At least 199 records · Page 11

An Update on Cardinal: Toward Full Core Pebble Simulations

The new DOE-NE Center of Excellence for Thermal-fluids applications in Nuclear Energy inaugurated in April 2018 considers and researches novel new solution strategies for historically challenging flow issues that still plague the current fleet of deployed Light Water nuclear Reactors (LWRs) as well as predicting various fluid flow and fluid related issues with advanced reactor technologies. Our advanced thermal-fluids research and development approach synergistically combines three natural, though overlapping, length and time scales in a hierarchal multi-scale approach to avoid the temptation and pitfalls of attempting to develop a single solve-all algorithm for physical fluid flow problems that will span nine orders of magnitude in spatial and temporal scales. To demonstrate the multi-scale philosophy of the center we focus on Fluoride Cooled High Temperature Reactors (FHRs), and in particular on the Berkley’s PB-FHR Mark-I design. The Fluoride salt cooled High temperature Reactor (FHR) is a class of advanced nuclear reactors that combine the robust coated particle fuel form from high temperature gas cooled reactors, direct reactor auxiliary cooling system (DRACS) passive decay removal of liquid metal fast reactors, and the transparent, high volumetric heat capacitance liquid Fluoride salt working fluids - such as Flibe - from molten salt reactors. This combination of fuel and coolant enables FHRs to operate in a high-temperature low-pressure design space that has beneficial safety and economic implications. The PB-FHR reactor relies on a pebble bed approach and pebble bed reactors are in a sense the poster child for multi-scale analysis. The lower length-scale simulator for pebble reactor cores comprises three physics: neutronics (OpenMC), thermal-fluids (Nek5000/NekRS) and fuel performance (BISON). As part of Center of Excellence ongoing research efforts we have developed Cardinal, a new tool platform for lower length-scale simulation. Cardinal tightly couples all three physics and leverages advances in MOOSE such as the MultiApp system and the concept of MOOSE-wrapped Apps. The present report provides an update on the development of Cardinal with an extension of Cardinal to GPUs. We also perform a first-of-a-kind demonstration simulation on Summit representing a 10x capability increase in terms of pebble count for Cardinal.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A strong fracture-resistant high-entropy alloy with nano-bridged honeycomb microstructure intrinsically toughened by 3D-printing

Strengthening materials via conventional “top-down” processes generally involves restricting dislocation movement by precipitation or grain refinement, which invariably restricts the movement of dislocations away from, or towards, a crack tip, thereby severely compromising their fracture resistance. In the present study, a high-entropy alloy Al0.5CrCoFeNi is produced by the laser powder-bed fusion process, a “bottom-up” additive manufacturing process similar to how nature builds structures, with the microstructure resembling a nano-bridged honeycomb structure consisting of a face-centered cubic (fcc) matrix and an interwoven hexagonal net of an ordered body-centered cubic B2 phase. While the B2 phase, combined with high-dislocation density and solid-solution strengthening, provides strength to the material, the nano-bridges of dislocations connecting the fcc cells, i.e., the channels between the B2 phase on the cell boundaries, provide highways for dislocation movement away from the crack tip. Consequently, the nature-inspired microstructure imparts the material with an excellent combination of strength and toughness.

36 MATERIALS SCIENCE↗

An Integrated Control Method for Supplemental Minisplit Heat Pumps in Existing Homes

The FSEC Energy Research Center(FSEC) at the University of Central Florida has investigated low-cost space-conditioning upgrade solutions for existing homes since 2014. The retrofits involve installing a modest capacity, centrally located, high efficiency, ductless, minisplit heat pump (MSHP) for use in conjunction with the home’s existing central space conditioning system (CSCS). This type of retrofit targets homes with older but not obsolete CSCSs that have not reached end of life, and presents a more cost-effective option to achieve space conditioning energy savings than outright CSCS replacement. This report describes results from investigating the energy savings potential, given adherence to comfort management, if the control of the MSHP and CSCS were integrated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CRADA Number NFE-22-09333 with Holocene Climate Corporation (CRADA Final Report:)

Holocene Climate Corporation has developed and scaled up a novel technology for Direct Air Capture (DAC) that is based on cutting-edge research initiated at Oak Ridge National Laboratory (ORNL). According to the IPCC, carbon dioxide capture from the air and its sequestration are necessary to keep global temperature rise below 1.5°C by 2050. DAC is a viable and practical way to reach this goal. DAC can happen anywhere in the world, takes up a fraction of the land of forests, and along with the sequestration of CO 2 , provides permanent and verifiable removal of carbon from the atmosphere. The proposed project aimed to facilitate knowledge transfer from ORNL to Holocene focusing on (i) the synthesis of the ORNL patented material which builds the cornerstone of the DAC technology, and (ii) required analytical methods needed to conduct crystallization bench-scale experimentation and technology development. Furthermore, ORNL conducted research centered around CO 2 absorption using an air-liquid contacting structure with an aqueous amino acid solution. The achievements under this project comprise successful knowledge transfer from ORNL to the entire Holocene team to jump-start their internal R&D and technological development activities.

54 ENVIRONMENTAL SCIENCES↗

Organizational and psychological measures for data center energy efficiency: barriers and mitigation strategies

Abstract It was last estimated that in 2020, data centers comprised approximately 2% of total US electricity consumption, with an estimated annual growth rate of 4%. As our country increasingly relies on information technology (IT), our data centers (DCs) will need to increase their energy efficiency (EE) to stabilize their energy consumption. The task of studying EE in DCs is complicated by the interconnected nature of humans and mission-critical technical systems. Moreover, the literature tends to focus on technology solutions such as improvements to IT equipment, cooling infrastructure, and software, without addressing organizational and psychological drivers. Our research demystifies the complex interactions between humans and DCs, by asking What non-technical barriers impede EE investment decision-making and/or implementing energy management strategies? To begin to answer this question, we perform a literature review of 86 resources, ranging from peer-reviewed journal publications to handbooks. We also consider related fields such as organizational behavioral management and energy intensive buildings. We develop a public Zotero library, perform content coding, and complete a rudimentary network analysis. Our findings from the literature review suggest that (1) technological solutions are abundant in the literature but fall short of providing practical guidance on the pitfalls of implementation, (2) making energy efficiency a priority at the executive level of organizations will be largely ineffective if the IT and facilities staff are not directly incentivized to increase EE, and (3) there is minimal current understanding of how the individual psychologies of IT and facilities staff affect EE implementation in DCs. In the next phase of our research, we plan to interview data center operators/experts to ground-truth our literature findings and collaboratively design decarbonization policy solutions that target organizational structure, empower individual staff, and foster a supportive external market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Providing Experimental Infrastructure for Accelerating Advanced Reactor Demonstrations through the National Reactor Innovation Center

A suite of experimental infrastructure projects has been developed by the National Reactor Innovation Center to accelerate advanced reactor demonstrations and facilitate their development, addressing crucial gaps in data, materials characterization, and modeling. First, the Molten Salt Thermophysical Examination Capability (MSTEC) provides a specialized platform for post-irradiation characterization of molten salt reactor fuel, coolant salts, and structural materials, essential for supporting the design and operation of advanced reactors and future commercial molten salt reactor development and licensing. The Virtual Test Bed (VTB) complements these efforts by leveraging advanced modeling and simulation tools to evaluate reactor performance and safety. Serving as a library of reference models, the VTB offers a database of multiphysics reactor models, facilitating rapid safety evaluations and includes continuous software quality assurance, crucial for accelerating deployment while maintaining reliability. Additionally, the Helium Component Test Facility (HeCTF) addresses the need for high-temperature helium-cooled reactor component testing. As the first-of-its-kind facility in the United States, HeCTF emulates high-temperature gas reactor conditions, reducing time and cost associated with component validation, thereby accelerating reactor development. Finally, In-cell Thermal Creep Frames provide a unique solution for obtaining thermal creep data from irradiated materials, critical for materials qualification and licensing. Developed by the National Reactor Innovation Center, these compact frames enable the examination of previously irradiated materials, overcoming traditional limitations and enhancing the understanding of mechanical properties crucial for reactor development. Collectively, these experimental infrastructure projects form a comprehensive framework aimed at expediting advanced reactor demonstrations, fostering innovation, and ensuring the viability of next-generation nuclear energy solutions.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Rapidly Viable Sustained Grid

Rapid recovery of power flow, possibly after a blackout, is a crucial need arising in scenarios that are increasingly becoming more frequent; here, solutions for rapid viability of power while the grid is being restored are urgently needed to keep critical infrastructure (CI) online. Increasingly, after the initial recovery phase, sustenance of reliable power requires assistive services to the grid for long periods of time. Even though the need is urgent, there is only sparse effort present toward a comprehensive framework/strategy for making power rapidly viable with an emphasis on sustained grid ancillary services; which is the focus of this proposal. The proposed concept envisions four phases. In the first phase, when a large portion of power is disrupted (see Figure 1(a)), emphasis is on bringing CI online with the objective of maximizing the time horizon of power viability using resources available at the CI. In the second phase (Figure 1(b)), neighborhood resources are tightly coordinated that forms the CI’s central-core (CC) to provide guaranteed viability of CI over a longer horizon. In the third phase, self-organizing power networks are expanded in a distributed layer supporting the central-core (Figure 1(c)). In the fourth phase, separate CI-networks coalesce and are controlled in a coordinated fashion to provide grid ancillary services (AS), such as primary frequency control and enhancing grid resiliency. With time, system efficiencies and penetration of renewables increase, while the time-horizon of guaranteed sustenance of CI is maximized. Under proposed work, the concept will be instantiated with a focus on medical centers as CI. Comprehensive power hardware in the loop strategies and emulated field tests will guide and validate devised solutions. A strong T2M effort to commercialize resulting technology is outlined. The proposed technology will be transformative for the grid. It will fundamentally change the way large contingencies are managed where power systems and critical infrastructure transition from being fragile to being robust using intelligent, self-organizing control for coordinating resources, enhanced resiliency and use of sustainable energy sources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Shedding light on U.S. small and midsize data centers: Exploring insights from the CBECS survey

As demand for digital services accelerates, the energy and environmental footprint of data centers faces increasing scrutiny. While hyperscale cloud facilities have driven efficiency gains, small and midsize U.S. data centers remain a critical yet underexamined segment with significant untapped potential for energy savings. This study leverages data from the Commercial Buildings Energy Consumption Survey (CBECS) to analyze trends in server stocks, computing customers, cooling system adoption and efficiency, and geospatial distribution from 2012 to 2018. Findings reveal a sharp decline in small and midsize data centers, from 1.764 million to 1.398 million, with server counts dropping from 5.177 million to 4.262 million—aligning with the broader shift toward cloud computing. More than 40 % of servers in small data centers and 55 % in midsize data centers are housed in office buildings, and over half of all servers are concentrated in climate zones 5A (cold), 3A (mixed-humid), and 4A (mixed-humid), with the highest densities in metropolitan hubs. While direct expansion units remain the dominant cooling system, a clear transition toward more energy-efficient solutions, particularly air economizers, is evident. By integrating server and cooling system distributions, we estimate Power Usage Effectiveness (PUE) and Water Usage Effectiveness (WUE) for U.S. data centers by size and year. Results show that midsize data centers are more energy-efficient but more water-intensive due to the widespread use of water-cooled chillers. These findings highlight the trade-offs in cooling system selection and provide a critical foundation for policies aimed at enhancing efficiency in an evolving data center landscape.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Butyltin Keggin Ion with a Rare Four-Coordinate Ca Center

Alkyltin clusters are exploited in nanolithography for the fabrication of microelectronics. The alkyltin Keggin family is unique among Keggin clusters across the periodic table; its members appear to favor the lower-symmetry β and γ isomers rather than the highly symmetrical α and ε isomers. Therefore, the alkyltin Keggin family may provide important fundamental information about the formation and isomerization of Keggin clusters. In this study, we have synthesized and structurally characterized a new butyltin Keggin cluster with a tetrahedral Ca 2+ center, fully formulated [(BuSn) 12 (CaO 4 )(OCH 3 ) 12 (O) 4 (OH) 8 ] 2+ (β-CaSn 12 ). The synthesis is a simple one-step process. Extensive solution characterization including electrospray ionization mass spectrometry, small-angle X-ray scattering, and multinuclear ( 1 H, 13 C, and 119 Sn) nuclear magnetic resonance shows β-CaSn 12 is essentially phase-pure and stable. This differs from the previously reported Na-centered analogues that always form a mixture of β and γ isomers, with facile interconversion. Therefore, this study has clarified prior confusion over complex spectroscopic and crystallographic characterization of the Na-centered analogues. Density functional theory calculations showed the following stability order: γ-CaSn 12 < γ-NaSn 12 < β-CaSn 12 < β-NaSn 12 . The β analogue is always more stable than the γ analogue, consistent with experiment. Notable outcomes of this study include a rare tetrahedral Ca coordination, a Na-free alkyltin cluster (important for microelectronics manufacturing), and a better understanding of Keggin families built of different metal cations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating the evidence for exponential quantum advantage in ground-state quantum chemistry

Due to intense interest in the potential applications of quantum computing, it is critical to understand the basis for potential exponential quantum advantage in quantum chemistry. Here we gather the evidence for this case in the most common task in quantum chemistry, namely, ground-state energy estimation, for generic chemical problems where heuristic quantum state preparation might be assumed to be efficient. The availability of exponential quantum advantage then centers on whether features of the physical problem that enable efficient heuristic quantum state preparation also enable efficient solution by classical heuristics. Through numerical studies of quantum state preparation and empirical complexity analysis (including the error scaling) of classical heuristics, in both ab initio and model Hamiltonian settings, we conclude that evidence for such an exponential advantage across chemical space has yet to be found. While quantum computers may still prove useful for ground-state quantum chemistry through polynomial speedups, it may be prudent to assume exponential speedups are not generically available for this problem.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Designing FAIR Workflows at OLCF: Building Scalable and Reusable Ecosystems for HPC Science

High Performance Computing (HPC) centers, such as the Oak Ridge Leadership Computing Facility (OLCF), provide advanced infrastructure that enables scientific research at extreme scale. These centers operate with unique hardware configurations, specialized software environments, and elevated security re quirements that differ substantially from what most users encounter on their local systems. As a result, users often develop customized digital artifacts that are tightly coupled to the specific configuration of a given HPC center. Although necessary, this practice can lead to significant duplication of effort as multiple users independently create similar solutions to common problems.

97 MATHEMATICS AND COMPUTING↗

ORNL Package Testing Program Overview

When transporting radioactive or hazardous materials, safety and security are top priorities. Packaging and transportation regulations require reliable evidence that containers have passed rigorous performance tests to ensure that the public and the environment are protected from the hazardous nature of the cargo. Because of its long history in energy and security research, Oak Ridge National Laboratory (ORNL) has needed to ship hazardous packages for the past 65 years. Since the 1940s, ORNL has made significant contributions to transportation regulations and has been at the forefront of regulatory testing development. Today, ORNL is a leader in standards development and testing of designs of radioactive material packages. ORNL plays a critical role in ensuring the safe transportation of radioactive materials across the United States by executing rigorous testing campaigns of packages that contain radioactive materials. Early testing activities focused on supporting the development of transportation regulations established by both the International Atomic Energy Agency (IAEA) and the United States. Currently, all package testing activities are performed under the Package Testing Program (PTP) at the Package Evaluation Facility (PEF) located at the National Transportation Research Center (NTRC), which is about 10 miles from the main ORNL campus. The PTP develops and evaluates testing solutions, ensuring that they are safe efficient, and in compliance with regulatory requirements. The vision for the PTP is to be a world-class leader in the evaluation and testing of radioactive and hazardous material packages. The key elements necessary to fulfill this mission are an experienced and professional staff; state-of-the-art facilities, equipment, and instrumentation; and completion of challenging programs and projects important to package transportation. Collaborations with other internal and external organizations play a significant role in building stronger teams and achieving this vision. By adhering to and advancing regulatory standards, ORNL’s PTP supports development of safe and compliant packaging, safeguarding the transportation process from potential risks associated with radioactive material logistics.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Global Geo-processed Data of Aquifer Properties by 0.5° Grid, Country and Water Basins

This repository of global hydrogeologic datasets contains aquifer properties on 0.5° scale, including depth to groundwater (Fan et al., 2013), aquifer thickness (de Graaf et al., 2015), WHYMap aquifer classes (Richts et al., 2011), recharge (Döll and Fiedler, 2008; Gleeson et al., 2016), lakes (Messager et al., 2016), porosity and permeability (Gleeson et al., 2014), digitized and geo-processed from their respective sources. Globally gridded aquifer properties could be used independently to estimate global groundwater availability or used as critical inputs to the superwell model to simulate groundwater extraction and provide estimates of pumped volumes and unit costs under user-specific scenarios. Key resources related to this data are: Niazi, H., Ferencz, S. B., Graham, N. T., Yoon, J., Wild, T. B., Hejazi, M., Watson, D. J., & Vernon, C. R. (2025). Long-term hydro-economic analysis tool for evaluating global groundwater cost and supply: Superwell v1.1. Geoscientific Model Development, 18(5), 1737-1767. https://doi.org/10.5194/gmd-18-1737-2025 superwell model repository which uses this data to simulate groundwater extraction and provides estimates of the global extractable volumes and unit-costs ($/km3) of accessible groundwater production under user-specified extraction scenarios. Repository Overview Main output: aquifer_properties_rec.csv contains all processed outputs, including aquifer properties like porosity, permeability, recharge, lake areas, aquifer thickness, and depth to groundwater. shapefiles.zip: contains all digitized GIS databases and shapefile for all aquifer properties prep_inputs.R and prep_inputs_recharge_lakes.R: R scripts that process the shapefiles to produce the aquifer_properties_rec.csv file plot_inputs.R: R script for plotting the maps and conducting preliminary analysis on the available groundwater volume basin_to_country_mapping.csv, basin_country_region_mapping.csv and continent_county_mapping.csv provide the mapping between continents, 32 energy-economic macro regions, countries, and water basins for post-processing aquifer_properties_rec.csv Maps: Each map visualizes the spatial distribution of one of the aquifer properties across the globe map_in_Porosity.png map_in_Permeability.png map_in_Aquifer_thickness.png map_in_Depth_to_water.png map_in_Recharge.png map_in_Grid_area_km.png map_in_Lake_area_km.png map_in_WHYClass.png Sample inputs sample_inputs.py: this script samples inputs from the aquifer_properties_rec dataset, ensuring the sampled and original inputs maintain the same distributions sampled_data_100.csv contains 100 sampled data points and sampled_data_100.png compares their distributions Dataset Overview The main outputs are consolidated in a comprehensive aquifer_properties_rec.csv file and include the following fields: GridCellID: Unique identifier for each (roughly 0.5°) grid cell Continent: Continent name Country: Country name GCAM_basin_ID: Identifier for GCAM hydrologic basin Basin_long_name: Full name of the basin WHYClass: Hydrogeologic classification based on WHYMap aquifer classes (Richts et al., 2011) Porosity: Soil porosity (%) (Gleeson et al., 2014) Permeability: Soil permeability (in square meters; Gleeson et al., 2014) Aquifer_thickness: Thickness of the aquifer (in meters; de Graaf et al., 2015) Depth_to_water: Depth to groundwater (in meters; Fan et al., 2013) Recharge: long-term annual averaged recharge rates (in m/yr; Döll and Fiedler, 2008; Gleeson et al., 2016) Grid_area: Area of the grid cell (in square meters) Lakes_area: Area of inland lakes (in square meters; Messager et al., 2016) Key References The datasets are digitized versions of global hydrogeologic properties from the following key literature sources: Depth to Groundwater: Fan, Y., Li, H., & Miguez-Macho, G. (2013). Global Patterns of Groundwater Table Depth. Science, 339(6122), 940-943. https://doi.org/10.1126/science.1229881 Aquifer Thickness: de Graaf, I. E. M., Sutanudjaja, E. H., van Beek, L. P. H., & Bierkens, M. F. P. (2015). A high-resolution global-scale groundwater model. Hydrol. Earth Syst. Sci., 19(2), 823-837. https://doi.org/10.5194/hess-19-823-2015 Porosity and Permeability: Gleeson, T., Moosdorf, N., Hartmann, J., & van Beek, L. P. H. (2014). A glimpse beneath earth's surface: GLobal HYdrogeology MaPS (GLHYMPS) of permeability and porosity. Geophysical Research Letters, 41(11), 3891-3898. https://doi.org/10.1002/2014GL059856 Aquifer classes: Richts, A., Struckmeier, W. F., & Zaepke, M. (2011). WHYMAP and the Groundwater Resources Map of the World 1:25,000,000. In J. A. A. Jones (Ed.), Sustaining Groundwater Resources: A Critical Element in the Global Water Crisis (pp. 159-173). Springer Netherlands. https://doi.org/10.1007/978-90-481-3426-7_10 Recharge: Döll, P., & Fiedler, K. (2008). Global-scale modeling of groundwater recharge. Hydrol. Earth Syst. Sci., 12(3), 863-885. https://doi.org/10.5194/hess-12-863-2008; Gleeson, T., Befus, K. M., Jasechko, S., Luijendijk, E., & Cardenas, M. B. (2016). The global volume and distribution of modern groundwater. Nature Geoscience, 9(2), 161-167. https://doi.org/10.1038/ngeo2590 Inland Lakes: Messager, M. L., Lehner, B., Grill, G., Nedeva, I., & Schmitt, O. (2016). Estimating the volume and age of water stored in global lakes using a geo-statistical approach. Nature Communications, 7(1), 13603. https://doi.org/10.1038/ncomms13603 Cite as Niazi, H., Watson, D., Hejazi, M., Yonkofski, C., Ferencz, S., Vernon, C., Graham, N., Wild, T., & Yoon, J. (2024). Global Geo-processed Data of Aquifer Properties by 0.5° Grid, Country and Water Basins. MultiSector Dynamics-Living, Intuitive, Value-adding, Environment. https://doi.org/10.57931/2484226 Contact Reach out to Hassan Niazi or open an issue in the superwell repository for questions or suggestions.

aquifer thickness↗

Tackling the Giants: Applying Smart Labs Principles to Constant Air Volume Lab Buildings

Laboratories typically consume 3 to 10 times more energy than similarly sized commercial buildings, and as much as 50% of that energy is wasted by inefficient and poorly operating fume hoods and ventilation systems. One challenge faced by older laboratory buildings is the heating, ventilation, and air-conditioning systems serving many of these buildings. The older systems are usually constant air volume (CAV) systems that maintain constant ventilation rates that cause excess airflow and inefficient energy use. Variable air volume systems can be more efficient systems with sensors to detect the need for a change in volumetric flow rate; however; renovation of ventilation systems can create disruption to ongoing research and operations along with considerable up-front costs. When a Smart Labs program is implemented, an organization has a systems-based management approach that yields a high-performing laboratory building. As decarbonization continues as a priority for sites, buildings with CAV systems are difficult to address. This work centers around practical guidance for improving lab buildings with CAV. In conjunction with industry input on top technology solutions and best practices, recommendations will include performing a laboratory ventilation risk assessment in conjunction with robust retro-commissioning work, which is a crucial step in the Smart Lab process. By applying Smart Labs principles, the aging laboratory building stock of 153,343 (Lawrence Berkeley National Laboratory [LBNL] 2017), comprising roughly 500,000 lab spaces in the United States, can be brought to safe and high-performance operations.

building↗

PolyODENet

Kinetics of a reaction network that follows mass-action rate laws can be described with a system of ordinary differential equations (ODEs) with polynomial right-hand side. However, it is challenging to derive such kinetic differential equations from transient kinetic data without knowing the reaction network, especially when the data are incomplete due to experimental limitations. We introduce a program, PolyODENet, toward this goal. Based on the machine-learning method Neural ODE, PolyODENet defines a generative model and predicts concentrations at arbitrary time. As such, it is possible to include unmeasurable intermediate species in the kinetic equations. Importantly, we have implemented various measures to apply physical constraints and chemical knowledge in the training to regularize the solution space.

Wu, Qin [Brookhaven National Lab. (BNL), Upton, NY↗

Recent Collaborations and Innovations to Demonstrate Next-Generation Techniques for Monitoring Subsurface Carbon Storage

World Carbon Capture, Utilization, and Storage (CCUS) Conference, Bergen, Norway, September 1–4, 2025. This talk provides a high-level overview of many novel and sustainable carbon storage-monitoring methods to accelerate the deployment of CCUS technologies at future CCUS sites across the United States. The Energy & Environmental Research Center’s work impacts the general CCUS industry by providing novel low-impact methods for tracking the injected plume’s migration and more autonomous data collection and processing techniques for performing assurance monitoring. Specifically, the results benefit 1) CCUS community members through knowledge sharing of lessons learned; 2) CCUS operators through commercialization of additional methods, including improvements to workflows and simplification of fieldwork; and 3) CCUS project stakeholders through implementation of low-impact and more autonomous monitoring solutions.

02 PETROLEUM↗

ORNL_AISD_NiPt_108atoms

This dataset describes the nickel-platinum (NiPt) solid solution binary alloy, where the two constituent elements nickel (Ni) and platinum (Pt) are randomly placed on the face centered cubic (FCC) crystal structure, with the lattice constant of 3.840 angstroms. The dataset comprises data for crystal structures with 108 atoms with 1,900 configurations. The data set was generated for concentrations ranging from 0at% of Pt to 100at% of Pt in the NiPt binary system, with increasing the concentration of Pt in the system every 5at%. For each one of the chemical compositions, 100 random configurations were generated, each with a different random seed. Each of the output files contains the mass, type, atomic coordinates, energy per atom, and forces in x, y, and z directions respectively. For each atomic configuration, the output was collected every 150 steps during the minimization stage and every 1000 steps during the replica exchange stage. Large-scale Atomic/Molecular Massively Parallel Simulator (LAMMPS) [1], which is a molecular dynamics code, was used to generate data for NiPt alloy. The simulation used the interatomic potential for NiPt binary system 'MEAM_LAMMPS_KimSeolJi_2017_PtNi__MO_020840179467_001' [3] from the OpenKIM library (Open Knowledgebase of Interatomic Models) [2]. This potential was developed based on the second nearest-neighbor modified embedded-atom method (2NN MEAM). The simulation process begins with the generation of the random NiPt structure and follows with the short minimization and replica exchange simulation. The minimization procedure adjusts atomic coordinates and performs energy minimization, which typically leads to a local potential energy minimum. The method used for the minimization was the conjugate gradient algorithm. A short replica exchange (parallel tempering) simulation involves four replicas (ensembles) of a system and follows the minimization stage. Multiple snapshots of the configuration were collected during the minimization and replica exchange stages. NiPt alloy is interesting due to its magnetic and charge transfer properties [4]. The data is provided in a compressed zipped folders atoms108.zip. The zipped folder contains the data structured in the following way: - Ni_ground_state.cfg --> atomic configuration for the pure nickel - Pt_ground_state.cfg --> atomic configuration for the pure platinum - Pt#_filtered --> folders containing atomic configurations for #at% concentration of platinum. The folder contains 100 atomic configurations, each saved in a subfolder - Each subfolder named config* is associated with a specific atomic configuration. Each of these subfolders contains files with .cfg format, corresponding to outputs for each atomic configuration The total number of atomic configurations contained in atoms108.zip is 66,132. This dataset is an extension to the dataset ORNL_AISD_NiPt [5] that has been previously released with crystal structures of 256 atoms, 864 atoms, and 2,048 atoms, with the same methodology for data collection. References [1] https://www.lammps.org/ [2] https://openkim.org/ [3] https://openkim.org/id/MEAM_LAMMPS_KimSeolJi_2017_PtNi__MO_020840179467_001 [4] El-Gendy, Ahmed A. and Hampel, Silke and Büchner, Bernd and Klingeler, Rüdiger, Tuneable magnetic properties of carbon-shielded NiPt-nanoalloys, RSC Adv., volume 6, issue 57, pages 52427-52433, 2016, The Royal Society of Chemistry, doi:10.1039/C6RA05910D [5] M. Karabin, M. Lupo Pasini, and M. Eisenbach. ORNL_AISD_NiPt. United States: N. p., 2023. Web. doi:10.13139/OLCF/1958172.

36 MATERIALS SCIENCE↗