Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power balancing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

The Madison plasma dynamo experiment: A facility for studying laboratory plasma astrophysics

The Madison plasma dynamo experiment (MPDX) is a novel, versatile, basic plasma research device designed to investigate flow driven magnetohydrodynamic instabilities and other high-β phenomena with astrophysically relevant parameters. A 3 m diameter vacuum vessel is lined with 36 rings of alternately oriented 4000 G samarium cobalt magnets, which create an axisymmetric multicusp that contains ∼14 m3of nearly magnetic field free plasma that is well confined and highly ionized (>50%). At present, 8 lanthanum hexaboride (LaB6) cathodes and 10 molybdenum anodes are inserted into the vessel and biased up to 500 V, drawing 40 A each cathode, ionizing a low pressure Ar or He fill gas and heating it. Up to 100 kW of electron cyclotron heating power is planned for additional electron heating. The LaB6cathodes are positioned in the magnetized edge to drive toroidal rotation through J × B torques that propagate into the unmagnetized core plasma. Dynamo studies on MPDX require a high magnetic Reynolds number Rm > 1000, and an adjustable fluid Reynolds number 10 1). Initial results from MPDX are presented along with a 0-dimensional power and particle balance model to predict the viscosity and resistivity to achieve dynamo action.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Unlocking the price

To help balance load and power generation that ensue from the electrification of transportation and the increased connection of variable power sources to the grid, ABB has developed an RL-based dynamic price model for EV charging with the required flexibility to respond to changing grid conditions.

Suryanarayana, Harish↗

Dark Energy Survey Year 6 Results: improved mitigation of spatially varying observational systematics with masking

As photometric surveys reach unprecedented statistical precision, systematic uncertainties increasingly dominate large-scale structure probes relying on galaxy number density. Defining the final survey footprint is critical, as it excludes regions affected by artefacts or suboptimal observing conditions. For galaxy clustering, spatially varying observational systematics, such as seeing, are a leading source of bias. Template maps of contaminants are used to derive spatially dependent corrections, but extreme values may fall outside the applicability range of mitigation methods, compromising correction reliability. The complexity and accuracy of systematics modelling depend on footprint conservativeness, with aggressive masking enabling simpler, robust mitigation. We present a unified approach to define the DES Year 6 joint footprint, integrating observational systematics templates and artefact indicators that degrade mitigation performance. This removes extreme values from an initial seed footprint, leading to the final joint footprint. By evaluating the DES Year 6 lens sample MagLim++ plus plus on this footprint, we enhance the Iterative Systematics Decontamination (ISD) method, detecting non-linear systematic contamination and improving correction accuracy. While the mask's impact on clustering is less significant than systematics decontamination, it remains non-negligible, comparable to statistical uncertainties in certain w(theta) scales and redshift bins. Supporting coherent analyses of galaxy clustering and cosmic shear, the final footprint spans 4031.04 deg2, setting the basis for DES Year 6 1x2pt, 2x2pt, and 3x2pt analyses. This work highlights how targeted masking strategies optimise the balance between statistical power and systematic control in Stage-III and -IV surveys.

Rodríguez-Monroy, M. [Madrid, IFT; IJCLab, Orsay]↗

Stacked Low-Inertia Converter or Solid-State Transformer: Modeling and Model Predictive Priority-Shifting Control for Voltage Balance

This paper presents control challenges of stacked low-inertia converter (SLIC) or cascaded reduced dc-link solid-state transformer (SST) and proposes a novel model predictive priority-shifting (MPPS) control with implicit modulator and a discrete-time large-signal model for voltage balancing and dc-link regulation. Low-inertia converters, featuring small electrolytic capacitor-less dc links, dramatically reduce cost, size, and weight compared to conventional solutions. However, without a large dc-link buffer, the input and output are tightly coupled, leading to significant control challenges. The control becomes even more challenging with these converters stacked input-series output-parallel (ISOP) for medium-voltage (MV) grid, which causes coupling between the modules besides the coupling within each module. This paper analyzes the multi-objective, multi-degree of freedom control problem, using the modular soft-switching solid-state transformer (M-S4T) as an example of the SLIC. First, distribution of control efforts under controller saturation is critical because multiple control objectives can be conflicting, especially when the module voltages are unbalanced and are being restored. The MPPS can shift the priorities to address this issue. Second, due to the low inertia and high dc-link ripple, classic space vector pulse-width modulation (SVPWM), average model with small-ripple assumption, and control design based on small-signal model cannot accurately modulate, model, and control the nonlinear reduced dc link. Therefore, a discrete-time large-signal model of the M-S4T is established to derive the predictive control in the MPPS. The MPPS and the PI control are compared in MV simulations to show the issue of applying the PI to the SLIC and the effectiveness of the MPPS for voltage balancing and dc-link regulation in a deadbeat manner. Finally, the proposed control is tested on a 5 kV ISOP SiC SST prototype to verify priority shifting to address controller saturation issue and fast and robust voltage balancing.

14 SOLAR ENERGY↗

L-H transition trigger physics in ITER-similar plasmas with applied n = 3 magnetic perturbations

The L–H transition power threshold PLH is observed to increase with applied n = 3 resonant magnetic perturbations (RMP) in ITER-similar-shape plasmas with balanced neutral beam torque injection in DIII-D. The increase is most pronounced with added electron–cyclotron heating: PLH increases with decreasing edge plasma collisionality as PLH/PLH-08 ~ (ν*)−0.5, where PLH-08 is the 2008 ITPA multi-machine power threshold scaling. This result raises concerns for H-mode access at low edge collisionality in ITER, where RMP may have to be applied before the L–H transition to safely suppress the first edge-localized mode. Non-axisymmetric modifications with RMP include a simultaneous reduction of the radial electric field (Er) well depth and E × B shear. This can be attributed to increasing edge toroidal co-current rotation, and is consistent with substantially increased local long-wavelength turbulence (measured via beam emission spectroscopy). At high RMP perturbation strength the edge electric field Er reverses sign locally (becomes positive), with changes in dominant turbulence modes. Edge magnetic stochasticity provides an attractive explanation of the observed modifications, and the observed changes in toroidal rotation and Er are consistent with a simple fluid model describing radial electron current flow along stochastic fieldlines. The observed collisionality dependence of the L-mode edge electric field with applied RMP is also qualitatively consistent with this model. Reflectometry data indicate a significant reduction of the normalized L-mode radial density gradient a/Ln at high RMP field with simultaneous increase in radial particle flux and electron thermal flux from power balance analysis. We conjecture that the increase of PLH with RMP results from the combined effects of reduced E × B flow shear (increasing turbulent transport levels) and toroidal/poloidal flow modulation due to edge stochasticity. Initial experiments indicate that non-resonant n = 3 magnetic perturbations lead only to relatively small changes in Er, E × B shear and fluctuation characteristics, and have less impact on the L–H transition power threshold. This motivates further exploration of the RMP spectrum dependence of PLH for possible mitigation of the observed threshold increase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Computationally inexpensive part-scale thermal history of additive friction-stir deposition

This study presents an analytical model for steady-state power generation and tool heat loss in additive friction-stir deposition (AFSD), developed to enable part-scale thermal simulation while remaining computationally inexpensive. The model predicts total generated power, yielding 3.7–4.7 kW across deposition temperature setpoints of 400–460 °C for the deposition of AA6061 with a Be-Cu tool. This corresponds to 90–95% of the reported spindle power. Tool heat loss is experimentally determined by calibrating a steady-state energy balance between the generated power, the substrate-deposition thermal gradient, and a temperature dependent tool heat loss term: q tool (T) = a + b (T - 400°C) with a = 2.7 x 10 6 Wm -2 and b = 9.5 x 10 3 Wm -2 K -1 . The calibration indicates that about 69% of the generated heat is conducted into the tool for this configuration, which is much higher than previously reported. The calibrated heat-source is implemented in finite element software (Adamantine) to simulate the transient thermal history of a 100 cm 3 representative build in 8 min on a standard desktop (at 0.635 mm build-height resolution). For the first three layers, the substrate temperatures between simulation and experiment are within 10% mean absolute percentage error. Sensitivity analysis indicates that uncertainties in average deposition temperature and deformation localization (stir-zone geometry, depth, and spatial dependance of strain-rate and flow stress) dominate model variance, motivating additional experimental verification.

Additive Friction-Stir Deposition↗

Leak detection in a subcritical boiler

Thermal power plants experience cycling duty leading to the fatigue of the boiler and heat exchanger tubes. As a result, tube failures occur frequently in coal fired fleets leading to forced outages. Furthermore, because the tube leaks have been the major source of unwanted shutdowns and the number of outages is increasing, present work focuses on the detection and isolation of the leak in a subcritical boiler based upon the process data from a commercial coalfired power plant. The mass balance equation around the steam drum was analyzed using timeseries data collected from a 300 MW power plant. The ratio of the feed water mass flow rate to the steam mass flow rate was defined as a key parameter for detecting leaks. The difference in slope between the feedwater and steam mass flow rate during the normal and faulty operations was established as the upper control limit for real time monitoring. To reduce false alarm rates that arise when raw signal is directly compared against the threshold due to common process fluctuations, an optimal filter was derived for smoothing. It was found that the optimal filter reacted much more quickly to process changes than an exponential moving average filter, around 8 h earlier on average. Occurrence of relatively high false alarm rates even in the filtered responses was related to the cycling of the boiler from the base load condition. Variable threshold was established to keep false alarm rates to the minimum while maintaining the leak detection rate. Finally, the leak was located at the economizer and this could readily be isolated by investigating the magnitude of the mass flow rates ratio and the temperature at the economizer outlet.

42 ENGINEERING↗

Analysis of the HAE activity in the TJ-II stellarator using a Landau closure model

The aim of this study is to analyze the stability of helical Alfvén eigenmodes (HAEs) in TJ-II discharges and the stabilizing effect of the energetic particles generated by the neutral beam injector (NBI) on pressure gradient-driven modes (PGDMs). HAE and PGDM stability is studied using the linear version of the gyro-fluid code FAR3d and the continuous structure by the STELLGAP code. First, Alfvén eigenmode (AE) and PGDM activity observed in the experiments is reproduced by the simulations, identifying unstable m/n = 4/7 − 2/3 and 7/12 − 5/8 HAEs triggered around ρ = 0.66 showing a frequency of 209 and 204 kHz, respectively, as well as 5/3 PGDM. Next, a parametric study is performed with respect to the thermal ion density and iota profile in the middle-outer plasma region to verify the robustness of the simulation results with respect to the uncertainty of experimental profiles. The analysis confirms that experimental uncertainty does not cause large deviations in the simulation results, showing the destabilization of the same HAEs for all the configurations tested. The simulations also indicate the decay of the 5/3 PGDM growth rate as the energetic particle (EP) population in the plasma increases, consistent with the experiment. Stability analysis of the n = 3, 7, 11, n = 5, 9, 13, n = 6, 10, 14, and n = 8, 12 helical families is performed with respect to the NBI operational regime for different EP energies, β as well as deposition profiles. The most unstable configuration is the radially localized on-axis NBI operation (stiff EP density profile gradients nearby the magnetic axis). Using the simulation model that reproduces the observed Alfvén activity, we extend the study to analyze NBI performance within a theoretical framework. It shows that increasing NBI voltage (which raises EP energy) leads to a degradation in NBI performance for a given power (related to EP β and their density). To achieve better NBI operation, higher voltage must be balanced with lower injection power, ensuring stable AEs while keeping the same EP β.

Plasma confinement↗

Balancing Authority Data Reformatted

We collect the data from the electricity balancing authorities (BAs) that operate the grid. A balancing authority ensures, in real time, that power system demand and supply are finely balanced. This balance is needed to maintain the safe and reliable operation of the power system.

17 WIND ENERGY↗

Software Control Program For Transportable Microgrid State-of-charge Balancing And Frequency Stability Controls

A deterministic state-of-charge (SOC) balancing approach software control code is introduced as an integral secondary management to primary control layer of an islanded small microgrid or nanogrid system made up of multiple grid-forming inverter/battery/solar combination systems, where each set of batteries with each inverter are on independent DC buses (i.e. non-paralleled on the DC sides). A DERMS-level control approach, algorithm and automation controller program was developed to improve coordination and enable microgrid asset compliance and SOC balancing, enabling provision of a system-level power stability support architecture, load support, and asset scalability. The architecture is configured to treat each unit or micro/nano-grid as a node in a microgrid network, allowing for autonomous DERMS control regarding load and SOC balancing and power stability. As the network grows with the addition of units, greater coordination efforts may be required. The ideal small network microgrid ranges from 2-10 inverter/battery units before additional control parameters must be considered in the existing architecture. The control approach focuses on a deterministic state-of-charge analysis as the primary level control process followed by a secondary control loop using a forced frequency-watt droop strategy to conform off-the-shelf components into behaving under a leader-follower configuration. Adopting this control scheme has been shown to allow for a balanced, unit-coordinated microgrid network, enabling stable power flow. The deterministic state-of-charge approach is introduced as an integral primary control layer of an islanded small network microgrid. A standard strategy for SOC balancing is implementing a battery management system (BMS) to control SOC on the DC side. An alternative approach is to determine how to coordinate sending and receiving power on the AC side with multiple units. The latter approach assesses all the integrated units in the microgrid network. Once the individual units are identified, further system data is required to calculate each unit's total kWh, provided information about its capability to supply or consume kWh and availability. The secondary control layer in the multi-layered small network microgrid methodology uses the primary layer’s decision to initiate frequency setpoint changes, initializing the SOC balancing. The secondary control layer considers numerous system-dependent variables to enable a charging and discharging profile based on adjustable frequency setpoints. The combined architecture will result in stable, coordinated power flow enhancing an AC microgrid's functionalities.

Myers, KurtS [Idaho National Laboratory (INL), Ida↗

Absorbing the Sun: Operational Practices and Balancing Reserves in Florida's Municipal Utilities

The Florida Reliability Coordinating Council (FRCC) power system is comprised of multiple balancing authorities ranging in size from Gainesville Regional Utilities (GRU) with a 2019 summer net firm demand of 429 MW to Florida Power & Light with a 2019 summer net firm demand of 22,510 MW; and including cooperative, municipal, and investor-owned utilities. As all of these balancing authorities are and have plants to continue installing significant quantities of utility-scale solar photovoltaics, one relevant question is how much operating reserves they will need to hold as solar penetrations increase. While there are estimates of how regulating and flexibility reserve requirements change with solar penetration, the literature almost exclusively focuses on large balancing authorities with sub-hourly dispatch. In this work we analyze how reserve needs change not only with solar photovoltaic penetration, but also balancing authority size and operational practices. We find that, measured as a fraction of load, smaller balancing authorities with less frequent load and solar forecasts and less frequent dispatch need more reserves. Such utilities' reserve needs also increase more with increasing solar deployment as compared to larger or more frequently dispatched balancing authorities. These impacts are most acute for GRU. We find that moving from day-ahead to hour-ahead load and solar forecasting and system dispatch could enable GRU to incorporate 32% solar generation with median reserves at 20% instead of 60% of load; and that median reserve needs could drop further to about 10% of load if Florida's municipal utilities formed a reserve sharing group and moved to sub-hourly dispatch.

balancing authority↗

A comparison of the power potential for surface- and seabed-deployed tidal turbines in the San Juan Archipelago, Salish Sea, WA

The San Juan archipelago lies along the axis of tidal movement between Straits of Juan de Fuca and Strait of Georgia in the Salish Sea. The amplitude of the tidal exchange produces significant tidal currents between the islands, as well as in Rosario and Haro Straits. These are of interest as a future source of electrical power generation, given the islands’ dependence on electricity supply by a subsea cable from the mainland. Here, we evaluate the tidal current energy potential in this region through a re-analysis of measurements collected by the National Ocean Service (NOS) and a high-resolution numerical model. Given the considerable variations in water depth and vertical velocity profiles across candidate tidal energy sites, we consider the trade-offs between tidal turbines deployed from a floating platform and those anchored to the seabed. Measurement re-analysis indicates several locations that could support tidal current power generation by MW-scale turbines with an acceptable balance between turbine size, rated power, and capacity factor. Even for relatively large (30 m) turbine diameters, surface-deployed turbines would be expected to produce up to 30 % more electricity than the same turbine deployed near the seabed due to vertical shear, with this difference increasing for smaller diameter turbines. A benchmark comparison at the measurement locations with the highest power generation potential shows relatively good model fidelity, though, even with relatively high resolution, time-average power density disagreements of ± 50 % persist throughout the water column. Nonetheless, the simulation identifies several locations with power generation potential more than twice as high as locations in the measurement re-analysis. These sites were either not surveyed by NOS or excluded due to data quality issues. Altogether, these results demonstrate the complimentary of models and measurements for tidal energy site assessment and suggest that tidal currents could be an important source of electricity generation in the San Juan archipelago.

16 TIDAL AND WAVE POWER↗

Absorbing the Sun: Operational Practices and Balancing Reserves in Florida's Municipal Utilities

The Florida Reliability Coordinating Council (FRCC) power system is comprised of multiple balancing authorities ranging in size from Gainesville Regional Utilities (GRU) with a 2019 summer net firm demand of 429 MW to Florida Power & Light with a 2019 summer net firm demand of 22,510 MW; and including cooperative, municipal, and investor-owned utilities. As all of these balancing authorities are and have plants to continue installing significant quantities of utility-scale solar photovoltaics, one relevant question is how much operating reserves they will need to hold as solar penetrations increase. While there are estimates of how regulating and flexibility reserve requirements change with solar penetration, the literature almost exclusively focuses on large balancing authorities with sub-hourly dispatch. In this work we analyze how reserve needs change not only with solar photovoltaic penetration, but also balancing authority size and operational practices. We find that, measured as a fraction of load, smaller balancing authorities with less frequent load and solar forecasts and less frequent dispatch need more reserves. Such utilities' reserve needs also increase more with increasing solar deployment as compared to larger or more frequently dispatched balancing authorities. These impacts are most acute for GRU. We find that moving from day-ahead to hour-ahead load and solar forecasting and system dispatch could enable GRU to incorporate 32% solar generation with median reserves at 20% instead of 60% of load; and that median reserve needs could drop further to about 10% of load if Florida's municipal utilities formed a reserve sharing group and moved to sub-hourly dispatch.

14 SOLAR ENERGY↗

Fish Friendly Water Rules' Impact On the Power Grid with High VRE Levels

Columbia River basin multipurpose reservoirs are operated for hydropower production and many other purposes considering the aquatic habitat of the river basin. Specifically, the river basin fish population is a vital element for the tribal community of the river basin. When conventional thermal power plants are retired, hydropower flexibility balances the wind and solar variability of the power grid and provides grid services to maximize the high renewable power absorption. On the other hand, over-reliance on hydropower could harm the river basin fish habitat. For example, water release pulses during peak electricity demand hours and shorter-term water release variation could harm the fish population. Power grid planners, environmentalists, Columbia Basin tribes, hydro regulators, and water resource planners work together to understand the impacts of Columbia River basin operation in a fish-friendly way in the current power grid and power grid with higher renewable power share. We examine different levels of renewable share in the Western Interconnection to understand the multiple weather years and future climate projection and operating scenario impact on the power grid and water system. We measure power grid impacts for various water resources planning scenarios in terms of total system operating cost, system reliability indicators, changes in wind and solar generation and curtailments, local marginal prices, and revenue for hydropower producers. The study results inform reservoir operating rules decisions from hydropower power producers, system operators, other water users, tribes, environmentalists, and other stakeholders.

environmental↗

Managing Solar Photovoltaic Integration in the Western United States Appendix: Reference and High Solar Photovoltaic Scenarios for Three Regions [Slides]

This slide deck is an appendix to a paper series that examines potential challenges related to planning future power systems with higher solar photovoltaic (PV) penetrations. The series uses the western U.S. power system for these investigations because it is a region the authors and their colleagues have already extensively studied. We are therefore well-suited to analyze even higher PV penetrations and then examine the results in multiple models to determine whether our current approaches are missing key details that only emerge at higher PV penetrations. This deck details the systems underlying those analyses and how they were modeled using the Resource Planning Model (RPM), a capacity expansion modeling tool. We examine both Western Interconnection-wide and regional results for three regions in the Western U.S. with significantly different existing power systems and connections to neighboring regions; this provides a more balanced picture as to how power systems with high PV penetration might emerge in different contexts and what the resulting grid challenges, if any, might be.

14 SOLAR ENERGY↗

Co-optimization of nuclear reactor flexible power operation and maintenance scheduling

As flexible power operation of nuclear power plants becomes more attractive due to the reduction in fossil-fueled dispatchable generation on energy grids, finding optimal power production strategies that balance revenue generation with operational concerns becomes more complex. This article presents a general framework to aid operators in designing economically optimal long term dispatch strategies for nuclear power plants. The principal novelty is the linking of estimated system remaining useable life (RUL) to strategic operational decisions. It is shown that, depending on the relationship between the fixed costs from maintenance and the associated lost revenue from an outage, it can be economically optimal in the long term to delay a maintenance outage and not perform this alongside refueling. For a given relationship between power ramping and degradation, optimal strategies were found that discouraged load following in some situations while minimizing unnecessary maintenance. It is shown that heavy load following can cause maintenance and refueling outages to diverge due to their inverse relationships with respect to load following, potentially leading to a significant loss in capacity factor. As a result, this general framework can be applied to specific reactor dispatch allowing operators to adapt operational strategies as future grid conditions change.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Validation and Demonstration of Control System Functional Capabilities within the IES Plug-and-Play Simulation Environment

The concept of an integrated energy system (IES) is meant to combine different energy technologies in synergistic ways to achieve a more secure and economical energy supply. The RAVEN-based HYBRID framework is used to find the optimal installed capacity and the optimal economical dispatch of each component of the IES. The new RAVEN plugin for grid and capacity optimization (HERON) only addresses the limits that affect the production variables and the corresponding rates of variation (explicit constraints). However, other variables are subject to constraints, and the associated limits should be accounted for (implicit constraints). In particular, for the power dispatch problem, the optimization algorithm takes into account the limits on the electrical power output and the corresponding hourly power variations but does not consider other constraints on process variables whose response affects the service life of the IES. This report describes a scheme that allows accounting for implicit constraints without increasing the size of the optimization problem. To obtain a more accurate approximation of the nonlinear dynamic behavior, a parametric version of the dynamic mode decomposition with control (DMDc) algorithm was developed to derive the state-space representation matrices of the IES components at different scheduling parameter. Thanks to this approach, a more accurate approximation of the system response can be obtained, the limits imposed by thermal mechanical implicit constraints can be translated into power dispatch limits, and the feedbacks to HERON power dispatcher can be provided. To assess the developed methodology, a power dispatching test case composed of three power generating and storage units (Balance of Plant, Secondary Energy Source, Thermal Energy Storage) was developed. The power output of each one of the three units was optimized to meet the imposed time-dependent load demand trajectory and to maximize the IES profitability by meeting both the explicit and implicit constraints.

24 POWER TRANSMISSION AND DISTRIBUTION↗