Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Secured fault detection in a power substation

Systems and methods for fault detection and protection in electric power systems that evaluates electromagnetic transients caused by faults. A fault can be detected using sampled data from a first monitored point in the power system. Detection of fault transients and associated characteristics, including transient direction, can also be extracted through evaluation of sample data from other monitored points in the power system. A monitoring device can evaluate whether to trip a switching device in response to the detection of the fault and based on confirmation of an indication of detection of fault transients at the other monitored points of the power system. The determination of whether to trip or activate the switching device can also be based on other factors, including the timing of receipt of an indication of the detection of the fault transients and/or an evaluation of the characteristics of the detected transients.

Cui, Tao↗

Data-Informed Evaluation Framework for Integrated Energy Systems: Insights from Power, Process Heat, and Hydrogen Production Applications

The multi-criteria decision analysis (MCDA) framework provides a systematic evaluation of the diverse preferences and performance metrics associated with alternative solutions. This approach is advantageous over a single-criterion methodology, which are only valid under conditions that assume ceteris paribus or an "apples-to-apples" comparison. However, selecting suitable technologies for integrated energy systems (IES) can be likened to an "apples-to-oranges" comparison, given the heterogeneous factors at stake. These factors include economics and performance parameters, geological compatibility, and environmental impacts. Consequently, past research has often employed a mixture of qualitative and quantitative criteria tailored to the specific interests of each study. While the method proves effective in handling the intricate interplay of criteria, the resulting rankings and scores can vary from study to study. This inconsistency is introduced from the use of subjectively defined thresholds and weights. As a result, decision-makers frequently find it challenging to establish clear connections between specific criteria and the resulting scores, as the transformation of criteria into ordinal scores results in a substantial loss of information. To address this challenge, we introduce a data-informed IES evaluation framework that offers comprehensive, interpretable, and traceable evaluations backed by quantifiable rationale. First, we identified key IES evaluation criteria from a decade of literature, focusing on relevant IES applications in power, process heat, and hydrogen production. We leveraged state-of-the-art cost estimates from the Idaho National Laboratory (INL) and technical data from 78 reactor designs from the International Atomic Energy Agency (IAEA) and the Organization for Economic Co-operation and Development - Nuclear Energy Agency (OECD-NEA). Lastly, we established thresholds by analyzing the mean, variance, root mean square, and slope of values across alternatives, categorizing the preferences of decision-makers into distinct utility functions, such as linear, saturating, exponential, and stepwise. Our approach yielded two main outcomes: (1) it provided consistent assessments across different stakeholder groups and (2) it visualized uncertainties in the decision-making context via comprehensive sensitivity analysis. To demonstrate the impact of our framework, we conducted case studies on 6 reactor designs (AP1000, NuScale, BWRX-300, Xe-100, eVinci, iMSR) for the three applications. Our data-driven framework proved to be highly effective in addressing heterogenous uncertainties faced by varied decision-makers? preferences and IES applications, as well as cost and technical estimates of advanced reactors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Data-Informed Evaluation Framework for Integrated Energy Systems: Insights from Power, Process Heat, and Hydrogen Production Applications

The multi-criteria decision analysis (MCDA) framework provides a systematic evaluation of the diverse preferences and performance metrics associated with alternative solutions. This approach is advantageous over a single-criterion methodology, which are only valid under conditions that assume ceteris paribus or an "apples-to-apples" comparison. However, selecting suitable technologies for integrated energy systems (IES) can be likened to an "apples-to-oranges" comparison, given the heterogeneous factors at stake. These factors include economics and performance parameters, geological compatibility, and environmental impacts. Consequently, past research has often employed a mixture of qualitative and quantitative criteria tailored to the specific interests of each study. While the method proves effective in handling the intricate interplay of criteria, the resulting rankings and scores can vary from study to study. This inconsistency is introduced from the use of subjectively defined thresholds and weights. As a result, decision-makers frequently find it challenging to establish clear connections between specific criteria and the resulting scores, as the transformation of criteria into ordinal scores results in a substantial loss of information. To address this challenge, we introduce a data-informed IES evaluation framework that offers comprehensive, interpretable, and traceable evaluations backed by quantifiable rationale. First, we identified key IES evaluation criteria from a decade of literature, focusing on relevant IES applications in power, process heat, and hydrogen production. We leveraged state-of-the-art cost estimates from the Idaho National Laboratory (INL) and technical data from 78 reactor designs from the International Atomic Energy Agency (IAEA) and the Organization for Economic Co-operation and Development - Nuclear Energy Agency (OECD-NEA). Lastly, we established thresholds by analyzing the mean, variance, root mean square, and slope of values across alternatives, categorizing the preferences of decision-makers into distinct utility functions, such as linear, saturating, exponential, and stepwise. Our approach yielded two main outcomes: (1) it provided consistent assessments across different stakeholder groups and (2) it visualized uncertainties in the decision-making context via comprehensive sensitivity analysis. To demonstrate the impact of our framework, we conducted case studies on 6 reactor designs (AP1000, NuScale, BWRX-300, Xe-100, eVinci, iMSR) for the three applications. Our data-driven framework proved to be highly effective in addressing heterogenous uncertainties faced by varied decision-makers? preferences and IES applications, as well as cost and technical estimates of advanced reactors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Hardware Platform for Studying Naval Power Electronic Power Distribution Systems

Abstract – Future intelligent ship system designs will likely include electric propulsion, numerous highpower sensors, and directed energy weapons. Supply and control of these large nonlinear loads will require a networked, multi-converter power electronic power distribution system. This work presents a hardware platform to emulate a microgrid power system with multiple power converters and a power data communication network. The platform is reconfigurable and can include both AC and DC power distribution zones, representative of shipboard power systems. It also allows for the study of both power control actuation and power data communication delays. Since the platform is based on electric power hardware, spatial and temporal uncertainties are inherently embedded in the system. Specifically, this work examines the control actuation of multiple pulsed power loads in a single microgrid. Several pulse load levels and operating scenarios have been implemented and measured. A framework for control parameter quantification is presented, and various metrics are explored to capture pulse signal characteristics. The sensitivity of pulse load metric parameters is analyzed. Dynamic shipboard, mission-specific load profiles coupled with pulse loads can also be emulated in the hardware platform.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hybrid power system control and operating strategy based on power system state vector calculation

Controlling a hybrid power system includes calculating a power system state vector based on energy demand and a stored data array including a matrix defined by a power system hardware configuration. The control further includes producing a power request based on the power system state vector, and varying a flow of energy amongst energy devices using drive linkages in the hybrid power system based on the power request. Related apparatus, control logic and controller structure is disclosed.

Guo, Fang↗

Big Data Analytic for Cascading Failure Analysis

With the challenges of increased grid dynamics and more variability of power generation from renewable energy sources, rapidly increasing complexity in the grid model, and abundant data from measurements and simulations, the requirements for computational analysis have also increased dramatically. Power system operators and engineers need to analyze more scenarios, extract meaningful information from a larger set of data, and respond more quickly when faced with these new challenges for large-scale applications, such as contingency analysis. This paper proposes a novel big data analysis approach for power system cascading analysis, prevention, and remediation. The developed techniques will be capable of cascading analysis, better assessment of the system’s vulnerability level, as well as proposing potential remediation. Case studies using IEEE 118-bus system and a 500-bus system, with a comparison against a commercial tool, validate the advantages of the developed big data approach: accurate prediction, and more importantly, faster and effective correction actions.The developed techniques could be further used for other power system applications.

big data, cascading analysis, corrective action, m↗

From Data to Knowledge: A Graph-Based Reliability Approach to Assess System Health

With the goal of maximizing plant reliability and availability, complex systems such as nuclear power plants continuously monitor and record the performance and the health status of many components, assets, and systems. Such data may take the form of online monitoring data, condition reports, and maintenance reports and it carries the potential to provide system engineers with insights into anomalous behaviors or degradation trends as well as the possible causes behind them and to predict their direct consequences. The analysis of such data poses however few challenges. While some of these challenges are technical in nature (i.e., data are often distributed over several physical servers or databases), others are conceptual in nature (i.e., data elements come in different formats, numeric or textual), and measured values have different scales (e.g., vibration spectra and oil temperature). This paper directly tackles these challenges, and it focuses on the integration of all these data elements in order to assist plant system engineers in analyzing component, assets, and systems performances and optimize maintenance activities. This is performed by 1) extracting knowledge from textual data via technical language processing methods, and 2) quantifying system, asset, and component health from numeric condition-based data. We rely on model-based system engineering (MBSE) models of systems and assets to identify their architecture and functional (i.e., cause and effect) relations. Numeric and textual data elements are then associated with an MBSE graph element, based on their nature. This bonding of MBSE models and data elements constitutes a first-of-its-kind knowledge graph of a nuclear power plants system, with data elements being organized in a structured manner that enables system engineers to identify cause-effect trends in data elements and carry out appropriate actions in response.

97 MATHEMATICS AND COMPUTING↗

sdt (Solar Data Tools) [SWR-25-130]

Solar Data Tools (sdt) is an open-source Python library for analyzing PV power (and irradiance) time-series data. It was developed to enable analysis of unlabeled PV data, i.e. with no model, no meteorological data, and no performance index required, by taking a statistical signal processing approach in the algorithms used in the package’s main data processing pipeline. Solar Data Tools empowers PV system fleet owners or operators to analyze system performance a hundred times faster even when they only have access to the most basic data stream—power output of the system.

Meyers-Im, Bennet [National Laboratory of the Rock↗

Python Measurement-Informed Modelling Method (PythonMIMM) v1.02

This Python program implements the calculations for electrical energy efficiency and electrical losses in the paper "Energy and power quality measurement for electrical distribution in AC and DC microgrid buildings" (https://www.sciencedirect.com/science/article/abs/pii/S0306261921015658). The inputs are metered voltage, current, or power data of meters located throughout the DC system. In the absence of metered data, the user must input some other information about the building such as the types of power converters or wire lengths. The program will build a loss model of the DC system based on metered data and electrical information. It will also generate an equivalent AC system and determine the losses and efficiency.

Gerber, Daniel [Lawrence Berkeley National Laborat↗

Power-oriented bus encoding for data transmission

Systems, apparatuses, and methods for reducing the toggle rates on buses are disclosed. A computing system includes a source which provides packets for transmission on a bus. The packet is compressed by a compression engine. The compressed data format of the packet includes locations (bit positions) referred to as holes which do not include valid data. A bus configuration module identifies the locations of the holes and replaces the holes with information from a previous packet transmitted earlier on the bus. The bus configuration module also determines a new transmission bus width for the packet for lowering the bus toggle rate on the bus during transmission.

42 ENGINEERING↗

Impacts of swinging door lossy compression of synchrophasor data

As the number of operational Phasor Measurement Units (PMUs) is increasing, compression is becoming crucial for efficiently transferring and storing enormous amount of synchrophasor data continuously measured from a power system. Some utilities in the U.S. have already adopted a nonlinear compression technique, called Swinging Door Algorithm (SDA), assuming compressed data meets technical and regulatory requirements without resulting in any degradation of the measurements. This paper studies impacts of this compression algorithm on field measured and simulated PMU data, and presents results from spectral analyses of raw and decompressed measurements. The results show blind application of the SDA compression alters frequency content in the measurements and introduces false harmonics and aliasing. These can lead to false conclusions being drawn from the measurements about the power system condition.

42 ENGINEERING↗

SMART SiC Power ICs: Scalable, Manufacturable, and Robust Technology for SiC Power Integrated Circuits (Final Technical Report)

This collaborative project was initiated with the goal of developing Scalable, Manufacturable, and Robust Technology for SiC Power Integrated Circuits (SMART SiC Power ICs). In pursuit of this objective, innovative designs and fabrication processes were implemented, enabling the development of large-scale (>1 cm²) SiC Complementary Metal-Oxide-Semiconductor (CMOS) integrated circuits and high-voltage (400–600 V) lateral power MOSFETs (HV-LDMOS) on 150 mm 4H-SiC substrates. The resulting SMART SiC Power ICs are tailored to support a wide range of applications requiring diverse voltage and power levels, including automotive systems, industrial equipment, electronic data processing, energy harvesting, and power conditioning. To achieve the proposed ‘SMART’ technology for SiC ICs, the team focused on 1) the Development of highly scalable CMOS (with high channel mobilities for n-type and p-type MOSFETs), LDMOS (~600V, 10A rated), and IC technologies, 2) Establishment of a manufacturable process baseline in a production-grade-, 150mm, SiC fabrication facility, and 3) Demonstration of SMART SiC ICs. The project initially comprised of fabricating 5 lots. In lot 1 monolithic integration using a single process was achieved. Here, we were able to successfully accomplish Integrated HV NMOSFET with LV CMOS on N-epi/N+ Substrate. The HV NMOS demonstrated a Breakdown Voltage (BV) more than 600V. Circuit demonstration of CMOS was also another achievement from this lot. In lot 2, priority was in place for isolation and integration. Here we addressed the isolation concerns and integrated the HV NMOS and LV CMOS using the N-epi/P-epi/N+ substrate. Similar to the lot 1, we were able to achieve a BV of 600 V for HV NMOS. Optimized gate oxide process with high channel mobilities, better gate oxide reliability, development of SPICE models, successful ohmic process development, novel wafer area saving design layouts, P+ isolation schemes with channeling implantations and high temperature operational circuits demonstrations are some of the key highlights from lot 1 and lot2. In lot 3, discrete device performances of HV NMOS with a BV ~700V and reliable LV CMOS performances were achieved. Also, novel architectural solutions were successfully implemented to suppress the electric field crowding at the gate oxide for reliable operations. In lot 4, half bridge power driver ICs with a conversion efficiency of (target 90% to 95%) in the 1-5MHz switching frequency range for output power between 25 W to 3 kW have been included in. However, due to the unfortunate events of sudden foundry shutdown (SiCamore Semi) the processing of lot 4 wafers came to a complete stop (January 2024). Arrangements have recently been made to shift the fabrication to another foundry, General Electric Aerospace. The fabrication process now on course (as of December 2024). Characterizations are delayed due to this unfortunate circumstance. The proposed trench architectural-based devices and ICs (lot 5) underwent modifications from the original project proposal. This change was necessitated by limitations in the availability of trench-based processes at commercial production-grade fabrication facilities in the US. Apart from above achievements, a Process Development Kit (PDK) was successfully developed for planar type SiC CMOS/LDMOS.

42 ENGINEERING↗

Evaluating a Commercial Dynamic Line Rating Software with the National PMU Dataset

To accelerate the development of data-driven applications for power systems, the Department of Energy (DOE) supported the collection and curation of a synchrophasor dataset spanning two years of observations from transmission utilities across the US. This National PMU Dataset (NPDS) was anonymized and distributed to awardees of a DOE research grant under nondisclosure agreements (NDAs) but has also been retained at PNNL to enable further research. Agreements with data contributors prevent the data from being shared outside the organization. However, establishing a blind research validation methodology is envisioned to maximize the value proposition of the NPDS. In this validation strategy, researchers may share algorithms/software (potentially as executables to protect intellectual property) with PNNL, and PNNL will share feedback about the software’s performance on subsets of the NPDS. Such a blind methodology ensures that sensitive information about critical infrastructure remains protected, but the value of the NPDS can be extended to research beyond PNNL. Through iterative feedback, the algorithms may be tweaked to address real-world artifacts. As the NPDS data is temporally and geographically diverse, it may capture features absent in smaller datasets used during the development of the algorithm under test. This report presents lessons learned from applying the blind validation methodology to LineID™, a synchrophasor-based dynamic line rating software developed by Topolonet Corporation. Improvements made to the software through iterative feedback, limitations of the validation methodology, as well as how the limitations of the NPDS affected the evaluation process are discussed. Observations indicate that the proposed validation methodology can be valuable for evaluating other tools in the future.

97 MATHEMATICS AND COMPUTING↗

Electrical circuit control in power systems

Electrical circuit control techniques in power systems are disclosed herein. In one embodiment, a supervisory computer in the power system can be configured to fit phasor measurement data from phasor measurement units into a Gaussian distribution with a corresponding Gaussian confidence level. When the Gaussian confidence level of the fitted Gaussian distribution is above a Gaussian confidence threshold, the supervisory computer can be configured to perform an ambient analysis on the received phasor measurement data to determine an operating characteristic of the power system. The supervisory computer can then automatically applying at least one electrical circuit control action to the power system in response to the determined operating characteristic.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A General Method for Estimating Zonal Transmission Interface Limits from Nodal Network Data: Preprint

Capacity expansion models for the electric power system often employ zonal (rather than nodal) resolution, necessitating estimates of aggregate power transfer limits across the interfaces between model zones. Interface limits between planning areas are sometimes published, but they are not generalizable to arbitrary zone shapes. There is thus a need for a reproducible method for estimating interface transfer limits (ITLs) between user-defined zones directly from nodal transmission system data. Here, we present a simple method for estimating ITLs using a DC power flow approximation via the power transfer distribution factor (PTDF) matrix. Linear optimization is performed to identify the distribution of power flows that maximizes the total flow on interface-crossing lines, subject to individual line ratings, limits on bus injection/withdrawal, and the relationships among flows, injections, and withdrawals imposed by the PTDF matrix. We demonstrate the application of the method on a 134-zone ~65000-bus system, and we explore the influence of flow direction, contingency level, and zone size on the estimated ITLs. There is significant heterogeneity in the ratio of the ITL to the sum of interface-crossing line ratings, which highlights the importance of accounting for the physical constraints on power flows imposed by Kirchhoff's laws when estimating zonal ITLs.

17 WIND ENERGY↗

Data Centers and Digital Assurance Workshop 3 – Mitigations for Digital Assurance Risks

The third session of the TADA (Technical Assistance for Digital Assurance) Data Centers Cohort, held on November 18, 2025, focused on developing mitigation strategies for digital assurance risks identified in previous workshops. Hosted by Idaho National Laboratory (INL) and ScottMadden, the session emphasized the application of Cyber-Informed Engineering (CIE) to data center infrastructure, particularly at the utility–data center interface. Participants revisited and ranked key digital assurance risks, including architecture and interface weaknesses, governance gaps, and AI-enabled threats. The workshop introduced the 12 principles of CIE, advocating for consequence-focused design, engineered controls, and secure information architecture to proactively reduce cyber-physical vulnerabilities. These principles were applied to critical data center systems such as power distribution, UPS, cooling, SCADA/BMS, and grid-forming batteries. The session also addressed governance challenges at the interconnection boundary, highlighting the need for clear roles in telemetry sharing, firmware management, and trip settings. Special attention was given to emerging risks from behind-the-meter (BTM) generation, including reverse-power flow and the integration of small modular reactors (SMRs), which shift data centers from large loads to complex generation nodes. Participants explored how interconnection agreements can serve as enforceable instruments for digital assurance, and reviewed gaps in current standards such as NERC CIP, IEC 62443, and IEEE 1547. The workshop concluded with pathways to standardization, including model agreement language, state-level programs, and expanded NERC guidance. INL also presented tools and frameworks for secure procurement and supplier risk management, reinforcing the need for integrated engineering and policy solutions to secure the evolving data center–grid ecosystem. Session 3 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗