At least 199 records · Page 11

DQ Admittance Extraction for Inverter-Based Resources

The power grid industry is pushing for electromagnetic transient (EMT)-based studies for generation interconnection and planning process due to high penetrations of inverter-based resource (IBRs). Vendor-specific and site-specific black-box IBR models are preferred in those simulation studies. For small-signal analysis, measurement-based admittance models are necessary. In this paper, we demonstrate the extraction of frequency-domain dq frame IBR models. These linear models are specific to operating conditions. We demonstrate two extraction methods: frequency scan and a step response-based method. The latter relies on converting time-domain responses to Laplace-domain expressions via eigensystem realization analysis (ERA). Both can lead to dq admittance representation and the latter is time saving.

admittance model↗

Optimising Foil Selection for Neutron Activation Systems

Abstract Neutron spectrum unfolding using activation foils is currently the primary technique planned for measuring the neutron energy spectrum at the first wall of power-generating fusion reactors. Room for improvement in the effectiveness of current foil selection was identified, and a program produced to select foils procedurally in order to maximise the accuracy of the unfolding procedure. Using Kullback–Leibler Divergence to quantify the accuracy, the spectrum unfolded by the procedurally selected set of foils is found to be more accurate than the spectrum unfolded by a set of foils used in the literature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mod-5A wind turbine generator program design report. Volume 3: Final design and system description, book 2

The design, development and analysis of the 7.3MW MOD-5A wind turbine generator is documented. The report is divided into four volumes: Volume 1 summarizes the entire MOD-5A program, Volume 2 discusses the conceptual and preliminary design phases, Volume 3 describes the final design of the MOD-5A, and Volume 4 contains the drawings and specifications developed for the final design. Volume 3, book 2 describes the performance and characteristics of the MOD-5A wind turbine generator in its final configuration. The subsystem for power generation, control, and instrumentation subsystems is described in detail. The manufacturing and construction plans, and the preparation of a potential site on Oahu, Hawaii, are documented. The quality assurance and safety plan, and analyses of failure modes and effects, and reliability, availability and maintainability are presented.

Source record↗

Reliability of emergency and standby diesel generators: Impact on energy resiliency solutions

Emergency diesel generators are the most common form of backup power for critical loads when the grid fails and are most often deployed as stand-alone generators (<2000 kW) tied to individual buildings for hospitals, emergency services, military bases, ports, airports, industries, and commercial facilities. Understanding the finite reliability of emergency diesel generators during continuous operation is critical for energy planners, managers, and end-users. A new analysis of two large non-public emergency diesel generator operational data sets shows that commonly used reliability metrics are inadequate to predict the performance during a grid outage. Additional metrics addressing the likelihood of an emergency diesel generator to be available at the time an outage starts, successfully start and carry load, and constantly run for the duration of the outage are needed to predict the continuous run-time reliability of emergency diesel generators during a grid outage. This is the first analysis of the reliability of modern generators that follow standard maintenance protocols commonly used for backup power and these new metrics are shown to be dependent on the level of emergency diesel generator maintenance with values that can vary by more than an order of magnitude. Even using the new metrics for well-maintained emergency diesel generators, the analysis shows that the single emergency diesel generators configurations are only 80% likely to provide power for the duration of a two-week grid outage.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

Orion Launch Abort Vehicle Attitude Control Motor Testing

Current Orion Launch Abort Vehicle (LAV) configurations use an eight-jet, solid-fueled Attitude Control Motor (ACM) to provide required vehicle control for all proposed abort trajectories. Due to the forward position of the ACM on the LAV, it is necessary to assess the effects of jet-interactions (JI) between the various ACM nozzle plumes and the external flow along the outside surfaces of the vehicle. These JI-induced changes in flight control characteristics must be accounted for in developing ACM operations and LAV flight characteristics. A test program to generate jet interaction aerodynamic increment data for multiple LAV configurations was conducted in the NASA Ames and NASA Langley Unitary Plan Wind Tunnels from August 2007 through December 2009. Using cold air as the simulant gas, powered subscale models were used to generate interaction data at subsonic, transonic, and supersonic test conditions. This paper presents an overview of the complete ACM JI experimental test program for Orion LAV configurations, highlighting ACM system modeling, nozzle scaling assumptions, experimental test techniques, and data reduction methodologies. Lessons learned are discussed, and sample jet interaction data are shown. These data, in conjunction with computational predictions, were used to create the ACM JI increments for all relevant flight databases.

Murphy, Kelly J.↗

Resilience Analytics for Interdependent Power and Water Distribution Systems

The occurrence of large-scale outages in power distribution systems (PDSs) caused, for instance, by extreme weather events has raised concerns on the cascading impact of the power outages on the resilience of other critical infrastructures, including water distribution systems (WDSs), whose healthy operation highly relies on the availability of power from PDSs. Here, this paper proposes an analytics model for quantifying the interdependence between the resilience of power and water distribution systems. The proposed model first performs spatio-temporal outage analysis on the PDS and WDS to determine the PDS power serving capability and the resulting cascading impact on the WDS water serving capability during the occurrence of disruptions. The resilience interdependence is then determined by a proposed set of six metrics calculated using the power and water serving capability profiles, which trace and quantify the cascading impacts of power outages in the operation of WDSs during the degradation and recovery stages. The proposed analytics model is implemented on the IEEE 33-bus power distribution system supplying power for pumping stations of a 15-node test WDS, considering multiple cases of water storage capacity, single and multiple outage scenarios, and availability of distributed generation. The numerical results demonstrate that the proposed metrics track the temporal and spatial interdependence between the resilience of power and water distribution systems, providing a mechanism to identify weak spots, and assess options to enhance the resilience of the critical water infrastructure.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Battery Storage for Resilience

As the capital costs of battery storage systems are decreasing, new opportunities to cost-effectively deploy the technology, often paired with renewable energy technologies, are emerging. At the same time, the duration and frequency of natural disasters is increasing. As a result, a growing number of institutions are deploying battery storage systems as a resilient energy solution because traditional back-up power solutions, like diesel generators, are not always sufficient, especially during longer-duration and larger-scale disasters. This fact sheet describes how battery storage, along with additional generation sources, can be used both to provide cost savings while grid-connected and to provide backup power when the grid goes down.

25 ENERGY STORAGE↗

Impacts Analysis of Amendments to Mexico's Unit Commitment and Dispatch Rules

In Mexico, there are various amendments, approved and under discussion to significantly modify the order in which generation units are committed and dispatched. This report quantifies the potential impacts on Mexico's power system, utilizing a production cost model of the Mexican power system that analyzes the hourly optimal electricity dispatch of the Mexican electricity system for 1 year under four scenarios, a reference scenario, and three alternative scenarios. These scenarios are meant to evaluate the potential impacts of increasing participation of the state-owned power plants in generation mix, electricity production costs, emissions, and renewable curtailment.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

GRAF-Plan for Vietnam

Evaluates the reserve requirements for power system balancing areas based on variability and uncertainty of load as well as wind and solar generation scenarios. The tool uses minute‐by‐minute site‐specific generation and load information, as well as information from generation and load forecasting algorithms used in the balancing areas. The Balancing‐Plan Tool can be used directly by utility planners and operators to aid in the integration of intermittent renewable resources. The tool provides reserve requirements of various kinds, such as day‐ahead, load following and regulation, as well as estimates the capacity of the generation fleet to provide the require reserves.

Campbell, Allison↗

Plan It Together: Optimizing Across Generation, Transmission, Distribution, and Distributed Energy Resources

Integrated planning holds the promise of unlocking lower total system cost solutions by connecting previously siloed planning processes. This article summarizes the state of bulk and local grid planning today and details multiple new analytical approaches that can enable more holistic planning methods to develop comprehensive solutions to generation, transmission, distribution, and distributed energy resource needs. These include both iterative approaches as well as cooptimization techniques. In addition to the benefits of these methods, the technical and institutional challenges and associated solutions are also discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data Analytics Methods to Measure Plant Outage Resilience

Every 18 or 24 months nuclear power plants (depending on plant configuration, pressurized or boiling water reactor respectively) undergo a period of outage where the plant is taken offline and a large number of maintenance and surveillance activities (that cannot be performed while plant is running) are performed in typically 2–3 weeks. Planning of a plant outage is very challenging since all the activities are required to be performed in the shortest amount of time given available resources (typically contractor crews hired for the duration of the outage). Consequently, plant outages can be costly due the actual loss of power generation and crew costs and, because of it, there is a need to maximize resource usage in the outage planning phase and reduce the risk of outage delays. This paper is addressing these needs by providing a set of analytical methods designed to analyze plant outage schedule and identify critical elements based on available resources (time and crews). These methods are based on natural language processing and optimization algorithms. In this respect, two classes of methods have been developed: one that focuses on the time resource and how variability in the time to complete outage tasks may impact outage delays, and one that minimizes the risk of outage delays by integrating available resources to assess when daily activities should be performed.

97 - MATHEMATICS AND COMPUTING↗

Ramping Up the Ramping Capability: India's Power System Transition

The Indian power system is going through a period of transformation with plans for renewable energy to be integrated at a large scale over the next decade. Increasing thrust is being given to flexible operation of existing generating resources. Ramping is one of the key attributes of flexibility. With implementation of national level security constrained economic dispatch (SCED), the national power system operator of India (POSOCO) has started to observe occasional constraints in ramping capability obtained from generators under SCED, which could get further aggravated with more variable renewable energy (VRE). This paper focuses on complexities of ramping and the challenges with high shares of renewables in the Indian context.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Electromagnetic Transient (EMT) Simulation Algorithm for Evaluation of Photovoltaic (PV) Generation Systems

Use of inverter-based resources facilitating renewable energy resources such as photovoltaic (PV) generation is increasing rapidly with decreasing costs and reduced emissions associated. To accommodate such rapid growth of inverter-based resources like PV systems, electromagnetic transient (EMT) simulation models of both PV systems and grids are required to analyze the interaction of PVs in the grid (like the post-event analysis). In addition, the EMT simulation would help with the planning of future power grid with a large number of PVs as well as other inverter-based distributed generation systems. In this paper, the EMT simulation models of PV systems and grids are developed based on the differential algebraic equations (DAEs) representing their EMT dynamics. Furthermore, advanced simulation algorithms including numerical stiffness-based hybrid discretization, DAE clustering and aggregation, multi-order integration, and matrix splitting approaches are applied to accelerate the EMT simulation. The proposed algorithm was applied to 125 PV inverters within 52-bus medium-voltage (MV) distribution grid.

Choi, Jongchan↗

Grid Integration of Renewable Energy and Energy Storage

Grid integration of renewable energy and energy storage requires forward-looking planning process, and increased emphasizes on reliability, resilience, and equity. Power-electronics based energy generation including solar, wind, distributed energy resources (DERs), and various types of grid-tied energy storage and emerging loads, are reshaping grid operator's understanding on interconnection level performance and responses. This paper will present the ongoing work at PNNL related to power electronics R&D, energy modeling and analysis, and a wide spectrum of grid stability studies and technologies in support of grid integration of renewable energy and energy storage.

Power Electronics, grid integration of renewable e↗

A Highly Efficient and Affordable Hybrid System for Hydrogen and Electricity Production (Final Project)

The pursuit of clean, secure, and sustainable energy has sparked significant interest in fuel cells for power generation and electrolyzer cells for hydrogen production. Among all types of fuel and electrolyzer cells, solid oxide cells (SOCs) have emerged as promising candidates due to their high efficiency and versatility. However, conventional oxygen-ion conductive SOCs face several challenges related to their performance and durability associated with their high-temperature operation (≥ 800 ºC). This has led to a growing interest in intermediate-temperature (≤ 650 ºC) proton-conducting solid oxide cells (p-SOCs) as potential alternatives. In collaboration between Phillips 66 and Georgia Tech, this project aims to achieve a 1 kW p-SOCs system to demonstrate the commercial viability of efficient SOC systems. This report addresses four primary areas and key challenges we overcame: (1) development of efficient and durable proton-conducting electrolyte (e.g., BaHf 0.1 Ce 0.7 Yb 0.2 O 3-δ ) and electrode/catalyst materials, (2) large area cell fabrication (10 x 10 cm 2 ), (3) scalable stack design and building (250 W and 1 kW), and (4) demonstration of a 1 kW prototype system. Notably, significant challenges faced during the large area cell fabrication process were addressed by achieving cell flatness, improving fabrication yield, and ensuring electrode/electrolyte interfacial adhesion. Stack designs were also developed, focusing on reducing contact resistance and optimizing stack components (e.g., sealants). These efforts resulted in the achievement of high performance and durability with promising outputs of 250 W and 1 kW. Furthermore, the integration of these stacks into a fuel-powered system was explored, with refinements made to heat management, as well as to pressure and heating conditions. The results demonstrated the potential applicability of our p-SOC technology in commercial energy storage and power generation systems. Additionally, the report discusses techno-economic analysis and a market transformation plan, aiming to evaluate and advance the commercial feasibility of this technology.

25 ENERGY STORAGE↗

Hybrid Electric Transit Bus

A government, industry, and university cooperative is developing an advanced hybrid electric city transit bus. Goals of this effort include doubling the fuel economy compared to current buses and reducing emissions to one-tenth of current EPA standards. Unique aspects of the vehicle's power system include the use of ultra-capacitors as an energy storage system, and a planned natural gas fueled turbogenerator developed from a small jet engine. Power from both the generator and energy storage system is provided to a variable speed electric motor attached to the rear axle. At over 15000 kg gross weight, this is the largest vehicle of its kind ever built using ultra-capacitor energy storage. This paper describes the overall power system architecture, the evolution of the control strategy, and its performance over industry standard drive cycles.

Viterna, Larry A.↗

Prospective Architectures for Onboard vs Cloud-Based Decision Making for Unmanned Aerial Systems

This paper investigates propsective architectures for decision-making in unmanned aerial systems. When these unmanned vehicles operate in urban environments, there are several sources of uncertainty that affect their behavior, and decision-making algorithms need to be robust to account for these different sources of uncertainty. It is important to account for several risk-factors that affect the flight of these unmanned systems, and facilitate decision-making by taking into consideration these various risk-factors. In addition, there are several technical challenges related to autonomous flight of unmanned aerial systems; these challenges include sensing, obstacle detection, path planning and navigation, trajectory generation and selection, etc. Many of these activities require significant computational power and in many situations, all of these activities need to be performed in real-time. In order to efficiently integrate these activities, it is important to develop a systematic architecture that can facilitate real-time decision-making. Four prospective architectures are discussed in this paper; on one end of the spectrum, the first architecture considers all activities/computations being performed onboard the vehicle whereas on the other end of the spectrum, the fourth and final architecture considers all activities/computations being performed in the cloud, using a new service known as Prognostics as a Service that is being developed at NASA Ames Research Center. The four different architectures are compared, their advantages and disadvantages are explained and conclusions are presented.

Software engineering↗

Fish Friendly Water Rules' Impact On the Power Grid with High VRE Levels

Columbia River basin multipurpose reservoirs are operated for hydropower production and many other purposes considering the aquatic habitat of the river basin. Specifically, the river basin fish population is a vital element for the tribal community of the river basin. When conventional thermal power plants are retired, hydropower flexibility balances the wind and solar variability of the power grid and provides grid services to maximize the high renewable power absorption. On the other hand, over-reliance on hydropower could harm the river basin fish habitat. For example, water release pulses during peak electricity demand hours and shorter-term water release variation could harm the fish population. Power grid planners, environmentalists, Columbia Basin tribes, hydro regulators, and water resource planners work together to understand the impacts of Columbia River basin operation in a fish-friendly way in the current power grid and power grid with higher renewable power share. We examine different levels of renewable share in the Western Interconnection to understand the multiple weather years and future climate projection and operating scenario impact on the power grid and water system. We measure power grid impacts for various water resources planning scenarios in terms of total system operating cost, system reliability indicators, changes in wind and solar generation and curtailments, local marginal prices, and revenue for hydropower producers. The study results inform reservoir operating rules decisions from hydropower power producers, system operators, other water users, tribes, environmentalists, and other stakeholders.

environmental↗