Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reflectometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

X-Ray And Polarized Neutron Reflectometry: Characterization Of Si/Co/Si And Si/Ni/Si Systems

Technologically important metal silicides formed through interdiffusion in metal/Si systems has been probed using two complementary techniques viz. x-ray reflectivity (XRR) and polarized neutron reflectivity (PNR). Both structural and magnetic characterization with good depth resolution has been achieved in these systems. We have studied two systems Si/Co/Si and Si/Ni/Si which relate to important applications in ferromagnetic/ non-magnetic semiconductor layered structures for memory devices.

36 MATERIALS SCIENCE↗

Note: Vector reflectometry in a beam waveguide

We present a one-port calibration technique for characterization of beam waveguide components with a vector network analyzer. This technique involves using a set of known delays to separate the responses of the instrument and the device under test. We demonstrate this technique by measuring the reflected performance of a millimeter-wave variable-delay polarization modulator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Ni/Al multilayer on Si substrate by diffraction and reflectometry techniques

An ion beam deposited multilayer film of nominal thickness [Ni(200 Angst )/Al(100 Angst )]x5 on Si substrate has been characterized by X-Ray Diffraction(XRD), X-Ray Reflectivity (XRR) and Polarized neutron reflectivity(PNR). The present paper attempts to identify presence of any intermetallic compounds at the interfaces of the as-deposited sample. Structural parameters obtained from XRR and PNR are close to design values.

36 MATERIALS SCIENCE↗

Full-wave feasibility study of magnetic diagnostic based on O-X mode conversion and oblique reflectometry imaging

An innovative millimeter wave diagnostic is proposed to measure the local magnetic field and the edge current as a function of the minor radius in the pedestal region. The idea behind such diagnostic is to localize and characterize a direction of reduced reflectivity at the O-mode cutoff layer. We modeled the wave scattering and mode-conversion processes by means of the finite-element COMSOL Multiphysics code in two dimensions (2D). Sensitivity studies were performed for parameters mocking up DIII-D plasmas. Simulations confirmed the presence of a minimum in reflectivity of an externally injected O-mode beam, and confirmed that this minimum depends on the magnetic field at the cutoff, as expected from the OX mode conversion physics. This study gives confidence in the feasibility of the diagnostic.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Full-wave feasibility study of anti-radar diagnostic of magnetic field based on O-X mode conversion and oblique reflectometry imaging

An innovative millimeter wave diagnostic is proposed to measure the local magnetic field and edge current as a function of the minor radius in the tokamak pedestal region. The idea is to identify the direction of minimum reflectivity at the O-mode cutoff layer. Correspondingly, the transmissivity due to O-X mode conversion is maximum. That direction, and the angular map of reflectivity around it, contains information on the magnetic field vector B at the cutoff layer. Probing the plasma with different wave frequencies provides the radial profile of B. Full-wave finite-element simulations are presented here in 2D slab geometry. Modeling confirms the existence of a minimum in reflectivity that depends on the magnetic field at the cutoff, as expected from mode conversion physics, giving confidence in the feasibility of the diagnostic. The proposed reflectometric approach is expected to yield superior signal-to-noise ratio and to access wider ranges of density and magnetic field, compared with related radiometric techniques that require the plasma to emit electron Bernstein waves. Due to computational limitations, frequencies of 10-20 GHz were considered in this initial study. Frequencies above the edge electron-cyclotron frequency (f > 28 GHz here) would be preferable for the experiment, because the upper hybrid resonance and right cutoff would lie in the plasma, and would help separate the O-mode of interest from spurious X-waves.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determining velocity of detonation using high-resolution time domain reflectometry

Two methods are presented to make measurements of the length of a coaxial cable with submillimeter and submicrosecond accuracy. If the cable is destroyed by the passage of a strong shock, for instance, from the detonation of an explosive, a measure of the phase velocity of the detonation (VOD) can be obtained with high accuracy (≈0.25%). The first method introduces a series of short Gaussian electrical pulses (<300 ps) into the cable that reflect off the cable end and are compared to the time of the original outgoing pulse by using a fast digitizer (100 gigasamples per second). By curve fitting a Gaussian form to the outgoing and reflected pulses, a measurement of the cable length can be made with subsample accuracy. So, as long as the pulses do not overlap, a large number may be present in the cable at any time allowing pulse repetition rates of 40–135 MHz depending on the cable length. Averaging allows accurate VOD measurements to be made that are comparable with the best traditional techniques. The second method replaces the pulser with a wide-spectrum (0.1–10 GHz) amplified random noise source. A similar setup and digitizer are used before autocorrelating short (80–160 ns) subsamples of the total waveform to measure the reflected delay time. That is, a smaller amplitude version of the original waveform appears time shifted by twice the transit time in the cable and this time is estimated via autocorrelation. The advantage of this method is that a new subsample needs only to be selected from a time increment in which new spectral information is present for a new measure of the length to be made. In this manner, many more length estimates can be averaged to establish the VOD than with the Gaussian approach. As a result, a detailed description of the implementation of both methods is presented together with an example of the type of data collected and limitations found.

47 OTHER INSTRUMENTATION↗

Polarisation reflectometry of anisotropic optical fibres

Anisotropic, polarisation-maintaining fibres have been studied using a reflectometer and integrated optic polariser. Linearly polarised pulses were launched into the fibre under test at different angles between their plane of polarisation and the main optical axis of the fibre. A special procedure for the correlation analysis of these reflectograms is developed to enhance the reliability of the information about the longitudinal optical uniformity of anisotropic fibres. (optical fibres and fibreoptic sensors)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Precision loss measurements in short lengths of optical fibre by reflectometry without using Rayleigh scattering

To improve accuracy of light attenuation measurements in optical fibres, especially in short ones, tens and hundreds of metres in length, we propose rejecting a conventional reflectometric approach based on Rayleigh scattering intensity measurements. To this end, we propose for the first time the use of boson peaks in Raman scattering, which, on the one hand, produce no interference effects and no related noise in reflectograms, and, on the other, lie within the C-band. Even at a fibre length as short as 50 m, the attenuation measurement error does not exceed 0.002 dB km{sup −1}. We demonstrate the possibility of compensating for the temperature variation of boson peak intensity by concurrently obtaining a reflectogram for the anti-Stokes line of the fundamental Raman band. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Assessment of the degree of hydration of ocular surface tissues using THz reflectometry

Using the effective medium model, the complex permittivity of the ocular surface system in the THz frequency range is considered. The penetration depth of THz radiation and the sensitivity of the reflected component to the dynamics of evaporation of the tear film are discussed. The results of in vivo experiments aimed to determine the reflection coefficient of the ocular surface using continuous THz reflectometers are well described using the developed model. (paper)

36 MATERIALS SCIENCE↗

Feasibility of study magnetic proximity effects in bilayer 'superconductor/ferromagnet' using waveguide-enhanced polarized neutron reflectometry

A resonant enhancement of the neutron standing waves is proposed to use in order to increase the magnetic neutron scattering from a 'superconductor/ferromagnet' (S/F) bilayer. The model calculations show that usage of this effect allows to increase the magnetic scattering intensity by factor of hundreds. Aspects related to the growth procedure (order of deposition, roughness of the layers etc.) as well as experimental conditions (resolution, polarization of the neutron beam, background etc) are also discussed. Collected experimental data for the S/F heterostructure Cu(32 nm)/V(40 nm)/Fe(1 nm)/MgO confirmed the presence of a resonant 60-fold amplification of the magnetic scattering.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Time-odd correlation in a neutron reflectometry experiment

We find that neutron transmission of magnetic systems with the noncollinear magnetization contains a time-odd correlation. The neutron reflection from such a system violates detailed balance. Time-odd correlation is shown to violate T-invariance even in the presence of an irreversibly produced by losses and described by the imaginary part in the neutron-matter interaction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radio Frequency Field Programable Gate Array Implementation of Reflectometry Cable Monitoring

PNNL has developed an innovative cable testing system that leverages the Xilinx RF System-on-Chip (RFSoC) technology to create a more flexible and capable measurement tool than traditional approaches. The architecture is designed on the ZCU111 development board and takes advantage of the high-speed digital to analog converters (DAC) and analog to digital converters (ADC) to generate and capture digitally synthesized waveforms. The platform allows engineers to easily adjust power, frequency, duration and modulation on the fly rather than being locked into fixed hardware configurations

Tedeschi, Jonathan [Pacific Northwest National Lab↗