Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “raman”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Ultra-high Information-content Chemical Imaging with Broadband Coherent Anti-Stokes Raman and Two-photon Fluorescence Lifetime Microscopy

Raman fingerprint spectroscopy and fluorescence lifetime imaging are emerging tools for studying metabolic profiles of biological specimens. While Raman fingerprint spectroscopy detects intrinsic molecular vibrations that reflect the molecular composition and chemical environment of a sample, fluorescence lifetime imaging measures changes in the excited-state lifetime of fluorophores that are sensitive to their microenvironments. Here, we present a multimodal imaging platform combining broadband coherent anti-Stokes Raman scattering (BCARS) and two-photon fluorescence lifetime imaging (2p-FLIM) microscopy that can acquire biologically relevant Raman fingerprint spectra and fluorescence lifetime signals in vivo and simultaneously. The tremendous chemical information obtained from spatially co-registered BCARS and 2p-FLIM images allows us to characterize the subtle differences between sub-cellular compartments and verify the potential false-positive results generated by fluorescence imaging alone. This is demonstrated by directly comparing the BCARS, 2p-FLIM, and two-photon excitation fluorescence(TPEF) signals simultaneously obtained from the same dye-stained organelle in the live, intact C. elegans expressing a green fluorescent protein (GFP) marker. In this work, we introduce the BCARS/2p-FLIM/TPEF setup scheme, the image acquisition steps, data processing, and representative results showing that the cross-modality imaging method enables rigorous characterization and in vivo detection at sub-cellular resolution. Furthermore, this protocol provides a framework for simultaneous chemical and fluorescence lifetime imaging to improve the accuracy of biological interpretation in complex living systems.

Xu, Haoyu [Georgia Institute of Technology, Atlant↗

Accurate in vivo tumor detection using plasmonic-enhanced shifted-excitation Raman difference spectroscopy (SERDS)

For the majority of cancer patients, surgery is the primary method of treatment. In these cases, accurately removing the entire tumor without harming surrounding tissue is critical; however, due to the lack of intraoperative imaging techniques, surgeons rely on visual and physical inspection to identify tumors. Surface-enhanced Raman scattering (SERS) is emerging as a non-invasive optical alternative for intraoperative tumor identification, with high accuracy and stability. However, Raman detection requires dark rooms to work, which is not consistent with surgical settings. Methods: Herein, we used SERS nanoprobes combined with shifted-excitation Raman difference spectroscopy (SERDS) detection, to accurately detect tumors in xenograft murine model. Results: We demonstrate for the first time the use of SERDS for in vivo tumor detection in a murine model under ambient light conditions. We compare traditional Raman detection with SERDS, showing that our method can improve sensitivity and accuracy for this task. Conclusion: Our results show that this method can be used to improve the accuracy and robustness of in vivo Raman/SERS biomedical application, aiding the process of clinical translation of these technologies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The application of laser-Raman light scattering to the determination of sulfate in sea and estuarine waters

Laser-Raman light scattering is a technique for determining sulfate concentrations in sea and estuarine waters with apparently none of the interferences inherent in the gravimetric and titrametric methods. The Raman measurement involved the ratioing of the peak heights of an unknown sulfate concentration and a nitrate internal standard. This ratio was used to calculate the unknown sulfate concentration from a standard curve. The standard curve was derived from the Raman data on prepared nitrate-sulfate solutions. At the 99.7% confidence level, the accuracy of the Raman technique was 7 to 8.6 percent over the concentration range of the standard curve. The sulfate analyses of water samples collected at the mouth of the James River, Hampton, Virginia, demonstrated that in most cases sulfate had a constant concentration relative to salinity in this area.

Bandy, A. R.↗

Measurement of Raman spectra of H2O and SO4(-) in seawater

A study of applying laser Raman spectroscopy to remote sensing of the sulfate ion in sea water is in progress. The SO4 Raman spectrum has been obtained from true sea water samples in the laboratory using a CW laser Raman spectrometric system. Radiometric calculations indicate the feasibility of obtaining usable SO4 Raman signals in a field experiment. One of serious difficulties expected in the field experiment would be from fluorescence of phytoplankton and organics.

Houghton, W. M.↗

Remote sensing of subsurface water temperature by laser Raman spectroscopy

This paper describes experimental remote sensing of subsurface water temperature using the Raman spectroscopic technique. By the use of a pulsed laser and range gating detection techniques, Raman scattering is analyzed as a function of depth in a radar-like echo mode, and thus subsurface profiles of temperature and transmission are obtained. Experiments are described in which Raman data using polarization spectroscopy has been obtained from a ship as a function of depth in ocean water near Grand Bahama Island. A spectral temperature accuracy of + or - 1 C has been obtained from this data in the first two optical attenuation lengths. Raman data obtained from ocean water using the NASA airborne oceanographic lidar is also presented.

Leonard, D. A.↗

Remote Raman measurement techniques

The use of laser Raman measurement techniques in remote sensing applications is surveyed. A feasibility index is defined as a means to characterize the practicality of a given remote Raman measurement application. Specific applications of Raman scattering to the measurement of atmospheric water vapor profiles, methane plumes from liquid natural gas spills, and subsurface ocean temperature profiles are described. This paper will survey the use of laser Raman measurement techniques in remote sensing applications using as examples specific systems that the Computer Genetics Corporation (CGC) group has developed and engineered.

Leonard, D. A.↗

Absorption and resonance Raman spectra of Pb2, Pb3, and Pb4 in xenon matrices

Matrix isolation techniques are used to investigate the spectra of lead molecules and, in particular, to obtain resonance Raman spectra of lead vapors isolated in solid xenon matrices. The presence of Pb2 is confirmed by the visible adsorption, and Raman spectra yield a vibrational frequency for the ground state of 108 per cm and a dissociation energy of 8200 per cm. A second resonance Raman progression indicates a Pb3 species of D3h symmetry. Finally, two additional Raman features at approximately 111 per cm spacing are evidence for a third species, tentatively identified as Pb4.

Stranz, D. D.↗

Water Raman normalization of airborne laser fluorosensor measurements - A computer model study

The technique for normalizing airborne lidar measurements of chlorophyll fluoresence by the water Raman scattering signal is investigated for laser-excitation wavelengths of 480 and 532 nm using a semianalytic Monte Carlo methodology (SALMON). The signal-integration depth for chlorophyll fluorescence Z(90,F), is found to be insensitive to excitation wavelength and ranges from a maximum of 4.5 m in clearest waters to less than 1 m at a chlorophyll concentration of 20 microgram/liter. For excitation at 532 nm, the signal-integration depth for Raman scattering, Z(90,R), is comparable to Z(90,F). For excitation at 480 nm, Z(90,R) is four times as large as Z(90,F) in clearest waters but nearly equivalent at chlorophyll concentrations greater than 2-3 microgram/liter. Absolute signal levels are stronger with excitation at 480 nm than with excitation at 532 nm, but this advantage must be weighed against potential ambiguities resulting from different integration depths for the fluorescence and Raman scattering signals in clearer waters. To the precision of the simulations, Raman normalization produces effectively linear response to chlorophyll concentration for both excitation wavelengths.

Poole, L. R.↗

Lower atmospheric temperature profile measurements using a Raman lidar

A Raman lidar system was used to measure the temperature profile of the upper troposphere and lower stratosphere. The system consists of a tripled Nd-YAG laser and a 1.5 meter diameter telescope. Two photomultipliers are used at the output of the telescope to allow for measurements at both the laser wavelength and at the Raman shifted wavelength due to atmospheric nitrogen. The signal from the photomultipliers is recorded as photon counts in 1 microsec bins. The results of a number of laser shots are summed together to provide atmospheric returns which have acceptable signal to noise characteristics. Measurements of the Raman nitrogen return were acquired up to an altitude in excess of 20 km. Temperature profiles were retrieved from the attenuation corrected Raman nitrogen return assuming the atmosphere to be in hydrostatic equilibrium and using the ideal gas law. Retrieved temperature profiles are shown compared with independent temperature measurements.

Melfi, S. H.↗

A combined Raman lidar for low tropospheric studies

One of the main goals of laser sensing of the atmosphere was the development of techniques and facilities for remote determination of atmospheric meteorological and optical parameters. Of lidar techniques known at present the Raman-lidar technique occupies a specific place. On the one hand Raman lidar returns due to scattering on different molecular species are very simple for interpretation and for extracting the information on the atmospheric parameters sought, but, on the other hand, the performance of these techniques in a lidar facility is overburdened with some serious technical difficulties due to extremely low cross sections of Raman effect. Some results of investigations into this problem is presented which enables the construction of a combined Raman lidar capable of acquiring simultaneously the profiles of atmospheric temperature, humidity, and some optical characteristics in the ground atmospheric layer up to 1 km height. The operation of this system is briefly discussed.

Arshinov, Y. F.↗

Theoretical studies of Resonance Enhanced Stimulated Raman Scattering (RESRS) of frequency-doubled Alexandrite laser wavelength in cesium vapor

The solutions for the imaginary susceptibility of the Raman field transition with arbitrary relaxation rates and field strengths are examined for three different sets of relaxation rates. These rates correspond to: (1) Far Infrared (FIR) Raman lasers in the diabatic collision regime without consideration of coupled population decay in a closed system, (2) Raman FIR lasers in the diabatic collision regime with coupled population conserving decay, and (3) IR Raman gain in cesium vapor. The model is further expanded to include Doppler broadening and used to predict the peak gain as a function of detuning for a frequency doubled Alexandrite laser-pumped cesium vapor gain cell.

Lawandy, Nabil M.↗

Raman observations on individual interplanetary dust particles

A Raman study of 20 representative interplanetary dust particles (IDPs) belonging to different infrared spectral classes is discussed. Six different groups of Raman spectra were discerned among the IDPs studied. Groups 1-5 exhibit the Raman signature of poorly crystallized carbonaceous material, with the degree of disorder of this material increasing from group 1 (most ordered) to group 5 (least ordered). Group 1 contains IDPs that have infrared spectra characteristic of olivines, and are deuterium depleted, while those in groups 2, 3, and 4 contain less ordered carbonaceous material and are deuterium enriched, suggesting different carbonaceous carrier phases for deuterium depletions and enrichments. Groups 5 and 6 contain little or no carbonaceous material, with an abundance of deuterium. No obvious relationship was found between Raman groups and infrared classes based on the 10 micron absorption band due to silicates. Because silicates are known to be present, but are not seen, it is presumed that silicate grains are coated with and/or imbedded in carbonaceous material. Several IDPs show broad visible laser-induced photoluminescence, probably produced by a carbonaceous component.

Wopenka, Brigitte↗

Optimization of a Raman shifted dye laser system for DIAL applications

An efficient Raman shifted dye laser system that generates tunable radiation at 765 and 940 nm with a bandwidth of 0.03/cm is described. Operating a Raman cell at hydrogen pressure below 14 atm, optimum first Stokes energy conversions of 45 percent and of 37 percent at 765 and 940 nm, respectively, were recorded. Optical depth measurements made at the centers of twenty-five absorption lines in the P branch of the oxygen A band imply a high spectral purity for both the laser and the Raman shifted radiation, and thus indicate the feasibility of using the stimulated Raman scattered radiation for differential absorption lidar (DIAL) measurements.

Singh, Upendra N.↗

UV Raman spectroscopy of H2-air flames excited with a narrowband KrF laser

Raman spectra of H2 and H2O in flames excited by a narrowband KrF excimer laser are reported. Observations are made over a porous-plug, flat-flame burner reacting H2 in air, fuel-rich with nitrogen dilution to control the temperature, and with an H2 diffusion flame. Measurements made from UV Raman spectra show good agreement with measurements made by other means, both for gas temperature and relative major species concentrations. Laser-induced fluorescence interferences arising from OH and O2 are observed in emission near the Raman spectra. These interferences do not preclude Raman measurements, however.

Shirley, John A.↗

Raman scattering measurements in flames using a tunable KrF excimer laser

A narrow-band tunable KrF excimer laser is used as a spontaneous vibrational Raman scattering source to demonstrate that single-pulse concentration and temperature measurements, with only minimal fluorescence interference, are possible for all major species (O2, N2, H2O, and H2) at all stoichiometries (fuel-lean to fuel rich) of H2-air flames. Photon-statistics-limited precisions in these instantaneous and spatially resolved single-pulse measurements are typically 5 percent, which are based on the relative standard deviations of single-pulse probability distributions. In addition to the single-pulse N2 Stokes/anti-Stokes ratio temperature measurement technique, a time-averaged temperature measurement technique is presented that matches the N2 Stokes Raman spectrum to theoretical spectra by using a single intermediate state frequency to account for near-resonance enhancement. Raman flame spectra in CH4-air flames are presented that have good signal-to-noise characteristics and show promise for single-pulse UV Raman measurements in hydrocarbon flames.

Wehrmeyer, Joseph A.↗

Development and applications of tunable, narrow band lasers and stimulated Raman scattering devices for atmospheric lidar

The main thrust of the program was the study of stimulated Raman processes for application to atmospheric lidar measurements. This has involved the development of tunable lasers, the detailed study of stimulated Raman scattering, and the use of the Raman-shifted light for new measurements of molecular line strengths and line widths. The principal spectral region explored in this work was the visible and near-IR wavelengths between 500 nm and 1.5 microns. Recent alexandrite ring laser experiments are reported. The experiments involved diode injection-locking, Raman shifting, and frequency-doubling. The experiments succeeded in producing tunable light at 577 and 937 nm with line widths in the range 80-160 MHz.

Wilkerson, Thomas D.↗

Thermal processing of omicron-terphenyl - A Raman study

Raman spectra from omicron-terphenyl sealed in glass capillary tubes were acquired over temperatures ranging from 233 to 343 K. Over this temperature range, omicron-terphenyl can exist in the solid-crystalline, molten, supercooled-liquid, and amorphous-glassy states. Representative structure-sensitive spectra are presented along with a qualitative description. The lattice spectral feature occurring at a Raman shift of 123/cm displays abrupt changes in profile and intensity as melting and glass transition occur. The intensity ratio of the C-C stretching 996/cm line and C-H stretching line at 1008/cm displays a change related to the transformation of the ordered-crystalline phase to the disordered-liquid or glassy state. At a Raman shift of 1162/cm the solid-crystalline state shows a splitting due to the effect of the crystal field. The possibility of using these structure-sensitive Raman characteristics for in situ diagnostics during materials processing is discussed.

Biswas, A.↗

The Use of Spontaneous Raman Scattering for Hydrogen Leak Detection

A fiber optic probe has been built and demonstrated that utilizes back scattered spontaneous Raman spectroscopy to detect and identify gaseous species. The small probe, coupled to the laser and data acquisition equipment with optical fibers, has applications in gaseous leak detection and process monitoring. The probe design and data acquisition system are described. Raman scattering theory has been reviewed and the results of intensity calculations of hydrogen and nitrogen Raman scattering are given. Because the device is in its developmental stage, only preliminary experimental results are presented here. Intensity scans across the rotational-vibrational Raman lines of nitrogen and hydrogen are presented. Nitrogen at a partial pressure of 0.077 MPa was detected. Hydrogen at a partial pressure of 2 kPa approached the lower limit of detectability with the present apparatus. Potential instrument improvements that would allow more sensitive and rapid hydrogen detection are identified.

Degroot, Wim A.↗