Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Applications of fuzzy logic and best-worst method for tritium sensor selection

Accurate assessment of tritium as a fuel source is critical in fusion reactions, necessitating effective sensor evaluation methods. This study investigates a multi-criteria decision-making framework for selecting tritium sensors, integrating fuzzy logic to enhance decision quality. Initial attempts at applying fuzzy logic were found to be too elementary and failed to capture the complexity of multi-criteria selection; this prompted a refined approach that incorporated expert insights and advanced ranking techniques for sensor evaluation. The research used a two-stage methodology. In the first stage, important criteria and sub-criteria for sensor performance were identified and defined. These criteria were then weighted and scored using a fuzzy best-worst method, drawing upon expert opinions to ensure relevance and validity. The second stage involved interpreting information about varying sensors to rank them based on their overall criteria scores, encouraging the selection of the most suitable options. The result of the study is a proposed method for effective sensor selection in fusion reactors, which in turn will significantly improve the reliability of tritium monitoring in fusion applications.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

New atmospheric sensor analysis study

The functional capabilities of the ESAD Research Computing Facility are discussed. The system is used in processing atmospheric measurements which are used in the evaluation of sensor performance, conducting design-concept simulation studies, and also in modeling the physical and dynamical nature of atmospheric processes. The results may then be evaluated to furnish inputs into the final design specifications for new space sensors intended for future Spacelab, Space Station, and free-flying missions. In addition, data gathered from these missions may subsequently be analyzed to provide better understanding of requirements for numerical modeling of atmospheric phenomena.

Parker, K. G.↗

Edge‐Driven Fringe‐Field Effects, Reduced Screening, and Bandgap Widening in Graphene Nanoribbons Enable Single‑Molecule Sensitivity

Graphene nanoribbons (GNRs) offer promising platforms for single‐molecule sensing due to their quasi‐1D channels and discrete electronic states, providing superior sensitivity toward molecular perturbations. While prior studies emphasize smoother edges as essential for optimal performance, the potential benefits of controlled edge roughness remain largely unexplored. Additionally, most investigations focus on GNR arrays, leaving critical edge‐ and width‐dependent factors, including fringe fields, bandgap widening, interactions between adsorbing molecules and GNR atoms, density of states (DOS) suppression, and electrostatic screening lengths, and their collective impact on sensitivity, poorly understood. Here, in this work, we fabricated field‐effect transistors using individual GNRs (widths: 200–20 nm) and characterized their response to molecular adsorption with perfluorooctanoic acid as the model analyte. Narrower ribbons displayed significantly enhanced sensitivity, yielding a coverage‐normalized response of 116 ± 10 mV per molecule in 20 nm‐wide GNRs (from calibrated ensemble Dirac‐point shifts). Experimental and theoretical analyses reveal that this heightened sensitivity arises from stronger fringe fields, width‐dependent quantum confinement effects, reduced DOS, and increased edge roughness that facilitates molecular anchoring, enhanced orbital overlap, and improved charge transfer efficiency. Our findings challenge the conventional assumption that smoother edges inherently enhance sensor performance, demonstrating that controlled edge disorder substantially boosts molecular sensitivity in GNR sensors.

36 MATERIALS SCIENCE↗

Orbital Path and Spacecraft Attitude Correction for the MODIS Lunar Spatial Characterization

For the Moderate Resolution Imaging Spectroradiometer(MODIS) on the Terra and Aqua platforms, regularlyscheduled lunar observations using spacecraft roll maneuvershave been used extensively for sensor characterization. Whilethe primary purpose of these observations is for radiometriccalibration of the reflective solar bands, they have also beenleveraged for a number of other sensor performance assessments,such as the band-to-band (BBR) and detector-to-detector (DDR)spatial registration. The spatial registration calculations arecomplicated by the fact that the Moon does not move in astraight path across the sensor field-of-view (FOV). This path isdetermined by the relative orbital motion between the spacecraftand the Moon and the instrument attitude error that resultsfrom the roll maneuver. In this work, we develop a correctionfor the MODIS lunar spatial characterization measurements bycalculating the predicted path of the Moon across the sensor FOVusing spacecraft and lunar ephemeris data to model the relativeorbital motion between the spacecraft and the Moon along withspacecraft attitude error data acquired during the roll maneuver.The difference between measured and predicted positions of theMoon in the MODIS FOV can be used to calculate the BBRand DDR results. Since the predicted path across the FOV willbe the same for each band, the BBR results will be minimallyaffected. However, we will show that the along-scan spread inthe DDR can be significantly reduced, which results in a muchgreater consistency throughout the full mission for both Aquaand Terra MODIS.

Truman Wilson↗

Testing Instrument Extremes in the TREAT Facility

TREAT is a transient power-shaping reactor whose primary mission is to enhance safety performance by testing nuclear fuels and materials under thermodynamic and neutronic conditions ranging from off-normal to extreme. Transient testing of nuclear fuels is analogous to car crash testing, in that the dramatic changes commonly seen when comparing the test specimens' initial and final state points necessitate in-situ measuring in order to interpret and understand the evolution of the experiment. TREAT’s experiment design strategy utilizes a highly reconfigurable and accessible reactor core that affords flexibility when installing experiment devices, thanks to the lack of a primary coolant boundary and the inclusion of multiple access points in the reactor bioshield. Within the experiment devices, the test specimens (which are integrated with their test environments), desired instrumentation diagnostics, and safety considerations are all contained in a single engineered package. The experiments encompass various types of environments (e.g., water, sodium, and gas at temperature and pressure), as well as a range of control options (e.g., static or flowing coolants). The experimental conditions are uniquely representative of advanced reactors, providing challenges to sensor performance but also affording a unique opportunity for development and qualification of sensors suited to these environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiplexable high-temperature stable and low-loss intrinsic Fabry-Perot in-fiber sensors through nanograting engineering

This paper presents a method of using femtosecond laser inscribed nanograting as low-loss– and high-temperature–stable in-fiber reflectors. By introducing a pair of nanograting inside the core of a single-mode optical fiber, an intrinsic Fabry-Perot interferometer can be created for high-temperature sensing applications. The morphology of the nanograting inscribed in fiber cores was engineered by tuning the fabrication conditions to achieve a high fringe visibility of 0.49 and low insertion loss of 0.002 dB per sensor. Using a white light interferometry demodulation algorithm, we demonstrate the temperature sensitivity, cross-talk, and spatial multiplexability of sensor arrays. Both the sensor performance and stability were studied from room temperature to 1000°C with cyclic heating and cooling. Our results demonstrate a femtosecond direct laser writing technique capable of producing highly multiplexable in-fiber intrinsic Fabry-Perot interferometer sensor devices with high fringe contrast, high sensitivity, and low-loss for application in harsh environmental conditions.

Wang, Mohan (ORCID:0000000166784993)↗

TPSAS-NF1676L-18074-DND

Motivations - Radiative Transfer (RT) model is a component in satellite remote sensing (Observation System Simulation Experiment, sensor performance end-to-end simulations or sensitivity studies, and retrieval and data assimilations); - Line-by-line RT model is too slow, over a million RT needed to cover infrared spectral region; - Traditional Channel-based RT models deal with one channel at a time. Modern sensors have thousands of channels and 0.1-1 million spectra per day, only 4-10% of data are used in satellite data assimilations (too slow for climate OSSE). It is essential to have a RT model: - Accurate and fast - Works in all spectral regions - Includes as accurate physics as possible - Takes advantage of spectral correlations - Can handle cloud and aerosols PCRTM (Principal Component-based Radiative Transfer model) was developed to satisfy the need listed above.

Xu Liu↗

TRMM Microwave Imager (TMI) Updates for Final Data Version Release

The Tropical Rainfall Measuring Mission (TRMM) Microwave Imager (TMI) dataset released by the Precipitation Processing System (PPS) will be updated to a final version within the next year. These updates are based on increased knowledge in recent years of radiometer calibration and sensor performance issues. In particular, the Global Precipitation Measurement (GPM) Microwave Imager (GMI) is used as a model for many of the TMI version updates. This paper discusses four aspects of the TMI data product that will be improved: spacecraft attitude, calibration and quality control, along-scan bias corrections, and sensor pointing accuracy. These updates will be incorporated into the final TMI data version, improving the quality of the data product and ensuring accurate geophysical parameters can be derived from TMI.

Tropical Rainfall Measuring Mission↗

From Quantum to Classical: Sensing Materials, Methods, and Platforms for Energy

This presentation covers several ongoing sensors projects at NETL, including the use of quantum sensors for energy sector applications (e.g. infrastructure monitoring, critical metal detection, grid modernization) as well as NETL-developed materials and platforms for detecting economically critical metals including rare earth elements, cobalt, and aluminum. Taken together, these projects demonstrate NETL's leadership in unleashing American energy through the development of high performance sensors for reliable energy production and consumption.

critical minerals↗

MODIS On-orbit Calibration Uncertainty Assessment

MODIS has 20 reflective solar bands (RSB) and 16 thermal emissive bands (TEB). Compared to its heritage sensors, MODIS was developed with very stringent calibration uncertainty requirements. As a result, MODIS was designed and built with a set of on-board calibrators (OBC), which allow key sensor performance parameters and on-orbit calibration coefficients to be monitored and updated. In terms of its calibration traceability, MODIS RSB calibration is reflectance based using an on-board solar diffuser (SD) and the TEB calibration is radiance based using an on-board blackbody (BB). In addition to on-orbit calibration coefficients derived from its OBC, calibration parameters determined from sensor pre-launch calibration and characterization are used in both the RSB and TEB calibration and retrieval algorithms. This paper provides a brief description of MODIS calibration methodologies and an in-depth analysis of its on-orbit calibration uncertainties. Also discussed in this paper are uncertainty contributions from individual components and differences due to Terra and Aqua MODIS instrument characteristics and on-orbit performance.

Chiang, Vincent↗

Earth radiation budget measurement from a spinning satellite: Conceptual design of detectors

The conceptual design, sensor characteristics, sensor performance and accuracy, and spacecraft and orbital requirements for a spinning wide-field-of-view earth energy budget detector were investigated. The scientific requirements for measurement of the earth's radiative energy budget are presented. Other topics discussed include the observing system concept, solar constant radiometer design, plane flux wide FOV sensor design, fast active cavity theory, fast active cavity design and error analysis, thermopile detectors as an alternative, pre-flight and in-flight calibration plane, system error summary, and interface requirements.

Sromovsky, L. A.↗

Spatial Registration Assessments for the SNPP and N20 VIIRS Reflective Solar Bands Using Unscheduled Lunar Observations

The Visible Infrared Imaging Radiometer Suite (VIIRS) is a multi-spectral Earth-observing instrument on board the Suomi-NPP (SNPP) and NOAA-20 (N20) spacecraft, with spectral bands ranging in wavelength from 0.41 to 12.2 μm. For the reflective solar bands (RSB), the bands are calibrated on orbit using both solar diffuser (SD) and lunar observations. The lunar observations use near-monthly scheduled spacecraft maneuvers in order to view the Moon within a desired phase angle range. While the primary purpose of the maneuvers is for radiometric calibration, these observations can also be used to characterize the spatial performance of the instrument, including the band-to-band and detector-to-detector registration (BBR/DDR). The Moon can also be observed without spacecraft maneuvers. However, these observations are over a larger phase angle range. While the geometry of these unscheduled observations is more varied, they can still be used to assess the sensor performance. In this work, we will use unscheduled Moon data to analyze the BBR and DDR of the SNPP and N20 VIIRS RSB. For the BBR, we implemented an image cross-correlation approach, which removes the residual oscillations in the trending data when compared to previous methodologies. For the DDR, we developed an edge fitting approach that accounts for the lunar motion across the VIIRS focal plane array on a scan-by-scan basis using lunar and satellite ephemeris data. In our analysis, we find that the BBR and DDR for both VIIRS RSB are stable on orbit.

Band-to-band registration (BBR)↗

Evaluation of the Reliability of Passive Infrared (PIR) Occupancy Sensors for Residential Indoor Lighting

Solid-state lighting (SSL) technologies have penetrated the general illumination market in recent years, largely replacing conventional technologies such as incandescent and fluorescent lighting. Most of the initial excitement about light-emitting diode (LED) sources for SSL devices focused on their energy savings potential resulting from vast improvements in source efficiency and luminous efficacy compared with conventional illumination products. More recently, the focus has shifted toward other aspects of lighting application efficiency, namely intensity effectiveness and spectral efficiency, because of the ease of controlling both the light intensity of LEDs with drive voltage and the color properties of the LED-based illuminators. To capitalize on the energy savings of increased intensity effectiveness and spectral efficiency, a lighting control system (LCS) is often used. While the current penetration of LCSs is relatively modest, it is anticipated that lighting controls (i.e., connected lighting, controls and LED and conventional lighting) could have an installed penetration as higher as 46% by the year 2035, saving an additional 1.3 quads of energy. Despite the large energy savings that can be gained from using LCSs, standard test methods for evaluating sensors employed in LCSs and reliability data of the LCSs and their components are generally lacking. The National Electrical Manufacturers Association (NEMA) developed the only standard, NEMA WD 7-2011 (R2016), to test occupancy and motion sensor performance (herein referred to as “the NEMA protocol”). In a previous U.S. Department of Energy (DOE) effort, some concerns of the NEMA protocol were identified (e.g., strict height and weight limits on test subjects, large amounts of manual effort, sometimes inconsistent repeatability). During the current work, a consistent detection length test (DLT) and a Robotic Sensor Evaluation System (RoboSES) were developed to alleviate some of these concerns. RoboSES acts as a human surrogate by using thermal pads on a mannequin and a remote-controlled mobile base to test a sensor’s field of view (FOV). This report builds on the earlier DOE efforts to understand sensor technologies used in LCSs for general illumination. Specifically, this report describes the optimization of RoboSES, characterizes and establishes test methods to assess the reliability of multiple passive infrared (PIR) sensors, and reports the findings of robustness and reliability testing on two commercial PIR sensors intended for residential applications. The information presented in this report is gained from up to 4,000 hours (hrs) of accelerated stress tests (ASTs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic Modeling, Simulation, and Analysis of Orbiting Sample Capture for Potential Mars Sample Return

The current notional architecture for the Mars Sample Return (MSR) campaign would require autonomous on-orbit rendezvous and capture of a sample container after it has been delivered to Mars orbit by a preceding MSR mission. As part of the complete orbital payload known as the Capture, Contain, and Return System (CCRS), a concept has been developed for autonomously sensing and capturing this Orbiting Sample (OS) container. The concept, comprised of a capture mechanism and multiple optical break-beam arrays, would detect and enclose the OS into CCRS, and engage a dust-tight seal to prevent the escape of the OS or other unsterilized particles. A challenging goal for the system is to close the lid prior to the OS coming into physical contact after entering CCRS in order to reduce the risk of unsterilized Mars particles on the surface of the OS from contaminating the outside of the spacecraft. The mechanical and sensor performance requirements were driven by the broader architecture of CCRS, OS rendezvous parameters, and Planetary Protection requirements regarding the interaction and handling of the OS. The mechanism and break-beam array concepts were designed accordingly, and kinematic simulations of the mechanism’s behavior, combined with a Monte-Carlo simulation of OS rendezvous/collision behaviors and corresponding breakbeam sensor responses verify compliance.

Ishigo, Alyssa↗

An Empirical State Error Covariance Matrix Orbit Determination Example

State estimation techniques serve effectively to provide mean state estimates. However, the state error covariance matrices provided as part of these techniques suffer from some degree of lack of confidence in their ability to adequately describe the uncertainty in the estimated states. A specific problem with the traditional form of state error covariance matrices is that they represent only a mapping of the assumed observation error characteristics into the state space. Any errors that arise from other sources (environment modeling, precision, etc.) are not directly represented in a traditional, theoretical state error covariance matrix. First, consider that an actual observation contains only measurement error and that an estimated observation contains all other errors, known and unknown. Then it follows that a measurement residual (the difference between expected and observed measurements) contains all errors for that measurement. Therefore, a direct and appropriate inclusion of the actual measurement residuals in the state error covariance matrix of the estimate will result in an empirical state error covariance matrix. This empirical state error covariance matrix will fully include all of the errors in the state estimate. The empirical error covariance matrix is determined from a literal reinterpretation of the equations involved in the weighted least squares estimation algorithm. It is a formally correct, empirical state error covariance matrix obtained through use of the average form of the weighted measurement residual variance performance index rather than the usual total weighted residual form. Based on its formulation, this matrix will contain the total uncertainty in the state estimate, regardless as to the source of the uncertainty and whether the source is anticipated or not. It is expected that the empirical error covariance matrix will give a better, statistical representation of the state error in poorly modeled systems or when sensor performance is suspect. In its most straight forward form, the technique only requires supplemental calculations to be added to existing batch estimation algorithms. In the current problem being studied a truth model making use of gravity with spherical, J2 and J4 terms plus a standard exponential type atmosphere with simple diurnal and random walk components is used. The ability of the empirical state error covariance matrix to account for errors is investigated under four scenarios during orbit estimation. These scenarios are: exact modeling under known measurement errors, exact modeling under corrupted measurement errors, inexact modeling under known measurement errors, and inexact modeling under corrupted measurement errors. For this problem a simple analog of a distributed space surveillance network is used. The sensors in this network make only range measurements and with simple normally distributed measurement errors. The sensors are assumed to have full horizon to horizon viewing at any azimuth. For definiteness, an orbit at the approximate altitude and inclination of the International Space Station is used for the study. The comparison analyses of the data involve only total vectors. No investigation of specific orbital elements is undertaken. The total vector analyses will look at the chisquare values of the error in the difference between the estimated state and the true modeled state using both the empirical and theoretical error covariance matrices for each of scenario.

Frisbee, Joseph H., Jr.↗

MODIS Radiometric Calibration and Uncertainty Assessment

Since launch, Terra and Aqua MODIS have collected more than II and 9 years of datasets for comprehensive studies of the Earth's land, ocean, and atmospheric properties. MODIS observations are made in 36 spectral bands: 20 reflective solar bands (RSB) and 16 thermal emissive bands (TEB). Compared to its heritage sensors, MODIS was developed with very stringent calibration and uncertainty requirements. As a result, MODIS was designed and built with a set of state of the art on-board calibrators (OBC), which allow key sensor performance parameters and on-orbit calibration coefficients to be monitored and updated if necessary. In terms of its calibration traceability, MODIS RSB calibration is reflectance based using an on-board solar diffuser (SD) and the TEB calibration is radiance based using an on-board blackbody (BB). In addition to on-orbit calibration coefficients derived from its OBC, calibration parameters determined from sensor pre-launch calibration and characterization are used in both the RSB and TEB calibration and retrieval algorithms. This paper provides a brief description of MODIS calibration methodologies and discusses details of its on-orbit calibration uncertainties. It assesses uncertainty contributions from individual components and differences between Terra and Aqua MODIS due to their design characteristics and on-orbit periormance. Also discussed in this paper is the use of MODIS LIB uncertainty index CUI) product.

Xiong, Xiaoxiong↗

Improving OFDR Distributed Fiber Sensing by Fibers With Enhanced Rayleigh Backscattering and Image Processing

This article investigates using optical fibers with enhanced backscattering profiles to improve distributed fiber sensor performance and reduce instrumentation costs. Using a femtosecond (fs) laser direct writing technique, the Rayleigh backscattering profile of a standard telecom fiber was enhanced by more than 40 dB to improve the signal-to-noise ratio (SNR) for optical frequency domain reflectometry (OFDR). The enhanced backscattering signals enable effectively distributed strain measurements using a low-cost tunable laser (TL). Median filtering is applied to denoise cross correlation results to further improve measurement outcomes. Results presented in this article show that a TL with a 1-nm tuning range, which is far less than the tuning range used in commercial OFDR interrogators, can perform effectively distributed strain measurements using sensing fibers with enhanced backscattering profiles. The sensing fiber with over 40-dB backscattering enhancement achieved 4.8-cm spatial resolution in strain measurements with a root mean square accuracy of less than 2.70 με when 10–50 με were exerted to the sensing fiber. In conclusion, results presented in this article reveal both the potential and limitations of sensing fibers with enhanced backscattering for OFDR-based distributed fiber sensors.

42 ENGINEERING↗

Polymer Electrolyte-Based Ambient Temperature Oxygen Microsensors for Environmental Monitoring

An ambient temperature oxygen microsensor, based on a Nafion polymer electrolyte, has been developed and was microfabricated using thin-film technologies. A challenge in the operation of Nafion-based sensor systems is that the conductivity of Nafion film depends on the humidity in the film. Nafion film loses conductivity when the moisture content in the film is too low, which can affect sensor operation. The advancement here is the identification of a method to retain the operation of the Nafion films in lower humidity environments. Certain salts can hold water molecules in the Nafion film structure at room temperature. By mixing salts with the Nafion solution, water molecules can be homogeneously distributed in the Nafion film increasing the film s hydration to prevent Nafion film from being dried out in low-humidity environment. The presence of organics provides extra sites in the Nafion film to promote proton (H+) mobility and thus improving Nafion film conductivity and sensor performance. The fabrication of ambient temperature oxygen microsensors includes depositing basic electrodes using noble metals, and metal oxides layer on one of the electrode as a reference electrode. The use of noble metals for electrodes is due to their strong catalytic properties for oxygen reduction. A conducting polymer Nafion, doped with water-retaining components and extra sites facilitating proton movement, was used as the electrolyte material, making the design adequate for low humidity environment applications. The Nafion solution was coated on the electrodes and air-dried. The sensor operates at room temperature in potentiometric mode, which measures voltage differences between working and reference electrodes in different gases. Repeat able responses to 21-percent oxygen in nitrogen were achieved using nitrogen as a baseline gas. Detection of oxygen from 7 to 21 percent has also been demonstrated. The room-temperature oxygen micro sensor developed has extremely low power consumption (no heating for operation, no voltage applied to the sensor, only a voltmeter is needed to measure the output), is small in size, is simple to batch-fabricate, and is high in sensor yield. It is applicable in a wide humidity range, with improved operation in low humidity after the additives were added to the Nafion film. Through further improvement and development, the sensor can be used for aerospace applications such as fuel leak detection, fire detection, and environmental monitoring.

Hunter, Gary W.↗