Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quadrupole magnet”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Mitigating Transition in the Fermilab Booster Using a Triple Phase Jump

The PIP-II project will significantly enhance neutrino production for DUNE, Fermilab s flagship long-baseline neutrino oscillation experiment, by doubling the beam power delivered by the accelerator complex. To achieve this, the total charge injected from the new PIP-II linac into the Booster rapid cycling synchrotron (RCS) will increase from $4.5\times 10^{12}$ to $6.5\times 10^{12}$ protons per pulse. Simultaneously, the Booster s ramp rate will rise from 15 to 20 Hz, while the injection energy will go from 400 MeV to 800 MeV. The Booster accelerates the beam to 8 GeV and crosses transition at $\gamma_t=5.45$. In current operations, no dedicated $\gamma_t$ jump system is employed; instead, longitudinal emittance growth is controlled via an active quadrupole-mode feedback system. Downstream, the Recycler Ring uses slip-stacking to accumulate beam and increase bunch intensity. However, this process imposes a constraint on the longitudinal emittance at Booster extraction, limiting it to 0.1 eV-s (95\%) to avoid excessive particle loss. Because collective effects scale with intensity, additional measures to mitigate transition crossing may be required to stay below this limit. One potential approach is the so-called triple phase-jump technique. While the method has known limitations, it offers some advantages: it can be implemented using the existing digital low-level RF (LLRF) system, requires no additional magnets or pulsed power supplies, and remains compatible with quadrupole-mode feedback.

Ostiguy, Jean-Francois [Fermilab] (ORCID:000000029↗

Anisotropic magnetotransport properties of the heavy-fermion superconductor CeRh 2 As 2

Here, we report anisotropic resistivity measurements of the heavy-fermion superconductor CeRh 2 As 2 in magnetic fields up to 16 T and temperatures down to 0.35 K. The measured CeRh 2 As 2 resistivity shows a signature corresponding to the suggested quadrupole-density-wave order state at T 0 ~0.5 K for both measured directions. For a magnetic field applied along the tetragonal a axis, T 0 is enhanced with magnetic field reaching ~1.75 K at 16 T. Further, a magnetic field-induced transition occurs at μ 0 H m ~ 8.1 T corresponding to a change to a new broken symmetry state. For a magnetic field applied along the c axis, T 0 is suppressed below our base temperature ~0.35 K by μ 0 H ~ 4.5 T, a field close to the previously reported field-induced transition within the superconducting state suggested to be from an even-parity to an odd-parity state. Our results indicate that the multiple superconducting phases in CeRh 2 As 2 are intimately tied to the suppression of the proposed quadrupole-density-wave phase at T 0 .

36 MATERIALS SCIENCE↗

Four-dimensional phase-space reconstruction of flat and magnetized beams using neural networks and differentiable simulations

Beams with cross-plane coupling or extreme asymmetries between the two transverse phase spaces are often encountered in particle accelerators. Flat beams with large transverse-emittance ratios are critical for future linear colliders. Similarly, magnetized beams with significant cross-plane coupling are expected to enhance the performance of electron cooling in hadron beams. Preparing these beams requires precise control and characterization of the four-dimensional transverse phase space. In this study, we employ generative phase-space reconstruction techniques to rapidly characterize magnetized and flat-beam phase-space distributions using a conventional quadrupole-scan method. The reconstruction technique is experimentally demonstrated on an electron beam produced at the Argonne Wakefield Accelerator and successfully benchmarked against conventional diagnostics techniques. Specifically, we show that predicted beam parameters from the reconstructed phase-space distributions (e.g., as magnetization and flat-beam emittances) are in excellent agreement with those measured from the conventional diagnostic methods. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Exploration of ICP platforms for measuring elemental impurities in uranium ore concentrates

Presented here is a look at different inductively coupled plasma (ICP) platforms including sector field, triple quadrupole mass spectrometric configurations, and optical emission spectroscopy. The goal of this paper was to convey the feasibility of trace elemental analysis of a uranium ore concentrate with varying ICP-based platforms. It was predicted that low mass elements would be better determined through optical means, or the mass collision/reaction technology of the triple quadrupole mass spectrometer, in comparison to high resolution measurements of magnetic sector-based configurations. Ultimately, it is difficult to achieve an “optimal” analysis of 20+ elements, for numerous samples, on a single platform, especially when time, measurement reproducibility, sensitivity, and robustness should be considered. The work presented here highlights the advantages and disadvantages of the respective trace elemental analysis platforms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CP2 skyrmions and skyrmion crystals in realistic quantum magnets

Abstract Magnetic skyrmions are nanoscale topological textures that have been recently observed in different families of quantum magnets. These objects are called CP 1 skyrmions because they are built from dipoles—the target manifold is the 1D complex projective space, CP 1 ≅ S 2 . Here we report the emergence of magnetic CP 2 skyrmions in a realistic spin-1 model, which includes both dipole and quadrupole moments. Unlike CP 1 skyrmions, CP 2 skyrmions can also arise as metastable textures of quantum paramagnets, opening a new road to discover emergent topological solitons in non-magnetic materials. The quantum phase diagram of the spin-1 model also includes magnetic field-induced CP 2 skyrmion crystals that can be detected with regular momentum- (diffraction) and real-space (Lorentz transmission electron microscopy) experimental techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compact, Achromatic Non-scaling FFAG Accelerator for HEP, Commercial and Medical Applications (CRADA FRA-2008-0005 Final Report)

Proton and light-ion accelerators have many research and medical applications, but the current state of technology in accelerators severely limits their widespread use: (1) synchrotrons have an intrinsic low duty cycle and become quite large for light ions; and (2) cyclotrons do not have energy variability and require complex superconducting magnets for high energy. A new concept in non-scaling Fixed-Field Alternating-Gradient (FFAGs) has been invented that incorporates both the energy variability of the synchrotron and the high duty cycle of the cyclotron. The concept uses normal-conducting, combined-function magnets that apply only constant (dipole) and linear-gradient (quadrupole) fields to stabilize the accelerator. This project will develop an optimized design for a new non-scaling and cost-effective innovation in FFAG accelerators. The accelerator design will have optics that can stably accelerate protons to 250 MeV (or higher) and carbon ions to =200 MeV, an energy considered ideal for radiation therapy. Phase I will optimize, fully simulate, and demonstrate the feasibility of this accelerator. Commercial Applications and other Benefits as described by the awardee: The fixed-field acceleration concept should eliminate some of the most pronounced technical difficulties, expense, maintenance, and required expertise faced in conventional proton and light-ion accelerators. In addition to the application for high energy physics, these accelerators should have application in cancer treatment, radiopharmaceuticals, and medical isotope production, and materials science.

43 PARTICLE ACCELERATORS↗

Fermilab’s horizontal test stand upgrade overview and commissioning

Cryo-assemblies with the low-beta Nb3Sn quadrupoles for the High Luminosity LHC (HL-LHC) upgrade will be tested at Fermilab’s magnet test facility. Total of 10 cryo-assemblies will be delivered to CERN within the US HL-LHC Accelerator Upgrade Project (AUP). The horizontal test stand at Fermilab already has been used for testing the existing LHC inner-triplet quadrupoles, but the stand and corresponding electrical and cryogenic sub-systems were not operational more than a decade. In order to restore the test stand functions and meet the design and test requirements for the high luminosity LHC magnets, the existing horizontal test facility at Fermilab underwent a significant refurbishment of the cryogenic and mechanical components. Most of the upgrades were completed and verified during so called zero-magnet test by late 2020, and then final commissioning of the upgraded test stand was completed during the first cryo-assembly test in 2023. These tests verified all the cryo-mechanical installations, as well as the test stand operations, including controlled cooldown and operation at 1.9 K, the helium recovery capabilities, magnet protection and process controls.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analytical expression of a finite, long, conical canted-cosine-theta coil for particle collider interaction regions

Magnets in the accelerator interaction region (IR) present significant challenges because of high field requirements and limited available space. Conical-shaped magnets offer advantages in these environments by allowing closer placement to the interaction point while maintaining clearance from synchrotron radiation. Interestingly, numerical studies have shown that conical canted-cosine-theta (CCT) designs produce a constant field distribution along the axial direction in the IR quadrupoles for the Electron-Ion Collider (EIC) at Brookhaven National Laboratory. However, the field harmonics generated by conical CCT windings are not yet fully understood. This paper presents an analytical approach to describe the magnetic field produced by a conical surface current and proposes a method for designing conical CCT magnets for accelerator applications. First, we begin with a surface current sheet having a general cosine-theta distribution in spherical coordinates and solve the vector potential using the Green’s function. The magnetic fields generated by the conical current sheet are expressed using associated Legendre polynomials. These results are then related to circular field harmonics and integral field harmonics for designing a coil that produces a pure multipole field. Next, a single layer of the conical CCT winding path is produced based on the cosine-theta current distribution. Finally, the magnetic field quality of dipole and quadrupole conical CCT coils with multiple layers is verified using the Biot-Savart law.

Yang, Ye↗

Fermilab's Horizontal Test Stand Upgrade Overview and Commissioning

Cryo-assemblies with the Nb 3 Sn MQXFA low-beta quadrupoles for the High Luminosity LHC (HL-LHC) upgrade will be tested at Fermilab's magnet test facility. A total of 10 cryo-assemblies will be delivered to CERN within the US HL-LHC Accelerator Upgrade Project (AUP). The horizontal test stand at Fermilab already has been used for testing the existing LHC inner-triplet quadrupoles, but the stand and corresponding electrical and cryogenic sub-systems were not operational for more than a decade. In order to restore the test stand functions and meet the design and test requirements for the HL-LHC magnets, the existing horizontal test facility at Fermilab underwent a significant refurbishment of the cryogenic and mechanical components. Most of the upgrades were completed and verified during so called zero-magnet test by late 2020, and then final commissioning of the upgraded horizontal test stand was completed during the first cryo-assembly test in 2023. These tests verified the major cryo-mechanical installations, as well as the basic test stand operations, including controlled cooldown and operation at 1.9 K, magnet protection and process controls. Here, in this paper, overview of the Fermilab's horizontal test facility upgrade and commissioning of these upgrades are presented.

43 PARTICLE ACCELERATORS↗

Ramsey envelope modulation in NV diamond magnetometry

Nitrogen-vacancy (NV) spin ensembles in diamond provide an advanced magnetic sensing platform, with applications in both the physical and life sciences. The development of isotopically engineered 15 NV diamond offers advantages over naturally occurring 14 NV for magnetometry, due to its simpler hyperfine structure. However, for sensing modalities requiring a bias magnetic field not aligned with the sensing NV axis, the absence of a quadrupole moment in the 15 N nuclear spin leads to pronounced envelope modulation effects in time-dependent measurements of 15 NV spin evolution. While such behavior in spin echo experiments are well studied, analogous effects in Ramsey measurements and the implications for magnetometry remain underexplored. Here, we derive the modulated 15 NV Ramsey response to a misaligned bias field, using a simple vector description of the effective magnetic field on the nuclear spin. The predicted modulation properties are then compared to experimental results, revealing significant magnetic sensitivity loss if unaddressed. We demonstrate that double-quantum coherences of the NV S=1 electronic spin states dramatically suppress these envelope modulations, while additionally proving resilient to other parasitic effects such as strain heterogeneity and temperature shifts.

36 MATERIALS SCIENCE↗

Uncertainty quantification of transition operators in the empirical shell model

While empirical shell model calculations have successfully described low-lying nuclear data for decades, only recently has significant effort been made to quantify the uncertainty in such calculations. Here, in this study, we quantify the statistical error in effective parameters for transition operators in empirical calculations in the sd (1s 1/2 -0d 3/2 -0d 5/2 ) valence space, specifically the quenching of Gamow-Teller transitions, effective charges for electric quadrupole (E2) transitions, and the effective orbital and spin couplings for magnetic dipole (M1) transitions and moments. We find the quenching factor for Gamow-Teller transitions relative to free-space values is tightly constrained. For effective M1 couplings, we found isoscalar components more constrained than isovector. This detailed quantification of uncertainties, while highly empirical, nonetheless is an important step towards interpretation of experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fundamental U235 Nuclear Resonance Spectroscopy (FY2022 LDRD End of Year Report)

Enriched uranium (U-235) is ubiquitous in the nuclear industry yet many of its fundamental properties have never been studied using magnetic resonance. To remedy this we built a high frequency nuclear quadrupole resonance spectrometer that is capable of measuring the very high quadruple resonance signals of U-235.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ICP-MS For Analysis of Lithium Isotopic Ratios in Materials Highly Enriched in 7Li - CRADA 626 (Abstract)

The purpose of this project is to develop analytical methods that can be deployed for analysis of lithium isotope enrichment products. One method involves rapid, high-throughput, relatively low precision analysis for direct monitoring of enrichment processes. A second method involves slower, but more precise analysis of final products of the enrichment process. We will use commercially available analytical equipment (quadrupole base inductively coupled plasma mass spectrometry and multi-collector magnetic sector inductively coupled plasma mass spectrometry) so that the analytical methods developed can be applied broadly.

07 ISOTOPE AND RADIATION SOURCES↗

Printed Circuit Board Based Rotating Coils for Measuring Sextupole Magnets

Here, the use of Printed Circuit Boards (PCBs) for the inductive pick-up windings of rotating coil probes has made the construction of these precision magnetic measurement devices much more accessible. This paper discusses the design details for PCBs which on each layer of the board provide for simultaneous analog bucking (suppression) of dipole, quadrupole, and sextupole field components so as to more accurately measure the higher order harmonic fields in sextupole magnets. Techniques to generate designs are discussed, as well as trade-offs to optimize sensitivity. Examples of recent sextupole PCBs and their performance are given.

43 PARTICLE ACCELERATORS↗

Advanced Design for the WIQ Magnet With Steering Corrector Function

The Facility for Rare Isotopes Beams (FRIB) delivers heavy-ion primary beams at energies of up to 300 MeV/u at 10 kW of beam power to generate rare isotope beams for experiments and will eventually operate at beam power of 400 kW. The preseprator of the Advanced Rare Isotope Separator (ARIS) is equipped with six warm-iron quadrupole (WIQ) singlets and two dipoles integrated right after the production target. They have a compact structure and operate in a high radiation vacuum environment within a hot cell having remote handling capabilities for installation and maintenance. Due to asymmetry with respect to the quadrupole poles, nested sextupole excitations in WIQs induce vertical dipoles that offset the centroid trajectory; Magnet misalignments also result in trajectory offsets. Such offsets degrade separator performance but can be minimized by changing the current distribution on sextupole and octupole coils. In this work, we show how modifications to the WIQ coil design can allow superimposed dipole fields to be included to the octupole and sextupole windings, as well as addition of dipole components by splitting coil currents over groups with separator power supplies. Adjusting the group currents can cancel the sextupole-induced vertical dipole component which can be as high as 0.012 Tm. Octupole coil changes may superimpose a horizontal dipole integrated strength as high as 0.0332 Tm. Unwanted higher harmonics induced as a side effect of the new design are kept to a minimum such that separator performance is preserved as much as possible.

Accelerator magnets↗

Status of the MQXFB Nb 3 Sn Quadrupoles for the HL-LHC

Here, the cold powering test of the first two prototypes of the MQXFB quadrupoles (MQXFBP1, now disassembled, and MQXFBP2), the Nb 3 Sn inner triplet magnets to be installed in the HL-LHC, has validated many features of the design, such as field quality and quench protection, but has found performance limitations. In fact, both magnets showed a similar phenomenology, characterized by reproducible quenches in the straight part inner layer pole turn, with absence of training and limiting the performance at 93% (MQXFBP1) and 98% (MQXFBP2) of the nominal current at 1.9 K, required for HL-LHC operation at 7 TeV. Microstructural inspections of the quenching section of the limiting coil in MQXFBP1 have identified fractured Nb 3 Sn sub-elements in strands located at one specific position of the inner layer pole turn, allowing to determine the precise origin of the performance limitation. In this paper we outline the strategy that has been defined to address the possible sources of performance limitation, namely coil manufacturing, magnet assembly and integration in the cold mass.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fabrication of the Fermilab Pre-Series Cold Mass for the HL-LHC Accelerator Upgrade Project

Fermilab is fabricating ten full length cold masses for the high-luminosity Large Hadron Collider Accelerator Upgrade Project (HL-LHC AUP). One practice assembly and one pre-series assembly have been completed. Here this paper summarizes the construction details. Topics include incoming inspection, bus assembly, component machining, shell forming, beam tube insertion, bus expansion loop installation, instrumentation installation, electrical testing, heat exchanger installation and final assembly welding. In-process surveys, alignment measurements and testing are presented and explained. Problems encountered during construction and their solutions are discussed.

43 PARTICLE ACCELERATORS↗

Eddy current studies for the beam screen of the Electron-Ion Collider hadron storage ring superconducting magnets

A copper-clad stainless steel beam screen will be installed in each of the Relativistic Heavy Ion Collider (RHIC) superconducting (SC) magnets used for making the Electron-Ion Collider (EIC) Hadron Storage Ring (HSR). Eddy currents are induced within conductors to oppose a changing magnetic flux. Eddy currents will appear on the EIC HSR beam screens during ramp up and ramp down, after a magnet quenches and when reversing the polarity of the γ transition jump quadrupoles during γ transition crossing. This study evaluates the magnitude of the eddy currents, the temperature increase due to Joule heating and the stress at the beam screens from the eddy-current induced force.

43 PARTICLE ACCELERATORS↗