong evidence for both summer- and winter-biased sources exists, however, with winter bias pervasive in most snow-prone regions. Furthermore, the new analytical framework should improve the rigor of iSW E in ecohydrology and related sciences, and our initial results from US lakes suggest that previous interpretations of lakes as unbiased isotope integrators may only be valid in certain climate regimes.

54 ENVIRONMENTAL SCIENCES↗