Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “shape modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Electric micro fields in simulated two component plasmas

The statistical properties of local electric fields in an classical plasma are investigated by molecular dynamics (MD) simulation. Two-component plasma simulations of neutral hydrogen, protons and electrons for intermediate plasma coupling conditions, typically N{sub e}{approx_equal}10{sup 18}cm{sup -3}, T{sub e}{approx_equal}1eV, have been carried out. These simulations appear as a possible and very useful way to generate relevant microfield sample-sets appropriate for ion emitter lineshape simulations for plasma spectroscopy and to provide guidance for line shape modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Automated Classification of Disease Patterns from Echo-cardiography Images Based on Shape Features of the Left Ventricle

Computer assisted diagnosis using analysis of medical images is an area of active research in health informatics. This paper proposes a technique for indication of heart diseases by using information related to shapes of the left ventricle (LV). LV boundaries are tracked from echo-cardiography images taken from LV short axis view, corresponding to two disease conditions viz. dilated cardiomyopathy and hypertrophic cardiomyopathy, and discriminated from the normal condition. The LV shapes are modeled using shape histograms generated by plotting the frequency of normalized radii lengths drawn from the centroid to the periphery, against a specific number of bins. A 3-layer neural network activated by a log-sigmoid function is used to classify the shape histograms into one of the three classes. Experimentations on a dataset of 240 images show recognition accuracies of the order of 80%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Linearized spectrum correlation analysis for line emission measurements

A new spectral analysis method, Linearized Spectrum Correlation Analysis (LSCA), for charge exchange and passive ion Doppler spectroscopy is introduced to provide a means of measuring fast spectral line shape changes associated with ion-scale micro-instabilities. This analysis method is designed to resolve the fluctuations in the emission line shape from a stationary ion-scale wave. The method linearizes the fluctuations around a time-averaged line shape (e.g., Gaussian) and subdivides the spectral output channels into two sets to reduce contributions from uncorrelated fluctuations without averaging over the fast time dynamics. In principle, small fluctuations in the parameters used for a line shape model can be measured by evaluating the cross spectrum between different channel groupings to isolate a particular fluctuating quantity. High-frequency ion velocity measurements (100–200 kHz) were made by using this method. We also conducted simulations to compare LSCA with a moment analysis technique under a low photon count condition. Both experimental and synthetic measurements demonstrate the effectiveness of LSCA.

47 OTHER INSTRUMENTATION↗

Radar imaging and characterization of the binary near-earth asteroid (185851) 2000 DP107

The potentially hazardous asteroid (185851) 2000 DP107 was the first binary near-Earth asteroid to be imaged. Radar observations in 2000 provided images at 75 m resolution that revealed the shape, orbit, and spin-up formation mechanism of the binary. The asteroid made a more favorable flyby of the Earth in 2008, yielding images at 30 m resolution. We used these data to obtain shape models for the two components and to improve the estimates of the mutual orbit, component masses, and spin periods. The primary has a sidereal spin period of 2.7745 ± 0.0007 hr and is roughly spheroidal with an equivalent diameter of 863 m ± 5%. It has a mass of 4.656±0.43×10{sup 11} kg and a density of 1381 ± 244 kg m{sup −3}. It exhibits an equatorial ridge similar to the (66391) 1999 KW4 primary; however, the equatorial ridge in this case is not as regular and has a ∼300 m diameter concavity on one side. The secondary has a sidereal spin period of 1.77 ± 0.02 days commensurate with the orbital period. The secondary is slightly elongated and has overall dimensions of 377×314×268 m (6% uncertainties). Its mass is 0.178±0.021×10{sup 11} kg and its density is 1047 ± 230 kg m{sup −3}. The mutual orbit has a semimajor axis of 2.659 ± 0.08 km, an eccentricity of 0.019 ± 0.01, and a period of 1.7556 ± 0.0015 days. The normalized total angular momentum of this system exceeds the amount required for the expected spin-up formation mechanism. An increase of angular momentum from non-gravitational forces after binary formation is a possible explanation. The two components have similar radar reflectivity, suggesting a similar composition consistent with formation by spin-up. The secondary appears to exhibit a larger circular polarization ratio than the primary, suggesting a rougher surface or subsurface at radar wavelength scales.

79 ASTRONOMY AND ASTROPHYSICS↗

CONSTRAINTS ON THE MASS AND RADIUS OF THE NEUTRON STAR XTE J1807-294

The accreting millisecond pulsar XTE J1807-294 is studied through a pulse-shape modeling analysis. The model includes blackbody and Comptonized emission from the one visible hot spot and makes use of the Oblate Schwarzschild approximation for ray-tracing. We include a scattered light contribution, which accounts for flux scattered off an equatorial accretion disk to the observer including time delays in the scattered light. We give limits to mass and radius for XTE J1807-294 and compare these to limits determined for SAX J1808-3658 and XTE J1814-334 previously determined using similar methods. The resulting allowed region for mass-radius curves is small but consistent with a mass-radius relation with nearly constant radius ({approx}12 km) for masses between 1 and 2.5 solar masses.

79 ASTRONOMY AND ASTROPHYSICS↗

ON DETECTING TRANSIENT PHENOMENA

Transient phenomena are interesting and potentially highly revealing of details about the processes under observation and study that could otherwise go unnoticed. It is therefore important to maximize the sensitivity of the method used to identify such events. In this article, we present a general procedure based on the use of the likelihood function for identifying transients which is particularly suited for real-time applications because it requires no grouping or pre-processing of the data. The method makes use of all the information that is available in the data throughout the statistical decision-making process, and is suitable for a wide range of applications. Here we consider those most common in astrophysics, which involve searching for transient sources, events or features in images, time series, energy spectra, and power spectra, and demonstrate the use of the method in the case of a weak X-ray flare in a time series and a short-lived quasi-periodic oscillation in a power spectrum. We derive a fit statistic that is ideal for fitting arbitrarily shaped models to a power density distribution, which is of general interest in all applications involving periodogram analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Nonglobal correlations in collider physics

Despite their importance for precision QCD calculations, correlations between in- and out-of-jet regions of phase space have never directly been observed. These so-called non-global effects are present generically whenever a collider physics measurement is not explicitly dependent on radiation throughout the entire phase space. In this paper, we introduce a novel procedure based on mutual information, which allows us to isolate these non-global correlations between measurements made in different regions of phase space. We study this procedure both analytically and in Monte Carlo simulations in the context of observables measured on hadronic final states produced in e+e- collisions, though it is more widely applicable.The procedure exploits the sensitivity of soft radiation at large angles to non-global correlations, and we calculate these correlations through next-to-leading logarithmic accuracy. The bulk of these non-global correlations are found to be described in Monte Carlo simulation. They increase by the inclusion of non-perturbative effects, which we show can be incorporated in our calculation through the use of a model shape function. As a result, this procedure illuminates the source of non-global correlations and has connections more broadly to fundamental quantities in quantum field theory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pulse Pileup Analysis for a Double-Sided Silicon Strip Detector Using Variable Pulse Shapes

On account of pulse pileup, photon counting detectors (PCDs) suffer from count loss and energy distortion when operating in high count rate environments. Here, we researched the pulse pileup of a double-sided silicon strip detector (DSSSD) to evaluate its potential application in a mammography system. We analyzed the pulse pileup using pulses of varied shapes, where the shape of the pulse depends on the location of photon interaction within the detector. To obtain the shaped pulses, first, transient currents for photons interacting at different locations were simulated using a Technology Computer-Aided Design (TCAD) software. Next, the currents were shaped by a CR- RC 2 shaping circuit, calculated using Simulink. After obtaining these pulses, both the different orders of pileup and the energy spectrum were calculated by taking into account the following two factors: 1) spatial distribution of photon interactions within the detector and 2) time interval distribution between successive photons under a given photon flux. We found that for a DSSSD with a thickness of 300 μm, a pitch of 25 μm, and a strip length of 1 cm, under a bias voltage of 50 V, the variable pulse shape model predicts that the fraction free of pileup can be >90% under a photon flux of 3.75 Mcps/mm 2 (million counts per second per square mm). The DSSSD is a promising candidate for digital mammography applications.

47 OTHER INSTRUMENTATION↗

Automated selection of trabecular bone regions in knee radiographs

Osteoarthritic (OA) changes in knee joints can be assessed by analyzing the structure of trabecular bone (TB) in the tibia. This analysis is performed on TB regions selected manually by a human operator on x-ray images. Manual selection is time-consuming, tedious, and expensive. Even if a radiologist expert or highly trained person is available to select regions, high inter- and intraobserver variabilities are still possible. A fully automated image segmentation method was, therefore, developed to select the bone regions for numerical analyses of changes in bone structures. The newly developed method consists of image preprocessing, delineation of cortical bone plates (active shape model), and location of regions of interest (ROI). The method was trained on an independent set of 40 x-ray images. Automatically selected regions were compared to the ''gold standard'' that contains ROIs selected manually by a radiologist expert on 132 x-ray images. All images were acquired from subjects locked in a standardized standing position using a radiography rig. The size of each ROI is 12.8x12.8 mm. The automated method results showed a good agreement with the gold standard [similarity index (SI)=0.83 (medial) and 0.81 (lateral) and the offset=[-1.78, 1.27]x[-0.65,0.26] mm (medial) and [-2.15, 1.59]x[-0.58, 0.52] mm (lateral)]. Bland and Altman plots were constructed for fractal signatures, and changes of fractal dimensions (FD) to region offsets calculated between the gold standard and automatically selected regions were calculated. The plots showed a random scatter and the 95% confidence intervals were (-0.006, 0.008) and (-0.001, 0.011). The changes of FDs to region offsets were less than 0.035. Previous studies showed that differences in FDs between non-OA and OA bone regions were greater than 0.05. ROIs were also selected by a second radiologist and then evaluated. Results indicated that the newly developed method could replace a human operator and produces bone regions with an accuracy that is sufficient for fractal analyses of bone texture.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and testing of texture discriminators for the analysis of trabecular bone in proximal femur radiographs

Purpose: Texture analysis of femur radiographs may serve as a potential low cost technique to predict osteoporotic fracture risk and has received considerable attention in the past years. A further application of this technique may be the measurement of the quality of specific bone compartments to provide useful information for treatment of bone fractures. Two challenges of texture analysis are the selection of the best suitable texture measure and reproducible placement of regions of interest (ROIs). The goal of this in vitro study was to automatically place ROIs in radiographs of proximal femur specimens and to calculate correlations between various different texture analysis methods and the femurs' anchorage strength. Methods: Radiographs were obtained from 14 femoral specimens and bone mineral density (BMD) was measured in the femoral neck. Biomechanical testing was performed to assess the anchorage strength in terms of failure load, breakaway torque, and number of cycles. Images were segmented using a framework that is based on the usage of level sets and statistical in-shape models. Five ROIs were automatically placed in the head, upper and lower neck, trochanteric, and shaft compartment in an atlas subject. All other subjects were registered rigidly, affinely, and nonlinearly, and the resulting transformation was used to map the five ROIs onto the individual femora. Results: In each ROI, texture features were extracted using gray level co-occurence matrices (GLCM), third-order GLCM, morphological gradients (MGs), Minkowski dimensions (MDs), Minkowski functionals (MFs), Gaussian Markov random fields, and scaling index method (SIM). Coefficients of determination for each texture feature with parameters of anchorage strength were computed. In a stepwise multiregression analysis, the most predictive parameters were identified in different models. Texture features were highly correlated with anchorage strength estimated by the failure load of up to R{sup 2}=0.61 (MF and MG features, p<0.01) and were partially independent of BMD. The correlations were dependent on the choice of the ROI and the texture measure. The best predictive multiregression model for failure load R{sub adj}{sup 2}=0.86 (p<0.001) included a set of recently developed texture methods (MF and SIM) but excluded bone mineral density and commonly used texture measures. Conclusions: The results suggest that texture information contained in trabecular bone structure visualized on radiographs may predict whether an implant anchorage can be used and may determine the local bone quality from preoperative radiographs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reconstruction of 3D lung models from 2D planning data sets for Hodgkin's lymphoma patients using combined deformable image registration and navigator channels

Purpose: Late complications (cardiac toxicities, secondary lung, and breast cancer) remain a significant concern in the radiation treatment of Hodgkin's lymphoma (HL). To address this issue, predictive dose-risk models could potentially be used to estimate radiotherapy-related late toxicities. This study investigates the use of deformable image registration (DIR) and navigator channels (NCs) to reconstruct 3D lung models from 2D radiographic planning images, in order to retrospectively calculate the treatment dose exposure to HL patients treated with 2D planning, which are now experiencing late effects. Methods: Three-dimensional planning CT images of 52 current HL patients were acquired. 12 image sets were used to construct a male and a female population lung model. 23 ''Reference'' images were used to generate lung deformation adaptation templates, constructed by deforming the population model into each patient-specific lung geometry using a biomechanical-based DIR algorithm, MORFEUS. 17 ''Test'' patients were used to test the accuracy of the reconstruction technique by adapting existing templates using 2D digitally reconstructed radiographs. The adaptation process included three steps. First, a Reference patient was matched to a Test patient by thorax measurements. Second, four NCs (small regions of interest) were placed on the lung boundary to calculate 1D differences in lung edges. Third, the Reference lung model was adapted to the Test patient's lung using the 1D edge differences. The Reference-adapted Test model was then compared to the 3D lung contours of the actual Test patient by computing their percentage volume overlap (POL) and Dice coefficient. Results: The average percentage overlapping volumes and Dice coefficient expressed as a percentage between the adapted and actual Test models were found to be 89.2{+-}3.9% (Right lung=88.8%; Left lung=89.6%) and 89.3{+-}2.7% (Right=88.5%; Left=90.2%), respectively. Paired T-tests demonstrated that the volumetric reconstruction method made a statistically significant improvement to the population lung model shape (p<0.05). The error in the results were also comparable to the volume overlap difference observed between inhale and exhale lung volumes during free-breathing respiratory motion (POL:p=0.43; Dice:p=0.20), which implies that the accuracies of the reconstruction method are within breathing constraints and would not be the confining factor in estimating normal tissue dose exposure. Conclusions: The result findings show that the DIR-NC technique can achieve a high degree of reconstruction accuracy, and could be useful in approximating 3D dosimetric representations of historical 2D treatment. In turn, this could provide a better understanding of the biophysical relationship between dose-volume exposure and late term radiotherapy effects.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-F-CAMPUS-I-01: EIT Imaging to Monitor Human Salivary Gland Functionality: A Feasibility Study

Purpose: Clinically, there exists a need to develop a non-invasive technique for monitoring salivary activity. In this study, we investigate the feasibility of a using the electrical conductivity information from Electrical Impedance Tomography (EIT) to monitor salivary flow activity. Methods: To acquire EIT data, eight Ag/AgCl ECG electrodes were placed around the mandible of the subject. An EIT scan was obtained by injecting current at 50 KHz, 0.4 mA through each pair of electrodes and recording voltage across other electrode pairs. The functional conductivity image was obtained through reconstruction of the voltage data, using Electrical Impedance Tomography and Diffuse Optical Tomography Reconstruction Software (EIDORS) in Matlab. In using EIDORS, forward solution was obtained using a user-defined finite element model shape and inverse solution was obtained using one-step Gaussian solver. EIT scans of volunteer research team members were acquired for three different physiological states: pre-stimulation, stimulation and post-stimulation. For pre-stimulation phase, data were collected in intervals of 5 minutes for 15 minutes. The salivary glands were then stimulated in the subject using lemon and the data were collected immediately. Post-stimulation data were collected at 4 different timings after stimulation. Results: Variations were observed in the electrical conductivity patterns near parotid regions between the pre- and post-stimulation stages. The three images acquired during the 15 minute pre-stimulation phase showed no major changes in the conductivity. Immediately after stimulation, electrical conductivity increased near parotid regions and 15 minutes later slowly returned to pre-stimulation level. Conclusion: In the present study involving human subjects, the change in electrical conductivity pattern shown in the EIT images, acquired at different times with and without stimulation of salivary glands, appeared to be consistent with the change in salivary gland activity. The conductivity changes imaged through EIT are potentially useful for the purpose of salivary monitoring.

60 APPLIED LIFE SCIENCES↗

SU-D-207A-01: Female Pelvic Synthetic CT Generation Based On Joint Shape and Intensity Analysis

Purpose: To develop a method for generating female pelvic synthetic CT (MRCT) images from a single MR scan and evaluate its utility in radiotherapy. Methods: Under IRB-approval, an imaging sequence (T1-VIBE-Dixon) was acquired for 10 patients. This sequence yields 3 useful image volumes of different contrast (“in-phase” T1-weighted, fat and water). A previously published pelvic bone shape model was used to generate a rough bone mask for each patient. A modified fuzzy c-means classification was performed on the multi spectral MR data, with a regularization term that utilizes the prior knowledge provided by the bone mask and addresses the intensity overlap between different tissue types. A weighted sum of classification probabilities with attenuation values yielded MRCT volumes. The mean absolute error (MAE) between MRCT and real CT on various regions was calculated following deformable alignment (Velocity). Intensity modulated Treatment plans based on actual CT and MRCT were made and compared. Results: The average/standard deviation of MAE across 10 patients was 10.1/6.7 HU for muscle, 6.7/4.6 HU for fat, 136.9/53.5 HU for bony tissues under 850 HU (97% of total bone volume), 188.9/119.3 HU for bony tissues above 850 HU and 17.3/13.3 HU for intrapelvic soft tissues. Calculated doses were comparable for plans generated on CT and calculated using MRCT densities or vice versa, with differences in PTV D99% (mean/σ) of (–0.1/0.2 Gy) and (0.3/0.2 Gy), PTV D0.5cc of (–0.3/0.2 Gy) and (–0.4/1.7 Gy). OAR differences were similarly small for comparable structures, with differences in bowel V50Gy of (–0.3/0.2%) and (0.0/0.2%), femur V30Gy of (0.7/1.2%) and (0.2/1.2%), sacrum V20GY of (0.0/0.1%) and (–0.1/1.1%) and mean pelvic V20Gy of (0.0/0.1%) and (0.6/1.8%). Conclusion: MRCT based on a single imaging sequence in the female pelvis is feasible, with acceptably small variations in attenuation estimates and calculated doses to target and critical organs. Work supported by NIHR01EB016079.

60 APPLIED LIFE SCIENCES↗

SU-F-T-172: A Method for Log File QA On An IBA Proteus System for Patient Specific Spot Scanning Quality Assurance

Purpose: The use of log files to perform patient specific quality assurance for both protons and IMRT has been established. Here, we extend that approach to a proprietary log file format and compare our results to measurements in phantom. Our goal was to generate a system that would permit gross errors to be found within 3 fractions until direct measurements. This approach could eventually replace direct measurements. Methods: Spot scanning protons pass through multi-wire ionization chambers which provide information about the charge, location, and size of each delivered spot. We have generated a program that calculates the dose in phantom from these log files and compares the measurements with the plan. The program has 3 different spot shape models: single Gaussian, double Gaussian and the ASTROID model. The program was benchmarked across different treatment sites for 23 patients and 74 fields. Results: The dose calculated from the log files were compared to those generate by the treatment planning system (Raystation). While the dual Gaussian model often gave better agreement, overall, the ASTROID model gave the most consistent results. Using a 5%–3 mm gamma with a 90% passing criteria and excluding doses below 20% of prescription all patient samples passed. However, the degree of agreement of the log file approach was slightly worse than that of the chamber array measurement approach. Operationally, this implies that if the beam passes the log file model, it should pass direct measurement. Conclusion: We have established and benchmarked a model for log file QA in an IBA proteus plus system. The choice of optimal spot model for a given class of patients may be affected by factors such as site, field size, and range shifter and will be investigated further.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRA-01: Abdominal Synthetic CT Generation in Support of Liver SBRT Dose Calculation

Purpose: To demonstrate and validate a technique for generating MRI-derived synthetic CT volumes (MRCTs) in support of adaptive liver SBRT. Methods: Under IRB approval, ten hepatocellular carcinoma patients were scanned using a single MR sequence (T1 Dixon-VIBE), yielding inherently-registered water, fat, and T1-weighted images. Air-containing voxels were identified by intensity thresholding. The envelope of the anterior vertebral bodies was segmented from the fat image by fitting a shape model to vertebral body candidate voxels, then using level sets to expand the contour outward. Fuzzy-C-Means (FCM) was then used to classify each non-air voxel in the image as fat, water, bone, or marrow. Bone and marrow only were classified within the vertebral body envelope. The MRCT was created by integrating the product of the FCM class probability with the assigned class density for each voxel. The resulting MRCTs were deformably aligned with planning CTs and 2-ARC SBRT VMAT plans were optimized on the MRCT density maps. Fluence was copied onto the CT density grids and dose recalculated. Results: The MRCTs faithfully reproduced most of the features visible in the corresponding CT image volumes, with exceptions of ribs and posterior spinous processes. The liver, vertebral bodies, kidneys, spleen and cord all had median HU differences of less than 75 between MRCT and CT images. PTV D99% values had an average 0.2% difference (standard deviation: 0.46%) between calculations on MRCT and CT density grids. The maximum difference in dose to 0.1cc of the PTV was 0.25% (std:0.49%). OAR dose differences were similarly small (mean:0.03Gy, std:0.26Gy). The largest normal tissue complication percentage (NTCP) difference was 1.48% (mean:0.06%, std:0.54%). Conclusions: MRCTs from a single abdominal imaging sequence are promising for use in SBRT dose calculation. Future work will focus on extending models to better define bones in the upper abdomen. Supported by NIHR01EB016079 and NIH1L30CA199594-01.

60 APPLIED LIFE SCIENCES↗

Automatic segmentation of the glenohumeral cartilages from magnetic resonance images

Purpose: Magnetic resonance (MR) imaging plays a key role in investigating early degenerative disorders and traumatic injuries of the glenohumeral cartilages. Subtle morphometric and biochemical changes of potential relevance to clinical diagnosis, treatment planning, and evaluation can be assessed from measurements derived from in vivo MR segmentation of the cartilages. However, segmentation of the glenohumeral cartilages, using approaches spanning manual to automated methods, is technically challenging, due to their thin, curved structure and overlapping intensities of surrounding tissues. Automatic segmentation of the glenohumeral cartilages from MR imaging is not at the same level compared to the weight-bearing knee and hip joint cartilages despite the potential applications with respect to clinical investigation of shoulder disorders. In this work, the authors present a fully automated segmentation method for the glenohumeral cartilages using MR images of healthy shoulders. Methods: The method involves automated segmentation of the humerus and scapula bones using 3D active shape models, the extraction of the expected bone–cartilage interface, and cartilage segmentation using a graph-based method. The cartilage segmentation uses localization, patient specific tissue estimation, and a model of the cartilage thickness variation. The accuracy of this method was experimentally validated using a leave-one-out scheme on a database of MR images acquired from 44 asymptomatic subjects with a true fast imaging with steady state precession sequence on a 3 T scanner (Siemens Trio) using a dedicated shoulder coil. The automated results were compared to manual segmentations from two experts (an experienced radiographer and an experienced musculoskeletal anatomist) using the Dice similarity coefficient (DSC) and mean absolute surface distance (MASD) metrics. Results: Accurate and precise bone segmentations were achieved with mean DSC of 0.98 and 0.93 for the humeral head and glenoid fossa, respectively. Mean DSC scores of 0.74 and 0.72 were obtained for the humeral and glenoid cartilage volumes, respectively. The manual interobserver reliability evaluated by DSC was 0.80 ± 0.03 and 0.76 ± 0.04 for the two cartilages, implying that the automated results were within an acceptable 10% difference. The MASD between the automatic and the corresponding manual cartilage segmentations was less than 0.4 mm (previous studies reported mean cartilage thickness of 1.3 mm). Conclusions: This work shows the feasibility of volumetric segmentation and separation of the glenohumeral cartilages from MR images. To their knowledge, this is the first fully automated algorithm for volumetric segmentation of the individual glenohumeral cartilages from MR images. The approach was validated against manual segmentations from experienced analysts. In future work, the approach will be validated on imaging datasets acquired with various MR contrasts in patients.

60 APPLIED LIFE SCIENCES↗

Temperature switching of cavity modes in InN microcrystals

InN optical cavities supporting low-order whispering-gallery modes up to room temperature are formed by molecular-beam epitaxy on patterned substrates. The observed switching of the mode type with increasing temperature is explained in terms of changes in the optical parameters due to a shift of the absorption edge and modification of its shape. Modeling taking into account a variation in the refractive index reproduces the typical distributions of the electromagnetic-field intensity in the cavities.

36 MATERIALS SCIENCE↗

DETECTION OF ROTATIONAL SPECTRAL VARIATION ON THE M-TYPE ASTEROID (16) PSYCHE

The asteroid (16) Psyche is of scientific interest because it contains ∼1% of the total mass of the asteroid belt and is thought to be the remnant metallic core of a protoplanet. Radar observations have indicated the significant presence of metal on the surface with a small percentage of silicates. Prior ground-based observations showed rotational variations in the near-infrared (NIR) spectra and radar albedo of this asteroid. However, no comprehensive study that combines multi-wavelength data has been conducted so far. Here we present rotationally resolved NIR spectra (0.7–2.5 μ m) of (16) Psyche obtained with the NASA Infrared Telescope Facility. These data have been combined with shape models of the asteroid for each rotation phase. Spectral band parameters extracted from the NIR spectra show that the pyroxene band center varies from ∼0.92 to 0.94 μ m. Band center values were used to calculate the pyroxene chemistry of the asteroid, whose average value was found to be Fs{sub 30}En{sub 65}Wo{sub 5}. Variations in the band depth (BD) were also observed, with values ranging from 1.0% to 1.5%. Using a new laboratory spectral calibration method, we estimated an average orthopyroxene content of 6% ± 1%. The mass-deficit region of Psyche, which exhibits the highest radar albedo, also shows the highest value for the spectral slope and the minimum BD. The spectral characteristics of Psyche suggest that its parent body did not have the typical structure expected for a differentiated body or that the sequence of events that led to its current state was more complex than previously thought.

79 ASTRONOMY AND ASTROPHYSICS↗