Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “repeat sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

An analysis of the frequency characteristics of corona discharge at low pressure

Corona discharge is becoming more of a concern now that the space program is looking at higher power and voltage requirements for future missions. Improved detection methods for studying corona discharge will increase the knowledge base of how this phenomenon occurs, what effects it has on power systems, and how it is affected by outside influences. A better understanding of corona discharge will enable designers to improve on the space applications of insulation and dielectrics, and develop proper detection techniques. A test system was designed and constructed to measure the frequency spectrum of corona discharge current in low pressure. Various test samples in different arrangements were energized by ac voltage until corona discharge occurred. This same test was repeated at different pressures. The results indicate that the frequency spectrum of the discharge current changes with a change in pressure. At low pressures, the discharge frequency spectrum is concentrated in a narrow band with a peak at 17 kHz. As the pressure is increased, the spectral width increases to include components across a much broader band. Other tests were performed to correlate the frequency spectrum data to the shape of the discharge pulse and the physical appearance of the glow discharge.

T Gregory Lewis↗

Transonic Semispan Aerodynamic Testing of the Hybrid Wing Body with Over Wing Nacelles in the National Transonic Facility

A wind tunnel investigation of a 0.04-scale model of the Lockheed Martin Hybrid Wing Body (HWB) with Over Wing Nacelles (OWN) air mobility transport configuration was conducted in the National Transonic Facility at the NASA Langley Research Center under a collaborative partnership between NASA, the Air Force Research Laboratory, and Lockheed Martin Aeronautics Company. The wind tunnel test sought to validate the transonic aerodynamic performance of the HWB and to validate the efficiency benefits of the OWN installation as compared to the traditional under-wing installation. The semispan HWB model was tested in a clean wing configuration and also tested with two different nacelles representative of a modern turbofan engine and a future advanced high bypass ratio engine. The nacelles were installed in three different locations with two over-wing positions and one under-wing position. Five-component force and moment data, surface static pressure data, and aeroelastic deformation data were acquired. For the cruise configuration, the model was tested in an angle-of-attack range between -2 and 10 degrees at free-stream Mach numbers from 0.3 to 0.9 and at unit Reynolds numbers between 8 and 39 million per foot, achieving a maximum of 80% of flight Reynolds numbers across the Mach number range. The test results validated pretest computational fluid dynamic (CFD) simulations of the HWB performance including the OWN benefit and the results also exhibited excellent transonic drag data repeatability to within +/-1 drag count. This paper details the experimental setup and model overview, presents some sample data results, and describes the facility improvements that led to the success of the test.

Chan, David T.↗

Satellite Sensor Requirements for Monitoring Essential Biodiversity Variables of Coastal Ecosystems

The biodiversity and high productivity of coastal terrestrial and aquatic habitats are the foundation for important benefits to human societies around the world. These globally distributed habitats need frequent and broad systematic assessments, but field surveys only cover a small fraction of these areas. Satellite-based sensors can repeatedly record the visible and near-infrared reflectance spectra that contain the absorption, scattering, and fluorescence signatures of functional phytoplankton groups, colored dissolved matter, and particulate matter near the surface ocean, and of biologically structured habitats (floating and emergent vegetation, benthic habitats like coral, seagrass, and algae). These measures can be incorporated into Essential Biodiversity Variables (EBVs), including the distribution, abundance, and traits of groups of species populations, and used to evaluate habitat fragmentation. However, current and planned satellites are not designed to observe the EBVs that change rapidly with extreme tides, salinity, temperatures, storms, pollution, or physical habitat destruction over scales relevant to human activity. Making these observations requires a new generation of satellite sensors able to sample with these combined characteristics: (1) spatial resolution on the order of 30 to 100-m pixels or smaller; (2) spectral resolution on the order of 5 nm in the visible and 10 nm in the short-wave infrared spectrum (or at least two or more bands at 1,030, 1,240, 1,630, 2,125, and/or 2,260 nm) for atmospheric correction and aquatic and vegetation assessments; (3) radiometric quality with signal to noise ratios (SNR) above 800 (relative to signal levels typical of the open ocean), 14-bit digitization, absolute radiometric calibration less than 2%, relative calibration of 0.2%, polarization sensitivity less than 1%, high radiometric stability and linearity, and operations designed to minimize sunglint; and (4) temporal resolution of hours to days. We refer to these combined specifications as H4 imaging. Enabling H4 imaging is vital for the conservation and management of global biodiversity and ecosystem services, including food provisioning and water security. An agile satellite in a 3-d repeat low-Earth orbit could sample 30-km swath images of several hundred coastal habitats daily. Nine H4 satellites would provide weekly coverage of global coastal zones. Such satellite constellations are now feasible and are used in various applications.

aquatic↗

An investigation of wing buffeting response at subsonic and transonic speeds. Phase 1: F-111A flight data analysis. Volume 2: Plotted power spectra

Volume 2 of this three volume report is presented. This volume presents plotted variations of power spectral density data with frequency for each structural response item for each data sampled and analyzed during the course of the investigation. Some of the information contained in Volume 1 are repeated to allow the reader to identify the specific conditions appropriate to each plot presented and to interpret the data.

Benepe, D. B.↗

Comparison of video fields and frames for transform compression

Because of the interlaced television scan, the two fields that form an interlaced video frame are generated 1/60 of a second apart. If the two fields are compressed independently, the correlation between adjacent lines is unused. The transmission rate can be reduced by using a field memory to form an interlaced frame. Four test images were processed as fields and as interlaced frames, using both theoretical and experimental compression designs. For comparable mean-square error and subjective appearance, field compression requires about one-half bit per sample more than frame compression. However, the overall transmission rate - the number of bits per image times the number of images per second - is more meaningful than the number of bits per sample. When transform compression at low transmission rates merges the adjacent lines, frame compression becomes similar to field repeating, and the memory can be reduced.

Jones, H. W., Jr.↗

Artificial Satellite Analysis Program (ASAP)

Program suited for studying planetary orbit missions including mapping and flyby components. Sample data included for geosynchronous station drift cycle study. Venus radar mapping strategy, frozen orbit about Mars, and repeat ground trace orbit. Written in FORTRAN.

Kwok, Johnny H.↗

Rapid calibration of seven-hole probes

This paper summarizes the major conclusions and some of the key supporting analyses resulting from the calibration and application of two small seven hole probes at NASA Lewis Research Center. These probes can produce reasonably accurate and rapid surveys of unknown steady flow fields which may include flow angles up to 70 degrees and Mach numbers up to 0.8. The probes were calibrated with both 'complete' and 'reduced' test matrices. Both types of test matrices produced similar results suggesting the the reduced matrices are adequate for most purposes. The average accuracy fo the calibration was about the same as that achieved in previous seven hole probe calibrations. At the higher Mach numbers, the calibration was sensitive to the diameter of the free jet in the calibration facility. Over a narrow angular range at the higher Mach numbers, the system had serious repeatability problems. This lack or repeatability apparently results from aliasing of high frequency (20 to 40 Hz) noise with the data acquisition system sampling frequency of 10 Hz. Analyses show that these noise frequencies are probably not related to airflow dynamics in the connecting tubing.

Ericksen, A. L.↗

Comparison of Upright Gait with Supine Bungee-Cord Gait

Running on a treadmill with bungee-cord resistance is currently used on the Russian space station MIR as a countermeasure for the loss of bone and muscular strength which occurs during spaceflight. However, it is unknown whether ground reaction force (GRF) at the feet using bungee-cord resistance is similar to that which occurs during upright walking and running on Earth. We hypothesized-that the DRAMs generated during upright walking and running are greater than the DRAMs generated during supine bungee-cord gait. Eleven healthy subjects walked (4.8 +/- 0.13 km/h, mean +/- SE) and ran (9.1 +/- 0.51 km/h) during upright and supine bungee-cord exercise on an active treadmill. Subjects exercised for 3 min in each condition using a resistance of 1 body weight calibrated during an initial, stationary standing position. Data were sampled at a frequency of 500Hz and the mean of 3 trials was analyzed for each condition. A repeated measures analysis of variance tested significance between the conditions. Peak DRAMs during upright walking were significantly greater (1084.9 +/- 111.4 N) than during supine bungee-cord walking (770.3 +/- 59.8 N; p less than 0.05). Peak GRFs were also significantly greater for upright running (1548.3 +/- 135.4 N) than for supine bungee-cord running (1099.5 +/- 158.46 N). Analysis of GRF curves indicated that forces decreased throughout the stance phase for bungee-cord gait but not during upright gait. These results indicate that bungee-cord exercise may not create sufficient loads at the feet to counteract the loss of bone and muscular strength that occurs during long-duration exposure to microgravity.

Boda, Wanda L.↗

Thrust Measurement of Dielectric Barrier Discharge (DBD) Plasma Actuators: New Anti-Thrust Hypothesis, Frequency Sweeps Methodology, Humidity and Enclosure Effects

We discuss thrust measurements of Dielectric Barrier Discharge (DBD) plasma actuators devices used for aerodynamic active flow control. After a review of our experience with conventional thrust measurement and significant non-repeatability of the results, we devised a suspended actuator test setup, and now present a methodology of thrust measurements with decreased uncertainty. The methodology consists of frequency scans at constant voltages. The procedure consists of increasing the frequency in a step-wise fashion from several Hz to the maximum frequency of several kHz, followed by frequency decrease back down to the start frequency of several Hz. This sequence is performed first at the highest voltage of interest, then repeated at lower voltages. The data in the descending frequency direction is more consistent and selected for reporting. Sample results show strong dependence of thrust on humidity which also affects the consistency and fluctuations of the measurements. We also observed negative values of thrust, or "anti-thrust", at low frequencies between 4 Hz and up to 64 Hz. The anti-thrust is proportional to the mean-squared voltage and is frequency independent. Departures from the parabolic anti-thrust curve are correlated with appearance of visible plasma discharges. We propose the anti-thrust hypothesis. It states that the measured thrust is a sum of plasma thrust and anti-thrust, and assumes that the anti-thrust exists at all frequencies and voltages. The anti-thrust depends on actuator geometry and materials and on the test installation. It enables the separation of the plasma thrust from the measured total thrust. This approach enables more meaningful comparisons between actuators at different installations and laboratories. The dependence on test installation was validated by surrounding the actuator with a grounded large-diameter metal sleeve. Strong dependence on humidity is also shown; the thrust significantly increased with decreasing humidity, e.g., 44 percent increase as relative humidity changed from 18 percent and dew point 33 degF to 50 percent and dew point of 57 degF.

Ashpis, David E.↗

Dielectric Barrier Discharge (DBD) Plasma Actuators Thrust-Measurement Methodology Incorporating New Anti-Thrust Hypothesis

We discuss thrust measurements of Dielectric Barrier Discharge (DBD) plasma actuators devices used for aerodynamic active flow control. After a review of our experience with conventional thrust measurement and significant non-repeatability of the results, we devised a suspended actuator test setup, and now present a methodology of thrust measurements with decreased uncertainty. The methodology consists of frequency scans at constant voltages. The procedure consists of increasing the frequency in a step-wise fashion from several Hz to the maximum frequency of several kHz, followed by frequency decrease back down to the start frequency of several Hz. This sequence is performed first at the highest voltage of interest, then repeated at lower voltages. The data in the descending frequency direction is more consistent and selected for reporting. Sample results show strong dependence of thrust on humidity which also affects the consistency and fluctuations of the measurements. We also observed negative values of thrust or "anti-thrust", at low frequencies between 4 Hz and up to 64 Hz. The anti-thrust is proportional to the mean-squared voltage and is frequency independent. Departures from the parabolic anti-thrust curve are correlated with appearance of visible plasma discharges. We propose the anti-thrust hypothesis. It states that the measured thrust is a sum of plasma thrust and anti-thrust, and assumes that the anti-thrust exists at all frequencies and voltages. The anti-thrust depends on actuator geometry and materials and on the test installation. It enables the separation of the plasma thrust from the measured total thrust. This approach enables more meaningful comparisons between actuators at different installations and laboratories. The dependence on test installation was validated by surrounding the actuator with a large diameter, grounded, metal sleeve.

Ashpis, David E.↗

Spatial analysis of IRAS observations of nearby spirals

The unbiased survey of the infrared sky carried out by the Infrared Astronomy Satellite (IRAS) satellite has greatly accelerated advances in understanding the dust component of our own and external galaxies. However, most extragalactic studies to date have been based on the IRAS Point Source Catalog (PSC), which has two serious limitations. First, in sources where a significant fraction of the flux is extended, significant errors may result from using PSC fluxes in comparative studies, and these errors could be systematic if the tendency to be non-pointlike depends on physical properties of the galaxy. Additionally, use of PSC fluxes rules out any direct investigation of the spatial distribution of the IRAS emission from disks in external galaxies. Since work on the Galactic IRAS results has shown that very different physical processes can make varying contributions to the observed flux, it is important to look at a wide sample of galaxies with some spatial resolution to study the relative dominance of these processes under a variety of conditions. Here, researchers report on work they are doing to carry out this program for many nearby spirals, using an analysis package that was developed for this purpose. Researchers carried out analysis for a sample of 121 nearby spirals. The fraction of the flux contained in a point source varies from 0 to 1 across the sample, all of which are well resolved at their nominal optical diameters. There is no evidence that the galaxies of smaller angular size are less likely to be resolved by IRAS at this level. The program gives results which are quite repeatable from scan to scan; the fraction f (point source flux over total flux) at 60 microns has typical errors of 0.03 when different scans are combined. Approximately two-thirds of the sample have more flux in the extended than in the nuclear component. There is a tendency for earlier-type spirals to be less centrally concentrated, but this effect is slight and the degree of variation is large for all types. Barred spirals are also found across the spectrum of f, but are much more likely to have little or no nuclear emission.

Ball, Roger↗

Airborne Radar Study of Mars Analogs in the Southwestern United States

The search for surface and near-surface liquid water on Mars is a central part of current and planned future exploration, which include radar sounders on Mars Express and MRO and proposed synthetic aperture radar (SAR) imagers. In order to penetrate sand and dust cover, these systems are proposed for longer wavelengths (e.g, from [2]: 24 cm / L-band and 74 cm / P-band) than those considered optimal for the detection of soil moisture (6 cm / C-band). However, there has been some success in detecting soil moisture at longer wavelengths. Given the size and mass constraints for Mars missions, the optimization of radar instrument parameters for meeting science objectives, such as searching for liquid water, is essential. In this on-going study, we are using repeat coverage of Mars analog sites with multifrequency (C, L and P band) airborne radar and ground truth soil sample data to assess the detectability of soil moisture.

Greeley, R.↗

Accurate Measurements of the Dielectric Constant of Seawater at L Band

This report describes measurements of the dielectric constant of seawater at a frequency of 1.413 GHz that is at the center of the L-Sand radiometric protected frequency spectrum. Aquarius will be sensing the sea surface salinity from space in this band. The objective of the project is to refine the model function for the dielectric constant as a function of salinity and temperature so that remote sensing measurements can be made with the accuracy needed to meet the measurement goals (0.2 psu) of the Aquarius mission. The measurements were made, using a microwave cavity operated in the transmission configuration. The cavity's temperature was accurately regulated to 0.02 C by immersing it in a temperature controlled bath of distilled water and ethanol glycol. Seawater had been purchased from Ocean Scientific International Limited (OS1L) at salinities of 30, 35 and 38 psu. Measurements of these seawater samples were then made over a range of temperatures, from l0 C to 35 C in 5 C intervals. Repeated measurements were made at each temperature and salinity, Mean values and standard deviations were then computed. Total error budgets indicated that the real and imaginary parts of the dielectric constant had a relative accuracy of about l%.

Lang, Roger H.↗

A Range Correction for Icesat and Its Potential Impact on Ice-sheet Mass Balance Studies

We report on a previously undocumented range error in NASA's Ice, Cloud and land Elevation Satellite (ICESat) that degrades elevation precision and introduces a small but significant elevation trend over the ICESat mission period. This range error (the Gaussian-Centroid or 'G-C'offset) varies on a shot-to-shot basis and exhibits increasing scatter when laser transmit energies fall below 20 mJ. Although the G-C offset is uncorrelated over periods less than1 day, it evolves over the life of each of ICESat's three lasers in a series of ramps and jumps that give rise to spurious elevation trends of −0.92 to −1.90 cm yr(exp −1), depending on the time period considered. Using ICESat data over the Ross and Filchner-Ronne ice shelves we show that (1) the G-C offset introduces significant biases in ice-shelf mass balance estimates, and (2) the mass balance bias can vary between regions because of different temporal samplings of ICESat.We can reproduce the effect of the G-C offset over these two ice shelves by fitting trends to sample-weighted mean G-C offsets for each campaign, suggesting that it may not be necessary to fully repeat earlier ICESat studies to determine the impact of the G-C offset on ice-sheet mass balance estimates.

mass balance↗

Intercomparison of Field Methods for Acquiring Ground Reflectance at Railroad Valley Playa for Spectral Calibration of Satellite Data

Ground reflectance was acquired at the Railroad Valley Playa calibration site in Nevada USA using different methods of collection. The data was collected near the time and date of Landsat 8 OLI and Sentinel-2 satellite overpasses so an inter-comparison could be made with the reflectance products to determine which method was more suitable for vicarious calibration. The field spectrometers and reference panels were characterized before the field campaign. A continuous acquisition method was compared to stop and measure collections. Both acquisition methods were collected along an 80 m east-west transect as well as for a series of north-south transects over an 80 x 320 m area, with the stop and measure method being performed at random sampling locations. The measurements were performed using two field spectrometers by three teams of two people to compare the repeatability. The aim of the field campaign was to determine the variability due to the operator and the method of collection.

Lau, Ian C.↗

Intercomparison of Field Methods for Acquiring Ground Reflectance at Railroad Valley Playa for Spectral Calibration of Satellite Data

Ground reflectance was acquired at the Railroad Valley Playa calibration site in Nevada USA using different methods of collection. The data was collected near the time and date of Landsat 8 OLI and Sentinel-2 satellite overpasses so an inter-comparison could be made with the reflectance products to determine which method was more suitable for vicarious calibration. The field spectrometers and reference panels were characterized before the field campaign. A continuous acquisition method was compared to stop and measure collections. Both acquisition methods were collected along an 80 m east-west transect as well as for a series of north-south transects over an 80 x 320 m area, with the stop and measure method being performed at random sampling locations. The measurements were performed using two field spectrometers by three teams of two people to compare the repeatability. The aim of the field campaign was to determine the variability due to the operator and the method of collection.

Lau, Ian C.↗

Uncertainties in Coastal Ocean Color Products: Impacts of Spatial Sampling

With increasing demands for ocean color (OC) products with improved accuracy and well characterized, per-retrieval uncertainty budgets, it is vital to decompose overall estimated errors into their primary components. Amongst various contributing elements (e.g., instrument calibration, atmospheric correction, inversion algorithms) in the uncertainty of an OC observation, less attention has been paid to uncertainties associated with spatial sampling. In this paper, we simulate MODIS (aboard both Aqua and Terra) and VIIRS OC products using 30 m resolution OC products derived from the Operational Land Imager (OLI) aboard Landsat-8, to examine impacts of spatial sampling on both cross-sensor product intercomparisons and in-situ validations of R(sub rs) products in coastal waters. Various OLI OC products representing different productivity levels and in-water spatial features were scanned for one full orbital-repeat cycle of each ocean color satellite. While some view-angle dependent differences in simulated Aqua-MODIS and VIIRS were observed, the average uncertainties (absolute) in product intercomparisons (due to differences in spatial sampling) at regional scales are found to be 1.8%, 1.9%, 2.4%, 4.3%, 2.7%, 1.8%, and 4% for the R(sub rs)(443), R(sub rs)(482), R(sub rs)(561), R(sub rs)(655), Chla, K(sub d)(482), and b(sub bp)(655) products, respectively. It is also found that, depending on in-water spatial variability and the sensor's footprint size, the errors for an in-situ validation station in coastal areas can reach as high as +/- 18%. We conclude that a) expected biases induced by the spatial sampling in product intercomparisons are mitigated when products are averaged over at least 7 km × 7 km areas, b) VIIRS observations, with improved consistency in cross-track spatial sampling, yield more precise calibration/validation statistics than that of MODIS, and c) use of a single pixel centered on in-situ coastal stations provides an optimal sampling size for validation efforts. These findings will have implications for enhancing our understanding of uncertainties in ocean color retrievals and for planning of future ocean color missions and the associated calibration/validation exercises.

Coastal ocean color↗

Preparation of Regular Specimens for Atom Probes

A method of preparation of specimens of non-electropolishable materials for analysis by atom probes is being developed as a superior alternative to a prior method. In comparison with the prior method, the present method involves less processing time. Also, whereas the prior method yields irregularly shaped and sized specimens, the present developmental method offers the potential to prepare specimens of regular shape and size. The prior method is called the method of sharp shards because it involves crushing the material of interest and selecting microscopic sharp shards of the material for use as specimens. Each selected shard is oriented with its sharp tip facing away from the tip of a stainless-steel pin and is glued to the tip of the pin by use of silver epoxy. Then the shard is milled by use of a focused ion beam (FIB) to make the shard very thin (relative to its length) and to make its tip sharp enough for atom-probe analysis. The method of sharp shards is extremely time-consuming because the selection of shards must be performed with the help of a microscope, the shards must be positioned on the pins by use of micromanipulators, and the irregularity of size and shape necessitates many hours of FIB milling to sharpen each shard. In the present method, a flat slab of the material of interest (e.g., a polished sample of rock or a coated semiconductor wafer) is mounted in the sample holder of a dicing saw of the type conventionally used to cut individual integrated circuits out of the wafers on which they are fabricated in batches. A saw blade appropriate to the material of interest is selected. The depth of cut and the distance between successive parallel cuts is made such that what is left after the cuts is a series of thin, parallel ridges on a solid base. Then the workpiece is rotated 90 and the pattern of cuts is repeated, leaving behind a square array of square posts on the solid base. The posts can be made regular, long, and thin, as required for samples for atom-probe analysis. Because of their small volume and regularity, the amount of FIB-milling time can be much less than that of the method of sharp shards. Individual posts can be broken off for mounting in a manner similar to that of the method of sharp shards. Alternatively, the posts can be left intact on the base and the base can be cut to a small square (e.g., 3 by 3 mm) suitable for mounting in an atom probe of a type capable of accepting multiple-tip specimens. The advantage of multiple-tip specimens is the possibility of analyzing many tips without the time-consuming interchange of specimens.

Kuhlman, Kim↗