Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “refrigerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Optimal design of gas adsorption refrigerators for cryogenic cooling

The design of gas adsorption refrigerators used for cryogenic cooling in the temperature range of 4K to 120K was examined. The functional relationships among the power requirement for the refrigerator, the system mass, the cycle time and the operating conditions were derived. It was found that the precool temperature, the temperature dependent heat capacities and thermal conductivities, and pressure and temperature variations in the compressors have important impacts on the cooling performance. Optimal designs based on a minimum power criterion were performed for four different gas adsorption refrigerators and a multistage system. It is concluded that the estimates of the power required and the system mass are within manageable limits in various spacecraft environments.

Chan, C. K.↗

A helium-3 refrigerator employing capillary confinement of liquid cryogen

A condensation refrigerator suitable for operation in a zero gravity space environment was constructed. The condensed liquid refrigerant is confined by surface tension inside a porous metal matrix. Helium-4 and helium-3 gases were condensed and held in a copper matrix. Evaporative cooling of confined liquid helium-4 resulted in a temperature of 1.4K. Using a zeolite adsorption pump external to the cryostat, a temperature of 0.6 K was achieved through evaporative cooling of liquid helium-3. The amount of time required for complete evaporation of a controlled mass of liquid helium-4 contained in the copper matrix was measured as a function of the applied background power. For heating powers below 18 mW the measured times are consistent with the normal boiling of the confined volume of liquid refrigerant. At background powers above 18 mW the rapid rise in the temperature of the copper matrix the signature of the absence of confined liquid occurs in a time a factor of two shorter than that expected on the basis of an extrapolation of the low power data.

Ennis, D. J.↗

Cascade Joule-Thomson refrigerators

The design criteria for cascade Joule-Thomson refrigerators for cooling in the temperature range from 300 K to 4.2 K were studied. The systems considered use three or four refrigeration stages with various working gases to achieve the low temperatures. Each stage results in cooling to a progressively lower temperature and provides cooling at intermediate temperatures to remove the substantial amount of parasitic heat load encountered in a typical dewar. With careful dewar design considerable cooling can be achieved with moderate gas flows. For many applications, e.g., in the cooling of sensitive sensors, the fact that the refrigerator contains no moving parts and may be remotely located from the gas source is of considerable advantage. A small compressor suitable for providing the gas flows required was constructed.

Tward, E.↗

Life test results of hydride compressors for cryogenic refrigerators

A development status assessment is made, from the viewpoint of system durability, for the hydride compressors used in such cryogenic refrigerators as that of the JPL, which has operated at 29 K for 500 hours and at lower temperatures for over 1000. Attention is given to a novel hydride compressor unit which has operated through 35,000 cycles and exhibits negligible degradation of check valves, hydride particle size, and expansion valves. The power requirement for liquid hydrogen cooling can be halved through the use of recuperative hot water heating methods, making this system comparable in power use to liquid hydrogen refrigeration systems operating on electricity. Due to the lack of moving parts in hydride refrigerator designs, potential service lifetimes of many years, and perhaps decades, are being projected.

Jones, J. A.↗

Hydrogen Refrigerator Would Cool Below 10 K

Closed-cycle hydrogen refrigerator uses low-level heat energy to cool objects to temperature of 10 K. Refrigerator needs only fraction of energy of previous equipment with similar low-temperature capability. Unit compact and light in weight. With valves as only moving parts, reliable for many years. Refrigeration concept adapted to cooling superconducting magnets on magnetically levitated railcars, nuclear-particle accelerators, and variety of other cryogenic equipment.

Jones, J. A.↗

Refrigerated dynamic seal to 6.9 MPa (1000 psi)

The self sealing, high shear flow passage approach which was extended to large pressure differences was studied. In a refrigerated seal the fluid to be sealed flows through a refrigerated housing or constriction. The fluid can be frozen to the housing during the transient phase. Under steady state conditions the refrigerated seal proves to be a dynamic low leakage seal. The concept is extended to pressure differences of 6.9 MPa.

Hendricks, R. C.↗

Temperature stability limits for an isothermal demagnetization refrigerator

It is pointed out that magnetic refrigeration can provide additional cooling for infrared detectors on space missions, taking into account the Shuttle Infrared Telescope Facility (SIRTF) and the Large Deployable Reflector (LDR). From a temperature of 2 K provided by the primary cryogens, magnetic refrigerators could cool bolometers or pumped photoconductors to 0.1 K or below. Such a reduction in operating temperature would increase the sensitivity for bolometers, while the response at longer wavelengths for pumped photoconductors would be improved. Two types of magnetic refrigeration cycles have been proposed. One type uses a complete demagnetization. The present investigation is concerned with the second type, which uses a feedback-controlled isothermal demagnetization, taking into account the temperature stability limits. Attention is given to control system resolution, thermometer noise, reaction time, and thermal time constants.

Kittel, P.↗

An experimental study for a miniature Stirling refrigerator

Experimental results of a miniature two-stage Stirling cryocooler are introduced. The influence of filling gas pressure and refrigeration temperature on the refrigerating capacity along with the relationship between parameters was measured. The valley pressure corresponding to the lowest refrigeration temperature and the cooldown time versus operating pressure are discussed. The coefficient of performance and thermodynamic efficiency of the cryocooler are calculated based on experimental data.

Li, S.↗

Refrigerator Based on Chemisorption

Reversible chemical reaction generates pressurized oxygen for cooling. Concept for cryogenic refrigerator based on chemical absorption of oxygen by praseodymium/cerium oxide (PCO) compound. Refrigerator produces cryogenic liquid for cooling infrared sensors. Also used for liquefying air and separating oxygen from nitrogen in air. In chemisorption refrigerator, PCO alternately absorbs and desorbs oxygen depending on whether cooled or heated. One pair of compressors accepts oxygen while others releases it. Compressed oxygen liquefied when precooked and expanded.

Jones, Jack A.↗

A comparison of three types of pulse tube refrigerators - New methods for reaching 60 K

The three types of pulse tube refrigerator, namely the resonant, basic, and orifice designs, are compared with each other and with such common refrigerators as the Joule-Thomson and Stirling types, using an apparatus able to measure their intrinsic behavior from 30 to 300 K. Orifice pulse tubes are found capable of reaching 60 K temperature drops in a single stage. Additional advantages of the type are (1) a single, room-temperature moving part, (2) the use of moderate pressures and pressure ratios, (3) good intrinsic efficiency, and (4) the ability to operate several stages from the same pressure wave generator. The low refrigeration rate/unit mass flow means, however, that better regenerator units are required.

Radebaugh, Ray↗

Dynamic design of gas sorption J-T refrigerator

A long-life Joule-Thomson refrigerator which is heat powered, involves no sealing, and has few mechanical parts is desirable for long-term sensor cooling in space. In the gas-sorption J-T refrigerator, cooling is achieved by gas sorption (either adsorption or absorption) processes. Currently, a modular, single-stage refrigerator is being designed and built to be operated at 20 K. The design was analyzed using a dynamic model, which is described here. The model includes the kinetics of the compressors and the heat switches, the heat transfer of the pre-coolers and the heat exchangers, the on/off ratio of the check valves, and the impedance of the J-T valve. The cooling power, the cycle time, and the operating conditions were obtained in terms of the power input, the heat sink temperature, and the J-T impedance.

Chan, C. K.↗

Refrigerated dynamic seal to 6.9 MPa (1000 psi)

The self sealing, high shear flow passage approach which was extended to large pressure differences was studied. In a refrigerated seal the fluid to be sealed flows through a refrigerated housing or constriction. The fluid can be frozen to the housing during the transient phase. Under steady state conditions the refrigerated seal proves to be a dynamic low leakage seal. The concept is extended to pressure differences of 6.9 MPa.

Hendricks, Robert C.↗

Status Of Sorption Cryogenic Refrigeration

Report reviews sorption refrigeration. Developed for cooling infrared detectors, cryogenic research, and other advanced applications, sorption refrigerators have few moving parts, little vibration, and lifetimes of 10 years or more. Describes types of sorption stages, multistage and hybrid refrigeration systems, power requirements, cooling capacities, and advantages and disadvantages of various stages and systems.

Jones, Jack A.↗

A cold ejector for closed-cycle helium refrigerators

The test results are presented of an initial cold helium ejector design that can be installed on a closed cycle refrigerator to provide refrigeration at temperatures below 4.2 K. The ejector, test apparatus, instrumentation, and test results are described. Tests were conducted both at room temperature and at cryogenic temperatures to provide operational experience with the ejector as well as for future use in the subsequent design of an ejector that will provide refrigeration at temperatures below 3 K.

Johnson, D. L.↗

Stability and refrigeration of magnet cryosystems near 1.8 K using the thermomechanical effect

Magnet cryosystem options utilizing the thermomechanical effect of He II and the mechano-caloric effect for refrigeration (referred to as vortex refrigeration) are examined. The performance of the existing He II magnet refrigeration system is briefly reviewed, with attention given to superleak properties, vortex shedding, heat input, and thermodynamic cycle. It is concluded that the possibilities of magnet heat leak use for energetics and stability improvements are promising when He II is selected as magnet coolant.

Frederking, T. H. K.↗

Development and experimental test of an analytical model of the orifice pulse tube refrigerator

An analytical model for the orifice pulse tube is developed, in which the system is described in terms of average enthalpy flow with such simplifying assumptions as an ideal gas and sinusoidal pressure variation. Phasor analysis is used to represent temperature, pressure, and mass-flow rate waves in vector form. The model predictions, namely, that the refrigeration power of a pulse-tube refrigerator is proportional to the average pressure, the pulse frequency, the mass-flow ratio, and the square of the dynamic pressure ratio, were verified by experimental measurements. It was found that, as a result of the simplifying assumptions, the magnitudes of the refrigeration power predicted by the model were between three and five times greater than experimental values.

Storch, Peter J.↗

Sorption cryogenic refrigeration - Status and future

The operation principles of sorption cryogenic refrigeration are discussed. Sorption refrigerators have virtually no wear-related moving parts, have negligible vibration, and offer extremely long life (at least ten years), making it possible to obtain efficient, long life and low vibration cooling to as low as 7 K for cryogenic sensors. The physisorption and chemisorption systems recommended for various cooling ranges down to 7 K are described in detail. For long-life cooling at 4-5 K temperatures, a hybrid chemisorption-mechanical refrigeration system is recommended.

Jones, Jack A.↗

An adiabatic demagnetization refrigerator for SIRTF

An adiabatic demagnetization refrigerator (ADR) has been proposed to cool bolometric infrared detectors on the multiband imaging photometer of the Space Infrared Telescope Facility (SIRTF). One such refrigerator has been built which uses a ferric ammonium alum salt pill suspended by nylon threads in a 3-T solenoid. The resonant modes of this suspension are above 100 Hz. The heat leak to the salt pill is less than 0.5 microW. The system has a hold time at 0.1K of more than 12 h. The cold stage temperature is regulated with a feedback loop that controls the magnetic field. A second, similar refrigerator is being built at a SIRTF prototype to fly on a ballon-borne telescope. It will use a ferromagnetic shield. The possibility of using a high-Tc solenoid-actuated heat switch is also discussed.

Timbie, P. T.↗