Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system interconnection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

The Potential Impact of Offshore Wind Energy on a Future Power System in the U.S. Northeast

This study aims to understand and quantify the potential impact of offshore wind on a future electricity system in the U.S. Northeast. In this analysis, a detailed representation of the Northeast power system is adopted, using a generation portfolio for 2024 paired with offshore wind nameplate capacities of 0 gigawatts (GW), 2 GW, and 7 GW. The analysis identifies points of offshore wind interconnection in the ISO-New England and New York Independent System Operator control areas and uses hourly wind profiles from the Wind Integration National Dataset Toolkit. Hourly simulations of the 2024 power system operations show an ability to accommodate the prescribed offshore wind capacities by adapting the system's generation dispatch. Curtailment levels of offshore wind range between 4% and 5%. Offshore wind generation displaces primarily natural-gas combined-cycle generation; however, requires increased flexibility from combined cycles through more frequent start-ups. The number of hours with transmission congestion increases because of offshore wind injection, with varying impact on a subregional level. Offshore wind's capacity credit was found to be 14.5%-28.3% and is lower than estimated in other large-scale power system studies, in part because this study considered a different weather year and a power system representation with higher shares of solar PV and onshore wind. The reliability contribution of resources is a topic area identified for more research and collaboration. The 7-GW scenario shows a reduction in locational marginal price of 11%, with production cost savings of up to 18% compared to the 0-GW scenario.

17 WIND ENERGY↗

Grid Application and Controls Development for Medium-Voltage SiC-Based Grid Interconnects

This paper studies, the grid-interconnection requirements of directly connected medium-voltage (MV) Silicon Carbide-based (SiC-based) converters and details the necessary control implementations. These power electronic converters follow the interconnection standard IEEE 1547-2018, but can also have additional controls supported by the microgrid standards in IEEE 2030.7, which is demonstrated in this work. Additionally, this paper defines the grid applications realized by these directly connected medium-voltage power electronic converters at the distribution scale and demonstrates results. The controls for the studied grid applications are then developed and implemented on the controller. The paper also includes details of the control algorithm development and validations of the control algorithm through hardware-in-the-loop results.

28 EE - Advanced Manufacturing Office (EE-5A)↗

Sensitivity-based voltage constraints for optimal power flow in low-voltage distribution feeders

The optimal power flow (OPF) problem for distribution systems can include network details down to the low-voltage (LV) points of interconnection of individual customers. This paper addresses the implementation of voltage magnitude constraints, and sets forth a practicable approach for capturing the effects on voltage from the switching behavior of loads (e.g., heat pumps, air conditioners, water heaters, or pool pumps) and from the variability of renewable generation (e.g., rooftop solar). The proposed method adjusts the OPF voltage constraints based on forecasts of load and generation upper and lower bounds, in conjunction with sensitivity factors derived from the power flow equations. An illustrative OPF formulation is also provided, which incorporates transformer models that include core loss. We demonstrate that accurate modeling of these LV network components is critical to avoid voltage violations at customer points of interconnection. Furthermore, the ideas are validated through numerical case studies on a realistic distribution feeder.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Estimation, Minimization, and Validation of Commutation Loop Inductance for a 135-kW SiC EV Traction Inverter

With growing interests in low inductance SiC based power module packaging, it is vital to focus on system level design aspects to facilitate easy integration of the modules and reap system level benefits. To effectively utilize the low inductance modules, busbar and interconnects should also be designed with low stray inductances. A wholistic investigation of the flux path and flux cancellations in the module-busbar assembly which as differentially coupled series inductors is thus mandatory for a system level design. This work presents a busbar design which can be adopted to effectively integrate the CREE’s low inductance 1.2 kV/1.7 kV SiC power modules. The paper also proposes a novel measurement technique to measure the inductance of the modulebusbar assembly as a whole rather than deducing it from individual components. The inductance of the overall commutation loop of the inverter which encompasses the SiC power module, interconnects and PCB busbar have been estimated using finite element analysis (FEA). Furthermore, insights gained from FEA provided the guidelines to decide on the placement of the decoupling capacitors in the busbar to minimize the overall commutation loop inductance from 12.8 nH to 7.4 nH which resulted in significant reduction in the device voltage overshoot. The simulation results have been validated through measurements using an impedance analyzer with less than 5% difference between extracted loop inductance from FEA and measurements. The bus bar design study and the measurement technique discussed in this paper, can be easily extended to other power module packages. Finally, the 135 kW inverter has been compared to a similar highpower inverter utilizing a laminated busbar to highlight the performance of the former.

42 ENGINEERING↗

Impact of Hydrological Data on Power System Operational Studies: Preprint

Hydropower is expected to play an important role in maintaining grid reliability and flexibility as the share of of variable renewable energy increases. While the current hydropower operational models have been studied and used widely, they haven't been updated for decades to meet new performance standards. For example, current steady state and dynamic models often neglect hydrological conditions, which may lead to unrealistic expectations when relying on hydropower for energy and ancillary services. To study this impact, a multi-timescale hydrological model was created by leveraging the National Renewable Energy Laboratory-developed Multi-timescale Integrated Dynamics and Scheduling (MIDAS) tool. Using MIDAS, we compare the impact of considering hydrological conditions in a day-ahead unit commitment (DAUC) schedule on the reduced 240-bus Western Interconnect (WI) test system under winter and summer case studies. We show that neglecting current hydrological conditions of hydropower plants in power system models can lead to an overestimation of hydropower capabilities, which could lead to power balancing issues. For example, power system DAUC simulation results of our reduced test system show that in the case where hydrological conditions are not considered in the model, an approximate 31% overestimation of hydropower capabilities occurs in the summer case and approximately 60% occurs in the winter case compared to what is available. Additionally, results show an underestimation of WI day-ahead power system generation costs by approximately $54M - $80M in the weekly summer scenario and $116M - $126M in the weekly winter scenario. This analysis helps to underscore the importance of considering hydrological data in power system operational studies.

ENERGY PLANNING, POLICY, AND ECONOMY,HYDRO ENERGY↗

Multi-modality deep learning for pulse prediction in homogeneous nonlinear systems via parametric conversion

In this Letter, we introduce FusionNet, a multi-modality deep learning framework designed to predict and analyze output pulses in high-power rare-earth-doped laser systems driving parametric conversion in homogeneous guided nonlinear media. FusionNet integrates temporal, spectral, and physical experimental conditions to model ultrafast nonlinear phenomena, including parametric nonlinear frequency conversion, self-phase modulation, and cross-phase modulation in homogeneous guided systems such as gas-filled hollow-core fibers. These systems bridge physical models with experimental data, advancing our understanding of light-guiding principles and nonlinear interactions while expediting the design and optimization of on-demand high-power, high-brightness systems. Our results demonstrate a 73% reduction in prediction error and an 83% improvement in computational efficiency compared to conventional neural networks. This work establishes a new paradigm for accelerating parametric simulations and optimizing experimental designs in high-power laser systems, with further implications for high-precision spectroscopy, quantum information science, and distributed entangled interconnects.

47 OTHER INSTRUMENTATION↗

Explaining System-Level Prognostics with Established Machine Learning Methods

System-level prognostics is crucial for ensuring reliability and enabling predictive maintenance in complex systems with interconnected components. This study presents a framework that integrates data-driven methods to predict the remaining useful life (RUL) of a subsystem under multiple and concurrent faults within a nuclear power plant system with explainable artificial intelligence (XAI). A nuclear power plant (NPP) operation was simulated to model the degradation behavior of NPP components, and four machine learning models—Gradient Boosting Regressor (GBR), Support Vector Regressor (SVR), Fully Connected Neural Network (FCNN), and Long Short-Term Memory (LSTM)—were evaluated for prognostics with a novel system RUL parameter. The LSTM model demonstrated potential superior repeatability, while SHAP (SHapley Additive exPlanations) for explainability provided consistent and trustworthy global explanations. In contrast, LIME (Local Interpretable Model-agnostic Explanations) offered localized interpretability but showed reduced stability for sequential data. Key findings include the interplay between component-level degradation and system-wide performance, with LSTM effectively capturing these dynamics through sequence-level predictions. The XAI techniques enhanced transparency by identifying critical features influencing model predictions and aligning with domain knowledge. Furthermore, this framework has significant implications for improving trust and understanding in predictive maintenance, particularly in safety-critical industries like nuclear energy.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cyber and Physical Security Analysis of GSI and Noventum Application for IoT Communications

We present our findings of the red team exercise conducted on the device and application developed by Guardian Sensors, Inc. (GSI) and Noventum. The app is used for situational awareness and control of photovoltaics (PV) and microgrid energy systems. The assessments performed are practical case scenarios that assess the risks and vulnerabilities posed by the app through targeted activities that could be engaged by an adversary. The assessment team’s results and recommendations are provided to inform on and mitigate the identified weaknesses to improve secure user authentication, connections, and communications. The recommendations in this report are not intended to be a security panacea but will add the desired defense-in-depth layer to securing communication of such interconnected systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preliminary Design Process for Networked Microgrids

Changes in economic, technology, and environmental policies are resulting in a re-evaluation of the dependence on large central generation facilities and their associated transmission networks. Emerging concepts of smart communities/cities are examining the potential to leverage cleaner sources of generation, and the potential to integrate electricity generation with other municipal functions. When grid-connected, these generation assets can supplement the existing interconnections with the bulk transmission system, and in the event of an extreme event, they can provide power via networks of microgrids. While the design process for a single stand-alone microgrid is relatively well understood, the process of designing the infrastructure for networked microgrid operations has not been well studied. Because of the wide range of potential operational goals for microgrids, it is typical to follow the engineering process of developing an initial conceptual design, a preliminary design, a detailed design, and then a final as-built design. The conceptual design is typically completed without detailed engineering analysis, and the preliminary design is the first stage that requires it. This paper presents a process for developing the preliminary design for networked microgrids, which can then be used as a basis for the final as-built design.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity Enhancement for Multi-Infeed High-Voltage DC Systems

Composed of multiple two-terminal high-voltage DC (HVDC) transmission systems, a multi-infeed HVDC (MIDC) system exchanges massive power among multiple asynchronous AC systems. However, as an intrinsically cyber-physical system, an MIDC system could suffer from cyber-attacks, leading to massive power mismatches in multiple AC systems, and resulting in catastrophic consequences. Since the sequential responses of an MIDC system and interconnected AC systems are in different timescales, this paper first establishes a two-timescale model to evaluate the sequential impacts caused by cyber-attacks. Then, an event-triggered cyber-defense strategy is proposed to enhance the cybersecurity of an MIDC system by mitigating multiple non-simultaneous cyber-attacks. Whenever new cyber-attack events occur, the proposed cyber-defense strategy, which is mathematically modeled as a mixed-integer quadratic programming problem, is executed on-line and updated in an event-triggered manner. Here, simulation results on an MIDC system demonstrate that the low-cost and almost blind cyber-attacks can cause severe frequency deviations, and the proposed strategy can mitigate multi-cyber-attacks effectively.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity at the Grid Edge: Protecting LA's Energy Systems in a Connected World

Join SoCalGas and the National Laboratory of the Rockies (NLR) for an insightful webinar on securing operational technology and energy systems. Los Angeles has the second-largest metro by population in the nation, making it vital to protect the energy infrastructure that powers day-to-day life. However, cybersecurity for energy systems is an immense challenge due to an increasing number of interconnected devices and stakeholders. While there was traditionally a limited need to secure energy infrastructure, the grid is only becoming smarter and more software-defined. Amid aging infrastructure and evolving cyber threats, the need to ensure the security of energy is at an all-time high. Together, SoCalGas and NLR are assessing the current state-of-the-art of the energy ecosystem to understand gaps in current best practices and technologies relevant to powering the city of Los Angeles.

97 MATHEMATICS AND COMPUTING↗

Modeling Power Plant Siting Opportunities and Constraints in the Eastern Interconnection

The electrical transmission grid is a critical part of the U.S. national infrastructure, and its modernization is a U.S. Department of Energy (DOE) priority. We describe the Energy Zones Mapping Tool (EZMT), a unique, powerful, and public web-based system with multi-criteria decision analysis (MCDA) models for more than 20 power plant technologies and many other capabilities. Through a case study on natural gas combined cycle (NGCC) power plants in the Eastern Interconnection (EI), we provide an example of incorporating an EZMT MCDA model into a larger planning context, with projections of interconnection-level capacity expansion, thermoelectric power plant retirements, and water availability. Our results provide insights on candidate NGCC site distributions and the criteria influencing them. The case study provides both an efficient methodology for performing similar analyses and hundreds of candidate NGCC power plant sites that can be studied in more detail as potential project sites.

20 FOSSIL-FUELED POWER PLANTS↗

Leading Energy Analysis: Data-Driven Insights That Power Our Energy Future

Energy analysts at the National Renewable Energy Laboratory (NREL) use a broad set of expertise and cutting-edge tools to capture the complexities of our interconnected energy system. Decision-makers rely on these insights to drive cost savings, enhance grid reliability, support long-term innovation, and bolster America's energy workforce and global competitiveness. This fact sheet highlights some of NREL's high-impact analyses, data, and tools, largely focusing on power grid analysis.

data↗

Secondary Networks and Protection: Implications for DER and Microgrid Interconnection

Secondary networks are used to supply power to loads that require very high reliability and are in use around the world, particularly in dense urban downtown areas. The protection of secondary network systems poses unique challenges. The addition of distributed energy resources (DERs) to secondary networks can compound these challenges, and deployment of microgrids on secondary networks will create a new set of challenges and opportunities. This report discusses secondary networks and their protection, the challenges associated with interconnecting DERs to a secondary network, issues expected to be associated with creating microgrids on secondary networks, standards that deal with these challenges and issues, and suggestions for research and development foci that would yield new means for addressing these challenges.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A High-Fidelity Electromagnetic Transient Model of Inverter-based Resources Integrated to an IEEE-9 Bus System for Benchmarking Studies

An inverter-based resource (IBR) is a source of electricity that is asynchronously connected to the electrical grid via an electronic power converter. These power sources lack the intrinsic behaviors of the standard power plants, presenting specific challenges to system stability. These power sources lack the intrinsic behaviors of the standards power plants and their features are almost entirely defined by the control strategy used on them, presenting specific challenges to system stability as their penetration increases into the already fragile Bulk Power System (BPS). Utilizing renewable energy has a great upside but the electrical industry needs to understand the requirements like performing electromagnetic transient (EMT) simulation studies in planning and/or in interconnection studies. This paper presents the development of a high-fidelity EMT model based on commercial equipment and field parameters, which at the same time aims to study the increasing penetration of IBRs and their impact on the actual BPS. The open-source EMT model developed will be a benchmarking example that can be used to evaluate algorithms in the power grid (including evaluating grid-forming controls, power system monitoring and operation, etc.).

Martinez Montejano, Misael↗

Management of Risk and Uncertainty Through Optimized Co-Operation of Transmission Systems and Microgrids With Responsive Loads (Final Report)

The evolution of the power system to the reliable, efficient and sustainable system of the future will involve development of both demand- and supply-side technology and operations. Ambitious national and state-level goals around the decarbonization of electricity relies on the integration of very high levels of renewable resources, most of which are variable and intermittent. The use of demand response is an ideal approach to counterbalance the intermittency of renewable generation and brings the consumer into the spotlight. Though individual consumers are interconnected at the low-voltage distribution system, these resources are typically modeled as variables at the transmission network level. Demand-side participation cannot be leveraged effectively without explicitly including the distribution system dynamics in the optimization-based wholesale market operations. This project grew from a vision for co-optimized interaction of distribution systems, or microgrids, with the high-voltage transmission system. In this framework, microgrids encompass consumers, distributed renewables and storage. The energy management system of the lower voltage system (distribution or microgrid) can also sell (buy) excess (necessary) energy from the transmission system. Until recently, very little research had been conducted on the co-optimization of these two systems due to computational limitations. However, advances in computational capabilities, and the judicious use of decomposition methods and innovative approximation methods for high-dimension dynamic programming made this goal a viable objective for this project, leading to a fundamental shift in the ability to integrate and fully utilize demand-side resources. To this end, the modeling framework developed introduces a novel co-optimization framework, to include the operations of both the transmission and distribution systems (or microgrids) in operational decision making. This framework was used to analyze renewable and distributed generation along with responsive demand and to compare the capability of co-optimized systems to perform with higher levels of variable renewables. An ideal microgrid is defined as an electric entity capable of operating in both interconnected (with the high-voltage grid) and islanded mode. As such, the microgrid should incorporate generating units (traditional units and intermittent) and if needed, exchange power with the high-voltage grid. The interplay between the microgrid and high-voltage grid motivated the development of the co-optimization approach to ensure efficient performance of the interconnected network. Results show that the use of a bi-level optimization approach is an appropriate structure, capable of co-optimizing a transmission system with multiple distribution systems and microgrids. While increasing the number of connected systems provides increasing flexibility for renewables integration this can also the economic benefits to the low-voltage subsystems with each additional system connected. Comparison of a traditional single-level decision structure with the co-optimization approach illustrates a reduction in overall system cost under co-optimization, while specific cost allocations to transmission and distribution systems are changed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DOE Laboratory Support for DER and Inverter-Based Resource Integration Standards (ACCEL II) (Final Report)

This report documents efforts under a project that followed work completed under Accelerating Systems Integration Standards (ACCEL). In this continuation, the project team provided support for updates to critical standards for interconnection and interoperability of distributed energy resources at the distribution level. In addition, the project contributed to development of guidance for operational best practices of the bulk power system with high levels of DERs. Additional goals of the project were to inform and develop improved recommended practices and certification standards for end-to-end interoperability of DERs, utilizing Sandia laboratory assets when needed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of an Innovative Inspection Tool for Superheater Tubes in Fossil Fuel Power Plants

Fossil fuel power plants are complex systems containing multiple components that require periodic health monitoring. Failures in these systems can lead to increased downtime for the plant, reduction of power, and significant cost for repairs. Inspections of the plant’s superheater tubes are typically manual, laborious, and extremely time-consuming. This is due to their small diameter size (between 1.3 and 7.6 cm) and the coiled structure of the tubing. In addition, the tubes are often stacked close to each other, limiting access for external inspection. This paper presents the development and testing of an electrically powered pipe crawler that can navigate inside 5 cm diameter tubes and provide an assessment of their health. The crawler utilizes peristaltic motion within the tubes via interconnected modules for gripping and extending. The modular nature of the system allows it to traverse through straight sections and multiple 90° and 180° bends. Additional modules in the system include an ultrasonic sensor for tube thickness measurements, as well as environmental sensors, a light detecting and ranging (LiDAR) sensor, and camera. Furthermore, these modules utilize a gear system that allows for 360° rotation and provides a means to inspect the entire internal circumference of the tubes.

36 MATERIALS SCIENCE↗