Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “readout systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

A Normal Incidence X-ray Telescope (NIXT) sounding rocket payload

Work on the High Resolution X-ray (HRX) Detector Program is described. In the laboratory and flight programs, multiple copies of a general purpose set of electronics which control the camera, signal processing and data acquisition, were constructed. A typical system consists of a phosphor convertor, image intensifier, a fiber optics coupler, a charge coupled device (CCD) readout, and a set of camera, signal processing and memory electronics. An initial rocket detector prototype camera was tested in flight and performed perfectly. An advanced prototype detector system was incorporated on another rocket flight, in which a high resolution heterojunction vidicon tube was used as the readout device for the H(alpha) telescope. The camera electronics for this tube were built in-house and included in the flight electronics. Performance of this detector system was 100 percent satisfactory. The laboratory X-ray system for operation on the ground is also described.

Golub, Leon↗

A 90GHz Bolometer Camera Detector System for the Green Bank Telescope

We describe a close-packed, two-dimensional imaging detector system for operation at 90GHz (3.3mm) for the 100 m Green Bank Telescope (GBT) This system will provide high sensitivity (<1mjy in 1s rapid imaging (15'x15' to 250 microJy in 1 hr) at the world's largest steerable aperture. The heart of this camera is an 8x8 close packed, Nyquist-sampled array of superconducting transition edge sensor bolometers. We have designed and are producing a functional superconducting bolometer array system using a monolithic planar architecture and high-speed multiplexed readout electronics. With an NEP of approx. 2.10(exp 17) W/square root Hz, the TES bolometers will provide fast linear sensitive response for high performance imaging. The detectors are read out by and 8x8 time domain SQUID multiplexer. A digital/analog electronics system has been designed to enable read out by SQUID multiplexers. First light for this instrument on the GBT is expected within a year.

Benford, Dominic J.↗

Novel Multiplexing Technique for Detector and Mixer Arrays

Future submillimeter and far-infrared space telescopes will require large-format (many 1000's of elements) imaging detector arrays to perform state-of-the-art astronomical observations. A crucial issue related to a focal plane array is a readout scheme which is compatible with large numbers of cryogenically-cooled (typically < 1 K) detectors elements. When the number of elements becomes of the order of thousands, the physical layout for individual readout amplifiers becomes nearly impossible to realize for practical systems. Another important concern is the large number of wires leading to a 0.1-0.3 K platform. In the case of superconducting transition edge sensors (TES), a scheme for time-division multiplexing of SQUID read-out amplifiers has been recently demonstrated. In this scheme the number of SQUIDs is equal to the number (N) of the detectors, but only one SQUID is turned on at a time. The SQUIDs are connected in series in each column of the array, so the number of wires leading to the amplifiers can be reduced, but it is still of the order of N. Another approach uses a frequency domain multiplexing scheme of the bolometer array. The bolometers are biased with ac currents whose frequencies are individual for each element and are much higher than the bolometer bandwidth. The output signals are connected in series in a summing loop which is coupled to a single SQUID amplifier. The total number of channels depends on the ratio between the SQUID bandwidth and the bolometer bandwidth and can be at least 100 according to the authors. An important concern about this technique is a contribution of the out-of-band Johnson noise which multiplies by factor N(exp 1/2) for each frequency channel. We propose a novel solution for large format arrays based on the Hadamard transform coding technique which requires only one amplifier to read out the entire array of potentially many 1000's of elements and uses approximately 10 wires between the cold stage and room temperature electronics. This can significantly reduce the complexity of the readout circuits.

Karasik, Boris S.↗

Looking at Earth from space: Direct readout from environmental satellites

Direct readout is the capability to acquire information directly from meteorological satellites. Data can be acquired from NASA-developed, National Oceanic and Atmospheric Administration (NOAA)-operated satellites, as well as from other nations' meteorological satellites. By setting up a personal computer-based ground (Earth) station to receive satellite signals, direct readout may be obtained. The electronic satellite signals are displayed as images on the computer screen. The images can display gradients of the Earth's topography and temperature, cloud formations, the flow and direction of winds and water currents, the formation of hurricanes, the occurrence of an eclipse, and a view of Earth's geography. Both visible and infrared images can be obtained. This booklet introduces the satellite systems, ground station configuration, and computer requirements involved in direct readout. Also included are lists of associated resources and vendors.

Source record↗

A 90GHz Bolometer Camera Detector System for the Green

We describe a close-packed, two-dimensional imaging detector system for operation at 90GHz (3.3 mm) for the 100m Green Bank Telescope (GBT). This system will provide high sensitivity (less than 1mJy in 1s) rapid imaging (15'x15' to 150 micron Jy in 1 hr) at the world's largest steerable aperture. The heart of this camera is an 8x8 close-packed, Nyquist-sampled array of superconducting transition edge sensor (TES) bolometers. We have designed and are producing a functional superconducting bolometer array system using a monolithic planar architecture and high-speed multiplexed readout electronics. With an NEP of approximately 2 x 10(exp -17) W/square root of Hz, the TES bolometers will provide fast, linear, sensitive response for high performance imaging. The detectors are read out by an 8x8 time domain SQUID multiplexer. A digital/analog electronics system has been designed to enable read out by SQUID multiplexers. First light for this instrument on the GBT is expected within a year.

Benford, Dominic J.↗

Wearable Wireless Telemetry System for Implantable BioMEMS Sensors

Telemetry systems of a type that have been proposed for the monitoring of physiological functions in humans would include the following subsystems: Surgically implanted or ingested units that would comprise combinations of microelectromechanical systems (MEMS)- based sensors [bioMEMS sensors] and passive radio-frequency (RF) readout circuits that would include miniature loop antennas. Compact radio transceiver units integrated into external garments for wirelessly powering and interrogating the implanted or ingested units. The basic principles of operation of these systems are the same as those of the bioMEMS-sensor-unit/external-RFpowering- and-interrogating-unit systems described in "Printed Multi-Turn Loop Antennas for Biotelemetry" (LEW-17879-1) NASA Tech Briefs, Vol. 31, No. 6 (June 2007), page 48, and in the immediately preceding article, "Hand-Held Units for Short-Range Wireless Biotelemetry" (LEW-17483-1). The differences between what is reported here and what was reported in the cited prior articles lie in proposed design features and a proposed mode of operation. In a specific system of the type now proposed, the sensor unit would comprise mainly a capacitive MEMS pressure sensor located in the annular region of a loop antenna (more specifically, a square spiral inductor/ antenna), all fabricated as an integral unit on a high-resistivity silicon chip. The capacitor electrodes, the spiral inductor/antenna, and the conductor lines interconnecting them would all be made of gold. The dimensions of the sensor unit have been estimated to be about 110.4 mm. The external garment-mounted powering/ interrogating unit would include a multi-turn loop antenna and signal-processing circuits. During operation, this external unit would be positioned in proximity to the implanted or ingested unit to provide for near-field, inductive coupling between the loop antennas, which we have as the primary and secondary windings of an electrical transformer.

Simons, Rainee N.↗

Quasilog scaler

Quasi-logarithmic readout of conventional binary scaler provided by reduced logic system following generalized equations

Weissman, R.↗

Precision pointing thrustor.

A satellite experiment to test the predicted relativistic precession of a gyroscope moving through a gravitational field has been under development at Stanford University for a number of years. The instruments will be located in a liquid helium bath to insure dimensional stability and to permit using superconducting types of circuitry for readout of the gyro orientation. Heat leaks in the system cause the helium to boil and the resultant helium gas is used for attitude control. The principal subject of the paper is the design and experimental evaluation of an electromagnetically actuated differential thrustor which was built and tested at Stanford University. The results are unique because most propulsion systems operate on-off in order to utilize propellant efficiently. In this case, the gas must flow continually to provide cooling, and the requirements are primarily for low power, small volume, and high reliability.

Bull, J. S.↗

Application of a single area array detector for acquistion, tracking and point-ahead in space optical communications

Functions of acquisition, tracking, and point-ahead in space optical communications are being combined into a single system utilizing an area array detector. An analysis is presented of the feasibility concept. The key parameters are: optical power less than 1 pW at 0.86 micrometer, acquisition in less than 30 seconds in an acquisition field of view (FOV) of 1 mrad, tracking with 0.5 microrad rms noise at 1000 Hz update rate, and point ahead transfer function precision of 0.25 microrad over a region of 150 microrad. Currently available array detectors were examined. The most demanding specifications are low output noise, a high detection efficiency, a large number of pixels, and frame rates over 1kHz. A proof of concept (POC) demonstration system is currently being built utilizing the Kodak HS-40 detector (a 128 x 128 photodiode array with a 64 channel CCD readout architecture which can be operated at frame rates as high as 40,000/sec). The POC system implements a windowing scheme and special purpose digital signal processing electronic for matched filter acquisition and tracking algorithms.

Clark, D. L.↗

Application of a single area array detector for acquisition, tracking and point-ahead in space optical communications

Functions of acquisition, tracking, and point-ahead in space optical communications are being combined into a single system utilizing an area array detector. An analysis is presented of the feasibility concept. The key parameters are: optical power less than 1 pW at 0.86 micrometer, acquisition in less than 30 seconds in an acquisition field of view (FOV) of 1 mrad, tracking with 0.5 microrad rms noise at 1000 Hz update rate, and point ahead transfer function precision of 0.25 microrad over a region of 150 microrad. Currently available array detectors were examined. The most demanding specifications are low output noise, a high detection efficiency, a large number of pixels, and frame rates over 1kHz. A proof of concept (POC) demonstration system is currently being built utilizing the Kodak HS-40 detector (a 128 x 128 photodiode array with a 64 channel CCD readout architecture which can be operated at frame rates as high as 40,000/sec). The POC system implements a windowing scheme and special purpose digital signal processing electronic for matched filter acquisition and tracking algorithms.

Clark, D. L.↗

Fiber optic data transmission

The Ohio University Avionics Engineering Center is currently developing a fiber optic data bus transmission and reception system that could eventually replace copper cable connections in airplanes. The original form of the system will transmit information from an encoder to a transponder via a fiber optic cable. An altimeter and an altitude display are connected to a fiber optic transmitter by copper cable. The transmitter converts the altimetry data from nine bit parallel to serial form and send these data through a fiber optic cable to a receiver. The receiver converts the data using a cable similar to that used between the altimeter and display. The transmitting and receiving ends also include a display readout. After completion and ground testing of the data bus, the system will be tested in an airborne environment.

Shreve, Steven T.↗

Circular-scan streak tube with solid-state readout

A circular-scan streak tube designed for use in a laser ranging system is described. Electrostatic focusing is used between the photocathode and a microchannel plate, and electrons from the microchannel plate are proximity focused onto an output phosphor screen. Electron beam deflection is achieved by driving two orthogonal sets of deflection plate assemblies in phase quadrature at a frequency of 200 MHz. The light intensity in the output beam trace is measured by using a circular Reticon array of 720 photodiodes, which is fiber-optically coupled to the output phosphor screen of the tube. Sample measurements of frequency-doubled Nd:YAG laser-pulse waveforms are given. Also the output beamwidth has been measured at the 200-MHz deflection frequency. The results suggest a limiting resolution of 33 psec for the circular-scan streak tube used for these tests.

Johnson, C. B.↗

Slow-scan operation of long linear CCD arrays

Linear CCD arrays used singly or in optically butted assemblies permit practical implementation of long line array systems with 6000 or more picture elements per line with readout rates in excess of 5 MHz. Display and tape recording of slow scan imagery with over 1000 picture elements per line also presents unique challenges. This paper discusses performance results and the operation of 1728-element CCD arrays for generation of high resolution slow scan imagery and some approaches for recording and display of the imagery. The implication of dark current and its control are discussed.

Vicars-Harris, M.↗

Low-light-level integrating video system

System consists of television camera using 25 mm SEC vidicon, low dispersion spectrograph, and digital video image system used for buffer storage of video data during tube readout scanning. Six-bit ADC converts video to digital data which are stored on magnetic tape for future evaluation.

Duncan, B. J.↗

High-Visibility Data Display

Data-monitoring system continuously senses output voltages from transducers and provides large, easy-to-read displays of quantities represented by voltages. Measurements of power-supply voltages and currents, pressures, temperatures, strains, and masses displayed. System intended to operate 24 hours a day, producing uninterrupted readouts of critical parameters.

Slusser, K.↗

Cryogenic optical systems and instruments II; Proceedings of the Meeting, Los Angeles, CA, Jan. 23, 24, 1986

The topics of the present conference encompass cryogenic optical system design considerations, cryogenic instruments and their components, the design and performance of cryogenic dewars for space, and technologies supporting cryogenic systems and instruments. Attention is given to the Space IR Telescope Facility (SIRTF) observatory's design and on-orbit servicing, hardware development for the Gravity Probe-B program, the multiband imaging photometer aboard SIRTF, and the SIRTF wide field, diffraction-limited array camera. Also discussed are the cryogenic star-tracking telescope for Gravity Probe-B, a balloon-borne spectrometer for measurement of lower stratospheric trace constituents, the primary mirror support system design for a cryogenic space telescope, and the SQUID readout and ultralow magnetic fields of Gravity Probe-B.

Melugin, Ramsey K.↗

Science data systems

Digital generation of acceleration voltage for mass spectrometer, and development of low power, nondestructive readout, plated-wire memory

Source record↗