Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sampler”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Culture-Independent Microbial Air Profiling using a Spaceflight-Compatible Nanopore Sequencing Method

Microbial monitoring of spacecraft air is critical toward assessing the efficacy of microbial controls within the environmental control and life support systems to protect the crew and vehicle environment. Currently, onboard the International Space Station (ISS), the air is monitored every quarter using an impaction air sampler. With this method, microbial cells and spores are pulled onto plates containing a growth medium. Following onboard incubation, the crew reports approximate microbial levels to the ground, but sample return is required for identification. Upon return of the plates, the isolates present are identified for crew health risk assessments. As NASA moves beyond low-Earth orbit, sample return will be impractical, and a near real-time monitoring capability is essential. Significant strides have been made in recent years to utilize a molecular-based method for microbial profiling of ISS surfaces. The developed method is independent of microbial culture, thus removing the bias toward detecting only culturable organisms, eliminating the need for sample return, and reducing the risk to crew health from exposure to high microbial levels. The work described here details the evaluation of three different air sampling platforms whose product is amenable to downstream molecular processing. The three samplers were compared in terms of mass and power requirements, ease of use, and the resulting data. For the two highest-ranking samplers, a basic concept of operations was developed to transfer the sample into the already established preparation and sequencing process. Using these concepts of operations, an in-depth comparison of the molecular data generated was compared to the historical culture-based method. Data from both methods detailed similar microbial profiles, while the molecular method detailed microbial identifications that were lacking from the culture data. The developed method will enable the generation of near real-time microbial profiles of the spacecraft atmosphere.

Brandon Dunbar↗

Does Collection Time Bias the Ecology of Cleanroom Air Samples?

Microbial monitoring of astromaterials collections has taken on increased importance with the return of biologically sensitive samples from the asteroids Ryugu and Bennu and the initiation of the Mars Sample Return Program. Terrestrial bacteria and fungi can alter the mineralogy and organic composition of our collections causing irreversible contamination of pristine samples and increasing the risk of false positives for life detection measurements. NASA has conducted routine microbial monitoring of its existing collections since 20181. Initial monitoring focused on surface samples collected with foam swabs. Although, airborne microbiology is often decoupled from surface microbiology in the built environment2 culture-based air sampling techniques like impactors were not compliant with existing contamination control requirements. Bringing organic rich media, gelatin or liquids into curation cleanrooms presents an unacceptable risk to pristine samples. In 2022 NASA purchased a materials complaint air sampler and began collecting air samples from the cleanrooms in addition to surface samples3. The new instrument uses an electret filter to collect samples that are suitable for cultivating organisms or for direct DNA sequencing. Preliminary DNA sequencing results appeared to indicate that longer sampling times biased the microbial community in favor of hearty, spore-forming bacteria3. We present the results of a study comparing overnight sampling (17 hours) to short (1 hour) sampling of unoccupied curation cleanrooms. The results will help us optimize our monitoring protocols and develop a more detailed inventory of the ecology of astromaterials curation cleanrooms. Methods: We analyzed 72 paired air samples from six different cleanrooms including the meteorite processing lab (ISO 7 equivalent, 16 samples), the lunar lab (ISO 6 equivalent, 10 samples), the stardust lab (ISO 5 equivalent 14 samples), the OSIRIS-REx lab (ISO 5 equivalent, 12 samples), the Hayabusa2 lab (ISO 5 equivalent, 14 samples), and the Genesis lab (ISO 4 equivalent, 6 samples). All the samples were collected with an InnovaPrep Bobcat air sampler operating at a sampling rate of 200 L/min. The sampler operates for 5 minutes out of every 20 minute period. Half of the samples were collected by filtering 3,000L (15 min. of active sampling) of air across an electret filter for one hour. The rest of the samples were collected by filtering approximately 51,000 L air across the filter overnight (~17 hours, 255 min. of active sampling). Cells were eluted from the filter using 6-7 ml of pressurized 0.15% tween 20 in PBS (phosphate buffered saline). This liquid was used to cultivate bacteria according to previously published methods1,4,5 and for DNA extraction and next generation sequencing. DNA was extracted with a Qiagen MagAttract PowerMicrobiome kit6. To identify bacteria and archaea, the 16S rRNA gene was amplified using Earth Microbiome primers for the V4 region 7. The amplified DNA was sequenced on an Illumina MiSeq using a V3 reagent kit. The resulting sequences were processed using DADA2 and QIIME2 as implemented on the EDGE bioinformatics platform8–10. Results: Only two of the 72 samples had no amplifiable DNA. Amplified DNA concentrations ranged from 2.67 – 0.272 ng/µl. The median concentration of amplified DNA for the 1 hour samples was 0.770 ± 0.368 ng/µl. The median concentration of amplified DNA for the overnight samples was 0.877 ± 0.434 ng/µl. On average the overnight samples had slightly more sequences (58,960 vs. 59,456) and ASV’s (amplicon sequence variants) (60 vs 64.5) than the one hour samples, but these differences are not statistically significant. The most abundant ASV in every sample mapped to the genus Cupravidus. ASV’s mapping to the genuses Bacillus, Schlegelella, Thermus, and Staphylococcus were also common. Discussion and Future Work: Alpha diversity statistics like Shannon Entropy and Faith Phylogenetic Diversity are used to describe the diversity of organisms in a single sample. If a longer sampling time was biasing the data, we would expect to see a change in these diversity statistics vs. sample time. However, we did not observe this in our data. The median Shannon entropy was slightly higher for the overnight samples (3.773 vs 3.611) as was the Faith Phylogenetic Diversity (4.042 vs 3.596), but both values were within a standard deviation of each other for the two sampling times (Fig. 1). It is unlikely, that the longer sampling time is introducing bias into our data. We do observe a significant decrease in diversity when comparing the air samples by lab. The Genesis lab (ISO 4 equivalent) has a lower median number of ASV’s (45.5) than the other labs (62). Median values for Shannon Entropy (3.717 vs. 3.430) and Faith Phylogenetic Diversity (3.796 vs. 3.548) are also lower for Genesis, but those values are with one standard deviation of each other for the different sampling times. This is consistent with previous culture-based results suggesting that the environment in cleanrooms tends to select for a core group of organisms capable of surviving under dry, low nutrient, conditions. The presence of the ASV’s mapping to Cupravidus and Thermus in our sequencing blanks and controls suggests that several of the most common organisms in our samples represent contaminants from the reagents used to perform the DNA extractions and sequencing. Further work is needed to identify these contaminants, remove them from our data and recalculate the diversity statistics. This is a systematic error. Therefore, we do not expect removing the sequencing contaminants to change our conclusions. Longer air sample collection times appear to result in slightly higher diversity and do not bias the results towards “hardy” bacteria like spore-formers. Based on these preliminary results we conclude that sampling at least 3,000 liters of air is sufficient to capture the microbial diversity of cleanrooms, and that air samples can also be collected overnight without negatively impacting diversity. These results allow us to be flexible when designing microbial monitoring plans so that they do not interfere with routine lab activity. References: 1. Regberg, A. B. et al. 49th Lunar and Planetary Science Conference (2018). 2. The United States Pharmacopeial Convention. USP General Chapter <1116> (2013). 3. Regberg, A. B., et al. 54th Lunar and Planetary Science Conference (2023). 4. Regberg, A. B. et al. 53rd Lunar and Planetary Science Conference ( 2022). 5. Davis, R. E.,et al. 50th Lunar and Planetary Science Conference (2019). 6. Qiagen. MagAttract® PowerMicrobiome® DNA/RNA EP Kit Handbook. (2018). 7. Walters, W. et al. mSystems 1, (2015). 8. Callahan, B. J. et al. Nat. Methods 13, 581–583 (2016). 9. Hall, M. & Beiko, R. G. Microbiome Analysis: Methods and Protocols113–129 (Springer, 2018). 10. Philipson, C. et al. Bio-Protoc. 7, e2622 (2017).

A. B. Regberg↗

Mercury Speciation via Diffusive Gradients Thin-Films Technology

Objectives: Develop and test various diffusive gradient in thin films (DGT) samplers for mercury - SRNL is developing reactive DGTS (rDGTs). Test chemistry to differentiate methylmercury from total and/or inorganic mercury in environmental samples. Fabricate and test rDGT samplers for deployment. Deploy the rDGTs in variable settings. Mercury is a persistent-bioaccumulative-toxic environmental pollutant. Mercury exists in different species such as elemental, inorganic, and methyl. Mercury speciation determine mercury behavior and toxicity. For example, methylmercury strongly accumulates in biota such as fish resulting in potential human health impacts. DGTs are innovative samplers to measure water concentration by diffusion and capture. Types of Hg DGTs used: Total Hg, Inorganic Hg, and Methyl Hg. Deployment Sites: Upper Three Runs, Lower Three Runs, Steele Creek, East Fork Poplar Creek (SRNL Sites), Horizons Creek, NOA Creek, Bruners Creek (ORNL Sites). DGT concentration estimates closely matched alternative measurements for soluble mercury at each Oak Ridge site - DGTs did not respond to particulate mercury. DGTs provide a representative measure for biota uptake since they are left out longer which allows for an average exposure concentration. DMA-80 provided an efficient and quick analysis. Variability in site location made a difference in Hg species. DGT preparations and sampling wasn't as quick and simple as microcolumn technology. Copper reagent degraded agarose gel - more work and cleaner data are needed to assess speciation in rDGTs. Future Work: Use cross-linked polyacrylamide for the collection layer for a stronger plastic. Make a copper diffusion layer without agarose. Test copper separation in lab using realistic stream conditions such as high organic carbon.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molten Salt Sampling Techniques and Analytical Approaches

Recent global interest in pyroprocessing and molten salt reactors has brought salt sampling methods and techniques back to the forefront of nuclear safeguards concerns. Issues with uranium supplies have also encouraged various countries to pursue advanced nuclear fuel cycles. Tracking nuclear material in molten salt has proven to be a challenge and updating molten salt sampling will greatly help in this endeavor. Molten salt is problematic to sample due to salt stratification, lack of homogeneity, solids, and difficulty with hot cell adaptations. Various salt sampling techniques have been used since before the 1960s including surface, spoon/spatula, and bar solidification. Since then, new types of sampling techniques have been developed to improve sampling results. These include rod/dip, pipet, suction, filtered sampling along with devices such as the Valve Core Sampler and the Multi-Level Sampler. These different approaches are being analyzed and improved upon along with developing requirements for an improved salt sampling device. Work continues to develop salt samplers that are more robust, easier to segment, collect at a specific depth, can work with filters, and can collect fines. Sampling parameters are also being narrowed in terms of stirring, settling time, filtration, depth, etc. In the future, we hope to address deficiencies for process control and nuclear material accountancy control by determining the best way to collect samples that minimizes contaminants and is representative. A compilation of salt sampling approaches, analyses techniques, and an evaluation of findings will be presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MOOSE ProbML: Parallelizable Probabilistic Machine Learning and Uncertainty Quantification Capabilities

The Multiphysics Object Oriented Simulation Environment (MOOSE) is a widely used open- source finite element software for performing multiphysics multiscale simulations in a massively parallel fashion. Recently, the computational team at Idaho National Laboratory (INL) has implemented Probabilistic Machine Learning (ProbML) capabilities in MOOSE—in a parallelized fashion—and enable active learning with large-scale computational models for tasks such as surrogate model development, scale bridging, forward/inverse uncertainty quantification (UQ), Bayesian optimization, etc. This presentation summarizes these developments in MOOSE along with demonstrations on several real applications relevant to nuclear energy. At the fundamental level, samplers like Monte Carlo/Latin Hypercube, variance reduction, parallelized Markov Chain Monte Carlo (MCMC) support uncertainty propagation in both forward and inverse settings. These samplers can be integrated with the Gaussian processes (GP) suite in MOOSE, which offer several variants like scalar GPs, multi-output GPs, and deep GPs, to enable active learning. These GPs can be tuned using gradient-based optimization methods like Adam and its variants or gradient-free methods like the elliptical slice sampler (a variant of MCMC adept under Gaussian settings) for more complex covariance kernels or likelihoods whose gradient computations can be cumbersome. A variety of batch acquisition functions permit parallelized evaluation of the computational model and support different learning objectives with high efficiency like Bayesian inference, global surrogate development, optimization, etc. Furthermore, libtorch integration supports training, evaluation, and re-training of neural networks and other complex machine learning models in active learning settings. The impacts of these developments are shown on several real applications: (1) nuclear fuel inverse UQ and model inadequacy assessment using the Kennedy O’Hagan framework; (2) uncertainty aware surrogate modeling for additive manufacturing to predict field quantities; (3) nuclear reactor rare events analysis; and (4) complex fluid flow prediction using a global surrogate with quantified prediction uncertainty. Finally, the outlook of MOOSE ProbML is discussed for both outer-loop and inner-loop computations in the broad view to accelerate fuels and materials qualification, address gaps in knowledge and data, and assess new reactor/fuel systems.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Extension of SCALE/Sampler’s sensitivity analysis

Nuclear data are a major source of uncertainties in reactor physics calculations. The propagation of nuclear data uncertainties to important system responses is instrumental when determining appropriate safety margins in reactor safety analyses. It is also important to understand the major contributors to the observed uncertainties to make recommendations for further measurements and evaluations and aid in the understanding of the studied system. The SCALE code system allows for nuclear data uncertainty analysis based on the random sampling approach as implemented in SCALE’s Sampler sequence. Sampler was recently extended by a sensitivity analysis in terms of the calculation of two correlation-based sensitivity indices. This analysis allows for the identification of the top contributing nuclear reactions to any analyzed output uncertainty. This paper presents the sensitivity indices, along with their interpretation and limitations. It demonstrates the application in an eigenvalue and decay heat analysis for a boiling water reactor fuel assembly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The “Brookhaven Brassie” and the Response to the Three Mile Island Accident

In the mid-1970s, American civil defense authorities became increasingly concerned with the potential threat of fission reactor accidents. Research from the Defense Civil Preparedness Agency began to be aimed not just at the ever-present threat of nuclear warfare, but also peacetime emergencies as part of a "dual use" philosophy. The Brookhaven National Laboratory received funding to create a prototype radioiodine air sampling system, with multiple publications detailing the creation of the air sampler itself and a special CD V-700 survey meter that accompanied it. In late March 1979, the system found its first operational employment at the reactor accident at Three Mile Island, Pennsylvania. Despite successful use and further study, the BNL Air Sampler was not widely fielded by the federal government. However, lessons learned from its employment and development may be applicable to contemporary radiological emergency response.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

NASA's Aerosol Sampling Experiment Summary

In a spacecraft cabin environment, the size range of indoor aerosols is much larger and they persist longer than on Earth because they are not removed by gravitational settling. A previous aerosol experiment in 1991 documented that over 90 of the mass concentration of particles in the NASA Space Shuttle air were between 10 m and 100 m based on measurements with a multi-stage virtual impactor and a nephelometer (Liu et al. 1991). While the now-retired Space Shuttle had short duration missions (less than two weeks), the International Space Station (ISS) has been continually inhabited by astronauts for over a decade. High concentrations of inhalable particles on ISS are potentially responsible for crew complaints of respiratory and eye irritation and comments about 'dusty' air. Air filtration is the current control strategy for airborne particles on the ISS, and filtration modeling, performed for engineering and design validation of the air revitalization system in ISS, predicted that PM requirements would be met. However, aerosol monitoring has never been performed on the ISS to verify PM levels. A flight experiment is in preparation which will provide data on particulate matter in ISS ambient air. Particles will be collected with a thermophoretic sampler as well as with passive samplers which will extend the particle size range of sampling. Samples will be returned to Earth for chemical and microscopic analyses, providing the first aerosol data for ISS ambient air.

Thermophoretic sampler↗

Sampling Indoor Aerosols on the International Space Station

In a spacecraft cabin environment, the size range of indoor aerosols is much larger and they persist longer than on Earth because they are not removed by gravitational settling. A previous aerosol experiment in 1991 documented that over 90 of the mass concentration of particles in the NASA Space Shuttle air were between 10 m and 100 m based on measurements with a multi-stage virtual impactor and a nephelometer (Liu et al. 1991). While the now-retired Space Shuttle had short duration missions (less than two weeks), the International Space Station (ISS) has been continually inhabited by astronauts for over a decade. High concentrations of inhalable particles on ISS are potentially responsible for crew complaints of respiratory and eye irritation and comments about 'dusty' air. Air filtration is the current control strategy for airborne particles on the ISS, and filtration modeling, performed for engineering and design validation of the air revitalization system in ISS, predicted that PM requirements would be met. However, aerosol monitoring has never been performed on the ISS to verify PM levels. A flight experiment is in preparation which will provide data on particulate matter in ISS ambient air. Particles will be collected with a thermophoretic sampler as well as with passive samplers which will extend the particle size range of sampling. Samples will be returned to Earth for chemical and microscopic analyses, providing the first aerosol data for ISS ambient air.

Thermophoretic sampler↗

Generalized Bayesian Framework for Evaluation of Integral Benchmark Experiments

A recently published generalized Bayesian optimization framework has provided a way to retract any or all of the three common assumptions underlying the conventional Generalized Linear Least Squares (GLLS) optimization method based on the concepts introduced in reference two. These assumptions are: 1. Perfection: The model used for data evaluation and the prior probability distribution function (PDF) of generalized* data are perfect; 2. Normality: The prior and posterior PDF are normal; and 3. Linearity: The model is linear. In this work we outline how the framework in 1 could be directly adopted for improved evaluation of nuclear criticality integral benchmark experiments (IBEs) by: 1. Removing the first assumption alone by utilizing the concept of imperfections introduced in 1 to enable evaluation in the presence of discrepancies between the data and model or of missing covariance information by a GLLS method that will be seen as a generalization of the conventional GLLS method employed by the TSURFER code, and by 2. Removing the remaining two assumptions by implement- ing a Markov Chain Monte Carlo method for computation of the posterior PDF in the SAMPLER code, where TSURFER and SAMPLER are the uncertainty quantification (UQ) codes for IBEs in the SCALE code system based on the GLLS, and the stochastic method, respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Field-Scale Lysimeter Studies of Glass and Cementitious Waste Forms at the Hanford Site - 20392

The Hanford site Integrated Disposal Facility (IDF) will receive waste forms from vitrification activities at the Hanford Waste Treatment and Immobilization Plant (WTP). The waste form inventory to be disposed of at the IDF will consist of vitrified low-activity waste (LAW) in glass forms and solidified (or encapsulated) secondary wastes in cementitious forms. The IDF is a near-surface burial facility located near Hanford's Waste Treatment and Immobilization Plant in the 200 East Area of the site's Central Plateau. An extensive set of laboratory experimental data has been collected to support IDF performance assessment calculations of the eventual degradation of waste forms and mobility of contaminants. This paper describes the start of a field experiment to generate waste-form performance data on a larger scale (tens of centimeters), over a longer duration (five years or more), and under field conditions representative of the IDF. Results from this study are expected to improve model descriptions of contaminant mobility, reduce uncertainties about the representativeness of laboratory results in the IDF performance assessment, improve stakeholder confidence in the safe disposal of treated waste at the IDF, and facilitate the adoption of informed facility designs with the potential to reduce operational costs. A lysimeter test facility near Hanford's 200 West Area has been repurposed to carry out long-term assessments of waste forms buried in sediments excavated from the IDF. The waste forms are buried in large drainage lysimeters, open caissons that are two meters in diameter and three meters deep. Waste forms are buried in up to six locations in each lysimeter. Samplers collect pore water and drainage water beneath the waste forms and air from the pore space adjacent to waste forms. Sensors measure temperature, soil water content, soil water tension, and drainage flux. One lysimeter containing cementitious waste forms and one containing glass waste forms have been completed, along with a control lysimeter (without waste forms). The cementitious waste forms are Cast Stone grout formulations using a liquid secondary waste simulant and a generic Hanford high-salt simulant, as well as a hydrated lime-based grout formulation using a liquid secondary waste simulant. Technetium-99 and iodine-127 were added as tracers to monitor contaminant mobility. Glass waste forms were fabricated in two formulations (LAWA44 and ORLEC28), with rhenium and molybdenum tracers to monitor waste form degradation. The predicted performance of the waste forms in the lysimeters was modeled prior to installation to determine waste form size, tracer concentration/activity, and locations of sensors and samplers. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Possible impacts of molten salt reactors on the International Monitoring System

Molten salt reactors (MSRs) are gaining support as many countries look for ways to increase power generation and replace aging nuclear energy production facilities. MSRs have inherently safe designs, are scalable in size, can burn transuranic wastes from traditional solid fuel nuclear reactors, can store excess heat in thermal reservoirs for water desalination, and can be used to produce medical isotopes as part of the real-time liquid-fuel recycling process. The ability to remove 135 Xe in real time from the fuel improves the power production in an MSR because 135 Xe is the most significant neutron-absorbing isotope generated by nuclear fission. Xenon-135, and other radioactive gases, are removed by sparging the fuel with an inert gas while the liquid fuel is recirculated from the reactor inner core through the heat exchangers. Without effective abatement technologies, large amounts of radioactive gas could be released during the sparging process. This work examines the potential impact of radioxenon releases on samplers used by the International Monitoring System (IMS) to detect nuclear explosions. Here, atmospheric transport simulations from seven hypothetical MSRs on different continents were used to evaluate the holdup time needed before release of radioxenon so IMS samplers would register few detections. Abatement technologies that retain radioxenon isotopes for at least 120 d before their release will be needed to mitigate the impacts from a molten salt breeder reactor used to replace a nuclear power plant. A holdup time of about 150 d is needed to reduce emissions to the average level of current nuclear power plants.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Nuclear explosion monitoring network design considerations

Design of an efficient monitoring network requires information on the type and size of releases to be detected, the accuracy and reliability of the measuring equipment, and the desired network performance. This work provides a scientific basis for optimizing or minimizing networks of 133 Xe samplers to achieve a desired performance level for different levels of release. The approach of this work varies the density of sampling locations to find optimal location subsets, and to explore the properties of variations of those subsets – how crucial is a specific subset; are substitutions problematic? The choice of possible station locations is arbitrary but constrained to some extent by the location of islands, land masses, difficult topography (mountains, etc.) and the places where infrastructure exists to run and support a sampler. Performance is evaluated using hypothetical releases and atmospheric transport models that cover an entire year.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Bayesian uncertainty quantification of tristructural isotropic particle fuel silver release: Decomposing model inadequacy plus experimental noise and parametric uncertainties

Tristructural isotropic (TRISO) particle fuel is one of the most promising fuel concepts enabling high temperature and high burnup reactor operation. One dominant source of radioactivity released from the TRISO particles is silver (Ag), which is subject to a high release fraction and long decay life compared to other fission products. Previous modeling efforts using the fuel performance code BISON indicated nonnegligible uncertainties in modeling the diffusion process of fission products in TRISO compared to the Advanced Gas Reactor experiments. The overall uncertainties observed when modeling the fission product diffusion can result from uncertainties in model parameters, noisy experimental measurements, and deficiencies in the developed models. The three types of underlying uncertainties have not yet been properly quantified in open literature. Here, this paper presents the Bayesian uncertainty quantification (UQ) using massively parallelizable Markov chain Monte Carlo samplers. The uncertainties due to model parameters, model inadequacy, and experimental measurement noise are quantified, with the σ term used to represent the sum of the model inadequacy and measurement noise uncertainties. It is worth noting that this is the first time the σ term is inferred for nuclear fuel experiments, as compared to using prescribed values for uncertainty quantification in previous work. The parallelizable Markov chain Monte Carlo samplers efficiently infer the model parameters and the σ term, giving insight into physical parameters like diffusion coefficients and the combined model discrepancy and measurement noise. A subsequent forward uncertainty quantification (UQ) is also performed based on the calibration results to generate more accurate predictions of the Ag release. The model inadequacy plus experimental noise is the most dominant source of uncertainty compared to the parametric uncertainty. All the UQ analyses presented in this work are based on the second series of the irradiation experiments in the Advanced Gas Reactor program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Standoff trace explosives vapor detection at meter distances

Vapor detection is a noncontact sampling method, which is a less invasive means of explosives screening than physical swiping. Explosive vapor detection is a challenge due to the low levels of vapors available for detection. This study demonstrates that the parts-per-quadrillion sensitivity of atmospheric flow tube-mass spectrometry (AFT-MS) combined with a high-volume air sampler enables standoff detection of trace explosives vapor at distances of centimeters to meters. Standoff detection of explosives vapor was possible both upstream and downstream of the vapor source relative to room air currents. RDX vapor from a saturated source was detected at up to 2.5 m. Vapors from RDX residue and nitroglycerin residue were detected at distances up to 0.5 m. The sampling can be optimized by accounting for air movement in the room or environment, which could further extend standoff detection distances. In conclusion, using AFT-MS with a high-volume sampler could also be effective for standoff vapor detection of drugs and additional chemical threats and could be useful for security screening applications such as at mail facilities, border crossings, and security checkpoints.

47 OTHER INSTRUMENTATION↗

Variability in Ice Nucleating Particles Across Greater Houston Texas

The concentration and cloud-forming potential of a region's ice nucleating particle (INP) population have uncertain impacts on deep convective clouds. Specifically, ice nucleating particles (INPs) may affect various cloud properties related to the formation, lifetime, and precipitation of deep convective clouds. As part of the U.S. Department of Energy's TRacking Aerosol and Convection interaction ExpeRiment (TRACER) campaign, researchers from Texas A&M University deployed three Davis Rotating-drum Universal-size-cut Monitoring (DRUM) samplers throughout Greater Houston, Texas from June through September 2022. Ambient particles, collected at the surface with the DRUM samplers in four aerodynamic diameter size ranges (>3, 3–1.2, 1.2–0.34, and 0.34–0.15 μm), were analyzed in offline cold-stage ice nucleation experiments. The INP population in Greater Houston is complex, varying by site and day, but can be generalized by a weak to moderately efficient mode of INPs at −24°C and an efficient mode at −15°C. Analysis reveals that supermicron particles are largely responsible for ice nucleation warmer than −20°C across the region while submicron particles dominate at temperatures colder than −20°C. Additionally, significant spatial diversity in the INP population was observed, with differences in mean nucleation temperature between sites for nearly every size cut. Although INP concentrations were typically ∼0.08 L −1 at −20°C throughout the campaign, a notable region-wide increase in INP concentration for particles freezing at temperatures warmer than −20°C occurred from mid-August to mid-September. This comprehensive characterization of Greater Houston's INP population, including spatial, temporal, and particle size variations, can help constrain ice microphysics parameterizations in weather and climate models.

Thompson, Seth A. [Texas A & M Univ., College Stat↗

Subsurface hydrocarbon degradation strategies in low- and high-sulfate coal seam communities identified with activity-based metagenomics

Environmentally relevant metagenomes and BONCAT-FACS derived translationally active metagenomes from Powder River Basin coal seams were investigated to elucidate potential genes and functional groups involved in hydrocarbon degradation to methane in coal seams with high- and low-sulfate levels. An advanced subsurface environmental sampler allowed the establishment of coal-associated microbial communities under in situ conditions for metagenomic analyses from environmental and translationally active populations. Metagenomic sequencing demonstrated that biosurfactants, aerobic dioxygenases, and anaerobic phenol degradation pathways were present in active populations across the sampled coal seams. In particular, results suggested the importance of anaerobic degradation pathways under high-sulfate conditions with an emphasis on fumarate addition. Under low-sulfate conditions, a mixture of both aerobic and anaerobic pathways was observed but with a predominance of aerobic dioxygenases. The putative low-molecular-weight biosurfactant, lichysein, appeared to play a more important role compared to rhamnolipids. The methods used in this study—subsurface environmental samplers in combination with metagenomic sequencing of both total and translationally active metagenomes—offer a deeper and environmentally relevant perspective on community genetic potential from coal seams poised at different redox conditions broadening the understanding of degradation strategies for subsurface carbon.

59 BASIC BIOLOGICAL SCIENCES↗

Machine learning framework for quantum sampling of highly constrained, continuous optimization problems

In recent years, there is growing interest in using quantum computers for solving combinatorial optimization problems. In this work, we developed a generic, machine learning-based framework for mapping continuous-space inverse design problems into surrogate quadratic unconstrained binary optimization (QUBO) problems by employing a binary variational autoencoder and a factorization machine. The factorization machine is trained as a low-dimensional, binary surrogate model for the continuous design space and sampled using various QUBO samplers. Using the D-Wave Advantage hybrid sampler and simulated annealing, we demonstrate that by repeated resampling and retraining of the factorization machine, our framework finds designs that exhibit figures of merit exceeding those of its training set. We showcase the framework’s performance on two inverse design problems by optimizing (i) thermal emitter topologies for thermophotovoltaic applications and (ii) diffractive meta-gratings for highly efficient beam steering. This technique can be further scaled to leverage future developments in quantum optimization to solve advanced inverse design problems for science and engineering applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗