Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scan report”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Chemical Composition Analysis for X-Ray Transport Container Scans

It is important for national security to control the movement of dangerous or strategically cargo such as explosives, radioactive materials, rare and precious metals. This control can be provided by scanning transport containers by gamma rays. In this report the existing technique for scanning (dual energy method) is considered and the alternative method based on measuring the energy distribution of gamma rays is proposed. For estimation perspectives of the proposing method, the corresponding simulation was conducted by using the GEANT4 toolkit. The example of the algorithm of reconstruction the chemical composition of the scanned object is also considered. In addition the experiment for estimation energy resolution of the detector based on a scintillation crystal BGO and SiPM was carried out.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and Clinical Implementation of a Universal Bolus to Maintain Spot Size During Delivery of Base of Skull Pencil Beam Scanning Proton Therapy

Purpose: To report on a universal bolus (UB) designed to replace the range shifter (RS); the UB allows the treatment of shallow tumors while keeping the pencil beam scanning (PBS) spot size small. Methods and Materials: Ten patients with brain cancers treated from 2010 to 2011 were planned using the PBS technique with bolus and the RS. In-air spot sizes of the pencil beam were measured and compared for 4 conditions (open field, with RS, and with UB at 2- and 8-cm air gap) in isocentric geometry. The UB was applied in our clinic to treat brain tumors, and the plans with UB were compared with the plans with RS. Results: A UB of 5.5 cm water equivalent thickness was found to meet the needs of the majority of patients. By using the UB, the PBS spot sizes are similar with the open beam (P>.1). The heterogeneity index was found to be approximately 10% lower for the UB plans than for the RS plans. The coverage for plans with UB is more conformal than for plans with RS; the largest increase in sparing is usually for peripheral organs at risk. Conclusions: The integrity of the physical properties of the PBS beam can be maintained using a UB that allows for highly conformal PBS treatment design, even in a simple geometry of the fixed beam line when noncoplanar beams are used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inaugural Technologist in Communities Scanning Tour: Automated and Electrified On-Demand Mobility (Follow-On Summary Report: April 24-25, 2023) [Slides]

In 2023, the Technologist in Communities (TIC) program hosted its inaugural scanning tour across the American Southwest, with a goal of investigating the region's leading public mobility systems and their integration with on-demand public mobility services. The scanning tour concept was inspired by and named after a U.S. Department of Transportation Federal Highway Administration practice of hosting "scanning tours," both domestically and abroad, to explore innovative transportation practices throughout the 1990s and early 2000s. Guided by the idea that "seeing is believing," scanning tours created opportunities for government and industry representatives to collectively experience new technologies and best practices firsthand. In 2023, the National Renewable Energy Laboratory (NREL) followed suit by leading the inaugural TIC scanning tour. TIC, part of the Technology Integration program within the U.S. Department of Energy's (DOE's) Vehicle Technologies Office, supports positive energy and mobility outcomes in communities across rural to urban contexts. TIC enables technical experts to work directly with leaders and stakeholders in communities and assist them in implementing promising new technologies. This first TIC scanning tour invited NREL, DOE, and industry experts to survey innovative public mobility practices and their integration into public transit systems across the Southwest. The tour's goals included examining the state of innovation in public mobility in cities, communities, and airports; facilitating collaboration between entities; and sparking potential new partnerships. The following report summarizes key findings from the scanning tour.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wavefront distortion correction in scanning tunneling microscope image

Here, we report an algorithm to identify and correct distorted wavefronts in atomic resolution scanning tunneling microscope images. This algorithm can be used to correct nonlinear in-plane distortions without prior knowledge of the physical scanning parameters, the characteristics of the piezoelectric actuator, or individual atom positions. The 2D image is first defined as a sum of sinusoidal plane waves, where a nonlinear distortion renders a curve for an otherwise ideal linear wavefront. Using the Fourier transforms of local areas of the image, the algorithm generates a wavefront vector field. The identified wavefronts are subsequently linearized for each plane wave without changing lattice orders, giving rise to distortion corrections. Our algorithm is complementary to conventional post-processing algorithms that require prior detection of real space features, which can also be used to correct nonlinear distortions in 2D images acquired by other microscopy techniques.

47 OTHER INSTRUMENTATION↗

Prevalence and variability in reporting of clinically actionable incidental findings on attenuation-correction CT scans in a veteran population

Background: Myocardial perfusion imaging (MPI) often employs attenuation-correction computed tomography (CTAC) to reduce attenuation artifacts and improve specificity. While there is no specific guideline on how they should be reported, incidental noncardiac findings identified on these scans may be clinically significant. The prevalence of these findings in veterans is not currently known. In addition, variability in reporting these findings may depend on the interpreting physician’s specialty. Methods: To guide future decision-making, CTACs in veterans referred for MPI were prospectively evaluated in a quality-control project for a set of prespecified actionable incidental findings by cardiologists and a radiologist. Results: On the 771 scans performed over eight months, 285 incidental noncardiac findings were identified by the interpreting cardiologists and 378 were identified by the interpreting radiologist. Pulmonary nodules were the most common occurring in 20% of studies read by the radiologist. Interreader agreements between cardiologists and the radiologist were poor for pulmonary nodules ≥ 10 mm and hiatal hernias; fair for pulmonary nodules < 10 mm, extracardiac masses, and aortic aneurysms; and moderate for pleural plaques. Conclusion: Incidental noncardiac findings on CTACs are common in our veteran population. Overall interobserver agreement in identifying these findings between cardiologists and radiologists is fair. Specific guidelines are needed on how CTACs should be read and reported.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A protocol for EBT3 radiochromic film dosimetry using reflection scanning

Purpose: To evaluate the performance of the EBT3 radiochromic film dosimetry system using reflection measurements and to suggest a calibration protocol for precise and accurate reflection film dosimetry. Methods: A set of 14 Gafchromic EBT3 film pieces were irradiated to various doses ranging from 0 to 8 Gy and subsequently scanned using both the reflection and transmission mode. Scanning resolution varied from 50 to 508 dpi (0.5–0.05 mm/pixel). Both the red and green color channels of scanned images were used to relate the film response to the dose. A sensitivity, uncertainty, and accuracy analysis was performed for all scanning modes and color channels. The total uncertainty, along with the fitting and experimental uncertainty components, was identified and analyzed. A microscope resolution target was used to evaluate possible resolution losses under reflection scanning. The calibration range was optimized for reflection scanning in the low (<2 Gy) and high (>2 Gy) dose regions based on the reported results. Results: Reflection scanning using the red channel exhibited the highest sensitivity among all modes, being up to 150% higher than transmission mode in the red channel for the lowest dose level. Furthermore, there was no apparent loss in resolution between the two modes. However, higher uncertainties and reduced accuracy were observed for the red channel under reflection mode, especially at dose levels higher than 2 Gy. These uncertainties were mainly attributed to saturation effects which were translated in poor fitting results. By restricting the calibration to the 0–2 Gy dose range, the situation is reversed and the red reflection mode was superior to the transmission mode. For higher doses, the green channel in reflection mode presented comparable results to the red transmission. Conclusions: A two-color reflection scanning protocol can be suggested for EBT3 radiochromic film dosimetry using the red channel for doses less than 2 Gy and the green channel for higher doses. The precision and accuracy are significantly improved in the low dose region following such a protocol.

60 APPLIED LIFE SCIENCES↗

Computed Tomography Scanning and Geophysical Measurements of the Salina Formation from the #36 Brine Well

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize core of the Salina Formation from a vertical well (Brine Well #36) from Marshall County, West Virginia at a depth of 6,555.6 to 6,719.5 ft. The primary impetus of this work is a collaboration between West Virginia Geological and Economic Survey (WVGES) and NETL to characterize core from multiple wells to better understand the key formations in West Virginia. As part of this effort, bulk scans of core were obtained from the Brine Well #36, provided by the WVGES. This report, and the associated scans generated, provide detailed datasets not typically available for researchers to analyze.

58 GEOSCIENCES↗

Highlights from 4STAR Sky-Scanning Retrievals of Aerosol Intensive Optical Properties from Multiple Field Campaigns with Detailed Comparisons of SSA Reported During SEAC4RS

The 4STAR (Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research) instrument combines airborne sun tracking capabilities of the Ames Airborne Tracking Sun Photometer (AATS-14) with AERONET (Aerosol Robotic Network)-like sky-scanning capability and adds state-of-the-art fiber-coupled grating spectrometry to yield hyperspectral measurements of direct solar irradiance and angularly resolved sky radiance. The combination of sun-tracking and sky-scanning capability enables retrievals of wavelength-dependent aerosol optical depth (AOD), mode-resolved aerosol size distribution (SD), asphericity, and complex refractive index, and thus also the scattering phase function, asymmetry parameter, single-scattering albedo (SSA), and absorption aerosol optical thickness (AAOT). From 2012 to 2014 4STAR participated in four major field campaigns: the U.S. Dept. of Energy's TCAP (Two-Column Aerosol Project) I & II campaigns, and NASA's SEAC4RS (Studies of Emissions, Atmospheric Composition, Clouds and Climate Coupling by Regional Surveys) and ARISE (Arctic Radiation - IceBridge Sea & Ice Experiment) campaigns. Establishing a strong performance record, 4STAR operated successfully on all flights conducted during each of these campaigns. Sky radiance spectra from scans in either constant azimuth (principal plane) or constant zenith angle (almucantar) were interspersed with direct beam measurements during level legs. During SEAC4RS and ARISE, 4STAR airborne measurements were augmented with flight-level albedo from the collocated Shortwave Spectral Flux Radiometer (SSFR) providing improved specification of below-aircraft radiative conditions for the retrieval. Calibrated radiances and retrieved products will be presented with particular emphasis on detailed comparisons of ambient SSA retrievals and measurements during SEAC4RS from 4STAR, AERONET, HSRL2 (High Spectral Resolution Lidar), and from in situ measurements.

Radiance↗

4STAR Sky-Scanning Retrievals of Aerosol Intensive Optical Properties from Multiple Field Campaigns with Detailed Comparisons of SSA Reported During SEAC4RS

The 4STAR (Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research) instrument combines airborne sun tracking capabilities of the Ames Airborne Tracking Sun Photometer (AATS-14) with AERONET-like sky-scanning capability and adds state-of-the-art fiber-coupled grating spectrometry to yield hyper spectral measurements of direct solar irradiance and angularly resolved sky radiance. The combination of sun-tracking and sky-scanning capability enables retrievals of wavelength-dependent aerosol optical depth (AOD), mode-resolved aerosol size distribution (SD), asphericity, and complex refractive index, and thus also the scattering phase function, asymmetry parameter, single-scattering albedo (SSA), and absorption aerosol optical thickness (AAOT).From 2012 to 2014 4STAR participated in four major field campaigns: the U.S. Dept. of Energy TCAP I II campaigns, and NASAs SEAC4RS and ARISE campaigns. Establishing a strong performance record, 4STAR operated successfully on all flights conducted during each of these campaigns. Sky radiance spectra from scans in either constant azimuth (principal plane) or constant zenith angle (almucantar) were interspersed with direct beam measurements during level legs. During SEAC4RS and ARISE, 4STAR airborne measurements were augmented with flight-level albedo from the collocated Shortwave Spectral Flux Radiometer (SSFR) providing improved specification of below-aircraft radiative conditions for the retrieval. Calibrated radiances and retrieved products will be presented with particular emphasis on detailed comparisons of ambient SSA retrievals and measurements during SEAC4RS from 4STAR, AERONET, HSRL2, and from in situ measurements.

Flynn, Connor↗

Lessons learned on the presentation of scan data

Technicians performed a radiological survey of a surplus metal tank to support disposition planning at an Oak Ridge, Tennessee site. The survey included radiation scans to identify contamination and, if identified, define the boundary and magnitude of contamination. Fixed-point 1-minute measurements were also collected at randomly selected locations for comparison against the site's free release limit of 5,000 disintegrations per minute per 100 cm² (dpm/100 cm²) (0.83 Bq/cm²). Scan data were recorded using a data logger as a means to document surveyor observation - logged data captured at 1-second intervals and converted to counts per minute (cpm) by the data logger software were presented in the project report. Both the qualitative scan data (in cpm) and the quantitative direct measurement (in dpm/100 cm²) were reported for completeness, so stakeholders had all available information to support disposition decisions. However, a new stakeholder - introduced to the project at the reporting phase of work - used the instrument efficiency and background data to convert the scan data from cpm to dpm/100 cm², then compared the converted results to the site limit. Many of the converted values exceeded 5,000 dpm/100 cm². This resulted in delays in tank disposition and additional project costs which could have been avoided if the proper use and interpretation of scan data, and implications of radon progeny buildup on oxidized metal surfaces, had been better communicated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Computed Tomography Scanning and Geophysical Measurements of Core from the Coldstream 1MH Well

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) Morgantown, West Virginia site were used to characterize core of the Marcellus Shale from a vertical well, the Coldstream 1MH Well in Clearfield County, PA. The core is comprised primarily of the Marcellus Shale from a depth of 7,002 to 7,176 ft. The primary impetus of this work is a collaboration between West Virginia University (WVU) and NETL to characterize core from multiple wells to better understand the structure and variation of the Marcellus and Utica shale formations. As part of this effort, bulk scans of core were obtained from the Coldstream 1MH well, provided by the Energy Corporation of America (now Greylock Energy). This report, and the associated scans, provide detailed datasets not typically available from unconventional shales for analysis. The resultant datasets are presented in this report, and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/coldstream-1mh-well. All equipment and techniques used were non-destructive, enabling future examinations to be performed on these cores. None of the equipment used was suitable for direct visualization of the shale pore space, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with x-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis as well as fractured zones. En echelon fractures were observed at 7,100 ft and were CT scanned using NETL’s industrial CT scanner at higher resolution. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provided a multi-scale analysis of this core and provides both a macro and micro description of the core that is relevant for many subsurface energy-related examinations that have traditionally been performed at NETL.

03 NATURAL GAS↗

Final report: Mapping Interactions in Hybrid Systems with Active Scanning Probes

This project aimed to study and map interactions between components of hybrid nanodevices using a novel scanning probe approach. To enable this work, we initially constructed a flexible experimental apparatus allowing for simultaneous scanning probe and confocal optical microscopy measurements. This setup was first used for all-optical measurements of nanostructures, with the focus then shifting to hybrid devices in which single coherent electron spins are coupled to micron-scale ferromagnetic elements, which may prove useful for addressing single spins, enhanced sensing, or spin-wave-mediated coupling of spins for quantum information applications. A significant breakthrough was the realization that it is not necessary to fabricate a magnetic structure on a scanning probe – instead a ferromagnetic vortex core can act as an integrated, solid state, scanning probe. The core of the vortex produces a very strong, localized fringe field which can be used analogously to an MFM tip. Unlike a traditional MFM tip, however, the vortex core is scanned within an integrated device (eliminating drift), and can be moved on vastly faster timescales. This approach allows the detailed investigation of interactions between single spins and complex driven ferromagnetic dynamics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Measurement of fifth- and sixth-order fluctuations of (net-)proton number in Au + Au collisions from phase II of the beam energy scan program at RHIC

We report high-statistics measurements of fifth- and sixth-order factorial cumulants and cumulant ratios of (net-)proton multiplicity distributions in Au+Au collisions at $\sqrt{s_{NN}}$ = 7.7–27GeV, using data from the STAR experiment collected during the Beam Energy Scan Phase II at RHIC. Protons and antiprotons are identified at midrapidity (|𝑦| < 0.5) with transverse momentum 0.4 < 𝑝 𝑇 < 2.0GeV/𝑐. The proton factorial cumulants 𝜅 4 , 𝜅 5 , and 𝜅 6 increase with order but exhibit no sign alternation within current uncertainties, offering no evidence for a two-component structure in the proton multiplicity distribution, as might be expected near a first-order phase transition. The cumulant ratios 𝐶 5 /𝐶 1 and 𝐶 6 /𝐶 2 fluctuate around zero in collisions at 0–40% centrality. The results are consistent with both the negative predictions from lattice QCD and the positive trends obtained from the ultrarelativistic quantum molecular dynamics (UrQMD) model. At $\sqrt{s_{NN}}$ ≳ 27GeV, the 𝐶 4 /𝐶 2 and 𝐶 5 /𝐶 1 results are compatible with predictions from lattice QCD, functional renormalization group (FRG), and hadron resonance gas (HRG) models, while UrQMD describes the data better at lower energies. Here, these measurements place constraints on baryon number fluctuations and offer valuable insights into the QCD phase structure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-562: Scanned Percent Depth Dose Curve Discrepancy for Photon Beams with Physical Wedge in Place (Varian IX) Using Different Sensitive Volume Ion Chambers

Purpose: To investigate and report the discrepancy of scanned percent depth dose (PDD) for photon beams with physical wedge in place when using ion chambers with different sensitive volumes. Methods/Materials: PDD curves of open fields and physical wedged fields (15, 30, 45, and 60 degree wedge) were scanned for photon beams (6MV and 10MV, Varian iX) with field size of 5x5 and 10x10 cm using three common scanning chambers with different sensitive volumes - PTW30013 (0.6cm3), PTW23323 (0.1cm3) and Exradin A16 (0.007cm3). The scanning system software used was OmniPro version 6.2, and the scanning water tank was the Scanditronix Wellhoffer RFA 300.The PDD curves from the three chambers were compared. Results: Scanned PDD curves of the same energy beams for open fields were almost identical between three chambers, but the wedged fields showed non-trivial differences. The largest differences were observed between chamber PTW30013 and Exradin A16. The differences increased as physical wedge angle increased. The differences also increased with depth, and were more pronounced for 6MV beam. Similar patterns were shown for both 5x5 and 10x10 cm field sizes. For open fields, all PDD values agreed with each other within 1% at 10cm depth and within 1.62% at 20 cm depth. For wedged fields, the difference of PDD values between PTW30013 and A16 reached 4.09% at 10cm depth, and 5.97% at 20 cm depth for 6MV with 60 degree physical wedge. Conclusion: We observed a significant difference in scanned PDD curves of photon beams with physical wedge in place obtained when using different sensitive volume ion chambers. The PDD curves scanned with the smallest sensitive volume ion chamber showed significant difference from larger chamber results, beyond 10cm depth. We believe this to be caused by varying response to beam hardening by the wedges.

07 ISOTOPE AND RADIATION SOURCES↗

Direct imaging of light elements by annular dark-field aberration-corrected scanning transmission electron microscopy

In this report, we show that an annular dark-field detector in an aberration-corrected scanning transmission electron microscope allows the direct observation of light element columns in crystalline lattices. At specific imaging conditions, an enhancement of the intensities of light element columns in the presence of heavy element columns is observed. Experimental results are presented for imaging the nitrogen and carbon atomic columns at the GaN-SiC interface and within the GaN and SiC compounds. The crystal polarity of GaN at the interface is identified. The obtained findings are discussed and are well supported by image simulations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optimal experimental design for the detection of light atoms from high-resolution scanning transmission electron microscopy images

We report an innovative method to explore the optimal experimental settings to detect light atoms from scanning transmission electron microscopy (STEM) images. Since light elements play a key role in many technologically important materials, such as lithium-battery devices or hydrogen storage applications, much effort has been made to optimize the STEM technique in order to detect light elements. Therefore, classical performance criteria, such as contrast or signal-to-noise ratio, are often discussed hereby aiming at improvements of the direct visual interpretability. However, when images are interpreted quantitatively, one needs an alternative criterion, which we derive based on statistical detection theory. Using realistic simulations of technologically important materials, we demonstrate the benefits of the proposed method and compare the results with existing approaches.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗