Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

(U) Segmented Scintillator Pitch, Thickness, and Septa Material Effects on the Swank Factor, Quantum Efficiency, and DQE(0) for High-Energy X-Ray Radiography

Scintillator design is an important aspect in constructing a radiographic facility in order to collect the most robust data possible. For the proposed Enhanced Capabilities for Sub-critical Experiment (ECSE) facility in Nevada, we explored a permutation of 13 segmented scintillator designs in order to understand the best performance and trade offs for each design. We calculated the quantum efficiency, Swank factor, and detective quantum efficiency at zero-frequency (DQE(0)) for each scintillator design in order to compare performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-situ Radiography of Hydrogen Porosity Growth and Development in Aluminum Welds

In aluminum welding, hydrogen contamination is the main cause of the welding defect, porosity. Porosity in welds can adversely affect the mechanical properties such as tensile strength, fatigue life and ductility. There have been a variety of solutions to help reduce porosity in aluminum welds including finding the source of hydrogen. However, in some cases the amount of hydrogen may be drastically reduced but impossible to completely eliminate. Another approach to this issue is to understand where a pore originates and how it moves and grows within the weld pool. This information may lead to a more innovative method for pore elimination during gas tungsten arc (GTA) welding of aluminum.

42 ENGINEERING↗

Fast Neutron Radiography Simulations

Conclusions: Elements other than detector array can heavily impact performance; Must consider a variety of alterations to an imaging array to determine an optimal system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Fidelity Dynamic Neutron Imaging and Radiography for Subcritical Experiments and Other Applications (Final Report)

This project aims to advance neutron technologies that support subcritical experiments (SCEs) and other dynamic material applications. In previous years, there were three main thrusts for this project. The first and main effort focused on imaging the source of neutrons on a dense plasma focus (DPF). The second portion focused on improving the neutron yield from a DPF. The source developed on the Nevada National Security Site (NNSS) Gemini DPF yielded ~8 × 10 11 deuterium-deuterium (DD) neutrons/pulse in relatively short pulse widths of approximately 100 ns FWHM.

47 OTHER INSTRUMENTATION↗

An Electron-Beam Ion-Neutralization Diagnostic for the Scorpius Radiography Accelerator

Electron beam spilling onto the beam pipe can produce positive ions that are accelerated inward into the beam body by its space charge. These ions partially neutralize the space charge, thereby causing the beam to be mismatched to the magnetic fields used for transport. A diagnostic of neutralization effects has been used on present accelerators, and in this note the feasibility of its use on a future accelerator is assessed.

43 PARTICLE ACCELERATORS↗

Diagnostics for Short-Pulse Radiography

The Multi-Probe project is developing radiographic techniques using probe beams generated by short-pulse lasers. Shortcomings in present detectors and future capabilities in new devices are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiplexing and Demultiplexing Signals for Radiography Application Using the Discrete Fourier Transform

Our goal is to develop an X-ray phase-contrast imaging system that can provide excellent soft tissue contrast of phase, attenuation, and small-angle scatter. We propose to replace the common system of G0, G1, and G2 gradings with a biprism array to replace the G1 grading and introduce a novel X-ray tube designed to replace the motion of the phase stepping grading G2. The proposed X-ray tube uses temporal multiplexing to provide simultaneous virtual “electronic phase stepping.” In this work the discrete Fourier transform is used to separate from the composite measurement individual X-ray phase contrast measurements sampled at different frequencies. The method performs a discrete Fourier transform of a composite refence sequence to obtain using the frequency amplitudes calibration factors needed to extract the X-ray phase contrast measurement amplitudes from the composite image. The composite reference sequence is the sum of the individual sequences, at different frequencies, with amplitudes of one. The method takes the discrete Fourier transform of this composite reference sequence; whereby, the amplitude of each frequency component is compared with the total sum of its stand-alone sequence amplitude. A calibration factor is determined so that the amplitude of this composite reference frequency times the calibration factor must equal the total sum of the sequence amplitude—the zero-frequency amplitude of the discrete Fourier transform of its stand-alone sequence. To demultiplex the composite measured signal these calibration factors are multiplied by the amplitudes of the frequency components of the discrete Fourier transform of the composite X-phase-contrast measurement to obtain the amplitude of each frequency encoded measurement. Using these calibration factors, we demonstrate with the discrete Fourier transform in Mathematica the extraction of individual images from a composite image that one would expect obtaining from our proposed new X-ray phase contrast imaging system. We then demonstrate as an example how using images from X-ray phase contrast data one can calculate phase, attenuation and the dark field images using grading phase step data supplied to use from Microworks, GmbH in Karlsruhe, Germany.

42 ENGINEERING↗