Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “retrofit design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Large-Scale Commercial Carbon Capture Retrofit of the San Juan Generating Station

Enchant Energy, L.L.C. (Enchant) was selected to conduct a Front-End Engineering Design study (FEED) for the addition of a full-scale carbon capture system to remove carbon dioxide from the flue gas emissions of the two coal-fired generating units (total of 847 MW net) at San Juan Generating Station (SJGS), using Mitsubishi Heavy Industries Americas (MHIA) KM CDR Process™. Sargent & Lundy LLC (S&L) was selected as the primary technical lead, and along with various other organizations, were able to support Enchant’s completion of the following FEED tasks: Task 1 – Project Management & Planning; Task 2 – FEED Study; Task 3 - Final FEED Study Package. The FEED study period was between October 15, 2019 to September 30, 2022.

01 COAL, LIGNITE, AND PEAT↗

DC-9 flight demonstration program with refanned JT8D engines. Volume 2: Design and construction

The nacelle configuration selected for the DC-9 had a 1595.6 mm Refan length inlet and an 1811.8 mm exhaust duct. The inlet had 1234.4 mm of acoustic treatment and the tailpipe had 1305.5 mm of equivalent length acoustic treatment. The pylon was reduced in width from 425.5 mm to 204.5 mm. Fuselage frames and titanium skin panels in the area of the pylon were reinforced or replaced to support the higher loads and engine thrust. Experimental type tooling, fabrication and assembly were used on all hardware. The design is considered certifiable and representative of the hardware that would be built as retrofit kits.

Source record↗

JT8D and JT9D jet engine performance improvement program. Task 1: Feasibility analysis

JT8D and JT9D component performance improvement concepts which have a high probability of incorporation into production engines were identified and ranked. An evaluation method based on airline payback period was developed for the purpose of identifying the most promising concepts. The method used available test data and analytical models along with conceptual/preliminary designs to predict the performance improvements, weight, installation characteristics, cost for new production and retrofit, maintenance cost, and qualitative characteristics of candidate concepts. These results were used to arrive at the concept payback period, which is the time required for an airline to recover the investment cost of concept implementation.

Gaffin, W. O.↗

Aeronautical satellite system test and implementation

This contribution reports on various aspects of the test and implementation of the new worldwide aeronautical satellite system. The system will be implemented in 1990 following several years of system design and equipment development. The full range of services and equipment will not be available immediately, but rather there will be a progressive phase-in over the first two years of service. Data services using low gain aircraft antennas are planned to be introduced first. Voice service, requiring high gain antennas is expected to begin on a full scale basis about May/June 1990. This contribution explains Inmarsat's approach to testing and authorization of equipment intended to make use of its satellites in this evolving situation. The approach is designed to permit progressive implementation of services while avoiding the need for large scale retrofitting of equipment which has already been introduced into service.

Smith, Keith↗

Can Water-Injected Turbomachines Provide Cost-Effective Emissions and Maintenance Reductions?

An investigation has been performed to evaluate the effect of water injection on the performance of the Air Force Research Laboratory (AFRL, Wright-Patterson Air Force Base (WPAFB)) experimental trapped vortex combustor (TVC) over a range of fuel-to-air and water-to-fuel ratios. Performance is characterized by combustor exit quantities: temperature and emissions measurements using rakes, and overall pressure drop, from upstream plenum to combustor exit. Combustor visualization is performed using gray-scale and color still photographs and high-frame-rate videos. A parallel investigation evaluated the performance of a computational fluid dynamics (CFD) tool for the prediction of the reacting flow in a liquid fueled combustor (e.g., TVC) that uses water injection for control of pollutant emissions and turbine inlet temperature. Generally, reasonable agreement is found between data and NO(x) computations. Based on a study assessing the feasibility and performance impact of using water injection on a Boeing 747-400 aircraft to reduce NO(x) emissions during takeoff, retrofitting does not appear to be cost effective; however, an operator of a newly designed engine and airframe might be able to save up to 1.0 percent in operating costs. Other challenges of water injection will be discussed.

Hendricks, Robert C.↗

Survey of MHD plant applications

Open-cycle MHD is one of the major R&D efforts in the Department of Energy's program to meet the national goal of reducing U.S. dependence on oil through increased utilization of coal. MHD offers an effective way to use coal to produce electric power at low cost in a highly efficient and environmentally acceptable manner. Open-cycle MHD plants are categorized by the MHD combustor oxidizer, its temperature and the method of preheat. The paper discusses MHD baseline plant design, open-cycle MHD plant in the Energy Conversion Alternatives Study (ECAS), early commercial MHD plants, conceptual studies of the engineering test facility, retrofit (addition of an MHD topping cycle to an existing steam plant), and other potential applications and concepts. Emphasis is placed on a survey of both completed and ongoing studies to define both commercial and pilot plant design, cost, and performance.

Lynch, J. J.↗

Cable-Driven Parallel Robot (CDPR) for Panelized Envelope Retrofits: Feasible Workspace Analysis

Recent decades have seen remarkable progress in the field of robotic-assisted construction. Cable-driven parallel robots (CDPRs) emerge as promising tools for automating construction processes, due to their advantageous features such as scalability, reconfigurability, compact design, and high payload-to-weight ratio. This paper uses a simple static model to determine the feasibility of a CDPR for overclad panel installation in building envelope retrofits. Given that the building facade needs to be a subset of the CDPR’s wrench-feasible workspace, we focus on the sensitivity of the workspace concerning various cable arrangements and CDPR frame sizes (e.g., height and width extensions). Our analysis indicates that no cable arrangement satisfies the requirement of complete facade coverage and avoids cable-to-panel collisions. Thus, frame extension is needed to enhance coverage. However, in densely populated areas where width extension is limited by space constraints, height extension alone is insufficient to guarantee full facade coverage. This paper pioneers the investigation of CDPRs for panelized envelope retrofits, showcasing their advantages and limitations and paving the way for further research and development.

Liu, Yifang↗

A Fast-Response High-Accuracy Overvoltage Protection Circuit for Soft-Switching Current-Source Converters

Although voltage-source converters (VSCs) have been a focus of research for decades and are widely applied in numerous applications, they face great challenges in short-circuit failures, high dv/dt and electromagnetic interference (EMI), especially using wide bandgap devices. Instead, current-source converters (CSCs) are attracting increasing attention in recent years owing to their friendliness to short-circuit faults, improved EMI, etc. For CSCs, overvoltage is the most catastrophic failure since the semiconductor devices can hardly withstand an overvoltage for a short pulse. In this paper, a fast-response high-accuracy overvoltage protection (OVP) circuit is proposed to protect CSCs from overvoltage damage. It also features a small form factor, good noise-immunity, friendly retrofit capability, and no need for active switches. In this paper, the operating principle and design guideline of the proposed OVP circuit is introduced. Its effectiveness is validated in soft-switching solid-state transformer (S4T) at 500 V. In experiments, the voltage detection error of less than 5% and a propagation delay of fewer than 400 ns have been achieved.

30 DIRECT ENERGY CONVERSION↗

Lunar Glovebox Balance with Wireless Technology

The most important equipment required for processing lunar samples is a high-quality mass balance for maintaining accurate weight inventory, security, and scientific study. After careful review, a Curation Office memo by Michael Duke in 1978 chose the Mettler PL200 to be used for sample weight measurements inside the gloveboxes (Fig. 3). These commercial off-the-shelf (COTS) balances did not meet the strict accepted material requirements in the Lunar lab. As a result, each balance housing, weighing pan, and wiring was custom retrofitted to meet Lunar Operating Procedure (LOP) 54 requirements [for material construction restrictions]. The original design drawings for the custom housings, readout support stands, and wiring were done by the JSC engineering directorate. The 1977- 1978 schematics, drawings, and files are now housed in the curation Data Center. Per the design specifications, the housing was fabricated from aluminum grade 6061 T6, seamless welds, and anodized per MIL-A-8625 type I, class I. The balance feet were TFE Teflon and any required joints were sealed with Viton A gaskets. The readout display and support stands outside the glovebox were fabricated from 300 series stainless steel with #4 finish and mounted to the glovebox with welded bolts. Wire harnesses that linked the balance with the outside display and power were encapsulated with TFE Teflon and transported through custom Deutsch wire bulk head pass-through systems from inside to outside the glovebox. These Deutsch connectors were custom fabricated with 316L stainless steel bodies, Viton A O-rings, aluminum 6061 with electroless nickel plating, Teflon (replacing the silicone), and gold crimp connectors (no soldering). Many of the Deutsch connectors may have been used in the Apollo program high vacuum complex in building 37 and date to about 1968 to 1970.

Zeigler, Ryan A.↗

The role of air sealing while ground source heat pump system retrofits in the U.S. single-family houses

Widespread commercial adoption of ground source heat pumps (GSHP) is hindered by the relatively high initial cost associated with drilling boreholes in the ground to deploy ground heat exchangers. Reducing the energy demand of buildings has the potential to reduce the required borehole length and the associated drilling costs. In single-family residential buildings, air sealing can significantly lower heating energy usage, according to recent studies and reports. Thus, air sealing in conjunction with GSHP retrofits can lower the required GSHP system's capacity and borehole length to meet the thermal demands of the buildings. In order to understand the role of combining air sealing with GSHP retrofit quantitatively, the current study employs a whole building energy simulation tool integrated with an advanced design tool for the ground heat exchanger to determine changes in required GSHP capacity, total borehole length, and building energy consumption for with- and without-air sealing in single-family houses in 3 climate zones in the United States. The study considers one representative city for each climate zone, Phoenix, AZ for a hot climate, Seattle, WA for a moderate climate, and Minneapolis, MN for a cold climate. The results from this study show that reducing air infiltration from 0.8 ACH to the minimum ventilation requirement (0.35 ACH) can reduce borehole length requirement by up to 24% in Phoenix, 32% in Seattle, and 70% in Minneapolis. A similar magnitude of reduction can be seen for GSHP capacity and total building energy usage as well.

Prem Anand Jayaprabha, Jyothis Anand↗

Operational Experience from Solar Thermal Energy Projects

Over the past few years, Sandia National Laboratories were involved in the design, construction, and operation of a number of DOE-sponsored solar thermal energy systems. Among the systems currently in operation are several industrial process heat projects and the Modular Industrial Solar Retrofit qualification test systems, all of which use parabolic troughs, and the Shenandoah Total Energy Project, which uses parabolic dishes. Operational experience has provided insight to both desirable and undesirable features of the designs of these systems. Features of these systems which are also relevant to the design of parabolic concentrator thermal electric systems are discussed. Other design features discussed are system control functions which were found to be especially convenient or effective, such as local concentrator controls, rainwash controls, and system response to changing isolation. Drive systems are also discussed with particular emphasis of the need for reliability and the usefulness of a manual drive capability.

Cameron, C. P.↗

Analysis of different operating strategies of thermal energy storage with radiant cooling system

Thermal energy storage systems in building cooling applications have been explored extensively as a peak load-shifting technology. Thermal energy storage performance has been recognized and studied from an energy cost-savings point of view because of peak-valley price differences, but not many studies have been conducted from an energy savings viewpoint. This study experimentally investigates the performance of the energy storage-retrofitted to a ceiling-type radiant cooling system. To study the performance, a water-based storage system was designed and developed for an academic office building equipped with a radiant cooling system. The water in the storage tank was cooled to a certain storage temperature in the nighttime, and the same water was used during the daytime for meeting the cooling load. Different combinations of charging and discharging schedules were analyzed. The key objective of the study was to achieve energy savings and energy-cost savings simultaneously. This objective was accomplished by identifying the major factors contributing to the energy consumption of the storage-retrofitted cooling system and devising novel operating strategies, leading to an enhanced energy savings potential. Two operating strategies comprising 24 operating scenarios were compared and the storage was used to dispatch the load for 3 hours of the day as a full storage unit. Results showed that in hot and dry climate conditions, using the storage with the radiant cooling system offered energy savings of 3% to 14%. The energy-cost analysis was also performed using a time-of-day electricity tariff plan. The energy-cost savings varied from 17.5% to 22.4% for these operating scenarios.

25 ENERGY STORAGE↗

Engine component improvement: JT8D and JT9D performance improvements

A feasibility analysis screening method for predicting the airline acceptance of a proposed engine performance improvement modification was developed. Technical information derived from available test data and analytical models is used along with conceptual/preliminary designs to establish the predicted performance improvement, weight and installation characteristics, the cost for new production and retrofit, maintenance cost and qualitative characteristics of the performance improvement concepts being evaluated. These results are used to arrive at the payback period, which is the time required for an airline to recover the investment cost of concept implementation, and to predict the amount of fuel saved by a performance improvement concept. The assumptions used to calculate the payback period and fuel saved are discussed. A summary of the results when the screening method is applied is presented for several representative JT8D and JT9D performance improvement concepts. An example of the input information used to develop the summary results is shown.

Gaffin, W. O.↗

Powder satellite-reduction apparatus and method for gas atomization process

The broad applicability of at least certain aspects of the present invention derives from the ability to determine the critical location where secondary satellite formation occurs for any atomization system or design and allows for the rapid assessment of the effectiveness of various satellite reduction strategies, including but not limited to several embodiments detailed herein. Aspects of this invention can be utilized during initial atomization system design in order to evaluate effective chamber geometries and enabling strategies which reduce/eliminate satelliting, or can be retrofit to existing systems and allows for economic evaluation of effectiveness based off of initial capital expenditures versus increased operating requirements/expenses.

Anderson, Iver E.↗

Versatile semi-batch apparatus for manometric measurement of gas–solid reaction rates

In this study, we describe the design, construction, operation, and performance of a simple and versatile semi-batch reactor that is especially useful for measurement of gas/solid reaction rates at pressures in the range of 1 mTorr to 1500 Torr. The reactor operates by repeatedly imposing small AC modulations of reactant gas pressure on top of a much larger DC pressure background. Based on the rate of pressure relaxation following each AC pulse, the reaction rate is determined. Our design is characterized by modular construction from off-the-shelf, ultra-high-vacuum-compatible components, which facilitate easy retrofitting and adaptation to a range of experimental conditions. Automated experiment control and data acquisition is accomplished via a custom National Instruments © LabView virtual instrument. Data analysis is automated using a custom series of Mathworks © Matlab scripts. We demonstrate reactor performance through measurements of hydrogenation kinetics for a composite H 2 getter material consisting of 1,4-bis(phenylethynyl)benzene mixed with a palladium/carbon catalyst.

47 OTHER INSTRUMENTATION↗

Economic and Jobs Impacts of Point-Source Carbon Capture in Cement Industry – Case Study

The cement industry accounts for an estimated 8% of global CO2 emissions, which surpasses that of the entire aviation sector. In contrast with other industries, where CO2 emissions can be drastically reduced via electrification or fuels substitution, cement production releases CO2 as part of its process, during the calcination of carbonates to yield oxides. Thus, point-source carbon capture has become a key technology in the cement industry’s decarbonization. Apart from the expected environmental benefits, point-source carbon capture in the cement industry can yield important economic benefits and create jobs. The objective of this study was to perform a preliminary assessment of the economic and workforce impacts associated with the construction and operation of a point-source carbon capture retrofit of an existing cement production facility, using as a basis the data from a front-end engineering design (FEED) study to install a 3.9 million metric tons per year (Mtpy) CO2 capture facility at Holcim Ste Genevieve cement plant in Missouri, United States of America. The advanced carbon capture technology used in this FEED study was Air Liquide’s Cryocap™ FG carbon capture technology. The study evaluated the direct, indirect, and induced economic impacts of the construction, operation, and maintenance activities of the project over its lifespan. It also covered how the project will generate new jobs, their nature, and quantity, along with strategies to prepare the workforce. To perform this study, construction, operation, and maintenance cost estimates, as well as construction and operation staffing plans from the FEED study were input into IMPLAN version 7.5 software, licensed by IMPLAN Group LLC (Huntersville, VC), to predict the direct, indirect and induced economic impacts of the project using industry multipliers from the software. Additionally, recruitment strategies were developed for hiring individuals who belong to groups that are historically underserved or underrepresented, as well as anticipated recruitment of workers from the local community (whether training will be required or if the skills are associated with an existing labor force). The analysis estimated that the construction and operation of the carbon capture at Holcim Ste. Genevive will result in over 24 thousand work-years of job opportunities, close to USD 10 billion of economic impacts, including over USD 460 million of tax revenue. These results encompass the direct, indirect, and induced effects. A strategy to maximize hiring from the project and neighboring counties was developed, leveraging training agreements with local trade groups and universities. The result of this study can be used for a strategic preliminary assessment of the potential regional economic and job impacts of retrofitting existing cement plants with point source carbon systems, and its methodology can be replicated to individual projects to aid in planning and workforce development.

01 COAL, LIGNITE, AND PEAT↗

Solar heating and cooling demonstration project at the Florida solar energy center

The retrofitted solar heating and cooling system installed at the Florida Solar Energy Center is described. The system was designed to supply approximately 70 percent of the annual cooling and 100 percent of the heating load. The project provides unique high temperature, nonimaging, nontracking, evacuated tube collectors. The design of the system was kept simple and employs five hydronic loops. They are energy collection, chilled water production, space cooling, space heating and energy rejection. Information is provided on the system's acceptance test results operation, controls, hardware and installation, including detailed drawings.

Source record↗

Large-scale wind-tunnel tests of inverting flaps on a STOL utility aircraft model

A unique inverting flap system was investigated on a large scale deflected slipstream model in the Ames 40 by 80 foot wind tunnel. The subject tests utilized 33% chord double-slotted flaps on a low aspect ratio wing that was fully immersed in the propeller slipstream. Evaluation of the flap effectiveness is aided by comparisons with the results of tests of other flap systems on the same twin propeller, twin tail boom STOL utility aircraft mode. No extreme or abrupt force or moment increments were encountered when the flaps were deflected through a wide range, corresponding to the complete retraction/extension spectrum. The lift and descent capability of the inverting flaps compared very favorably with that of the other flap systems that have been tested on this model, including some with much greater mechanical complexity. As expected, the flaps caused large nose down, pitching moment increments at the high lift settings; however, the trimmed characteristics are still competitive with those obtained from the more complicated flap systems. It is believed that these flaps may have promising potential application to the design of relatively simple STOL utility aircraft with improved performance capabilities. In addition, they may merit consideration as retrofits to existing aircraft with less effective flap systems.

Feistel, T. W.↗