Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “resonator temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Pressure dependence of the absolute rate constant for the reaction OH + C2H2 from 228 to 413 K

The pressure dependence of the absolute rate constant for the reaction of the hydroxyl radical with acetylene, important in both atmospheric and combustion chemistry, is determined for temperatures between 228 and 413 K. The flash photolysis-resonance fluorescence technique was employed at five temperatures over wide ranges of pressure and acetylene concentrations, with the OH produced by water photolysis and hydroxyl resonance fluorescent photons measured by multiscaling techniques. Results indicate that, except at the lowest temperature, the bimolecular rate constant for the reaction depends strongly on total pressure, with the pressure effect becoming more pronounced with increasing temperature. At limiting high pressures, the rate constant is found to be equal to 6.83 + or - 1.19 x 10 to the -12th exp (-646 + or - 47/T) cu cm/molecule per sec, where T is the temperature. Results thus demonstrate the importance of environmental conditions in theoretical studies of atmospheric and combustion product compositions

Michael, J. V.↗

Charge Condensation and Lattice Coupling Drives Stripe Formation in Nickelates

Revealing the predominant driving force behind symmetry breaking in correlated materials is sometimes a formidable task due to the intertwined nature of different degrees of freedom. This is the case for La 2–x Sr x NiO 4+δ , in which coupled incommensurate charge and spin stripes form at low temperatures. Here, we use resonant x-ray photon correlation spectroscopy to study the temporal stability and domain memory of the charge and spin stripes in La 2–x Sr x NiO 4+δ . Although spin stripes are more spatially correlated, charge stripes maintain a better temporal stability against temperature change. More intriguingly, charge order shows robust domain memory with thermal cycling up to 250 K, far above the ordering temperature. Furthermore, these results demonstrate the pinning of charge stripes to the lattice and that charge condensation is the predominant factor in the formation of stripe orders in nickelates.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simons Observatory Microwave SQUID Multiplexing Readout: Cryogenic RF Amplifier and Coaxial Chain Design

The Simons Observatory (SO) is an upcoming polarization-sensitive cosmic microwave background experiment on the Cerro Toco Plateau (Chile) with large overlap with other optical and infrared surveys (e.g., DESI, LSST, HSC). To enable the readout of O(10,000) detectors in each of the four telescopes of SO, we will employ the microwave SQUID multiplexing technology. With a targeted multiplexing factor of O(1000), microwave SQUID multiplexing has never been deployed on the scale needed for SO. Here we present the design of the cryogenic coaxial cable and RF component chain that connects room temperature readout electronics to superconducting resonators that are coupled to transition edge sensor bolometers operating at sub-Kelvin temperatures. We describe design considerations including cryogenic RF component selection, system linearity, noise, and thermal power dissipation.

47 OTHER INSTRUMENTATION↗

Mapping the unoccupied state dispersions in Ta 2 NiSe 5 with resonant inelastic x-ray scattering

The transition metal chalcogenide Ta 2 NiSe 5 undergoes a second-order phase transition at T c = 328 K involving a small lattice distortion. Below T c , a band gap at the center of its Brillouin zone increases up to about 0.35 eV. In this work, we study the electronic structure of Ta 2 NiSe 5 in its low-temperature semiconducting phase, using resonant inelastic x-ray scattering (RIXS) at the Ni L 3 -edge. In addition to a weak fluorescence response, we observe a collection of intense Raman-like peaks that we attribute to electron-hole excitations. Using density functional theory calculations of its electronic band structure, we identify the main Raman-like peaks as interband transitions between valence and conduction bands. Further, by performing angle-dependent RIXS measurements, we uncover the dispersion of these electron-hole excitations that allows us to extract the low-energy boundary of the electron-hole continuum. From the dispersion of the valence band measured by angle-resolved photoemission spectroscopy, we derive the effective mass of the lowest unoccupied conduction band.

36 MATERIALS SCIENCE↗

Novel technique to measure the microwave response of high T(c) superconductors between 4.2 and 200 K

This paper describes a novel technique for measurements of the complex surface impedance Z(s) of high-T(c) superconductors over an extremely wide range of temperature, from 4.2 K and at least 200 K. The technique uses a superconducting Pb-plated Cu high-Q-cavity resonator operated at an ambient temperature of 4.2 K, with the sample (typically a 3-mm-diam x 1-mm-thick disk) mounted on a sapphire rod in the center of cavity, at a high B-field and thermally insulated from the cavity walls, making it possible to control the sample temperature externally. Since the cavity characteristics are dominated by the sample properties (the contribution of the Pb-covered walls maintained at 4.2 K is negligible), measurement of the cavity Q and resonant frequency makes it possible to measure Zs as a function of the sample temperature. The Z(s) values for bulk Y1Ba2Cu3O(y) and La(1.85)Sr(0.15)CuO4 were measured over a temperature range 4.2-100 K.

Sridhar, S.↗

High-temperature measurements of Q-factor in rotated X-cut quartz resonators

The Q-factors of piezoelectric resonators fabricated from natural and synthetic quartz with a 34 deg rotated X-cut orientation were measured at temperatures up to 325 C. The synthetic material, which was purified by electrolysis, retains a higher enough Q to be suitable for high temperature pressure-transducer applications, whereas the natural quartz is excessively lossy above 200 C for this application. The results are compared to results obtained previously at AT-cut resonators.

Fritz, I. J.↗

Line formation in the solar chromosphere. I - The C II resonance lines observed with OSO 8

The temperature structure of the upper chromosphere is investigated using center-to-limb measurements of the C II resonance lines at 1335 A from the University of Colorado spectrometer aboard OSO 8. Spectrum synthesis of these lines shows them to be extremely sensitive to the temperature and the physical extent of the 20,000 K plateau proposed by Vernazza et al (1973). Hydrostatic equilibrium models of the quiet chromosphere are computed to obtain theoretical spectra of the Lyman lines and continuum as well as the center-to-limb behavior of the C II lines. Good agreement is found with observations for a plateau at 16,500 K with about 25% more material than that of Vernazza et al.

Lites, B. W.↗

Millimeter-band oscillations based on resonant tunneling in a double-barrier diode at room temperature

A double-barrier diode at room temperature has yielded oscillations with fundamental frequencies up to 56 GHz and second harmonics up to 87 GHz. The output powers at these frequencies were about 60 and 18 microW, respectively. These results are attributed to a recent improvement in the material parameters of the device and to the integration of the device into a waveguide resonator. The most successful diode to date has thin (about 1.5 nm) AlAs barriers, a 4.5-nm-wide GaAs quantum well, and 2 x 10 to the 17th/cu cm doping concentration in the n-GaAs outside the barriers. This particular diode is expected to oscillate at frequencies higher than those achieved by any reported p-n tunnel diode.

Brown, E. R.↗

Wireless Capacitive Pressure Sensor With Directional RF Chip Antenna for High Temperature Environments

This paper presents the design, fabrication and characterization of a wireless capacitive pressure sensor with directional RF chip antenna that is envisioned for the health monitoring of aircraft engines operating in harsh environments. The sensing system is characterized from room temperature (25 C) to 300 C for a pressure range from 0 to 100 psi. The wireless pressure system consists of a Clapp-type oscillator design with a capacitive MEMS pressure sensor located in the LC-tank circuit of the oscillator. Therefore, as the pressure of the aircraft engine changes, so does the output resonant frequency of the sensing system. A chip antenna is integrated to transmit the system output to a receive antenna 10 m away.The design frequency of the wireless pressure sensor is 127 MHz and a 2 increase in resonant frequency over the temperature range of 25 to 300 C from 0 to 100 psi is observed. The phase noise is less than minus 30 dBcHz at the 1 kHz offset and decreases to less than minus 80 dBcHz at 10 kHz over the entire temperature range. The RF radiation patterns for two cuts of the wireless system have been measured and show that the system is highly directional and the MEMS pressure sensor is extremely linear from 0 to 100 psi.

Pressure sensor↗

Thermoelastic properties of zircon: Implications for geothermobarometry

Abstract A thermal-pressure equation of state has been determined for zircon (ZrSiO4) that characterizes its thermoelastic behavior at metamorphic conditions. New pressure-volume (P-V) data from a “Mud Tank” zircon have been collected from 1 bar to 8.47(1) GPa using X-ray diffraction, and elastic moduli were measured from room temperature up to 1172 K by resonance ultrasound spectroscopy. These data were fitted simultaneously with temperature-volume (T-V) data from the literature in EosFit7c using a new scaling technique. The parameters of a third-order Birch-Murnaghan EoS with a Mie-Grüneisen-Debye model for thermal pressure have compressional EoS parameters K0T = 224.5(1.2) GPa, K0T' = 4.90(31) with a fixed initial molar volume V0 = 39.26 cm3/mol and thermal parameters γ0 = 0.868(15), q = 2.37(80), and ΘD = 848(38) K. EoS parameters that describe the variation of unit-cell parameters with pressure and temperature were determined using an isothermal-type EoS. This new EoS confirms that zircons are stiffer than garnets and exhibit a much lower thermal expansion. This results in steep isomekes between zircon and garnets, which makes zircon trapped as inclusions in garnets at metamorphic conditions a good piezothermometer.

Geochemistry & Geophysics↗

Microwave Frequency Discriminator With Sapphire Resonator

Cooled sapphire resonator provides ultralow phase noise. Apparatus comprises microwave oscillator operating at nominal frequency of about 8.1 GHz, plus frequency-discriminator circuit measuring phase fluctuations of oscillator output. One outstanding feature of frequency discriminator is sapphire resonator serving as phase reference. Sapphire resonator is dielectric ring resonator operating in "whispering-gallery" mode. Functions at room temperature, but for better performance, typically cooled to operating temperature of about 80 K. Similar resonator described in "Sapphire Ring Resonator for Microwave Oscillator" (NPO-18082).

Santiago, David G.↗

Nonlinear absorption in AlGaAs/GaAs multiple quantum well structures grown by metalorganic chemical vapor deposition

This paper reports the study of growth conditions for achieving the sharp exciton resonances and low-intensity saturation of these resonances in AlGaAs-GaAs multiple quantum well structures grown by metalorganic chemical vapor deposition. Low growth temperature is necessary to observe this sharp resonance feature at room temperature. The optimal growth conditions are a tradeoff between the high temperatures required for high quality AlGaAs and low temperatures required for high-purity GaAs. A strong optical saturation of the excitonic absorption has been observed. A saturation density as low as 250 W/sq cm is reported.

Lee, H. C.↗

Measuring Q And f(sub r) Of A Microwave Cavity: Part I

Method of measuring quality factor (Q) and frequency of resonance (f(subr)) of microwave cavity exploits two inflection points of power-vs.-frequency resonance curve of cavity. Intended particularly for use with microwave cavity in which sample of lossy dielectric material heated to specified high temperature by microwave power at resonant frequency. Accurate measurement contributes to enhanced monitoring and control in contactless high-temperature processing of materials. Also used with small spherical sample to determine temperature dependence of complex dielectric constant.

Barmatz, Martin B.↗

In-Sodium Testing of a Prototype Thermoacoustic Power Sensor for Sodium-Cooled Fast Reactors

The ultimate goal of this project is to develop and demonstrate a thermoacoustic power sensor (TAPS) for Sodium-Cooled Fast Reactors (SFRs), with potential application also envisioned to other nuclear technologies such as Lead-Cooled Fast Reactors (LFRs), Molten Salt Reactors (MSRs), in addition to Light Water Reactors (LWRs). The project was led by Westinghouse Electric Company, LLC (Westinghouse) and carried out in collaboration with Argonne National Laboratory (ANL) and the University of Pittsburgh. A TAPS is a passive (self-powered), non-invasive (wireless) sensor envisioned for measuring key parameters, such as local temperature and neutron flux, in a nuclear reactor core. The sensor generates pressure waves (i.e., sound waves) with a frequency and amplitude dependent upon nuclear operating conditions (coolant temperature or power changes). The acoustic waves are able to travel through the core and associated structures, and reach to the sensor network placed outside and/or inside of the reactor vessel. These sensors require a very small amount of power which, during loss of power events, can be provided, for example, by harvesting gamma radiation energy, thus resulting in a monitoring system that can function both during normal operation and during loss of power events. Westinghouse and the University of Pittsburgh designed and fabricated TAPS prototypes for Argonne National Laboratory (ANL) to carry out in-sodium testing to evaluate the effects of sodium on the TAPS and the performance of the TAPS technique in sodium. Argonne received a TAPS prototype from Westinghouse, and the prototype was modified such that it can be installed into a test vessel and function in sodium at elevated temperature without potentially leaking. A water mockup test apparatus was constructed to validate proper working of the prototype. An instrumentation and control (I&C) system, running on the National Instruments (NI) LabView platform, was developed to: 1) operate both the water mockup test and the in-sodium test facility; and 2) process and analyze the received acoustic signals from an array of accelerometers and the Argonne sodium-submersible high-temperature acoustic sensor. The prototype was successfully tested in a water bath at different temperatures. Water mockup tests demonstrated that the TAPS prototype is working properly and its resonance frequency changes linearly with the coolant (water) temperature. A TAPS test apparatus was constructed and integrated with the upgraded Under-Sodium Viewing (USV) sodium test facility. The integrated USV-TAPS sodium test facility has been operational. The TAPS prototype and a high-temperature sodium-submersible acoustic sensor (SSAS) developed by Argonne were both installed inside the TAPS test vessel. Being operated within argon cover gas under ambient conditions, the TAPS prototype demonstrated that it was functioning properly with a resonance frequency at 1407.2 Hz, which was successfully detected by the accelerometers mounted on the external wall of the vessel and the high-temperature SSAS installed inside the vessel. After successfully transferring sodium into the vessel, in-sodium tests of the prototype were conducted. Tests of the TAPS prototype demonstrated that the resonance frequency of the TAPS changes linearly with respect to the temperature difference between the interior of the TAPS and bulk sodium. The early tests showed that the TAPS prototype could not establish a continuous and consistent resonance in sodium. The resonance diminished before the prototype reached its operating temperature. A signal postprocessor was added to the DAQ module latterly to isolate interferences, enhance signal conditioning, improve peak detection, and generate resonance frequency versus temperature plots. After testing in molten sodium and immersion at higher temperature for several weeks, the TAPS prototype was able to establish a continuous resonance. Performance evaluation of the TAPS prototype was then conducted in sodium. The tests included the investigation of 1) the effects of the temperature difference between the TAPS and bulk sodium, 2) the effects of sodium flowrate; and 3) the performance of the different sensor-receiver systems positioned inside or outside the vessel. Results of a test demonstrated that, with limited sodium circulation, a continuous and consistent resonance of the TAPS prototype was established occasionally. The tests also demonstrated that, because of the nature of detection principles and mounting methods, the high temperature SSAS is more affected by acoustic noise, while accelerometers are more affected by vibrations, in the test environment. It is unknown why the TAPS prototype only occasionally established a continuous and consistent resonance when the TAPS temperature reached its operating temperature in molten sodium, and why it ultimately failed to resonate at all. A failure modes assessment was conducted and a few potential causes of failure were identified. Different post in-sodium tests were conducted to obtain additional information potentially relevant to the cause of the failure. Nondestructive evaluation techniques are suggested to examine the internal integrity as well as the gas mixture of the prototype. If they prove inconclusive, the prototype should be cut open to conduct a thorough inspection of its internal integrity and determine the state of the gas mixture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetostrictive ultrasonic probes

The principles underlying the design and use of magnetostrictive ultrasonic probes is illustrated by oscillograms and sketches. Attention is given to such concepts as magnetostrictive transduction, broadband pulse shaping, guided wave propagation, wave impedance, reflection, transmission, and attenuation coefficients, coupling methods, and impulse-induced resonance. A number of applications of such probes are discussed including the measurement of elastic moduli, temperature, and acoustic emission and resonance studies.

Lynnworth, L. C.↗

Stability and Phase Noise Tests of Two Cryo-Cooled Sapphire Oscillators

A cryocooled Compensated Sapphire Oscillator (CSO), developed for the Cassini Ka-band Radio Science experiment, and operating in the 8K - 10K temperature range was previously demonstrated to show ultra-high stability of sigma(sub y) = 2.5 x 10 (exp -15) for measuring times 200 seconds less than or equal to tau less than or equal to 600 seconds using a hydrogen maser as reference. We present here test results for a second unit which allows CSO short-term stability and phase noise to be measured for the first time. Also included are design details of a new RF receiver and an intercomparison with the first CSO unit. Cryogenic oscillators operating below about 10K offer the highest possible short term stability of any frequency sources. However, their use has so far been restricted to research environments due to the limited operating periods associated with liquid helium consumption. The cryocooled CSO is being built in support of the Cassini Ka-band Radio Science experiment and is designed to operate continuously for periods of a year or more. Performance targets are a stability of 3-4 x 10 (exp -15) (1 second less than or equal to tau less than or equal to 100 seconds) and phase noise of -73dB/Hz @ 1Hz measured at 34 GHz. Installation in 5 stations of NASA's deep space network (DSN) is planned in the years 2000 - 2002. In the previous tests, actual stability of the CSO for measuring times tau less than or equal to 200 seconds could not be directly measured, being masked by short-term fluctuations of the H-maser reference. Excellent short-term performance, however, could be inferred by the success of an application of the CSO as local oscillator (L.O.) to the JPL LITS passive atomic standard, where medium-term stability showed no degradation due to L.O. instabilities at a level of (sigma)y = 3 x 10 (exp -14)/square root of tau. A second CSO has now been constructed, and all cryogenic aspects have been verified, including a resonator turn-over temperature of 7.907 K, and Q of 7.4 x 10 (exp 8). These values compare to a turn-over of 8.821 K and Q of 1.0 x 10 (exp 9) for the first resonator. Operation of this second unit provides a capability to directly verify for the first time the short-term (1 second less than or equal to tau less than or equal to 200 seconds) stability and the phase noise of the CSO units. The RF receiver used in earlier tests was sufficient to meet Cassini requirements for tau greater than or equal to 10 seconds but had short-term stability limited to 2-4 x 10 (exp -14) at tau = 1 second, a value 10 times too high to meet our requirements. A new low-noise receiver has been designed to provide approximately equal to 10-15 performance at 1 second, and one receiver is now operational, demonstrating again short-term CSO performance with H maser-limited stability. Short-term performance was degraded in the old receiver due to insufficient tuning bandwidth in a 100MHZ quartz VCO that was frequency-locked to the cryogenic sapphire resonator. The new receivers are designed for sufficient bandwidth, loop gain and low noise to achieve the required performance.

Dick, G. John↗

Concentration-Dependent Solvation Structure and Dynamics of Aqueous Sulfuric Acid Using Multinuclear NMR and DFT

Sulfuric acid is a ubiquitous compound for industrial processes and aqueous sulfate solutions also play a critical role in electrolytes for many prominent battery chemistries. While the thermodynamic literature for it is quite well-developed, comprehensive studies of the solvation structure, and particularly molecular-scale dynamical and transport properties, are less available. This study applies a multinuclear NMR approach to the elucidation of the solvation structure and dynamics over a wide temperature (-10 – 50?C) and concentration (0 – 18 M) range, combining 17O shift, linewidth, and T1 relaxation measurements, 33S shift and linewidth measurements, and 1H PFG-NMR measurements of the proton self-diffusivity. In conjunction, these results indicate a crossover between two regimes of solvation structure and dynamics, occurring above the concentration associated with the deep eutectic point (~ 4.5 M), with the high-concentration regime dominated by strong water-sulfate correlation. This description was borne out in detail by the activation energy trends with increasing concentration derived from the relaxation of both the H2O/H3O+ and H2SO4/HSO4-/SO42- 17O resonances and the 1H self-diffusivity. However, the 17O chemical shift difference between the H2O/H3O+ and H2SO4/HSO4-/SO42- resonances across the entire temperature range is nevertheless strikingly linear. A computational approach coupling MD simulations and DFT NMR shift calculations to reproduce this trend is presented, which will be the subject of further development. This combination of multinuclear, dynamical NMR and computational methods, and the results furnished by this study, will provide a platform for future studies on battery electrolytes where aqueous sulfate chemistry plays a central role in the solution structure.

Bazak, Jonathan D.↗