Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “single photon emission”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Giant nonlinear optical responses from photon-avalanching nanoparticles

Avalanche phenomena use steeply nonlinear dynamics to generate disproportionately large responses from small perturbations, and are found in a multitude of events and materials. Photon avalanching enables technologies such as optical phase-conjugate imaging, infrared quantum counting and efficient upconverted lasing. However, the photon-avalanching mechanism underlying these optical applications has been observed only in bulk materials and aggregates, limiting its utility and impact. In this study we report the realization of photon avalanching at room temperature in single nanostructures-small, Tm 3+ -doped upconverting nanocrystals-and demonstrate their use in super-resolution imaging in near-infrared spectral windows of maximal biological transparency. Avalanching nanoparticles (ANPs) can be pumped by continuous-wave lasers, and exhibit all of the defining features of photon avalanching, including clear excitation-power thresholds, exceptionally long rise time at threshold, and a dominant excited-state absorption that is more than 10,000 times larger than ground-state absorption. Beyond the avalanching threshold, ANP emission scales nonlinearly with the 26th power of the pump intensity, owing to induced positive optical feedback in each nanocrystal. This enables the experimental realization of photon-avalanche single-beam super-resolution imaging with sub-70-nanometre spatial resolution, achieved by using only simple scanning confocal microscopy and without any computational analysis. Pairing their steep nonlinearity with existing super-resolution techniques and computational methods, ANPs enable imaging with higher resolution and at excitation intensities about 100 times lower than other probes. The low photon-avalanching threshold and excellent photostability of ANPs also suggest their utility in a diverse array of applications, including sub-wavelength imaging and optical and environmental sensing.

36 MATERIALS SCIENCE↗

Using quantum noise correlation analysis to measure ion temperature

Quantum noise correlation analysis was tested at the proof-of-concept level as a technique to measure ion temperature in a plasma. If eventually successful, this technique could enable a compact, inexpensive, and robust ion temperature diagnostic suitable for a burning plasma environment. Ion temperature is a key parameter determining the fusion performance of a burning plasma, as the fusion cross-section has a strong dependence on ion temperature. This ion temperature diagnostic would require only a small optical view of the plasma through a port to passively record impurity line emission. The instrumentation would be remote from the reactor behind the neutron and bio-shielding. The technique relies solely on quantum correlations of the photons emitted by a plasma impurity to measure ion temperature; there is no grating dispersion of an emission line-width or pulse-height analysis of photon energy. This measurement innovation was tested with instrumentation consisting of two single-photon detectors with high timing resolution, a time-tagging unit, and simple light collection optics. This instrumentation measures the second-order correlation between the light intensity falling on the two detectors. The next steps beyond the proof-of-concept level will be development of diagnostic designs for application of this technique to high-temperature and burning plasmas. Arrays of single-photon avalanche detectors to multiplex measurements of photon correlation will be required to reduce signal integration time to an acceptable duration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An XMM-Newton Study of 9SGR and the Lagoon Nebula

We report preliminary results of an XMM-Newton observation of the 04 V star 9 Sgr (= HD 164794). 9 Sgr is one of a few single OB stars that display a non-thermal radio emission attributed to synchrotron emission by relativistic electrons. Inverse Compton scattering of photospheric UV photons by these relativistic electrons is a priori expected to generate a non-thermal power-law tail in the X-ray spectrum. Our EPIC and RGS spectra of 9 Sgr suggest a more complex situation than expected from this 'simple' theoretical picture. Furthermore, soft-band EPIC images of the region around 9 Sgr reveal a number of point sources inside the Lagoon Nebula (M8). Most of these sources have optical counterparts inside the very young open cluster NGC 6530 and several X-ray sources are associated with low and intermediate mass pre-main sequence stars. Finally, we also detect (probably) diffuse X-ray emission from the Hourglass Region that might reveal a hot bubble blown by the stellar wind of Herschel 36, the ionizing star of the HG region.

Rauw, G.↗

Creation of Single-Photon Emitters in WSe 2 Monolayers Using Nanometer-Sized Gold Tips

Due to their tunable bandgaps and strong spin-valley locking, transition metal dichalcogenides constitute a unique platform for hosting single-photon emitters. Here, we present a versatile approach for creating bright single-photon emitters in WSe 2 monolayers by the deposition of gold nanostars. Our molecular dynamics simulations reveal that the formation of the quantum emitters is likely caused by the highly localized strain fields created by the sharp tips of the gold nanostars. The surface plasmon modes supported by the gold nanostars can change the local electromagnetic fields in the vicinity of the quantum emitters, leading to their enhanced emission intensities. Moreover, by correlating the emission energies and intensities of the quantum emitters, we are able to associate them with two types of strain fields and derive the existence of a low-lying dark state in their electronic structures. The findings here are highly relevant for the development and understanding of single-photon emitters in transition metal dichalcogenide materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The High-Energy Continuum Emission of the Gamma-Ray Blazar PKS 0528+134

We present Advanced Satellite for Cosmology and Astrophysics (ASCA) observations of the gamma-ray blazar PKS 0528 + 134, obtained at two separate epochs in 1994 August and 1995 March. These data represent the first measurement of the X-ray continuum emission of this source in the medium-hard X-ray band. Both ASCA spectra are consistent with a single power law with photon index GAMMA approximate 1.7-1.8 and column density N(sub H) approximately 5 x 10(exp 21) /sq cm, higher than Galactic. The X-ray flux increased by a factor of 4 in approximately 7 months without appreciable change of the spectral shape. During the lower state of 1994 August, PKS 0528 + 134 was observed simultaneously in the optical, X-rays, and at gamma-ray energies with EGRET. The gamma-ray intensity is the faintest detected thus far in the source, with a steep spectrum (GAMMA approximately 2.7). The extrapolation of the X-ray continuum to the gamma-ray range requires a sharp spectral break at approximately 10(exp 22) Hz. We discuss the radio through gamma-ray spectral energy distribution of PKS 0528 + 134, comparing the low state of 1994 August with the flare state of 1993 March. We show that in PKS 0528 + 134, a non-negligible contribution from the external radiation field is present and that, although synchrotron self-Compton scenarios cannot be ruled out, inverse Compton upscattering of thermal seed photons may be the dominant cooling process for the production of the high-energy continuum in this blazar.

Sambruna, Rita M.↗

The High-energy Continuum Emission of the Gamma-Ray Blazar PKS 0528+134

We present Advanced Satellite for Cosmology and Astrophysics (ASCA) observations of the gamma-ray blazar PKS 0528 + 134, obtained at two separate epochs in 1994 August and 1995 March. These data represent the first measurement of the X-ray continuum emission of this source in the medium-hard X-ray band. Both ASCA spectra are consistent with a single power law with photon index GAMMA approx. = 1.7-1.8 and column density N(sub H) approx. = 5 x 10(exp 21)/ sq cm, higher than Galactic. The X-ray flux increased by a factor of 4 in approx. 7 months without appreciable change of the spectral shape. During the lower state of 1994 August, PKS 0528 + 134 was observed simultaneously in the optical, X-rays, and at gamma-ray energies with Energetic Gamma Ray Experiment Telescope (EGRET). The gamma-ray intensity is the faintest detected thus far in the source, with a steep spectrum (GAMMA approx. = 2.7). The extrapolation of the X-ray continuum to the gamma-ray range requires a sharp spectral break at approx. 10(exp 22) Hz. We discuss the radio through gamma-ray spectral energy distribution of PKS 0528 + 134, comparing the low state of 1994 August with the flare state of 1993 March. We show that in PKS 0528 + 134, a non-negligible contribution from the external radiation field is present and that, although synchrotron self-Compton scenarios cannot be ruled out, inverse Compton upscattering of thermal seed photons may be the dominant cooling process for the production of the high-energy continuum in this blazar.

Sambruna, Rita M.↗

Ultranarrow electroluminescence from magnetic excitons in the van der Waals antiferromagnetic semiconductor NiPS 3

Electrically driven light emission from two-dimensional (2D) semiconducting materials has enabled numerous optoelectronic technologies, including light-emitting diodes, solid-state lasers, and single-photon sources for quantum communication. Here we report ultranarrow electroluminescence from the magnetic excitonic state of the van der Waals antiferromagnetic semiconductor NiPS 3 . This electroluminescence is enabled by the fabrication of gate-tunable NiPS 3 devices that remain electrically conductive below the antiferromagnetic ordering temperature of 155 K, ultimately allowing field-effect mobilities of 1.3 cm 2 V –1 s –1 and 4.5 cm 2 V –1 s –1 to be directly measured at room temperature and 7 K, respectively. By applying a high-frequency square wave voltage to the gate electrode of the resulting field-effect transistors, electroluminescence is capacitively induced from the magnetic excitons of NiPS 3 . Due to the coupling of these excitons with the underlying NiPS 3 antiferromagnetic order, the electroluminescence has an ultranarrow linewidth of 1 meV and a high degree of linear polarization (ρ = 0.78). In addition to facilitating fundamental studies of the coupling between spin states and excitons in van der Waals magnetic semiconductors, this work will accelerate the development of emerging 2D opto-spintronic applications.

two-dimensional materials↗

Coupling of a single tin-vacancy center to a photonic crystal cavity in diamond

In this work, we demonstrate optical coupling between a single tin-vacancy (SnV) center in diamond and a free-standing photonic crystal nanobeam cavity. The cavities are fabricated using quasi-isotropic etching and feature experimentally measured quality factors as high as ~11000. We investigate the dependence of a single SnV center's emission by controlling the cavity wavelength using a laser-induced gas desorption technique. Under resonance conditions, we observe an intensity enhancement of the SnV emission by a factor of 12 and a 16-fold reduction of the SnV lifetime. Based on the large enhancement of the SnV emission rate inside the cavity, we estimate the Purcell factor for the SnV zero-phonon line to be 37 and the coupling efficiency of the SnV center to the cavity, the β factor, to be 95%. Our work paves the way for the realization of quantum photonic devices and systems based on efficient photonic interfaces using the SnV color center in diamond.

42 ENGINEERING↗

A new near-infrared imaging study of AFGL 2688

The object AFGL 2688 is a bipolar nebula surrounding a post-asymptotic giant branch star and is in transition toward becoming a planetary nebula. We present new NIR images in the I, J, H, and K bandpasses. These images reveal a wealth of structure in the nebula not previously seen. We find that the northern lobe is not smooth, but clumpy. There is evidence in the I-band image for periodic variations in mass-loss rate. In addition, we present narrowband images centered on the V = 1 - 0 S(1) line of molecular hydrogen and nearby continuum. The narrowband images reveal that broadband flux found in the equatorial region is dominated by line emission from vibrationally excited molecular hydrogen. H2 emission is also present in the lobes. Our K-band images show the equatorial emission to be in the form of a ring or torus extending around the object at a distance R about 7 x 10 exp 16 (D/1 kpc) cm. Mechanisms for exciting the equatorial H2 emission are discussed; we conclude that shocks are the only plausible source. We have analyzed the broadband images using models which assume single scattering of photons from the central star. We find that the bipolar axis is inclined to the plane of the sky by i about 5 deg. The images are best reproduced by models in which the density of scattering dust decreases fairly rapidly with increasing stellar latitude, with little or no dust near the poles. Furthermore, the optical depth is found to have very little wavelength dependence, which implies that the dust in AFGL 2688 is different from that in the interstellar medium.

Latter, William B.↗

A Test of Thick-Target Nonuniform Ionization as an Explanation for Breaks in Solar Flare Hard X-Ray Spectra

Solar nonthermal hard X-ray (HXR) flare spectra often cannot be fitted by a single power law, but rather require a downward break in the photon spectrum. A possible explanation for this spectral break is nonuniform ionization in the emission region. We have developed a computer code to calculate the photon spectrum from electrons with a power-law distribution injected into a thick-target in which the ionization decreases linearly from 100% to zero. We use the bremsstrahlung cross-section from Haug (1997), which closely approximates the full relativistic Bethe-Heitler cross-section, and compare photon spectra computed from this model with those obtained by Kontar, Brown and McArthur (2002), who used a step-function ionization model and the Kramers approximation to the cross-section. We find that for HXR spectra from a target with nonuniform ionization, the difference (Delta-gamma) between the power-law indexes above and below the break has an upper limit between approx.0.2 and 0.7 that depends on the power-law index delta of the injected electron distribution. A broken power-law spectrum with a. higher value of Delta-gamma cannot result from nonuniform ionization alone. The model is applied to spectra obtained around the peak times of 20 flares observed by the Ramaty High Energy Solar Spectroscopic Imager (RHESSI from 2002 to 2004 to determine whether thick-target nonuniform ionization can explain the measured spectral breaks. A Monte Carlo method is used to determine the uncertainties of the best-fit parameters, especially on Delta-gamma. We find that 15 of the 20 flare spectra require a downward spectral break and that at least 6 of these could not be explained by nonuniform ionization alone because they had values of Delta-gamma with less than a 2.5% probability of being consistent with the computed upper limits from the model. The remaining 9 flare spectra, based on this criterion, are consistent with the nonuniform ionization model.

Holman, gordon↗

Sub-10 nm upconversion nanocrystals for long-term single-particle tracking

Lanthanide-doped upconversion nanoparticles are attractive single-molecule imaging probes due to their high photostability and anti-Stokes luminescence. However, achieving both small particle size and strong brightness has remained a major challenge, as reducing size often leads to dimmer emission. Herein, we fabricate a sub-10 nm cascade actively protected upconversion nanoparticles, which shows a 33-fold enhanced upconversion efficiency at the single-particle level compared to larger ~19 nm conventional nanoparticles. Theoretical modeling and time-resolved measurements show that emission loss mainly comes from energy leakage of Er 3+ ions to surface defects. By introducing a NaYbF 4 layer as photon-harvesting and protective intermediate layer, we minimize this energy loss and significantly boost brightness. A monolayer of inert NaLuF 4 can effectively suppress the surface quenching to Yb 3+ . Using these ultra-small bright probes, we successfully tracked single epidermal growth factor receptor molecules on live cells for up to one hour, revealing dynamic switching between different diffusion modes.

Qiu, Xiaochen [Fudan Univ., Shanghai (China); Shen↗

Theoretical Study of the Single Electron Optical Stochastic Cooling Experiment at the IOTA Facility (Final Technical Report)

The objectives of this proposal were to explore fundamental aspects of radiation from individual and small groups of electrons in the optical stochastic cooling experiment conducted at Fermi National Laboratory's IOTA facility. Professor Swapan Chattopadhyay collaborated directly with the IOTA team on their initial experimental endeavors. Concurrently, a team from Berkeley, including Prof. Wurtele, Dr. Charman, and Dr. Greggory Penn from LBNL, and Prof. Chattapadhyay, pursued a theoretical exploration to identify potential subsequent experiments for IOTA. A wide range of possible experiments were considered, but they do not allow for tests for new quantum mechanical phenomena at the precision level of the current IOTA apparatus. However, the experimentally observed optical stochastic cooling of a single electron in IOTA validated the relevance of the classical electromagnetic field nature of the continuous electron-radiation interaction (as opposed to discrete instantaneous photon emissions and associated 'classical particle trajectory jumps') responsible for cooling and pointed towards innovative methods of experimental techniques to measure 'turn-by-turn' field correlations. Such measurements have the promise of bridging the transition from classical fields building up to discrete quantum transitions and enhance proper theoretical understanding.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Prototype X-ray and Gamma Detection with Cyclotron Radiation Emission Spectroscopy

Cyclotron radiation emission spectroscopy, or CRES, is a novel approach to measuring the energy of an electron. By trapping a free electron in a high magnetic field, it undergoes cyclotron motion and emits radiofrequency (RF) waves. The frequency of this RF radiation is directly related to the energy of the electron. Because many cycles of the RF emission are recorded, the energy resolution of the CRES system is on the order of a single electron volt. To make a CRES system sensitive to photons, a target gas is used to induce a photoelectric effect, producing the electron that is subsequently trapped. By adding the binding energy of the target atom, the energy of the incident photon may be reconstructed. Using a xenon target gas, photoelectric interactions dominate up to approximately 300 keV, covering not only all atomic shell X-rays of the elements, but many low-lying nuclear states as well, including key transuranic elements related to nuclear security. CRES holds the potential of maintaining single-eV resolution up to this 300-keV range, thereby surpassing current state-of-the-art detectors by a factor of 10-100. The instrumental resolution of the system is limited by the uniformity of the applied magnetic field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum synchrotron spectra from semirelativistic electrons in teragauss magnetic fields

Synchrotron spectra are calculated from quantum electrodynamic transition rates for thermal and power-law electron distributions. It is shown that quantum effects appear in thermal spectra when the photon energy is greater than the electron temperature, and in power-law spectra when the electron energy in units of the electron rest mass times the magnetic field strength in units of the critical field strength is of order unity. These spectra are compared with spectra calculated from the ultrarelativistic approximation for synchrotron emission. It is found that the approximation for the power-law spectra is good, and the approximation for thermal spectra produces the shape of the spectrum accurately but fails to give the correct normalization. Single photon pair creation masks the quantum effects for power-law distributions, so only modifications to thermal spectra are important for gamma-ray bursts.

Brainerd, J. J.↗

Advances in the photon avalanche luminescence of inorganic lanthanide-doped nanomaterials

Photon avalanche (PA)—where the absorption of a single photon initiates a ‘chain reaction’ of additional absorption and energy transfer events within a material—is a highly nonlinear optical process that results in upconverted light emission with an exceptionally steep dependence on the illumination intensity. Over 40 years following the first demonstration of photon avalanche emission in lanthanide-doped bulk crystals, PA emission has been achieved in nanometer-scale colloidal particles. The scaling of PA to nanomaterials has resulted in significant and rapid advances, such as luminescence imaging beyond the diffraction limit of light, optical thermometry and force sensing with (sub)micron spatial resolution, and all-optical data storage and processing. In this review, we discuss the fundamental principles underpinning PA and survey the studies leading to the development of nanoscale PA. Finally, we offer a perspective on how this knowledge can be used for the development of next-generation PA nanomaterials optimized for a broad range of applications, including mid-IR imaging, luminescence thermometry, (bio)sensing, optical data processing and nanophotonics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gamma-Ray Burst Spectral Indices: Evidence for Deceleration of Synchrotron Shocks

The current scenario for gamma-ray bursts (GRBs) involves internal shocks for the prompt GRB emission phase and external shocks for the afterglow phase. Assuming synchrotron emission from energetic shocked electrons. GRB spectra observed with a low-energy power-law spectral index greater than -2/3 (for positive photon number indices E(sup alpha) indicate a problem with this model. The remaining spectra can test the synchrotron shock model prediction that the emission from a single distribution of electrons, cooling rapidly, is responsible for both the low-energy and high-energy power-low portions of the spectra. We find that the inferred relationship between the two spectral indices of observed GRB spectra is inconsistent with the constraints from the model, posing another problem for the synchrotron shock emission model. To overcome this problem, we describe a model where the average of -1, rather than the value of -3/2 predicted for cooling electrons. Situations where this might arise have been discussed in other contexts, and involve deceleration of the internal shocks during the GRB phase.

Preece, R. D.↗

Front-End Design for SiPM-Based Monolithic Neutron Double Scatter Imagers

Neutron double scatter imaging exploits the kinematics of neutron elastic scattering to enable emission imaging of neutron sources. Due to the relatively low coincidence detection efficiency of fast neutrons in organic scintillator arrays, imaging efficiency for double scatter cameras can also be low. One method to realize significant gains in neutron coincidence detection efficiency is to develop neutron double scatter detectors which employ monolithic blocks of organic scintillator, instrumented with photosensor arrays on multiple faces to enable 3D position and multi-interaction time pickoff. Silicon photomultipliers (SiPMs) have several advantageous characteristics for this approach, including high photon detection efficiency (PDE), good single photon time resolution (SPTR), high gain that translates to single photon counting capabilities, and ability to be tiled into large arrays with high packing fraction and photosensitive area fill factor. However, they also have a tradeoff in high uncorrelated and correlated noise rates (dark counts from thermionic emissions and optical photon crosstalk generated during avalanche) which may complicate event positioning algorithms. We have evaluated the noise characteristics and SPTR of Hamamatsu S13360-6075 SiPMs with low noise, fast electronic readout for integration into a monolithic neutron scatter camera prototype. The sensors and electronic readout were implemented in a small-scale prototype detector in order to estimate expected noise performance for a monolithic neutron scatter camera and perform proof-of-concept measurements for scintillation photon counting and three-dimensional event positioning.

47 OTHER INSTRUMENTATION↗

Airborne Demonstration of Atmospheric Oxygen Optical Depth Measurements with an Integrated Path Differential Absorption Lidar

We report on an airborne demonstration of atmospheric oxygen (O2) optical depth measurements with an Integrated Path Differential Absorption (IPDA) lidar using a fiber-based laser transmitter and photon counting detectors. Accurate atmospheric temperature and pressure measurements are needed for NASA's Active Sensing of CO2 Emissions over Nights, Days and Seasons (ASCENDS) mission. Since O2 is uniformly mixed in the atmosphere, its spectrum can be used to estimate the dry mixing ratio of CO2. In its airborne configuration, the IPDA lidar uses an Erbium Doped Fiber amplifier, a frequency doubler and single photon counting detectors to measure O2 absorption at multiple wavelengths near 765 nm. This instrument was deployed in 2013 and 2014 aboard NASA's DC-8 airborne laboratory as part of two campaigns to measure CO2 mixing ratios over a wide range of topography and weather conditions from altitudes ranging between 3 km and 13 km. In this paper we will review a summary of the results from our flights, discuss the errors that limit the precision and accuracy of the measurement and identify possible areas of improvement.

Methane↗