Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reference cells”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

DETAIL Component Scaling and Methodology Comparison

The purpose of this study was to develop a process to convert input signals from one facility into another by reflecting geometric and environmental settings. The Dynamic Energy Transport and Integration Laboratory (DETAIL) is a research facility in development. Its aim is to emulate the daily interactions among power production industry systems and receive real-time data from those systems as inputs. To convert signals and ensure that the temporal sequences and magnitudes reflect laboratory settings, the ability to scale and project data is essential. To demonstrate this ability, Dynamical System Scaling (DSS) and Hierarchical Two-Tiered Scaling (H2TS) (methodologies that enable systems to scale and project or extrapolate data sets to desired environments while conserving the observed behavior based on first principles) were applied to DETAIL’s thermocline thermal storage system in the Thermal Energy Distribution System (TEDS) facility and solid-oxide electrolysis cell in the High Temperature Hydrogen Electrolysis (HTHE) facility. Both thermocline and electrolysis cell systems were successfully scaled, and test cases were conducted to generate a doubly accelerated energy charge and discharge in reference to past experimental data from the facilities. The research results represented a case for the thermocline system that required signals to be accelerated without altering the stored energy. To enhance the quality of the accelerated data, error propagation analyses were conducted on DSS post-processing terms to determine the consequences of raw-data-associated errors.

08 HYDROGEN↗

Assessment of human nuclear and mitochondrial DNA qPCR assays for quantification accuracy utilizing NIST SRM 2372a

In forensic DNA casework, a highly accurate real-time quantitative polymerase chain reaction (qPCR) assay is recommended per the Scientific Working Group on DNA Analysis Methods (SWGDAM) (SWGDAM Validation Guidelines for DNA Analysis Methods [1]) to determine whether a DNA sample is of sufficient quantity and robust quality to move forward with downstream short tandem repeats (STR) or sequencing analyses. Most of these assays rely on a standard curve, referred to herein and traditionally as absolute qPCR, in which an unknown is compared, relative to that curve. However, one fundamental issue with absolute qPCR is the quantifiable concentration of commercial assay standards can vary depending on (1) origin, i.e., whether from a cell line or a human subject, (2) supplier, (3) lot number, (4) shipping method, etc. In 2018, the National Institute for Standards and Technology (NIST) released a human DNA standard reference material for evaluating qPCR quantification standards, Standard Reference Material (SRM) 2372a, Romsos et al. (2018) [2] which contains three well-characterized human genomic DNA samples: Component A) a single male1 donor, Component B) a single female 1 donor, and Component C) a 1:3 male 2 :female 2 donor, each with certification data for nDNA and informational mitochondrial DNA(mtDNA)/nuclear DNA (nDNA) ratio data. The SRM 2372a was used to assess four qPCR assays: (1) Quantifiler Trio (Thermo Fisher Scientific, Waltham, MA) for nDNA quantification, (2) NovaQUANT (EMD Millipore Corporation, San Diego, CA) for nDNA and mtDNA quantification, (3) a custom duplex mtDNA assay, and (4) a custom triplex mtDNA assay. Additionally, extracts from eighteen (18) skeletal remains were tested with the latter three assays for concordance of DNA concentration and with assays (2) and (3), for the degradation state. Our assessment revealed that an accurate, efficient, and reproducible qPCR assay is dependent on (1) the quality and reliability of the DNA standard, (2) the qPCR chemistry, and (3) the specific primers, and probes (if applicable), used in an assay. Finally, our findings indicate qPCR assays may not always quantify as expected and that performance of each lot should be verified using a well-characterized DNA standard such as the NIST SRM 2372a and adjusted if warranted.

59 BASIC BIOLOGICAL SCIENCES↗

Exploring Electrode-Level State-of-Charge and State-of-Health Dynamics in Lithium-Ion Battery Cells: Modeling and Experimental Identification

A computationally efficient model serves as a critical prerequisite for battery performance analysis and advanced battery management algorithm design. Although battery models that capture cell-level behavior have been widely explored in existing literature, electrode-level battery models have received much lesser attention till to date. However, such electrode-level models can significantly increase battery performance and life by enabling electrode-level health-conscious control. Such electrode-level control can effectively expand usable energy and power limits of the battery cells by utilizing the knowledge of individual electrodes' charge and health. In this context, this paper presents a comprehensive battery model developed with a reference electrode insertion that captures (i) electrode-level charge/discharge dynamics, (ii) stoichiometric and temporal dependencies of electrode-level resistances, (iii) solid electrolyte interface (SEI) layer growth as key degradation phenomenon, and (iv) capacity fade and resistance rise in each electrode due to nominal battery aging. The proposed model is identified, and a preliminary validation is performed utilizing terminal voltage and negative electrode potential data collected from a pouch cell under one continuous cycling and accelerated aging conditions where the cell experienced 14% capacity loss.

aging↗

In situ Raman investigation of Dy complexation in Cl-bearing aqueous solutions at 20–300 °C

Raman spectroscopy provides a versatile tool for in situ characterization of aqueous rare earth elements (REE) speciation at the molecular level. Complexation of REE with ligands such as Cl – and OH – is of particular interest for understanding the mobility of REE in NaCl-bearing hydrothermal fluids responsible for enriching REE to economic levels in nature. Raman spectroscopic studies of REE speciation in Cl-bearing aqueous fluids are primarily conducted at ambient temperature, whereas natural systems indicate temperatures of >100–600 °C. In this study, the speciation of Dy in acidic chloride-bearing hydrothermal solutions was investigated using confocal Raman spectroscopy with a new capillary Raman heating stage at 20–300 °C. Background solutions (pure water, NaCl-solutions) and solutions with 0.14–1.8 mol kg –1 dissolved DyCl 3 were sealed in quartz capillary cells. Comparison of the spectra for Dy chloride solutions with those for background solutions and the spectra for reference Dy-bearing solids was used to identify Raman bands specific to Dy–O and Dy–Cl bonds. The Raman band for the Dy–O stretching mode of hydrated Dy 3+ aqua ions was measured at 365–384 cm –1 and a Raman band for the Dy–Cl stretching modes of Dy chloride complexes was measured near 240 cm –1 . The Dy–O band decreases systematically with temperature, whereas the Dy–Cl band systematically increases, indicating a systematic increase in the stability of Dy chloride complexes with temperature. Here, this study provides the framework for expanding the use of in situ Raman spectroscopy to investigate the speciation of REE in aqueous solutions to hydrothermal conditions.

58 GEOSCIENCES↗

Multi-Sensor Optimal Motion Planning for Radiological Contamination Surveys by Using Prediction-Difference Maps

Distributed and networked mobile sensor platforms using unmanned aerial and/or ground vehicles to survey areas of interest offer a safer and more efficient method for radiological contamination mapping; however, most applications rely on uniformly sweeping of the area in a raster-type motion without utilizing the information available in a dynamic sense. We have developed a fully autonomous optimal motion planning procedure for networks with two or more mobile sensors. The procedure utilizes well-established concepts of Gaussian processes in combination with control laws based on centroidal Voronoi tessellations to achieve optimal next-iteration sensor movements. A new method of informing optimal motion planning is proposed, whereby the absolute difference between the prior and current full-map prediction, referred to as the prediction-difference map, is used as the spatial density function within each Voronoi cell, providing immediate and iterative feedback for dynamic use of available information. The Gaussian process regression model used to estimate the contamination in unvisited locations also provides prediction uncertainties, and can be used as a quantitative metric to assess the confidence in the calculated contamination map; these estimates and prediction uncertainties are unavailable for standard uniform survey routines as they can only produce maps in the vicinity of observed locations. We present through simulation the achievable performance gains from using this new method by directly comparing to a uniform survey method. Results show that using the prediction-difference maps to inform motion planning procedures offers a faster rate of producing an accurate and convergent map relative to a uniform survey route.

47 OTHER INSTRUMENTATION↗

Global Geo-processed Data of Aquifer Properties by 0.5° Grid, Country and Water Basins

This repository of global hydrogeologic datasets contains aquifer properties on 0.5° scale, including depth to groundwater (Fan et al., 2013), aquifer thickness (de Graaf et al., 2015), WHYMap aquifer classes (Richts et al., 2011), recharge (Döll and Fiedler, 2008; Gleeson et al., 2016), lakes (Messager et al., 2016), porosity and permeability (Gleeson et al., 2014), digitized and geo-processed from their respective sources. Globally gridded aquifer properties could be used independently to estimate global groundwater availability or used as critical inputs to the superwell model to simulate groundwater extraction and provide estimates of pumped volumes and unit costs under user-specific scenarios. Key resources related to this data are: Niazi, H., Ferencz, S. B., Graham, N. T., Yoon, J., Wild, T. B., Hejazi, M., Watson, D. J., & Vernon, C. R. (2025). Long-term hydro-economic analysis tool for evaluating global groundwater cost and supply: Superwell v1.1. Geoscientific Model Development, 18(5), 1737-1767. https://doi.org/10.5194/gmd-18-1737-2025 superwell model repository which uses this data to simulate groundwater extraction and provides estimates of the global extractable volumes and unit-costs ($/km3) of accessible groundwater production under user-specified extraction scenarios. Repository Overview Main output: aquifer_properties_rec.csv contains all processed outputs, including aquifer properties like porosity, permeability, recharge, lake areas, aquifer thickness, and depth to groundwater. shapefiles.zip: contains all digitized GIS databases and shapefile for all aquifer properties prep_inputs.R and prep_inputs_recharge_lakes.R: R scripts that process the shapefiles to produce the aquifer_properties_rec.csv file plot_inputs.R: R script for plotting the maps and conducting preliminary analysis on the available groundwater volume basin_to_country_mapping.csv, basin_country_region_mapping.csv and continent_county_mapping.csv provide the mapping between continents, 32 energy-economic macro regions, countries, and water basins for post-processing aquifer_properties_rec.csv Maps: Each map visualizes the spatial distribution of one of the aquifer properties across the globe map_in_Porosity.png map_in_Permeability.png map_in_Aquifer_thickness.png map_in_Depth_to_water.png map_in_Recharge.png map_in_Grid_area_km.png map_in_Lake_area_km.png map_in_WHYClass.png Sample inputs sample_inputs.py: this script samples inputs from the aquifer_properties_rec dataset, ensuring the sampled and original inputs maintain the same distributions sampled_data_100.csv contains 100 sampled data points and sampled_data_100.png compares their distributions Dataset Overview The main outputs are consolidated in a comprehensive aquifer_properties_rec.csv file and include the following fields: GridCellID: Unique identifier for each (roughly 0.5°) grid cell Continent: Continent name Country: Country name GCAM_basin_ID: Identifier for GCAM hydrologic basin Basin_long_name: Full name of the basin WHYClass: Hydrogeologic classification based on WHYMap aquifer classes (Richts et al., 2011) Porosity: Soil porosity (%) (Gleeson et al., 2014) Permeability: Soil permeability (in square meters; Gleeson et al., 2014) Aquifer_thickness: Thickness of the aquifer (in meters; de Graaf et al., 2015) Depth_to_water: Depth to groundwater (in meters; Fan et al., 2013) Recharge: long-term annual averaged recharge rates (in m/yr; Döll and Fiedler, 2008; Gleeson et al., 2016) Grid_area: Area of the grid cell (in square meters) Lakes_area: Area of inland lakes (in square meters; Messager et al., 2016) Key References The datasets are digitized versions of global hydrogeologic properties from the following key literature sources: Depth to Groundwater: Fan, Y., Li, H., & Miguez-Macho, G. (2013). Global Patterns of Groundwater Table Depth. Science, 339(6122), 940-943. https://doi.org/10.1126/science.1229881 Aquifer Thickness: de Graaf, I. E. M., Sutanudjaja, E. H., van Beek, L. P. H., & Bierkens, M. F. P. (2015). A high-resolution global-scale groundwater model. Hydrol. Earth Syst. Sci., 19(2), 823-837. https://doi.org/10.5194/hess-19-823-2015 Porosity and Permeability: Gleeson, T., Moosdorf, N., Hartmann, J., & van Beek, L. P. H. (2014). A glimpse beneath earth's surface: GLobal HYdrogeology MaPS (GLHYMPS) of permeability and porosity. Geophysical Research Letters, 41(11), 3891-3898. https://doi.org/10.1002/2014GL059856 Aquifer classes: Richts, A., Struckmeier, W. F., & Zaepke, M. (2011). WHYMAP and the Groundwater Resources Map of the World 1:25,000,000. In J. A. A. Jones (Ed.), Sustaining Groundwater Resources: A Critical Element in the Global Water Crisis (pp. 159-173). Springer Netherlands. https://doi.org/10.1007/978-90-481-3426-7_10 Recharge: Döll, P., & Fiedler, K. (2008). Global-scale modeling of groundwater recharge. Hydrol. Earth Syst. Sci., 12(3), 863-885. https://doi.org/10.5194/hess-12-863-2008; Gleeson, T., Befus, K. M., Jasechko, S., Luijendijk, E., & Cardenas, M. B. (2016). The global volume and distribution of modern groundwater. Nature Geoscience, 9(2), 161-167. https://doi.org/10.1038/ngeo2590 Inland Lakes: Messager, M. L., Lehner, B., Grill, G., Nedeva, I., & Schmitt, O. (2016). Estimating the volume and age of water stored in global lakes using a geo-statistical approach. Nature Communications, 7(1), 13603. https://doi.org/10.1038/ncomms13603 Cite as Niazi, H., Watson, D., Hejazi, M., Yonkofski, C., Ferencz, S., Vernon, C., Graham, N., Wild, T., & Yoon, J. (2024). Global Geo-processed Data of Aquifer Properties by 0.5° Grid, Country and Water Basins. MultiSector Dynamics-Living, Intuitive, Value-adding, Environment. https://doi.org/10.57931/2484226 Contact Reach out to Hassan Niazi or open an issue in the superwell repository for questions or suggestions.

aquifer thickness↗

2025 Intern Poster

The Hot Fuel Examination Facility (HFEF) at the Materials and Fuels Complex (MFC) houses the largest U.S. inert atmosphere hot cell for nuclear material research. Key features include the precision gamma scanning (PGS), Fuel Accident Condition Simulator (FACS), Neutron Radiography Reactor (NRAD), and the focus of this project, the Metallograph Loading Cell (MET Cell). The MET Cell performs tests on spent nuclear fuel, such as microhardness testing, microscopy, and neutron radiography. However, the MET Cell’s existing pressure and lighting control systems are outdated and inefficient, with inadequate documentation for system changes over time. This project aims to design a new automated control system for the MET Cell, ensuring longevity (minimum ten years), ease of troubleshooting/repair, and integration into the building monitoring system. The design process addressed challenges such as space restrictions, varied voltages within enclosures, sourcing new components, and security limitations. Compliance with NFPA 70, UL508A, MFC Physical Security, and INL Engineering standards was essential. The project involves repurposing an existing PLC to manage lighting and pressure control using digital and analog signals, simplifying wiring, and ensuring thorough documentation for future reference.

42 - ENGINEERING↗

X-ray microscopy enables multiscale high-resolution 3D imaging of plant cells, tissues, and organs

Capturing complete internal anatomies of plant organs and tissues within their relevant morphological context remains a key challenge in plant science. While plant growth and development are inherently multiscale, conventional light, fluorescence, and electron microscopy platforms are typically limited to imaging of plant microstructure from small flat samples that lack a direct spatial context to, and represent only a small portion of, the relevant plant macrostructures. We demonstrate technical advances with a lab-based X-ray microscope (XRM) that bridge the imaging gap by providing multiscale high-resolution three-dimensional (3D) volumes of intact plant samples from the cell to the whole plant level. Serial imaging of a single sample is shown to provide sub-micron 3D volumes co-registered with lower magnification scans for explicit contextual reference. High-quality 3D volume data from our enhanced methods facilitate sophisticated and effective computational segmentation. Advances in sample preparation make multimodal correlative imaging workflows possible, where a single resin-embedded plant sample is scanned via XRM to generate a 3D cell-level map, and then used to identify and zoom in on sub-cellular regions of interest for high-resolution scanning electron microscopy. In total, we present the methodologies for use of XRM in the multiscale and multimodal analysis of 3D plant features using numerous economically and scientifically important plant systems.

59 BASIC BIOLOGICAL SCIENCES↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis – Simulated Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wind turbine. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen . While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the simulated wind energy profiles, NLR used OpenFAST to simulate a 3.4-MW International Energy Agency (IEA) reference wind turbine. The hour-long wind energy profiles varied over wind turbulence intensity (Class A or Class C) and average wind speed (5, 7, or 9 m/s). To match the power limits of the 1.25-MW electrolyzer and 3.4-MW IEA wind turbine most effectively and to maximize the efficiency of hydrogen production at a given average wind speed, the profiles were sometimes scaled by two times. This means that, in some cases, the experimental setup assumed two 1.25-MW electrolyzers were coupled with the wind turbine, representing a total maximum electrolysis load of 2.5 MW. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}-{average wind speed}-{turbulence class}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “windIEA3.4-5ms-C_2-400.zip” represents the hour-long experiment using the IEA 3.4-MW turbine, subjected to an average wind speed of 5 m/s and Class C wind turbulence, and connected to two 1.25-MW electrolyzers with the power supply set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wind turbine power. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis .

08 HYDROGEN↗

The Exoproteome and Surfaceome of Toxigenic Corynebacterium diphtheriae 1737 and Its Response to Iron Restriction and Growth on Human Hemoglobin

Toxin-producing Corynebacterium diphtheriae strains are the etiological agents of the severe upper respiratory disease, diphtheria. A global phylogenetic analysis revealed that biotype gravis is particularly lethal as it produces diphtheria toxin and a range of other virulence factors, particularly when it encounters low levels of iron at sites of infection. Here, to gain insight into how it colonizes its host, we have identified iron-dependent changes in the exoproteome and surfaceome of C. diphtheriae strain 1737 using a combination of whole-cell fractionation, intact cell surface proteolysis, and quantitative proteomics. In total, we identified 1414 of the predicted 2265 proteins (62%) encoded by its reference genome. For each protein, we quantified its degree of secretion and surface exposure, revealing that exoproteases and hydrolases predominate in the exoproteome, while the surfaceome is enriched with adhesins, particularly DIP2093. Our analysis provides insight into how components in the heme-acquisition system are positioned, showing pronounced surface exposure of the strain-specific ChtA/ChtC paralogues and high secretion of the species-conserved heme-binding HtaA protein, suggesting it functions as a hemophore. Profiling the response of the exoproteome and surfaceome after microbial exposure to human hemoglobin and iron limitation reveals potential virulence factors that may be expressed at sites of infection. Data are available via ProteomeXchange with identifier PXD051674.

cell envelope↗

Specimen-displacement correction for powder X-ray diffraction in Debye–Scherrer geometry with a flat area detector

The effect of small changes in the specimen-to-detector distance on the unit-cell parameters is examined for synchrotron powder diffraction in Debye–Scherrer (transmission) geometry with a flat area detector. An analytical correction equation is proposed to fix the shift in 2θ values due to specimen capillary displacement. This equation does not require the use of an internal reference material, is applied during the Rietveld refinement step, and is analogous to the specimen-displacement correction equations for Bragg–Brentano and curved-detector Debye–Scherrer geometry experiments, but has a different functional form. The 2θ correction equation is compared with another specimen-displacement correction based on the use of an internal reference material in which new integration and calibration parameters of area-detector images are determined. Example data sets showing the effect of a 3.3 mm specimen displacement on the unit-cell parameters for 25°C CeO 2 , including both types of displacement correction, are described. These experiments were performed at powder X-ray diffraction beamlines at the National Synchrotron Light Source II at Brookhaven National Laboratory and the Advanced Photon Source at Argonne National Laboratory.

36 MATERIALS SCIENCE↗

CICE on a C-grid: new momentum, stress, and transport schemes for CICEv6.5

Abstract. This article presents the C-grid implementation of the CICE sea ice model, including the C-grid discretization of the momentum equation, the boundary conditions (BCs), and the modifications to the code required to use the incremental remapping transport scheme. To validate the new C-grid implementation, many numerical experiments were conducted and compared to the B-grid solutions. In idealized experiments, the standard advection method (incremental remapping with C-grid velocities interpolated to the cell corners) leads to a checkerboard pattern. A modal analysis demonstrates that this computational noise originates from the spatial averaging of C-grid velocities at corners. The checkerboard pattern can be eliminated by adjusting the departure regions to match the divergence obtained from the solution of the momentum equation. We refer to this novel approach as the edge flux adjustment (EFA) method. The C-grid discretization with edge flux adjustment allows for transport in channels that are one grid cell wide – a capability that is not possible with the B-grid discretization nor with the C-grid and standard remapping advection. Simulation results match the predicted values of a novel analytical solution for one-grid-cell-wide channels.

Lemieux, Jean-François (ORCID:0000000320845759)↗

Single-shot switching in Tb/Co-multilayer based nanoscale magnetic tunnel junctions

Magnetic tunnel junctions (MTJs) are elementary units of magnetic memory devices. For high-speed and low-power data storage and processing applications, fast reversal of the magnetization by an ultrashort laser pulse is extremely important. Here we demonstrate single-shot switching of Tb/Co-multilayer based nanoscale MTJs by combining the optical writing and the electrical read-out methods. A 90-fs-long laser pulse switches the magnetization of the storage layer (SL). The change in the tunneling magnetoresistance (TMR) between the SL and a reference layer (RL) is probed electrically across the oxide barrier. Single-shot switching is demonstrated by varying the cell diameter from 300 nm to 20 nm. The anisotropy, magnetostatic coupling, and switching probability exhibit cell-size dependence. By suitable association of laser fluence and magnetic field, successive commutation between high-resistance and low-resistance states is achieved. The nature of the magnetization reversal of both SL and RL in a continuous film is probed with a depth-resolved magneto-optical Kerr effect (MOKE) magnetometry. The ultrafast dynamics in the continuous full-MTJ stack is investigated with the time-resolved pump–probe technique. Our experimental findings provide strong support for the growing interest in ultrafast spintronic devices.

36 MATERIALS SCIENCE↗

Modeling Losses in a Three Electrode System Towards Fast Charge Control

In this work we demonstrate the applicability of a versatile separator-reference mounted electrode in a three-electrode setup to accurately capture the primary current pathway in the battery cell during operation, calibrate a porous electrode model to the individual anode and cathode potential signals, and assign the various resistances to electrochemical phenomena in the battery cell. This calibrated electrochemical model is validated using continuous rate discharges associated with highway driving scenarios in an electric vehicle, and in turn utilized to predict the local anode potential and proximity to lithium plating onset. Finally, we demonstrate the strategy associated with utilization of the model to estimate constant anode potential charging during fast charge scenarios at various rates and starting conditions as a future look to fast charge calibration development and controls.

Garrick, Taylor R. (ORCID:0000000322518129)↗

Towards a Unified Low-Cost Flow Plate, Flow-Field, PTL Solution for Proton Exchange Membrane Electrolyzers

Proton exchange membrane (PEM) water electrolysis is a highly efficient method for hydrogen production. Research cells typically consist of one proton exchange membrane, two catalyst layers, two porous transport layers, two flow-field plates, and two endplates. In commercial systems, the machined flow-field plates that are employed in research cells are typically replaced by stamped parts or open mesh material solutions to reduce manufacturing cost at scale. Nonetheless, the cell contains about 8 total interfaces: bipolar plate / flow plate material / porous transport medium / electrode / membrane / electrode / porous transport medium / flow plate material / bipolar plate. All these materials and interfaces need to be optimized for maximum performance and efficiency. Reducing the amount of interfaces by combining individual cell components directly benefits the fabrication cost (by reducing the parts count and the needs for surface coatings) and the electrochemical performance (by reducing ohmic losses). We have designed a novel PEM electrolysis cell with a piece of channeled titanium felt functioning as both the anode flow-field and the PTL, referred to as the channeled diffusion layer (CDL). The pores of the felt facilitate both in-plane and through-plane diffusion, ensuring maximum catalyst utilization while also minimizing mass transport loss. The titanium felt can be mass manufactured with existing stamping and forming methods and is therefore a promising candidate to reduce the capital cost of PEM electrolyzers whilst improving hydrogen production efficiency. Experiments conducted with 3mg IrOx/cm2 loading MEAs have shown a approximately 40% boost in peak current by implementing the CDL design. Low catalyst-loading MEAs are being tested in ongoing experiments and their results will be discussed and compared.

08 HYDROGEN↗

Untargeted GC-MS Metabolic Profiling of Anaerobic Gut Fungi Reveals Putative Terpenoids and Strain-Specific Metabolites

Background/Objectives: Anaerobic gut fungi (Neocallimastigomycota) are biotechnologically relevant, lignocellulose-degrading microbes with under-explored biosynthetic potential for secondary metabolites. Untargeted metabolomic profiling with gas chromatography–mass spectrometry (GC-MS) was applied to two gut fungal strains, Anaeromyces robustus and Caecomyces churrovis, to establish a foundational metabolomic dataset to identify metabolites and provide insights into gut fungal metabolic capabilities. Methods: Gut fungi were cultured anaerobically in rumen-fluid-based media with a soluble substrate (cellobiose), and metabolites were extracted using the Metabolite, Protein, and Lipid Extraction (MPLEx) method, enabling metabolomic and proteomic analysis from the same cell samples. Samples were derivatized and analyzed via GC-MS, followed by compound identification by spectral matching to reference databases, molecular networking, and statistical analyses. Results: Distinct metabolites were identified between A. robustus and C. churrovis, including 2,3-dihydroxyisovaleric acid produced by A. robustus and maltotriitol, maltotriose, and melibiose produced by C. churrovis. C. churrovis may polymerize maltotriose to form an extracellular polysaccharide, like pullulan. GC-MS profiling potentially captured sufficiently volatile products of proteomically detected, putative non-ribosomal peptide synthetases and polyketide synthases of A. robustus and C. churrovis. The triterpene squalene and triterpenoid tetrahymanol were putatively identified in A. robustus and C. churrovis. Their conserved, predicted biosynthetic genes—squalene synthase and squalene tetrahymanol cyclase—were identified in A. robustus, C. churrovis, and other anaerobic gut fungal genera. Conclusions: This study provides a foundational, untargeted metabolomic dataset to unmask gut fungal metabolic pathways and biosynthetic potential and to prioritize future efforts for compound isolation and identification.

Biochemistry & Molecular Biology↗

Mid Infra-Red Laser Sensor for Continuous Sulfur Trioxide Monitoring to Improve Coal-Fired Power Plant Performance during Flexible Operations

During the course of this project, we performed exhaustive research and development of SO3/H2SO4 sensing technology for coal-fired power plant applications (Figure 1). The development culminated in a successful field campaign of a prototype continuous real-time H2SO4 monitor at a coal-fired power plant (TRL 6) accomplishing the primary goal of the project. The developed sensors utilize tunable laser absorption spectroscopy (TLAS) operating in the mid-infrared (Mid-IR) wavelength region, which is the so-called “molecular fingerprint” region. Systems operating in the Mid-IR have orders of magnitude more sensitivity than systems operating at shorter wavelengths, such as near-infrared (NIR). However, NIR systems are more widespread due to more mature supporting technology (e.g., fiber optics, optical components, etc.). In this project, we not only produced a specific Mid-IR sensor, we also advanced Mid-IR sensor technology in general through the development and demonstration of such supporting technology. In this project, we also developed proprietary broad tuning lasers enabling the ability to effectively measure SO3, H2SO4, H2O, and SO2. Different molecular species have unique spectral signatures that can be probed with lasers operating at different wavelengths. Standard TLAS uses relatively narrow wavelength tuning distributed feedback (DFB) lasers, which can typically only target a single species with narrow features, and are not appropriate for species with broad features, such as SO3 or H2SO4. In contrast, by developing unique, broad-tuning laser technology, we were able to measure these species, as well as SO2 and H2O simultaneously. Furthermore, to enable real-time analysis at a power plant, we modified a commercially available heated gas cell to operate in the Mid-IR wavelength range and fiber coupled the lasers to enable remote delivery of the beams. To generate reference data (library spectra), our collaborators at the University of California Irvine (UCI) developed a catalytic SO3 generation facility. It is worth mentioning that representative H2SO4 and SO3 Mid-IR spectra are not a part of any publicly available database and the data generated under this project is a valuable resource in and of itself. In addition, based on the UCI study we determined that detection of SO3 is complicated by the very strong SO2 absorption. For that reason, we concentrated on H2SO4 detection. Since SO3 and H2SO4 exist in a flue gas in a state of equilibrium, which depends on temperature and humidity, by measuring water concentration and controlling the temperature of the gas cell, we developed an approach to determine SO3 concentration from the H2SO4 measurement. During the development phase of the project, we performed three testing campaigns at our collaborator’s FERCo flue gas facility with conditions representative of the coal-fired power plant (~ 40ppm SO3, 1700ppm to 2800 ppm SO2, 10% water) with the exception of particulate matter. After three test campaigns at FERCo we performed field testing at Harrison Power Station. The final system was mounted on a duct and measured H2SO4, SO2 and water. The tests were highly successful with a demonstrated real-time H2SO4 precision of 1 ppm with a 1 second update. Our collaborators at EPRI conducted an industry survey and determined that there is a very high interest for the SO3/H2SO4 monitoring in the power generation industry as well as in heavy industries in general. Furthermore, work performed by OptoKnowledge beyond the scope of this project under a synergistic DOE SBIR determined another approach to SO3 detection. We applied for Phase II on this SBIR for development a of versatile SO3/H2SO4 sensor but were not selected. We are currently looking for another opportunity to leverage all the technological advancements produced by this project including but not limited to the flue gas facility at UCI, the hardware and software developed, and relationships with FERCo, EPRI CEMTEK, and Harrison Station.

01 COAL, LIGNITE, AND PEAT↗

Improving Electronic Conductivity of Layered Oxides through the Formation of Two-Dimensional Heterointerface for Intercalation Batteries

Synthetic strategies for the improvement in electronic conductivities and electrochemical stabilities of transition metal oxide cathodes, which are limiting factors in the performance of commercial intercalation batteries, are required for next-generation, high-performance battery systems. Furthermore, the chemical preintercalation approach, consisting of a combined sequence of a sol–gel process, extended aging, and a hydrothermal treatment, is a versatile, wet synthesis technique that allows for the incorporation of a polar species between the layers of transition metal oxides. Here, formation of a layered 2D δ-C x V 2 O 5 · n H 2 O heterostructure occurs via chemical preintercalation of dopamine molecules between bilayers of vanadium oxide followed by the hydrothermal treatment of the precipitate, leading to carbonization of the organic molecules. The presence of carbon layers within the structure has been confirmed via a combined analysis of scanning electron microscopy, X-ray diffraction, thermogravimetric analysis, Raman spectroscopy, X-ray photoelectron spectroscopy, electrochemical impedance spectroscopy, four-probe conductivity measurements, and scanning transmission electron microscopy characterization. 2D δ-C x V 2 O 5 · n H 2 O heterostructure electrodes demonstrated significantly improved electrochemical performance, particularly at higher current densities, in Li-ion cells. The heterostructure electrodes exhibited 75% of the capacity retention when the current was changed from 20 mA g –1 (206 mAh g –1 ) to 300 mA g –1 (155 mAh g –1 ), while the reference δ-V 2 O 5 · n H 2 O electrodes exhibited only 10% capacity retention in the same experiment. Remarkably, 2D δ-C x V 2 O 5 · n H 2 O heterostructure electrodes demonstrated significantly improved capacity retention (94% after 30 cycles) for bilayered vanadium oxide electrodes in Li-ion cells during galvanostatic cycling at 20 mA g –1 . The improved electrochemical performance, in both extended cycling and rate capability studies, of the 2D δ-C x V 2 O 5 · n H 2 O heterostructure electrodes in the Li-ion system is ascribed to the intermittent formation of carbon layers within the bilayered structure, which leads to increased electronic conductivity and improved structural stability of the heterostructure compared to the reference δ-V 2 O 5 · n H 2 O electrodes.

25 ENERGY STORAGE↗