Rate equations for nitrogen molecules in ultrashort and intense x-ray pulses
Abstract Not Provided
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract Not Provided
We investigate the two-photon double ionization of atomic magnesium induced by ultrashort pulses. Though the initial and final state symmetries are comparable to the same process in helium, in stark contrast the range of photon energies for which nonsequential ionization is the only open pathway is narrow (less than 1 eV) in magnesium. Thus several sequential ionization pathways feature heavily in these processes. Nonetheless, it is found that for pulse durations between 0.25 and 2.0 fentoseconds, the joint angular dependence of the ejected electrons can depend sensitively on pulse length, varying between the strictly back-to-back ejection characteristic of nonsequential ionization to other distributions. The significance of excited-state correlating configurations in representing the initial state of magnesium is discussed in the light of their consequences for the resulting angular distributions at photon energies where sequential ionization can access intermediate states that lie nearby in energy, particularly for longer pulses.
Not Available
We demonstrate nonlinear compression of mid-infrared pulses from a Cr:ZnSe chirped-pulse amplifier using a gas-filled stretched hollow-core fiber followed by bulk-material compression. Starting from 90 fs, 2.45 µm pulses with 5.3 mJ energy, spectral broadening in the gas-filled capillary combined with optimized dispersion management enables compression to 15 fs, less than two optical cycles at 2.45 µm, with 3.3 mJ pulse energy, corresponding to a peak power of approximately 0.12 TW. The simplicity of the approach, based on a single hollow-core fiber stage and bulk dispersion compensation, makes it scalable to higher energies and establishes a robust route to mid-infrared drivers for high harmonic generation and attosecond applications.
Pulse stretching circuit can linearly stretch pulses as narrow as 50 nanoseconds and block incoming pulses following accepted input pulse until processing has been completed. It also removes baseline distortion by being completely direct coupled and provides monitor output which measures true number of input events that exceed predetermined threshold.
Fabricated and tested CTP IPPTs at cone angles of 20deg, 38deg, and 60deg, and performed direct single-pulse impulse bit measurements with continuous gas flow. Single pulse performance highest for 38deg angle with impulse bit of approx.1 mN-s for both argon and xenon. Estimated efficiencies low, but not unexpectedly so based on historical data trends and the direction of the force vector in the CTP. Capacitor charging system assembled to provide rapid recharging of capacitor bank, permitting repetition-rate operation. IPPT operated at repetition-rate of 5 Hz, at maximum average power of 2.5 kW, representing to our knowledge the highest average power for a repetitively-pulsed thruster. Average thrust in repetition-rate mode (at 5 kV, 75 sccm argon) was greater than simply multiplying the single-pulse impulse bit and the repetition rate.
A unique application of the pulsed-wire measurement method has been implemented for alignment of 2.5 T pulsed solenoid magnets. The magnetic axis measurement has been shown to have a resolution of better than 25 {micro}m. The accuracy of the technique allows for the identification of inherent field errors due to, for example, the winding layer transitions and the current leads. The alignment system is developed for the induction accelerator NDCX-II under construction at LBNL, an upgraded Neutralized Drift Compression experiment for research on warm dense matter and heavy ion fusion. Precise alignment is essential for NDCX-II, since the ion beam has a large energy spread associated with the rapid pulse compression such that misalignments lead to corkscrew deformation of the beam and reduced intensity at focus. The ability to align the magnetic axis of the pulsed solenoids to within 100 pm of the induction cell axis has been demonstrated.
A device for creating an optic pulse with different wavelengths separated by time. A pump laser is configured to output energy to a dye cell which, responsive to the energy, outputs an optic pulse. Mirrors direct the optic pulse away from the dye cell towards a spectrograph. The spectrograph has an input and two or more outputs. The spectrograph receives and converts the optic pulse to a wavelength separated optic signal presented on the two or more outputs. A first optic cable has an input end and an output end. The input end receives a first output from the spectrograph. A second optic cable has an input end and an output end. The input end receives a second output from the spectrograph. The second optic cable is a different length than the first optic cable to establish a time shift between the signals exiting the first and second cable.
Relevant to laser based electron/ion accelerations, a single shot second harmonic generation frequency resolved optical gating (FROG) system has been developed to characterize laser pulses (80 J, {approx}600 fs) incident on and transmitted through nanofoil targets, employing relay imaging, spatial filter, and partially coated glass substrates to reduce spatial nonuniformity and B-integral. The device can be completely aligned without using a pulsed laser source. Variations of incident pulse shape were measured from durations of 613 fs (nearly symmetric shape) to 571 fs (asymmetric shape with pre- or postpulse). The FROG measurements are consistent with independent spectral and autocorrelation measurements.
The development of ultra-compact particle accelerators and accelerator-based high-power THz generators are some of the top priorities for research and development programs around the world. These tools require the development of accelerating structures, operating in the mm-Wave and THz range, where diagnostics are not available or are insufficient. This article presents the design of a pulse-to-pulse THz spectrometer, primarily developed for diagnostics of accelerating structures and THz radiation sources. In particular, this spectrometer can be used to detect RF pulse shortening caused by vacuum breakdown and beam misalignment in THz accelerators, as well as for bunch length monitoring and radiation source diagnostics. The spectrometer is based on a diffraction grating and is capable of covering a frequency range where RF-based breakdown measurements are not possible. We have built and tested the first prototype with different sources in a frequency range of 0.1-1.0 THz. In this article, we present the physical design, supported numerical simulations, electronics development, and test results.
Long pulse, high frequency quasi-direct-current (dc) oxygen plasma immersion ion implantation (PIII) is utilized to create a superhydrophobic polytetrafluoroethylene (PTFE) surface with a water contact angle of over 150 deg. This technique allows the use of a high duty cycle without deleterious effects such as extensive sample heating encountered in conventional PIII. Scanning electron microscopy images review submicrometer-nanometer structures on the PTFE surface after long pulse, high frequency PIII indicative of ion implantation. On the other hand, plasma modification is the dominant effect in short pulse, low frequency PIII. Quasi-dc PIII is demonstrated to offer adjustable synergistic plasma and ion beam effects.
The analytical Gaussian electron pulse propagation model of Michalik and Sipe [J. Appl. Phys. 99, 054908 (2006)] is extended to include the action of external forces on the pulse. The resultant ability to simulate efficiently the effect of electron optical elements (e.g., magnetic lenses and radio-frequency cavities) allows for the rapid assessment of electron pulse delivery systems in time-resolved ultrafast electron diffraction and microscopy experiments.
We report on experimental study on chemical etch selectivity of fused silica irradiated by femtosecond laser with either linear or circular polarization in a wide range of pulse energies. The relationships between the etch rates and pulse energies are obtained for different polarization states, which can be divided into three different regions. A drop of the etch rate for high pulse energy region is observed and the underlying mechanism is discussed. The advantage of using circularly polarized laser is justified owing to its unique capability of providing a 3D isotropic etch rate.
A pulsed emissive probe technique is presented for measuring the plasma potential of pulsed plasma discharges. The technique provides time-resolved data and features minimal disturbance of the plasma achieved by alternating probe heating with the generation of plasma. Time resolution of about 20 ns is demonstrated for high power impulse magnetron sputtering (HIPIMS) plasma of niobium in argon. Spatial resolution of about 1 mm is achieved by using a miniature tungsten filament mounted on a precision translational stage. Repeated measurements for the same discharge conditions show that the standard deviation of the measurements is about 1-2 V, corresponding to 4%-8% of the maximum plasma potential relative to ground. The principle is demonstrated for measurements at a distance of 30 mm from the target, for different radial positions, at an argon pressure of 0.3 Pa, a cathode voltage of -420 V, and a discharge current of about 60 A in the steady-state phase of the HIPIMS pulse.
We measure the ion beam current and the plasma parameters by using the pulse mode microwave operation in the first stage of a tandem type ECRIS. The time averaged extracted ion beam current in the pulse mode operation is larger than that of the cw mode operation with the same averaged microwave power. The electron density n{sub e} in the pulse mode is higher and the electron temperature T{sub e} is lower than those of the cw mode operation. These plasma parameters are considered to cause in the increase of the ion beam current and are suitable to produce molecular or cluster ions.
Barrier discharges at atmospheric pressure in nitrogen-oxygen mixture powered by high voltage pulses of widths between 10 {mu}s and 200 ns were investigated. The development of the microdischarges on rising and falling slopes was recorded by streak and intensified CCD cameras simultaneously. The breakdown on the falling slope strongly depends on the pulse width. As a result of pulse width variation the starting point of ignition changes and positive and negative streamers occur simultaneously in the falling slope. The observed effect is caused by the electric field rearrangement in the gap due to the different positive ion densities related to their gap crossing times.
A laser ion source that produces shortly bunched ion beam is proposed. In this ion source, ions are extracted immediately after the generation of laser plasma by an ultra-short pulse laser before its diffusion. The ions can be injected into radio frequency (RF) accelerating bucket of a subsequent accelerator. As a proof-of-principle experiment of the ion source, a RF resonator is prepared and H{sub 2} gas was ionized by a short pulse laser in the RF electric field in the resonator. As a result, bunched ions with 1.2 mA peak current and 5 ns pulse length were observed at the exit of RF resonator by a probe.