Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Waterproof stretchable optoelectronics

Described herein are flexible and stretchable LED arrays and methods utilizing flexible and stretchable LED arrays. Assembly of flexible LED arrays alongside flexible plasmonic crystals is useful for construction of fluid monitors, permitting sensitive detection of fluid refractive index and composition. Co-integration of flexible LED arrays with flexible photodetector arrays is useful for construction of flexible proximity sensors. Application of stretchable LED arrays onto flexible threads as light emitting sutures provides novel means for performing radiation therapy on wounds.

Rogers, John A.↗

A Cryogenic readout integrated circuit with analog pile-up and in-Pixel ADC for high frame rate Skipper CCD-in-CMOS Sensors

The Skipper CCD-in-CMOS Parallel Read-Out Circuit V2 (SPROCKET2) is designed to enable high frame rate readout of Skipper CCD-in-CMOS image sensors. The SPROCKET2 pixel is fabricated in a 65 nm CMOS process and occupies a 60$\mu$m $\times$ 60$\mu$m footprint. SPROCKET2 is intended to be heterogeneously integrated with a pixelated Skipper CCD-in-CMOS sensor, such that one readout pixel is connected to a multiplexed array of 16 active image sensor pixels, to match their spatial geometry. Our design benefits from the Skipper CCD-in-CMOS sensor's non-destructive readout capability to achieve exceptionally low noise through multi-sampling and averaging while optimizing for total power consumption. The pixel readout utilizes correlated double sampling to minimize 1/f noise and includes "pile-up" of ten successive samples in the analog domain before digitizing at a rate of 66.7 ksps. Measurement results of in-pixel serial SAR ADC show DNL and INL of ~0. 44 LSB and 0.58 LBS respectively. A large area array of 20,000 SPROCKET2 ADC pixels (multiplexed 1:16 to 320,000 sensor pixels) is currently under test. By reading out data over a 10 Gbps optical link, this pixel design enables a frame rate of $\sim$ 4 kfps for large sensing areas with minimal sensing deadtime. In the highest gain mode, the pixelated ADC has an input-referred resolution of 10$\mu$V with a simulated power consumption of 50$\mu$W. The pixel operates with constant current draw to minimize power-rail crosstalk.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proposal for gravitational direct detection of dark matter

The only coupling dark matter is guaranteed to have with the standard model is through gravity. Here we propose a concept for direct dark matter detection using only this gravitational coupling. We suggest that an array of quantum-limited mechanical impulse sensors may be capable of detecting the correlated gravitational force created by a passing dark matter particle. We consider the effects of irreducible noise from couplings of the sensors to the environment and noise due to the quantum measurement process. We show that the signal from Planck-scale dark matter is in principle detectable using a large number of gram-scale sensors in a meter-scale array with sufficiently low quantum noise, and discuss some experimental challenges en route to achieving this target.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methods for the robust computation of the long-period seismic spectrum of broad-band arrays

SUMMARY We describe array methods to search for low signal-to-noise ratio (SNR) signals in long-period seismic data using Fourier analysis. This is motivated by published results that find evidence of solar free oscillations in the Earth's seismic hum. Previous work used data from only one station. In this paper, we describe methods for computing spectra from array data. Arrays reduce noise level through averaging and provide redundancy that we use to distinguish coherent signal from a random background. We describe two algorithms for calculating a robust spectrum from seismic arrays, an algorithm that automatically removes impulsive transient signals from data, a jackknife method for estimating the variance of the spectrum, and a method for assessing the significance of an entire spectral band. We show examples of their application to data recorded by the Homestake Mine 3-D array in Lead, SD and the Piñon Flats PY array. These are two of the quietest small aperture arrays ever deployed in North America. The underground Homestake data has exceptionally low noise, and the borehole sensors of the PY array also have very low noise, making these arrays well suited to finding very weak signals. We find that our methods remove transient signals effectively from the data so that even low-SNR signals in the seismic background can be found and tested. Additionally, we find that the jackknife variance estimate is comparable to the noise floor, and we present initial evidence for solar g-modes in our data through the T2 test, a multivariate generalization of Student's t-test.

Caton, Ross C.↗

Development of CMOS Sensors for HEP with a US-based foundry

We will present a program to establish the first development and manufacturing of HEP-specific sensors monolithically integrated into a standard CMOS process using a US-based foundry. In collaboration with several US universities the project aims to develop Monolithic Active Pixel Sensors (MAPS) designs implemented in the 90 nm technology node, including simple test structures and multi-pixel arrays, and monolithic CMOS sensors with readout integrated circuits, perform detailed characterization of the detector prototypes and quantify their performance for HEP applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Back-Azimuth Estimation of Air-to-Ground Coupled Infrasound from Transverse Coherence Minimization

We present the transverse coherence minimization method (TCM)—an approach to estimate the back–azimuth of infrasound signals that are recorded on an infrasound microphone and a colocated three–component seismometer. Accurate back–azimuth information is important for a variety of monitoring efforts, but it is currently only available for infrasound arrays and for seismoacoustic sensor pairs separated by 10 s of meters. Our TCM method allows for the analysis of colocated sensor pairs, sensors located within a few meters of each other, which may extend the capabilities of existing seismoacoustic networks and supplement operating infrasound arrays. This approach minimizes the coherence of the transverse component of seismic displacement with the infrasound wave to estimate the infrasound back–azimuth. After developing an analytical model, we investigate seismoacoustic signals from the August 2012 Humming Roadrunner experiment and the 26 May 2021 eruption of Great Sitkin Volcano, Alaska, U.S.A., at the ranges of 6.5–185 km from the source. We discuss back–azimuth estimates and potential sources of deviation (1°–15°), such as local terrain effects or deviation from common analytical models. This practical method complements existing seismoacoustic tools and may be suitable for routine application to signals of interest.

58 GEOSCIENCES↗

A Vector Sensor-Based Acoustic Characterization System for Marine Renewable Energy

NoiseSpotter is a passive acoustic monitoring system that characterizes, classifies, and geo-locates anthropogenic and natural sounds in near real time. It was developed with the primary goal of supporting the evaluation of potential acoustic effects of offshore renewable energy projects. The system consists of a compact array of three acoustic vector sensors, which measures acoustic pressure and the three-dimensional particle velocity vector associated with the propagation of an acoustic wave, thereby inherently providing bearing information to an underwater source of sound. By utilizing an array of three vector sensors, the application of beamforming techniques can provide sound source localization, allowing for characterization of the acoustic signature of specific underwater acoustic sources. Here, performance characteristics of the system are presented, using data from controlled acoustic transmissions in a quiet environment and ambient noise measurements in an energetic tidal channel in the presence of non-acoustic flow noise. Data quality is demonstrated by the ability to reduce non-acoustic flow noise contamination, while system utility is shown by the ability to characterize and localize sources of sound in the underwater environment.

16 TIDAL AND WAVE POWER↗

Physics Considerations for a Harp System Design at the Second Target Station of the Spallation Neutron Source

A harp system is being developed for monitoring proton beam profile direct upstream of the proton beam window at the Second Target Station of the Spallation Neutron Source, Oak Ridge National Laboratory. It consists of two sensor planes which have arrays of thin conducting wires aligned vertically and horizontally, respectively. It monitors beam profiles in two transverse directions to the beam axis by measuring the net-charge depositions in the sensor wires, which are caused by ejection of secondary electrons and delta rays driven by electromagnetic interactions with high energy protons. The net charge deposition in a sensing wire linearly correlates with the number of incident protons on it. This correlation is perturbed when the wire interacts with secondary electrons and delta rays originating from beam matter interactions in neighboring wires, PBW and residual gases. In this paper, we analyze the physical phenomena that affects the measurement uncertainties of the harp using particle transport simulations.

Lee, Yong Joong [ORNL] (ORCID:0000000298381723)↗

WIRE-21 Sensor Irradiation Experiment Ready for HFIR Insertion

The ability to deploy new nuclear fuels for current or future reactor concepts requires a wealth of data regarding fuel performance during normal operation, anticipated operational occurrences, and design-basis accidents. Most of these data have historically been collected during experiments in materials test reactors, ideally with online instrumentation to collect as much data as possible. However, advanced instrumentation could also allow for in situ monitoring of fuel operating conditions during commercial reactor operation to maximize fuel utilization, reduce unnecessary conservativism in design margins, and improve operator understanding of limiting peaking factors. The latter approach would complicate fuel handling, particularly during refueling, unless the instrumentation could be placed inside the fuel rods and transmitted wirelessly to a receiver located outside the fuel’s primary pressure boundary. To this end, Westinghouse Electric Company (WEC) developed wireless sensors based on inductive coupling that can transmit information regarding fuel centerline temperatures and rod internal pressures wirelessly from within a fuel rod to a nearby instrument thimble. After testing these sensors in lower-power university research reactors, the next step is to perform high neutron fluence testing to characterize the performance of these wireless sensors under conditions that are more representative of the intended application—in this case, light-water reactors (LWRs). The removable Be (RB) positions of the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) provide the neutron flux, experiment volume, and access to instrument leads required to achieve these sensor testing goals. This report summarizes the design, analysis, and assembly of the Wireless Instrumented RB Experiment 2021 (WIRE-21). This is the most highly instrumented irradiation experiment ever performed in HFIR. The experiment will use seven different sensing techniques to measure temperature, pressure, neutron flux, and neutron fluence during reactor operation. In addition to WEC’s wireless temperature and pressure sensors, WIRE-21 includes an array of thermocouples, self-powered neutron detectors, spatially distributed fiber optic temperature sensors, passive SiC temperature monitors, and flux wires. The design of WIRE-21 and the cabling that was installed in HFIR also provide the infrastructure to enable accelerated, economical testing of advanced sensor technologies while leveraging the extremely high neutron flux that is available in HFIR. The containment for WIRE-21 is similar to previous RB irradiation vehicles but includes a few modifications, most notably the use of integrated compression seals to pass a larger number of sensor leads through the experiment’s pressure boundary. In addition to the sensor leads, inert gas lines are passed into the experiment to enable active temperature control and the ability to pneumatically actuate a bellows-driven pressure sensor. WIRE-21 is targeting component temperatures (300–350°C) and neutron fluence levels (~10 22 n/cm 2 ) that would be expected in the plenum region of LWR fuels, except for the active sensing region of the wireless temperature sensor, which is targeting LWR fuel centerline temperatures (~800–1,100°C). WIRE-21 was successfully assembled, passed all nondestructive examination, and was delivered to HFIR for insertion during upcoming cycle 498 (April 2022).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design and calibration of an optically segmented single volume scatter camera for neutron imaging

The Optically Segmented Single Volume Scatter Camera (OS-SVSC) aims to image neutron sources for non-proliferation applications using the kinematic reconstruction of elastic double-scatter events. Our prototype system consists of 64 EJ-204 organic plastic scintillator bars, each measuring 5mm × 5mm × 200mm and individually wrapped in Teflon tape. The scintillator array is optically coupled to two silicon photomultiplier ArrayJ-60035 64P-PCB arrays, each comprised of 64 individual 6x6mm J-Series sensors arranged in an 8 × 8 array. We report on the design details, including component selections, mechanical design and assembly, and the electronics system. The described design leveraged existing off-the-shelf solutions to support the rapid development of a phase 1 prototype. Several valuable lessons were learned from component and system testing, including those related to the detector's mechanical structure and electrical crosstalk that we conclude originates in the commercial photodetector arrays and the associated custom breakout cards. We detail our calibration efforts, beginning with calibrations for the electronics, based on the IRS3D application-specific integrated circuits, and their associated timing resolutions, ranging from 3090ps. With electronics calibrations applied, energy and position calibrations were performed for a set of edge bars using 22 Na and 90 Sr, respectively, reporting an average resolution of 12.07±0.03mm for energy depositions between 900keVee and 1000keVee. We further demonstrate a position calibration method for the internal bars of the matrix using cosmic-ray muons as an alternative to emission sources that cannot easily access these bars, with an average measured resolution of 14.86+-0.29mm for depositions between 900keVee and 1000keVee. The coincident time resolution reported between pairs of bars measured up to 400ps from muon acquisitions. Energy and position calibration values measured with muons are consistent with those obtained using particle emission sources.

47 OTHER INSTRUMENTATION↗

Hyperspectral X-ray Imaging: Progress Towards Chemical Analysis in the SEM

The Hyperspectral X-ray Imaging (HXI) project will enable non-destructive chemical-state determination of nano-scale samples in the electron microscope for nuclear safeguards applications. To efficiently measure chemical state through electron-excited X-ray emission requires a combination of wide spectral bandwidth, high resolution, and high count rate capability. We are building a next-generation X-ray detector based on an array of transition edge sensors (TESs) to make these measurements possible and routine in the scanning electron microscope (SEM). Leveraging the large pixel densities afforded by microwave multiplexing readout and continuous, uninterrupted operation of a cryogen-free dilution refrigerator, this instrument will have efficiency to allow chemical species identification of nano-scale samples in hours instead of days to weeks. We describe prototype pixel designs for this HXI instrument, comprising three pixel types that will make up the hybrid TES array. Engineering design of the integrated HXI cryostat and SEM system is in progress, with full detector commissioning expected in Spring 2021 followed closely by full-scale integration with the SEM. Furthermore, we also report on the commissioning of a complementary TES-based X-ray emission spectroscopy platform for bulk samples to build a spectral library for HXI sample identification.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterizing electron-collecting CdTe for use in a 77 ns burst-rate imager

The Keck-PAD (pixel array detector) was developed at Cornell as a burst-rate imager capable of recording images from successive electron bunches (153 ns period) from the Advanced Photon Source (APS). Both Si and hole-collecting Schottky CdTe have been successfully bonded to this ASIC (application-specific integrated circuit) and used with this frame rate. The facility upgrades at the APS will lower the bunch period to 77 ns, which will require modifications to the Keck-PAD electronics to image properly at this reduced period. In addition, operation at high X-ray energies will require a different sensor material having a shorter charge collection time. For the target energy of 40 keV for this project, simulations have shown that electron-collecting CdTe should allow >90% charge collection within 35 ns. This collection time will be sufficient to sample the signal from one frame and prepare for the next. 750 µm-thick electron-collecting Schottky CdTe has been obtained from Acrorad and bonded to two different charge-integrating ASICs developed at Cornell, the Keck-PAD and the CU-APS-PAD. Carrier mobility has been investigated using the detector response to single X-ray bunches at the Cornell High Energy Synchrotron Source and to a pulsed optical laser. The tests indicate that the collection time will meet the requirements for 77 ns imaging.

36 MATERIALS SCIENCE↗

Multi‐Sensor Trajectory Reconstruction of the 24 April 2025 Alaska Fireball and Implications for Planetary Defense

On 24 April 2025 at 18:30:57 UTC, a bright daytime fireball over Southcentral Alaska was detected by 37 seismic stations, 16 single infrasound sensors, and four infrasound arrays, yielding 30 ballistic and multiple fragmentation arrivals. Here, the unprecedented density of seismoacoustic coverage enabled detailed reconstruction of the event using acoustic signals, with fragmentation source locations further guiding the identification of Doppler weather radar signatures of a meteorite fall. Incorporation of a radar-derived terminal point yielded a final trajectory solution, which agreed closely with an independent optical trajectory solution from video analysis. The reconstructed entry parameters from seismoacoustic analysis indicate a velocity of 25.3 km/s, an entry angle of 19°, and an energy release of ∼38 t TNT equivalent. Assuming a chondritic composition, the pre-entry object diameter was ∼0.7 m. Using orbital parameters from the optical solution, we estimate meteoroid composition as most likely an L-type ordinary chondrite. The event occurred in the sub-Arctic, where space-based optical systems face challenges in detection, demonstrating the critical role of dense ground-based seismoacoustic networks in characterizing high-latitude atmospheric entries. This uniquely well-recorded event demonstrates the capability of dense seismoacoustic networks to constrain bolide trajectories, energetics, and fragmentation, with radar and optical data providing critical confirmation and complementary perspectives. These results bridge the methodological gap between planetary-defense monitoring of natural impactors and space-traffic analyses of artificial reentries, illustrating how multi-sensor integration can deliver calibration-grade trajectories even for unpredicted events.

Fireball↗

Vector sensor-based acoustic monitoring system

An acoustic monitoring system characterizes, classifies, and geo-locates anthropogenic and natural sounds in near real time. The system includes a compact array of three acoustic vector sensors, which measures acoustic pressure and the three-dimensional particle velocity vector associated with the propagation of an acoustic wave, thereby inherently providing bearing information to an underwater source of sound. Beamforming techniques provide sound source localization, allowing for characterization of the acoustic signature of specific underwater acoustic sources.

Raghukumar, Kaustubha↗

Chip-integrated metasurface full-Stokes polarimetric imaging sensor

Abstract Polarimetric imaging has a wide range of applications for uncovering features invisible to human eyes and conventional imaging sensors. Chip-integrated, fast, cost-effective, and accurate full-Stokes polarimetric imaging sensors are highly desirable in many applications, which, however, remain elusive due to fundamental material limitations. Here we present a chip-integrated Meta surface-based Full-Stokes Polar imetric Im aging sensor (MetaPolarIm) realized by integrating an ultrathin (~600 nm) metasurface polarization filter array (MPFA) onto a visible imaging sensor with CMOS compatible fabrication processes. The MPFA is featured with broadband dielectric-metal hybrid chiral metasurfaces and double-layer nanograting polarizers. This chip-integrated polarimetric imaging sensor enables single-shot full-Stokes imaging (speed limited by the CMOS imager) with the most compact form factor, records high measurement accuracy, dual-color operation (green and red) and a field of view up to 40 degrees. MetaPolarIm holds great promise to enable transformative applications in autonomous vision, industry inspection, space exploration, medical imaging and diagnosis.

47 OTHER INSTRUMENTATION↗

Nanoconfinement and mass transport in metal–organic frameworks

The ubiquity of metal–organic frameworks in recent scientific literature underscores their highly versatile nature. MOFs have been developed for use in a wide array of applications, including: sensors, catalysis, separations, drug delivery, and electrochemical processes. Often overlooked in the discussion of MOF-based materials is the mass transport of guest molecules within the pores and channels. Given the wide distribution of pore sizes, linker functionalization, and crystal sizes, molecular diffusion within MOFs can be highly dependent on the MOF-guest system. In this paper, we discuss the major factors that govern the mass transport of molecules through MOFs at both the intracrystalline and intercrystalline scale; provide an overview of the experimental and computational methods used to measure guest diffusivity within MOFs; and highlight the relevance of mass transfer in the applications of MOFs in electrochemical systems, separations, and heterogeneous catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis and mitigation of an oscillating background on hybrid complementary metal-oxide semiconductor (hCMOS) imaging sensors at the National Ignition Facility

Nanosecond-gated hybrid complementary metal-oxide semiconductor imaging sensors are a powerful tool for temporally gated and spatially resolved measurements in high energy density science, including inertial confinement fusion, and in laser diagnostics. However, a significant oscillating background excited by photocurrent has been observed in image sequences during testing and in experiments at the National Ignition Facility (NIF). Characterization measurements and simulation results are used to explain the oscillations as the convolution of the pixel-level sensor response with a sensor-wide RLC circuit ringing. Finally, data correction techniques are discussed for NIF diagnostics, and for diagnostics where these techniques cannot be used, a proof-of-principle image correction algorithm is presented.

42 ENGINEERING↗