Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “readout systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

The Trigger System of ICARUS-T600 Detector at Fermilab

The ICARUS-T600 liquid argon (LAr) time projection chamber (TPC) detector is currently deployed as a far detector of the Short Baseline Neutrino (SBN) program at Fermilab (USA) to search for a possible LSND-like sterile neutrino signal at $\Deltam^2 \approx 1eV^2$ with the Booster (BNB) and Main Injector (NuMI) Neutrino Beams. A global physical event rate of $\approx 0.6$ Hz, including the genuine neutrino interactions in LAr, beam halos and cosmic interactions inside the proton pulse time windows, is expected, roughly corresponding to $\approx 4$ PB of data for the total 6.6 $10^{20}$ pot exposure if the full ICARUS-T600 detector is readout ($\approx 200$ MB event size). The designed trigger system described here will collect the genuine neutrino interactions with a $\approx 95$\% expected efficiency.

Copello, S. [INFN, Pavia]↗

Noise Erasure in Quantum-Limited Current Amplifiers

Superconducting quantum interference devices (SQUIDs) are extraordinarily sensitive to magnetic flux and thus make excellent current amplifiers for cryogenic applications. One such application of high interest to Sandia is the set-up and state read-out of quantum dot based qubits, where a qubit state is read out from a short current pulse (microseconds to milliseconds long) of approximately 100 pA, a signal that is easily corrupted by noise in the environment. A Parametric SQUID Amplifier can be high bandwidth (in the GHz range), low power dissipation (less than 1pW), and can be easily incorporated into multi-qubit systems. In this SAIL LDRD, we will characterize the noise performance of the parametric amplifier front end -- the SQUID -- in an architecture specific to current readout for spin qubits. Noise is a key metric in amplification, and identifying noise sources will allow us to optimize the system to reduce its effects, resulting in higher fidelity readout. This effort represents a critical step in creating the building blocks of a high speed, low power, parametric SQUID current amplifier that will be needed in the near term as quantum systems with many qubits begin to come on line in the next few years.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observation of Synchronization between Two Quantum van der Pol Oscillators in Trapped Ions

Synchronization is a hallmark of collective behavior that emerges when nonlinear systems interact, spanning scales from mechanical oscillators to planetary orbits. As a universal phenomenon, it underpins the study of complex systems and has far-reaching technological implications. While classical synchronization has a long and rich history, it has not been observed experimentally between multiple quantum limit-cycle oscillators despite a decade of theoretical investigations. We realize synchronization between two quantum van der Pol oscillators by engineering dissipation in a mixed-isotope trapped-ion quantum simulator. The synchronized state is encoded in a fixed relative phase between the oscillators that is inaccessible to individual measurements and revealed only through joint readout of both oscillators, in stark contrast to the system in the (deterministic) classical limit where synchronization can be observed via individual phase measurements. We further show that the relative phase can be precisely controlled and that the chain of two oscillators can synchronize to an external field, suggesting applications in sensing. Our results provide a promising pathway for studying more complex synchronized quantum dynamics beyond two oscillators, where a theoretical treatment becomes increasingly challenging, and it remains to be understood whether genuinely quantum features persist in such cases.

Liu, Jiarui↗

Anomalous Loss Reduction Below Two‐Level System Saturation in Aluminum Superconducting Resonators

Superconducting resonators are widely used in many applications such as qubit readout for quantum computing, and kinetic inductance detectors. These resonators are susceptible to numerous loss and noise mechanisms, especially the dissipation due to two-level systems (TLS) which become the dominant source of loss in the few-photon and low temperature regime. In this study, capacitively-coupled aluminum half-wavelength coplanar waveguide resonators are investigated. Surprisingly, the loss of the resonators is observed to decrease with a lowering temperature at low excitation powers and temperatures below the TLS saturation. This behavior is attributed to the reduction of the TLS resonant response bandwidth with decreasing temperature and power to below the detuning between the TLS and the resonant photon frequency in a discrete ensemble of TLS. When response bandwidths of TLS are smaller than their detunings from the resonance, the resonant response and thus the loss is reduced. At higher excitation powers, the loss follows a logarithmic power dependence, consistent with predictions from the generalized tunneling model (GTM). A model combining the discrete TLS ensemble with the GTM is proposed and matches the temperature and power dependence of the measured internal loss of the resonator with reasonable parameters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Using PyBioNetFit to leverage qualitative and quantitative data in biological model parameterization and uncertainty quantification

Data generated in studies of cellular regulatory systems are often qualitative. For example, measurements of signaling readouts in the presence and absence of mutations may reveal a rank ordering of responses across conditions but not the precise extents of mutation-induced differences. Qualitative data are often ignored by mathematical modelers or are considered in an ad hoc manner, as in the study of Kocieniewski and Lipniacki (2013) [Phys Biol 10: 035006], which was focused on the roles of MEK isoforms in ERK activation. In this earlier study, model parameter values were tuned manually to obtain consistency with a combination of qualitative and quantitative data. This approach is not reproducible, nor does it provide insights into parametric or prediction uncertainties. Here, starting from the same data and the same ordinary differential equation (ODE) model structure, we generate formalized statements of qualitative observations, making these observations more reusable, and we improve the model parameterization procedure by applying a systematic and automated approach enabled by the software package PyBioNetFit. We also demonstrate uncertainty quantification (UQ), which was absent in the original study. Our results show that PyBioNetFit enables qualitative data to be leveraged, together with quantitative data, in parameterization of systems biology models and facilitates UQ. These capabilities are important for reliable estimation of model parameters and model analyses in studies of cellular regulatory systems and reproducibility.

59 BASIC BIOLOGICAL SCIENCES↗

The New Small Wheel electronics

The increase in luminosity, and consequent higher backgrounds, of the LHC upgrades require improved rejection of fake tracks in the forward region of the ATLAS Muon Spectrometer. The New Small Wheel upgrade of the Muon Spectrometer aims to reduce the large background of fake triggers from track segments that don't originate from the interaction point. The New Small Wheel employs two detector technologies, the resistive strip Micromegas detectors and the “small” Thin Gap Chambers, with a total of 2.45 million electrodes to be sensed. The two technologies require the design of a complex electronics system given that it consists of two different detector technologies and is required to provide both precision readout and a fast trigger. It will operate in a high background radiation region up to about 20 kHz/cm 2 at the expected HL-LHC luminosity of $\mathcal{L}$= 7.5 × 10 34 cm -2 s -1 . The architecture of the system is strongly defined by the GBTx data aggregation ASIC, the newly-introduced FELIX data router and the software based data handler of the ATLAS detector. The electronics complex of this new detector was designed and developed in the last ten years and consists of multiple radiation tolerant Application Specific Integrated Circuits, multiple front-end boards, dense boards with FPGA's and purpose-built Trigger Processor boards within the ATCA standard. The New Small Wheel has been installed in 2021 and is undergoing integration within ATLAS for LHC Run 3. It should operate through the end of Run 4 (December 2032). In this manuscript, the overall design of the New Small Wheel electronics is presented.

47 OTHER INSTRUMENTATION↗

The DUNE DAQ Application Framework

The Deep Underground Neutrino Experiment (DUNE) is a next-generation neutrino experiment that will probe the properties of these elusive particles with unparalleled precision. It will also act as an observatory for neutrino bursts caused by nearby supernovae, in the event that one occurs while the experiment is in operation. Given these goals, the DUNE trigger and DAQ system must be able to maintain extremely high uptime and provide a path for full readout of the detectors for very long times (up to 100s). To achieve these ends, we have designed the DUNE DAQ system around a flexible “application framework”, which provides a modular interface for specific tasks while handling the interconnections between them. The application framework collects modules into applications which can then be interacted with as units by the control, configuration and monitoring systems. One of the key features of the framework is its communications abstraction layer, which allows for modules to interact with both internal queues and external network connections with a single transport-agnostic interface. We will report on the architecture and features of the framework.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The DUNE-DAQ Application Framework

The deep underground neutrino experiment (DUNE) is a next-generation neutrino experiment that will probe the properties of these elusive particles with unparalleled precision. It will also act as an observatory for neutrino bursts caused by nearby supernovae, in the event that one occurs, while the experiment is in operation. Given these goals, the DUNE trigger and DAQ system must be able to maintain extremely high uptime and provide a path for full readout of the detectors for very long times (up to 100 s). To achieve these ends, we have designed the DUNE DAQ system around a flexible “application framework,” which provides a modular interface for specific tasks while handling the interconnections between them. The application framework collects modules into applications, which can then be interacted with as units by the control, configuration, and monitoring systems. One of the key features of the framework is its communication abstraction layer, which allows for modules to interact with both internal queues and external network connections with a single transport-agnostic interface. We will report on the architecture and features of the framework.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superconducting Levitated Detector of Gravitational Waves

A magnetically levitated mass couples to gravity and can act as an effective gravitational wave detector. We show that a superconducting sphere levitated in a quadrupolar magnetic field, when excited by a gravitational wave, will produce magnetic field fluctuations that can be read out using a flux tunable microwave resonator. With a readout operating at the standard quantum limit, such a system could achieve broadband strain noise sensitivity of h ≲ 10 − 20 / Hz for frequencies of 1 kHz–1 MHz, opening new corridors for astrophysical probes of new physics. Published by the American Physical Society 2025

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The ETROC2 prototype for CMS MTD Endcap Timing Layer (ETL) upgrade

The Endcap Timing ReadOut Chip (ETROC) is designed to process LGAD signals with time resolution down to about 40-50ps per hit. The ETROC2 is the first full size (16x16) prototype design with the front-end based on and scaled up from the ETROC1 (4x4). The readout designs at pixel and global level and the system interfaces are all new and are compatible with the final chip specifications in terms of functionality. The ETROC2 is intended as a learning chip, as a stepstone to the ETROC3 which is intended as the pre-production design. The ETROC2 design and test results will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The ETROC2 prototype for CMS MTD Endcap Timing Layer (ETL) upgrade

The ETROC2 prototype for CMS MTD Endcap Timing Layer (ETL) upgrade 520__ $$aThe Endcap Timing ReadOut Chip (ETROC) is designed to process LGAD signals with time resolution down to about 40-50ps per hit. The ETROC2 is the first full size (16x16) prototype design with the front-end based on and scaled up from the ETROC1 (4x4). The readout designs at pixel and global level and the system interfaces are all new and are compatible with the final chip specifications in terms of functionality. The ETROC2 is intended as a learning chip, as a stepstone to the ETROC3 which is intended as the pre-production design. The ETROC2 design and test results will be presented.

Gong, Datao↗

A blessing in disguise : Characterisations of ProtoDUNE photon showers for neutrino measurements in DUNE

There are few areas of particle physics as open to new discoveries as the neutrino sector. Although these particles are among the most abundant in the universe, their weak coupling to ordinary matter makes them a challenge to study. The Deep Underground Neutrino Experiment (DUNE) is an upcoming precision experiment in neutrino physics planned to be built between Illinois and South Dakota in the US. The most powerful neutrino beam in the world will be aimed at the largest liquid argon time projection chamber in the world through 1300 km of solid rock. In order to prototype this detector, a scale model was constructed and operated at CERN in 2018 called ProtoDUNE. This thesis presents three studies performed on this detector. The first concerns the readout of detector data by the FELIX data acquisition system, as well as compression studies performed on the same data. The second study concerns the identification of photons created in neutral pion decay, which form a major background to neutrino-produced electrons. The distinction between electrons and photons is based on the differing energy deposition in the initial part of the particle showers they produce. The third study concerns the energy reconstruction of particle showers in the detector. Although photon showers created from neutral pion decay are a major background to the eventual neutrino signal, they have a known energy profile and can thus be used to calibrate the energy reconstruction of particle showers in general, a vital requirement for DUNE’s physics goals.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The ETROC2 prototype for CMS MTD Endcap Timing Layer (ETL) upgrade

The Endcap Timing ReadOut Chip (ETROC) is designed to process LGAD signals with time resolution down to about 40-50ps per hit. The ETROC2 is the first full size (16x16) prototype design with the front-end based on and scaled up from the ETROC1 (4x4). The readout designs at pixel and global level and the system interfaces are all new and are compatible with the final chip specifications in terms of functionality. The ETROC2 is intended as a learning chip, as a stepstone to the ETROC3 which is intended as the pre-production design. The ETROC2 design and test results will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Blessing in Disguise -- Characterisations of ProtoDUNE photon showers for neutrino measurements in DUNE

This thesis presents three studies performed on ProtoDUNE, a prototype liquid argon time projection chamber for the Deep Underground Neutrino Experiment (DUNE). The first study concerns the readout of detector data by the FELIX data acquisition system, as well as compression studies performed on the same data. The second study concerns the identification of photons created in neutral pion decay, which form a major background to neutrino-produced electrons. The distinction between electrons and photons is based on the differing energy deposition in the initial part of the particle showers they produce. The third study concerns the energy reconstruction of these particle showers in the detector. They have a known energy profile and can thus be used to calibrate the energy reconstruction of particle showers in general, a vital requirement for DUNE’s physics goals.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Robustness of the smartpixels classifier for different simulated sensor geometries and non-ideal detector conditions

Pixel tracking detectors at upcoming collider experiments will see unprecedented charged-particle densities. Real-time data reduction on the detector will enable higher granularity and faster readout, possibly enabling the use of the pixel detector in high-rate online event selection, such as the ATLAS or CMS first-level trigger systems. This data reduction can be accomplished with a neural network (NN) in the readout chip bonded with the sensor that recognizes and rejects tracks with low transverse momentum (p T ) based on the geometrical shape of the charge deposition (“cluster”). To design viable detectors for deployment, the dependence of the NN as a function of the sensor geometry, external magnetic field, irradiation, and noise must be understood. In this paper, we present first studies of the efficiency and data reduction for planar pixel sensors exploring these parameters. For the CMS HL-LHC sensor geometry, we obtain a signal efficiency of (91.9 ± 0.7)% and a data reduction of (29.7 ± 1.0)%. A smaller sensor pitch in the bending direction improves the p T discrimination, but a larger pitch can be partially compensated with detector thickness. Any accumulated radiation damage also changes the cluster shape, reducing the signal efficiency compared to the baseline by approximately 30–60% in absolute terms, but nearly all of the performance can be recovered through retraining of the network and updating the weights. Finally, the impact of noise was investigated, and retraining the network on noise-injected datasets was found to maintain performance within 6% of the baseline network trained and evaluated on noiseless data. •ASIC-compatible track-momentum classifier is robust in realistic detector conditions.•About 90% signal efficiency and 30% data reduction per layer for CMS HL-LHC geometry.•Single-layer signal efficiency increases for smaller pixel pitch or thicker sensors.•Performance with noise or after radiation damage mostly recovered by retraining.

Shekar, Danush [Illinois U., Chicago] (ORCID:00000↗

The QICK (Quantum Instrumentation Control Kit): Readout and control for qubits and detectors

We introduce a Xilinx RF System-on-Chip (RFSoC)-based qubit controller (called the Quantum Instrumentation Control Kit, or QICK for short), which supports the direct synthesis of control pulses with carrier frequencies of up to 6 GHz. The QICK can control multiple qubits or other quantum devices. The QICK consists of a digital board hosting an RFSoC field-programmable gate array, custom firmware, and software and an optional companion custom-designed analog front-end board. We characterize the analog performance of the system as well as its digital latency, important for quantum error correction and feedback protocols. We benchmark the controller by performing standard characterizations of a transmon qubit. We achieve an average gate fidelity of ℱ avg =99.93%. All of the schematics, firmware, and software are open-source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radioxenon Detection for Monitoring Subsurface Nuclear Explosion

The Comprehensive Nuclear-Test-Ban Treaty (CTBT) bans the testing of nuclear weapons anywhere on the earth (atmospheric, surface, underwater and subsurface). Identification of nuclear explosions in the atmosphere, surface, and underwater is relatively straightforward considering a wide range of signatures resulting from such an event. However, for a subsurface explosion, most of the signatures traditionally associated with a nuclear explosion are not readily available. Therefore, the international community has increasingly relied on the atmospheric measurement of noble gases to identify subsurface nuclear weapon explosions. This chapter initially covers the basic principles of subsurface nuclear explosion identification and the importance of detecting radioxenon. This is followed by reviewing some of the early radioxenon detection systems that were developed by research groups around the world in the late 1990s and early 2000s. The detection media employed, results from laboratory and field testing, and some challenges/drawbacks for these systems are detailed. The next section of the chapter is dedicated to innovative detector concepts that have emerged in the past ten to fifteen years using novel detection material, algorithms, and signal readout techniques. The advances achieved in terms of energy resolution, coincidence detection efficiencies, system performance, and the minimum detectable concentration are covered. The final section goes over some of the potential improvements that can be incorporated in the design to enhance detector sensitivity and new detection material that can be explored in the field of radioxenon detection.

Gadey, Harish Reddy↗

Low latency optical-based mode tracking with machine learning deployed on FPGAs on a tokamak

Active feedback control in magnetic confinement fusion devices is desirable to mitigate plasma instabilities and enable robust operation. Optical high-speed cameras provide a powerful, non-invasive diagnostic and can be suitable for these applications. Here, in this study, we process high-speed camera data, at rates exceeding 100 kfps, on in situ field-programmable gate array (FPGA) hardware to track magnetohydrodynamic (MHD) mode evolution and generate control signals in real time. Our system utilizes a convolutional neural network (CNN) model, which predicts the n = 1 MHD mode amplitude and phase using camera images with better accuracy than other tested non-deep-learning-based methods. By implementing this model directly within the standard FPGA readout hardware of the high-speed camera diagnostic, our mode tracking system achieves a total trigger-to-output latency of 17.6 μs and a throughput of up to 120 kfps. This study at the High Beta Tokamak-Extended Pulse (HBT-EP) experiment demonstrates an FPGA-based high-speed camera data acquisition and processing system, enabling application in real-time machine-learning-based tokamak diagnostic and control as well as potential applications in other scientific domains.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗